IEC 60730-2-5:2026 applies to automatic electrical burner control systems for the automatic control of burners for oil, gas, coal or other combustibles intended to be used
- for household and similar use;
- in shops, offices, hospitals, farms and commercial and industrial applications;
NOTE 1 Throughout this document, where it can be used unambiguously, the word "system" means "burner control system" and "systems" means "burner control systems".
- for equipment that is used by the public, such as equipment intended to be used in shops, offices, hospitals, farms and commercial and industrial applications;
NOTE 2 Throughout this document, the word "equipment" means "appliance and equipment."
EXAMPLE 1 Controls for commercial catering, heating and air-conditioning equipment.
- that are smart enabled controls;
EXAMPLE 2 Remote interfaces/control of burner operations.
- that are AC or DC powered controls with a rated voltage not exceeding 690 V AC or 600 V DC;
- used in, on, or in association with equipment that use electricity, gas, oil, solid fuel, solar thermal energy, etc., or a combination thereof;
- utilized as part of a control system or controls which are mechanically integral with multifunctional controls having non-electrical outputs;
- using NTC or PTC thermistors and to discrete thermistors, requirements for which are contained in Annex J;
- that are mechanically or electrically operated, responsive to or controlling such characteristics as temperature, pressure, passage of time, humidity, light, electrostatic effects, flow, or liquid level, current, voltage, acceleration, or combinations thereof;
- as well as manual controls when such are electrically and/or mechanically integral with automatic controls.
NOTE 3 Requirements for manually actuated mechanical switches not forming part of an automatic control are contained in IEC 61058-1-1.
This document is applicable
- to a complete burner control system;
- to a separate programming unit;
- to a separate electronic high-voltage ignition source;
- to a separate flame detector, and
- to a separate high-temperature operation (HTO) detector.
- to a burner control system intended to be used in warm air heating appliances (furnaces) where the appliance is equipped with an electromechanical differential pressure control to monitor the difference of the combustion air pressure (Type 2.AL). This pressure control provides a switch as an alternative to one of the two switching elements to directly de-energize the safety relevant terminals.
This document does not apply to thermoelectric flame supervision controls; thermoelectric flame supervision controls are covered by ISO 23551-6:2021.
This document also applies to electrical burner control systems intended exclusively for industrial process applications e.g. those applications covered by ISO TC 244 (ISO 13577 series).
This document applies to controls powered by primary or secondary batteries, requirements for which are contained within the standard.
This document applies to
- the inherent safety of automatic electrical burner control systems, and
- functional safety of automatic electrical burner control systems,
- automatic electrical burner control systems where the performance (for example the effect of EMC phenomena) of the product can impair the overall safety and perfo

  • Standard
    59 pages
    English language
    e-Library read for
    1 day

IEC 60730-2-15:2026 applies to automatic electrical air flow, water flow and water level sensing controls
- for use in, on, or in association with boilers with a maximum pressure rating of 2 000 kPA (20 bar) and equipment for general household and similar use including controls for heating, air-conditioning and similar applications;
NOTE 1 Throughout this document, the word "equipment" means "appliance and equipment" and "controls" means "automatic electrical air flow, water flow and water level sensing controls".
EXAMPLE 1 Water flow and water level sensing controls of the float or electrode-sensor type used in boiler applications and air flow, water flow and water level sensing controls for swimming pool pumps, water tank pumps, cooling towers, dishwashers, washing machines, air conditioning chillers and ventilation applications.
- for building automation within the scope of ISO 16484 series and IEC 63044 series (HBES/BACS);
EXAMPLE 2 Independently mounted air flow, water flow and water level sensing controls in smart grid systems and controls for building automation systems within the scope of ISO 16484-2.
- for equipment that is used by the public, such as equipment intended to be used in shops, offices, hospitals, farms and commercial and industrial applications;
EXAMPLE 3 Controls for commercial boilers, heating and air-conditioning equipment.
- that are smart enabled controls;
EXAMPLE 4 Smart grid control, remote interfaces/control of energy-consuming equipment including computer or smart phone.
- that are AC or DC powered controls with a rated voltage not exceeding 690 V AC or 600 V DC;
- used in, on, or in association with equipment that use electricity, gas, oil, solid fuel, solar thermal energy, etc., or a combination thereof;
- utilized as part of a control system or controls which are mechanically integral with multifunctional controls having non-electrical outputs;
- using NTC or PTC thermistors and to discrete thermistors, requirements for which are contained in Annex J;
- that are mechanically or electrically operated, responsive to or controlling air flow, water flow and water level;
- as well as manual controls when such are electrically and/or mechanically integral with automatic controls.
NOTE 2 Requirements for manually actuated mechanical switches not forming part of an automatic control are contained in IEC 61058-1-1.
This document applies to
- the inherent safety of automatic electrical air flow, water flow and water level sensing controls, and
- functional safety of automatic air flow, water flow and water level sensing electrical controls and safety related systems,
- controls where the performance (for example the effect of EMC phenomena) of the product can impair the overall safety and performance of the controlled system,
- the operating values, operating times, and operating sequences where such are associated with equipment safety.
This document specifies the requirements for construction, operation and testing of automatic electrical air flow, water flow and water level sensing controls used in, on, or in association with an equipment.
This document takes into account the response value of an automatic action of a control where such a response value is dependent upon the method of mounting the control. Where a response value is of significant purpose for the protection of the user, or surroundings, the value defined in the appropriate h

  • Standard
    46 pages
    English language
    e-Library read for
    1 day

This clause of Part 1 is replaced by the following:
This document applies to temperature sensing controls
– for use in, on, or in association with equipment for household appliance and similar use, including equipment for heating, air-conditioning and similar applications. The equipment can use electricity, gas, oil, solid fuel, solar thermal energy, etc., or a combination thereof.
NOTE 1 Throughout this document, the word "equipment" means "appliance and equipment" and "controls" means "temperature sensing controls".
– for building automation within the scope of ISO 16484 series and IEC 63044 series (HBES/BACS);
EXAMPLE 1 Independently mounted temperature sensing controls, controls in smart grid systems and controls for building automation systems within the scope of ISO 16484-2.
– for equipment that is used by the public, such as equipment intended to be used in shops, offices, hospitals, farms and commercial and industrial applications;
EXAMPLE 2 Controls for commercial catering, heating and air-conditioning equipment.
– that are smart enabled controls;
EXAMPLE 3 Smart grid control, remote interfaces/control of energy-consuming equipment including computer or smart phone.
– that are AC or DC powered controls with a rated voltage not exceeding 690 V AC or 600 V DC;
– used in, on, or in association with equipment that use electricity, gas, oil, solid fuel, solar thermal energy, etc., or a combination thereof;
– utilized as part of a control system or controls which are mechanically integral with multifunctional controls having non-electrical outputs;
– using NTC or PTC thermistors and to discrete thermistors, requirements for which are contained in Annex J;
– that have electrical circuits and control circuits which are, for example, operated by bimetals, magnet coils, memory metals, pressure elements, temperature-sensitive
expansion elements or electronic elements.
– as well as manual controls when such are electrically and/or mechanically integral with automatic controls.
NOTE 2 Requirements for manually actuated mechanical switches not forming part of an automatic control are contained in IEC 61058-1-1.
This document applies to
– the inherent safety of automatic electrical controls, and
– functional safety of temperature sensing controls and safety related systems,
– controls where the performance (for example the effect of EMC phenomena) of the product can impair the overall safety and performance of the controlled system,
– the operating values, operating times, and operating sequences where such are associated with equipment safety and to the testing of automatic electrical temperature sensing control devices used in, or in association with, equipment,
EXAMPLE 4 Boiler thermostats, fan controls, temperature limiters and thermal cut-outs.
– electrical safety of temperature sensing controls with non-electrical outputs such as refrigerant flow and gas controls,
– single-operation devices as defined in this document.
This document specifies the requirements for construction, operation and testing of automatic electrical controls used in, on, or in association with an equipment.
This document does not
– apply to automatic electrical temperature sensing controls intended exclusively for industrial process applications unless explicitly mentioned in the relevant part 2 or the equipment standard. However, this document can be applied to evaluate automatic electrical controls intended specifically for industrial applications in cases where no relevant safety standard exists.
– take into account the response value of an automatic action of a control, if such a response value is dependent upon the method of mounting the control in the equipment. Where a response value is of significant purpose for the protection of the user, or surroundings, the value defined in the appropriate equipment standard or as determined by the manufacturer will apply.
– address the integrity of the output signal to the networ

  • Standard
    79 pages
    English language
    e-Library read for
    1 day

This clause of Part 1 is replaced by the following:
This document applies to temperature sensing controls
– for use in, on, or in association with equipment for household appliance and similar use, including equipment for heating, air-conditioning and similar applications. The equipment can use electricity, gas, oil, solid fuel, solar thermal energy, etc., or a combination thereof.
NOTE 1 Throughout this document, the word "equipment" means "appliance and equipment" and "controls" means "temperature sensing controls".
– for building automation within the scope of ISO 16484 series and IEC 63044 series (HBES/BACS);
EXAMPLE 1 Independently mounted temperature sensing controls, controls in smart grid systems and controls for building automation systems within the scope of ISO 16484-2.
– for equipment that is used by the public, such as equipment intended to be used in shops, offices, hospitals, farms and commercial and industrial applications;
EXAMPLE 2 Controls for commercial catering, heating and air-conditioning equipment.
– that are smart enabled controls;
EXAMPLE 3 Smart grid control, remote interfaces/control of energy-consuming equipment including computer or smart phone.
– that are AC or DC powered controls with a rated voltage not exceeding 690 V AC or 600 V DC;
– used in, on, or in association with equipment that use electricity, gas, oil, solid fuel, solar thermal energy, etc., or a combination thereof;
– utilized as part of a control system or controls which are mechanically integral with multifunctional controls having non-electrical outputs;
– using NTC or PTC thermistors and to discrete thermistors, requirements for which are contained in Annex J;
– that have electrical circuits and control circuits which are, for example, operated by bimetals, magnet coils, memory metals, pressure elements, temperature-sensitive
expansion elements or electronic elements.
– as well as manual controls when such are electrically and/or mechanically integral with automatic controls.
NOTE 2 Requirements for manually actuated mechanical switches not forming part of an automatic control are contained in IEC 61058-1-1.
This document applies to
– the inherent safety of automatic electrical controls, and
– functional safety of temperature sensing controls and safety related systems,
– controls where the performance (for example the effect of EMC phenomena) of the product can impair the overall safety and performance of the controlled system,
– the operating values, operating times, and operating sequences where such are associated with equipment safety and to the testing of automatic electrical temperature sensing control devices used in, or in association with, equipment,
EXAMPLE 4 Boiler thermostats, fan controls, temperature limiters and thermal cut-outs.
– electrical safety of temperature sensing controls with non-electrical outputs such as refrigerant flow and gas controls,
– single-operation devices as defined in this document.
This document specifies the requirements for construction, operation and testing of automatic electrical controls used in, on, or in association with an equipment.
This document does not
– apply to automatic electrical temperature sensing controls intended exclusively for industrial process applications unless explicitly mentioned in the relevant part 2 or the equipment standard. However, this document can be applied to evaluate automatic electrical controls intended specifically for industrial applications in cases where no relevant safety standard exists.
– take into account the response value of an automatic action of a control, if such a response value is dependent upon the method of mounting the control in the equipment. Where a response value is of significant purpose for the protection of the user, or surroundings, the value defined in the appropriate equipment standard or as determined by the manufacturer will apply.
– address the integrity of the output signal to the networ

  • Standard
    79 pages
    English language
    e-Library read for
    1 day

IEC 60730-2-15:2026 applies to automatic electrical air flow, water flow and water level sensing controls - for use in, on, or in association with boilers with a maximum pressure rating of 2 000 kPA (20 bar) and equipment for general household and similar use including controls for heating, air-conditioning and similar applications; NOTE 1 Throughout this document, the word "equipment" means "appliance and equipment" and "controls" means "automatic electrical air flow, water flow and water level sensing controls". EXAMPLE 1 Water flow and water level sensing controls of the float or electrode-sensor type used in boiler applications and air flow, water flow and water level sensing controls for swimming pool pumps, water tank pumps, cooling towers, dishwashers, washing machines, air conditioning chillers and ventilation applications. - for building automation within the scope of ISO 16484 series and IEC 63044 series (HBES/BACS); EXAMPLE 2 Independently mounted air flow, water flow and water level sensing controls in smart grid systems and controls for building automation systems within the scope of ISO 16484-2. - for equipment that is used by the public, such as equipment intended to be used in shops, offices, hospitals, farms and commercial and industrial applications; EXAMPLE 3 Controls for commercial boilers, heating and air-conditioning equipment. - that are smart enabled controls; EXAMPLE 4 Smart grid control, remote interfaces/control of energy-consuming equipment including computer or smart phone. - that are AC or DC powered controls with a rated voltage not exceeding 690 V AC or 600 V DC; - used in, on, or in association with equipment that use electricity, gas, oil, solid fuel, solar thermal energy, etc., or a combination thereof; - utilized as part of a control system or controls which are mechanically integral with multifunctional controls having non-electrical outputs; - using NTC or PTC thermistors and to discrete thermistors, requirements for which are contained in Annex J; - that are mechanically or electrically operated, responsive to or controlling air flow, water flow and water level; - as well as manual controls when such are electrically and/or mechanically integral with automatic controls. NOTE 2 Requirements for manually actuated mechanical switches not forming part of an automatic control are contained in IEC 61058-1-1. This document applies to - the inherent safety of automatic electrical air flow, water flow and water level sensing controls, and - functional safety of automatic air flow, water flow and water level sensing electrical controls and safety related systems, - controls where the performance (for example the effect of EMC phenomena) of the product can impair the overall safety and performance of the controlled system, - the operating values, operating times, and operating sequences where such are associated with equipment safety. This document specifies the requirements for construction, operation and testing of automatic electrical air flow, water flow and water level sensing controls used in, on, or in association with an equipment. This document takes into account the response value of an automatic action of a control where such a response value is dependent upon the method of mounting the control. Where a response value is of significant purpose for the protection of the user, or surroundings, the value defined in the appropriate h

  • Standard
    46 pages
    English language
    e-Library read for
    1 day

IEC 60947-6-1:2026 applies to transfer switching equipment (TSE), to be used in power systems for ensuring the continuity of the supply and allowing the energy management of the installation, by transferring a load between power supply sources, the rated voltage of which does not exceed 1 000 V AC or 1 500 V DC. Specific requirements for bypass/isolation transfer switch equipment are given in Annex C, ATSE having closed transition capability are given in Annex D, stand-alone ATS controllers are given in Annex E, and TSE for electric driven fire pump controllers are given in Annex F.
It covers:
- manually operated transfer switching equipment (MTSE);
- remotely operated transfer switching equipment (RTSE);
- automatic transfer switching equipment (ATSE), including the controller;
- stand-alone ATS controllers;
- bypass/isolation transfer switch equipment (BTSE);
- ATSE having closed transition capability;
- fire pump TSE.
It does not cover:
- TSE configurations that are not fully manufacturer type tested or marked according to this document as a complete transfer switch;
- auxiliary contacts (for guidance, see IEC 60947-5-1);
- transfer switches used in explosive atmospheres (for guidance, see IEC 60079 (all parts));
- embedded software design (for guidance, see IEC TR 63201);
- cybersecurity aspects (for guidance, see IEC 63208);
- TSE rated for direct-on-line starting asynchronous motor of design NE and HE, according to IEC 60034-12. (for guidance, see AC-3e utilisation category according to IEC 60947 4 1);
- other types of TSE under consideration including overlapping neutral TSE, multi-source TSE (i.e. TSE with more than two sources of supply), TSE with load-shedding functions, bus-tie TSE, and hybrid TSE;
- static transfer switches covered by IEC 62310 series.
This fourth edition cancels and replaces the third edition published in 2021. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
- clarification of scope;
- clarification of terms and definitions;
- Annex C for Bypass/Isolation Transfer Switch Equipment;
- Annex D for ATSE having closed transition capability;
- Annex E for Stand-alone ATS controller;
- Annex F for TSE used with electric driven fire pump control equipment.

  • Standard
    102 pages
    English language
    e-Library read for
    1 day

IEC 60730-2-5:2026 applies to automatic electrical burner control systems for the automatic control of burners for oil, gas, coal or other combustibles intended to be used - for household and similar use; - in shops, offices, hospitals, farms and commercial and industrial applications; NOTE 1 Throughout this document, where it can be used unambiguously, the word "system" means "burner control system" and "systems" means "burner control systems". - for equipment that is used by the public, such as equipment intended to be used in shops, offices, hospitals, farms and commercial and industrial applications; NOTE 2 Throughout this document, the word "equipment" means "appliance and equipment." EXAMPLE 1 Controls for commercial catering, heating and air-conditioning equipment. - that are smart enabled controls; EXAMPLE 2 Remote interfaces/control of burner operations. - that are AC or DC powered controls with a rated voltage not exceeding 690 V AC or 600 V DC; - used in, on, or in association with equipment that use electricity, gas, oil, solid fuel, solar thermal energy, etc., or a combination thereof; - utilized as part of a control system or controls which are mechanically integral with multifunctional controls having non-electrical outputs; - using NTC or PTC thermistors and to discrete thermistors, requirements for which are contained in Annex J; - that are mechanically or electrically operated, responsive to or controlling such characteristics as temperature, pressure, passage of time, humidity, light, electrostatic effects, flow, or liquid level, current, voltage, acceleration, or combinations thereof; - as well as manual controls when such are electrically and/or mechanically integral with automatic controls. NOTE 3 Requirements for manually actuated mechanical switches not forming part of an automatic control are contained in IEC 61058-1-1. This document is applicable - to a complete burner control system; - to a separate programming unit; - to a separate electronic high-voltage ignition source; - to a separate flame detector, and - to a separate high-temperature operation (HTO) detector. - to a burner control system intended to be used in warm air heating appliances (furnaces) where the appliance is equipped with an electromechanical differential pressure control to monitor the difference of the combustion air pressure (Type 2.AL). This pressure control provides a switch as an alternative to one of the two switching elements to directly de-energize the safety relevant terminals. This document does not apply to thermoelectric flame supervision controls; thermoelectric flame supervision controls are covered by ISO 23551-6:2021. This document also applies to electrical burner control systems intended exclusively for industrial process applications e.g. those applications covered by ISO TC 244 (ISO 13577 series). This document applies to controls powered by primary or secondary batteries, requirements for which are contained within the standard. This document applies to - the inherent safety of automatic electrical burner control systems, and - functional safety of automatic electrical burner control systems, - automatic electrical burner control systems where the performance (for example the effect of EMC phenomena) of the product can impair the overall safety and perfo

  • Standard
    59 pages
    English language
    e-Library read for
    1 day

The contents of the corrigendum of March 2023 have been included in this copy.

  • Amendment
    29 pages
    English language
    e-Library read for
    1 day

IEC 60947-6-1:2026 is available as IEC 60947-6-1:2026 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition. IEC 60947-6-1:2026 applies to transfer switching equipment (TSE), to be used in power systems for ensuring the continuity of the supply and allowing the energy management of the installation, by transferring a load between power supply sources, the rated voltage of which does not exceed 1 000 V AC or 1 500 V DC. Specific requirements for bypass/isolation transfer switch equipment are given in Annex C, ATSE having closed transition capability are given in Annex D, stand-alone ATS controllers are given in Annex E, and TSE for electric driven fire pump controllers are given in Annex F. It covers: - manually operated transfer switching equipment (MTSE); - remotely operated transfer switching equipment (RTSE); - automatic transfer switching equipment (ATSE), including the controller; - stand-alone ATS controllers; - bypass/isolation transfer switch equipment (BTSE); - ATSE having closed transition capability; - fire pump TSE. It does not cover: - TSE configurations that are not fully manufacturer type tested or marked according to this document as a complete transfer switch; - auxiliary contacts (for guidance, see IEC 60947-5-1); - transfer switches used in explosive atmospheres (for guidance, see IEC 60079 (all parts)); - embedded software design (for guidance, see IEC TR 63201); - cybersecurity aspects (for guidance, see IEC 63208); - TSE rated for direct-on-line starting asynchronous motor of design NE and HE, according to IEC 60034-12. (for guidance, see AC-3e utilisation category according to IEC 60947 4 1); - other types of TSE under consideration including overlapping neutral TSE, multi-source TSE (i.e. TSE with more than two sources of supply), TSE with load-shedding functions, bus-tie TSE, and hybrid TSE; - static transfer switches covered by IEC 62310 series. This fourth edition cancels and replaces the third edition published in 2021. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - clarification of scope; - clarification of terms and definitions; - Annex C for Bypass/Isolation Transfer Switch Equipment; - Annex D for ATSE having closed transition capability; - Annex E for Stand-alone ATS controller; - Annex F for TSE used with electric driven fire pump control equipment.

  • Standard
    102 pages
    English language
    e-Library read for
    1 day

The contents of the corrigendum of March 2023 have been included in this copy.

  • Amendment
    29 pages
    English language
    e-Library read for
    1 day

This part of EN 61326 is a product family standard specifying requirements for immunity and emissions regarding electromagnetic compatibility (EMC) for electrical equipment, operating from a supply or battery of less than 1 000 V AC or 1 500 V DC or from the circuit being measured. Equipment intended for professional, industrial-process, industrial-manufacturing and educational use is covered by this part. It includes equipment and computing devices for - measurement and test; - control; - LABORATORY use; - accessories intended for use with the above (such as sample handling equipment), intended to be used in industrial and non-industrial locations.

  • Draft
    16 pages
    English language
    e-Library read for
    1 day

IEC 62132-8:2026 specifies a method for measuring the immunity of an integrated circuit (IC) to radio frequency (RF) radiated electromagnetic disturbances using an IC stripline.
This edition includes the following significant technical changes with respect to the previous edition:
a) frequency range of 150 kHz to 3 GHz was deleted from the scope;
b) extension of upper usable frequency to 6 GHz or higher as long as the defined requirements are fulfilled.
This part of IEC 62132 is to be read in conjunction with IEC 62132-1.

  • Standard
    26 pages
    English language
    e-Library read for
    1 day

IEC 62132-8:2026 specifies a method for measuring the immunity of an integrated circuit (IC) to radio frequency (RF) radiated electromagnetic disturbances using an IC stripline. This edition includes the following significant technical changes with respect to the previous edition: a) frequency range of 150 kHz to 3 GHz was deleted from the scope; b) extension of upper usable frequency to 6 GHz or higher as long as the defined requirements are fulfilled. This part of IEC 62132 is to be read in conjunction with IEC 62132-1.

  • Standard
    26 pages
    English language
    e-Library read for
    1 day

IEC 60730-2-12:2025 applies to automatic electrically operated door locks
• for use in, on, or in association with equipment for household appliance and similar use, including equipment for heating, air-conditioning and similar applications;
NOTE 1 Throughout this document, the word "equipment" means "appliance and equipment" and "controls" means "door locks".
NOTE 2 Throughout this document, the word "door" means "door, cover or lid". The words "door lock" means "electrically operated door lock".
• for equipment that is used by the public, such as equipment intended to be used in shops, offices, hospitals, farms and commercial and industrial applications;
EXAMPLE 1 Controls for commercial catering, heating and air-conditioning equipment.
• that are AC or DC powered controls with a rated voltage not exceeding 690 V AC or 600 V DC;
• used in, on, or in association with equipment that use electricity, gas, oil, solid fuel, solar thermal energy, etc., or a combination thereof;
• utilized as part of a control system or controls which are mechanically integral with multifunctional controls having non-electrical outputs;
• using NTC or PTC thermistors and to discrete thermistors, requirements for which are contained in Annex J;
• that have electrical circuits and control circuits which are, for example, operated by bimetals, magnet coils, memory metals, pressure elements, temperature-sensitive expansion elements or electronic elements.
NOTE 3 Requirements for manually actuated mechanical switches not forming part of an automatic control are contained in IEC 61058-1-1.
This document applies to
- the inherent safety of electrically operated door locks, and
- functional safety of electrically operated door locks and safety related systems,
- electrically operated door locks where the performance (for example the effect of EMC phenomena) of the product can impair the overall safety and performance of the controlled system,
- the operating values, operating times, and operating sequences where such are associated with equipment safety.
This document specifies the requirements for construction, operation and testing of automatic electrical controls used in, on, or in association with an equipment.
This document does not
• apply to electrically operated door locks intended exclusively for industrial process applications unless explicitly mentioned in the relevant part 2 or the equipment standard. However, this document can be applied to evaluate automatic electrical controls intended specifically for industrial applications in cases where no relevant safety standard exists;
• take into account the response value of an automatic action of a control, if such a response value is dependent upon the method of mounting the control in the equipment. Where a response value is of significant purpose for the protection of the user, or surroundings, the value defined in the appropriate equipment standard or as determined by the manufacturer will apply;
• address the integrity of the output signal to the network devices, such as interoperability with other devices unless it has been evaluated as part of the control system.
This fourth edition cancels and replaces the third edition published in 2015. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
Adoption of IEC

  • Standard
    27 pages
    English language
    e-Library read for
    1 day

IEC 60730-2-12:2015(E) applies to electrically operated door locks for use in, on or in association with equipment, including equipment for heating, air-conditioning and similar applications. The equipment may use electricity, gas, oil, solid fuel, solar thermal energy, etc., or a combination thereof. This standard also applies to electrically operated door locks for equipment that may be used by the public, such as equipment intended to be used in shops, offices, hospitals, farms and commercial and industrial applications. This standard does not apply to electrically operated door locks intended exclusively for industrial process applications unless explicitly mentioned in the equipment standard. This standard does not apply to electrically operated door locks intended for security access applications. This part 2 is intended to be used in conjunction with IEC 60730-1. It was established on the basis of the fifth edition (2013) of that publication. Consideration may be given to future editions of, or amendments to, IEC 60730-1. This third edition cancels and replaces the second edition published in 2005.  This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- aligns the text with IEC 60730-1, Edition 5;
- modifies requirements for Class B control function (H.27.1.2.2);
- modifies requirements for Class C control function (H.27.1.2.3) and
- modifies requirements for faults during safety shut-down.
Key words: Locks, Door Locks, Control Systems

  • Standard
    24 pages
    English language
    e-Library read for
    1 day

IEC 60730-2-12:2025 applies to automatic electrically operated door locks • for use in, on, or in association with equipment for household appliance and similar use, including equipment for heating, air-conditioning and similar applications; NOTE 1 Throughout this document, the word "equipment" means "appliance and equipment" and "controls" means "door locks". NOTE 2 Throughout this document, the word "door" means "door, cover or lid". The words "door lock" means "electrically operated door lock". • for equipment that is used by the public, such as equipment intended to be used in shops, offices, hospitals, farms and commercial and industrial applications; EXAMPLE 1 Controls for commercial catering, heating and air-conditioning equipment. • that are AC or DC powered controls with a rated voltage not exceeding 690 V AC or 600 V DC; • used in, on, or in association with equipment that use electricity, gas, oil, solid fuel, solar thermal energy, etc., or a combination thereof; • utilized as part of a control system or controls which are mechanically integral with multifunctional controls having non-electrical outputs; • using NTC or PTC thermistors and to discrete thermistors, requirements for which are contained in Annex J; • that have electrical circuits and control circuits which are, for example, operated by bimetals, magnet coils, memory metals, pressure elements, temperature-sensitive expansion elements or electronic elements. NOTE 3 Requirements for manually actuated mechanical switches not forming part of an automatic control are contained in IEC 61058-1-1. This document applies to - the inherent safety of electrically operated door locks, and - functional safety of electrically operated door locks and safety related systems, - electrically operated door locks where the performance (for example the effect of EMC phenomena) of the product can impair the overall safety and performance of the controlled system, - the operating values, operating times, and operating sequences where such are associated with equipment safety. This document specifies the requirements for construction, operation and testing of automatic electrical controls used in, on, or in association with an equipment. This document does not • apply to electrically operated door locks intended exclusively for industrial process applications unless explicitly mentioned in the relevant part 2 or the equipment standard. However, this document can be applied to evaluate automatic electrical controls intended specifically for industrial applications in cases where no relevant safety standard exists; • take into account the response value of an automatic action of a control, if such a response value is dependent upon the method of mounting the control in the equipment. Where a response value is of significant purpose for the protection of the user, or surroundings, the value defined in the appropriate equipment standard or as determined by the manufacturer will apply; • address the integrity of the output signal to the network devices, such as interoperability with other devices unless it has been evaluated as part of the control system. This fourth edition cancels and replaces the third edition published in 2015. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: Adoption of IEC

  • Standard
    27 pages
    English language
    e-Library read for
    1 day

IEC 61131-2:2017 specifies functional and electromagnetic compatibility requirements and related verification tests for any product where the primary purpose is performing the function of industrial control equipment, including PLC and/or PAC, and/or their associated peripherals which have as their intended use the control and command of machines, automated manufacturing and industrial processes, e.g. discrete, batch  and continuous control.
This fourth edition cancels and replaces the third edition published in 2007. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) removal of safety requirements and instead pointing to IEC 61010-2-201;
b) addition of negative logic digital inputs and outputs;
c) addition of Type 3-d digital input;
d) addition of 2,7 GHz to 6 GHz requirement for Radio-frequency electro-magnetic amplitude modulated immunity;
e) clarification of temperature testing;
f) clarification of type testing;
g) deprecation of certain technologies;
h) general update of multiple aspects of functionality and EMC;
i) reorganization of clauses to associate requirements and verifications more closely.

  • Standard
    112 pages
    English language
    e-Library read for
    1 day

IEC 61000-4-30:2025 defines the methods for measurement and interpretation of results for power quality parameters in AC power supply systems with a declared fundamental frequency of 50 Hz or 60 Hz. Measurement methods are described for each relevant parameter in terms that give reliable and repeatable results, regardless of the method’s implementation. This document addresses measurement methods for in-situ measurements. This document covers two classes of measurement methods (Class A and Class S). The classes of measurement are specified in Clause 4.
NOTE 1 In this document, “A” stands for “advanced” and “S” stands for “surveys”.
Measurement of parameters covered by this document is limited to conducted phenomena in power systems. The power quality parameters considered in this document are power frequency, magnitude of the supply voltage, flicker, supply voltage dips and swells, voltage interruptions, transient voltages, supply voltage unbalance, voltage harmonics and interharmonics, rapid voltage changes, mains communicating system (MCS) voltages, magnitude of current, harmonic currents, interharmonic currents and current unbalance. Emissions in the 2 kHz to 150 kHz range are considered in Annex C and Annex D. Depending on the purpose of the measurement, all or a subset of the phenomena on this list can be measured.
NOTE 2 Test methods for verifying compliance with this document can be found in IEC 62586-2.
NOTE 3 The effects of transducers inserted between the power system and the instrument are acknowledged but not addressed in detail in this document. Guidance about effects of transducers can be found IEC TR 61869-103.
This fourth edition cancels and replaces the third edition published in 2015. This edition constitutes a technical revision.This edition includes the following significant technical changes with respect to the previous edition:
a) IEC 61000-4-30:2015/AMD1:2021 and IEC 61000-4-30:2015/COR1:2016 were included.
b) The measurement method for rapid voltage changes (RVC) has been corrected and extended.
c) The measurement method for voltage events has been updated and extended.
d) Annex C was divided into 2 parts:
1) Annex C: The measurement method from IEC 61000-4-7:2002 and IEC 61000‑4‑7:2002/AMD1:2008, Annex B for conducted emissions in the 2 kHz to 9 kHz range has been separate
2) Annex D: A new measurement method for conducted emissions in the 9 kHz to 150 kHz range has been added.
e) Annex D (underdeviation and overdeviation parameters) was removed.
f) Annex E (Class B) was removed.

  • Standard
    99 pages
    English language
    e-Library read for
    1 day

IEC 61000-4-30:2025 defines the methods for measurement and interpretation of results for power quality parameters in AC power supply systems with a declared fundamental frequency of 50 Hz or 60 Hz. Measurement methods are described for each relevant parameter in terms that give reliable and repeatable results, regardless of the method’s implementation. This document addresses measurement methods for in-situ measurements. This document covers two classes of measurement methods (Class A and Class S). The classes of measurement are specified in Clause 4. NOTE 1 In this document, “A” stands for “advanced” and “S” stands for “surveys”. Measurement of parameters covered by this document is limited to conducted phenomena in power systems. The power quality parameters considered in this document are power frequency, magnitude of the supply voltage, flicker, supply voltage dips and swells, voltage interruptions, transient voltages, supply voltage unbalance, voltage harmonics and interharmonics, rapid voltage changes, mains communicating system (MCS) voltages, magnitude of current, harmonic currents, interharmonic currents and current unbalance. Emissions in the 2 kHz to 150 kHz range are considered in Annex C and Annex D. Depending on the purpose of the measurement, all or a subset of the phenomena on this list can be measured. NOTE 2 Test methods for verifying compliance with this document can be found in IEC 62586-2. NOTE 3 The effects of transducers inserted between the power system and the instrument are acknowledged but not addressed in detail in this document. Guidance about effects of transducers can be found IEC TR 61869-103. This fourth edition cancels and replaces the third edition published in 2015. This edition constitutes a technical revision.This edition includes the following significant technical changes with respect to the previous edition: a) IEC 61000-4-30:2015/AMD1:2021 and IEC 61000-4-30:2015/COR1:2016 were included. b) The measurement method for rapid voltage changes (RVC) has been corrected and extended. c) The measurement method for voltage events has been updated and extended. d) Annex C was divided into 2 parts: 1) Annex C: The measurement method from IEC 61000-4-7:2002 and IEC 61000‑4‑7:2002/AMD1:2008, Annex B for conducted emissions in the 2 kHz to 9 kHz range has been separate 2) Annex D: A new measurement method for conducted emissions in the 9 kHz to 150 kHz range has been added. e) Annex D (underdeviation and overdeviation parameters) was removed. f) Annex E (Class B) was removed.

  • Standard
    99 pages
    English language
    e-Library read for
    1 day

This part of CISPR 16 specifies the characteristics and performance of equipment for the measurement of radiated disturbances in the frequency range 9 kHz to 18 GHz. Specifications for antennas and test sites are included.
NOTE In accordance with IEC Guide 107 [1], 1 CISPR 16-1-4 is a basic EMC publication for use by product committees of the IEC. As stated in Guide 107, product committees are responsible for determining the applicability of the EMC standard. CISPR and its sub-committees are prepared to cooperate with product committees in the evaluation of the value of particular EMC tests for specific products.
The requirements of this publication apply at all frequencies and for all levels of radiated disturbances within the CISPR indicating range of the measuring equipment.
Methods of measurement are covered in CISPR 16-2-3, further information on radio disturbance is given in CISPR TR 16-3 [2], and uncertainties, statistics, and limit modelling are covered in CISPR 16-4 series.

  • Standard
    172 pages
    English language
    e-Library read for
    1 day

IEC 61131-2:2017 specifies functional and electromagnetic compatibility requirements and related verification tests for any product where the primary purpose is performing the function of industrial control equipment, including PLC and/or PAC, and/or their associated peripherals which have as their intended use the control and command of machines, automated manufacturing and industrial processes, e.g. discrete, batch and continuous control. This fourth edition cancels and replaces the third edition published in 2007. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) removal of safety requirements and instead pointing to IEC 61010-2-201; b) addition of negative logic digital inputs and outputs; c) addition of Type 3-d digital input; d) addition of 2,7 GHz to 6 GHz requirement for Radio-frequency electro-magnetic amplitude modulated immunity; e) clarification of temperature testing; f) clarification of type testing; g) deprecation of certain technologies; h) general update of multiple aspects of functionality and EMC; i) reorganization of clauses to associate requirements and verifications more closely.

  • Standard
    112 pages
    English language
    e-Library read for
    1 day

This part of CISPR 16 specifies the characteristics and performance of equipment for the measurement of radiated disturbances in the frequency range 9 kHz to 18 GHz. Specifications for antennas and test sites are included.
NOTE In accordance with IEC Guide 107 [1], 1 CISPR 16-1-4 is a basic EMC publication for use by product committees of the IEC. As stated in Guide 107, product committees are responsible for determining the applicability of the EMC standard. CISPR and its sub-committees are prepared to cooperate with product committees in the evaluation of the value of particular EMC tests for specific products.
The requirements of this publication apply at all frequencies and for all levels of radiated disturbances within the CISPR indicating range of the measuring equipment.
Methods of measurement are covered in CISPR 16-2-3, further information on radio disturbance is given in CISPR TR 16-3 [2], and uncertainties, statistics, and limit modelling are covered in CISPR 16-4 series.

  • Standard
    172 pages
    English language
    e-Library read for
    1 day

IEC 60730-2-11:2025 applies to energy regulators
• for use in, on, or in association with equipment for household appliance and similar use;
NOTE 1 Throughout this document, the word "equipment" means "appliance and equipment" and "controls" means "energy regulators".
• for equipment that is used by the public, such as equipment intended to be used in shops, offices, hospitals, farms and commercial and industrial applications;
EXAMPLE 1  Energy regulators for commercial catering, heating and air-conditioning equipment.
• that are smart enabled energy regulators;
EXAMPLE 2 Smart grid control, remote interfaces/control of energy-consuming equipment including computer or smart phone.
• that are AC or DC powered controls with a rated voltage not exceeding 690 V AC or 600 V DC;
• used in, on, or in association with equipment that use electricity, gas, oil, solid fuel, solar thermal energy, etc., or a combination thereof;
• utilized as part of a control system or controls which are mechanically integral with multifunctional controls having non-electrical outputs;
• using NTC or PTC thermistors and to discrete thermistors, requirements for which are contained in Annex J;
• that are mechanically or electrically operated, responsive to or controlling such characteristics as temperature, pressure, passage of time, humidity, light, electrostatic effects, flow, or liquid level, current, voltage, acceleration, or combinations thereof;
• as well as manual controls when such are electrically and/or mechanically integral with automatic controls.
NOTE 2 Requirements for manually actuated mechanical switches not forming part of an automatic control are contained in IEC 61058-1-1.
This document applies to
- the inherent safety of energy regulators, and
- functional safety of energy regulators of low complexity safety related systems and controls,
- controls where the performance (for example the effect of EMC phenomena) of the product can impair the overall safety and performance of the controlled system,
- the operating values, operating times, and operating sequences where such are associated with equipment safety.
- manual energy regulators which are electrically and/or mechanically integral with automatic controls.
- energy regulators incorporating electronic devices, requirements for which are contained in Annex H.
- the electrical and functional safety of controls capable of receiving and responding to communications signals, including signals for power billing rate and demand response.
The signals can be transmitted to or received from external units being part of the control (wired), or to and from external units which are not part of the control (wireless) under test.
This document specifies the requirements for construction, operation and testing of automatic energy regulators used in, on, or in association with an equipment.
This document does not
• apply to automatic energy regulators intended exclusively for industrial process applications unless explicitly mentioned in the relevant part 2 or the equipment standard. However, this document can be applied to evaluate automatic energy regulators intended specifically for industrial applications in cases where no relevant safety standard exists.
• take into account the response value of an automatic action of an energy regulator, if such a response value is dependent upon the method of mounting the energy regulator

  • Standard
    24 pages
    English language
    e-Library read for
    1 day

IEC 60730-2-6:2025 applies to automatic electrical pressure sensing controls
• for use in, on, or in association with equipment for household appliance and similar use;
NOTE 1 Throughout this document, the word "equipment" means "appliance and equipment" and "controls" means "pressure sensing controls".
• for building automation within the scope of ISO 16484 series and IEC 63044 series (HBES/BACS);
EXAMPLE 1 Independently mounted automatic electrical pressure sensing controls, controls in smart grid systems and controls for building automation systems within the scope of ISO 16484-2.
• for equipment that is used by the public, such as equipment intended to be used in shops, offices, hospitals, farms and commercial and industrial applications;
EXAMPLE 2 Automatic electrical pressure sensing controls for commercial catering, heating and air-conditioning equipment.
• that are smart enabled automatic electrical pressure sensing controls;
EXAMPLE 3 Smart grid automatic electrical pressure sensing controls, remote interfaces/control of energy-consuming equipment including computer or smart phone.
• that are AC or DC powered controls with a rated voltage not exceeding 690 V AC or 600 V DC;
• used in, on, or in association with equipment that use electricity, gas, oil, solid fuel, solar thermal energy, etc., or a combination thereof;
• utilized as part of a control system or controls which are mechanically integral with multifunctional controls having non-electrical outputs;
• using NTC or PTC thermistors and to discrete thermistors, requirements for which are contained in Annex J;
• that are mechanically or electrically operated, responsive to or controlling a pressure or vacuum;
• as well as manual controls when such are electrically and/or mechanically integral with automatic controls.
NOTE 2 Requirements for manually actuated mechanical switches not forming part of an automatic control are contained in IEC 61058-1-1.
This document is also applicable to individual pressure sensing controls utilized as part of a control system or pressure sensing controls which are mechanically integral with multi-functional controls having non-electrical outputs.
This document is also applicable to pressure sensing controls for appliances within the scope of IEC 60335-1.
This document applies to
- the inherent safety of pressure sensing controls, and
- functional safety of pressure sensing controls and safety related systems,
- pressure sensing controls where the performance (for example the effect of EMC phenomena) of the product can impair the overall safety and performance of the controlled system,
- the operating values, operating times, and operating sequences where such are associated with equipment safety.
This document specifies the requirements for construction, operation and testing of automatic electrical controls used in, on, or in association with an equipment.
This document does not
• apply to pressure sensing controls intended exclusively for industrial process applications unless explicitly mentioned in the relevant part 2 or the equipment standard. However, this document can be applied to evaluate automatic electrical controls intended specifically for industrial applications in cases where no relevant safety standard exists;
• take into account the response value of an automatic action of a pressure sensing control, if such a response value is dependent upon

  • Standard
    40 pages
    English language
    e-Library read for
    1 day

IEC 60730-2-6:2025 applies to automatic electrical pressure sensing controls • for use in, on, or in association with equipment for household appliance and similar use; NOTE 1 Throughout this document, the word "equipment" means "appliance and equipment" and "controls" means "pressure sensing controls". • for building automation within the scope of ISO 16484 series and IEC 63044 series (HBES/BACS); EXAMPLE 1 Independently mounted automatic electrical pressure sensing controls, controls in smart grid systems and controls for building automation systems within the scope of ISO 16484-2. • for equipment that is used by the public, such as equipment intended to be used in shops, offices, hospitals, farms and commercial and industrial applications; EXAMPLE 2 Automatic electrical pressure sensing controls for commercial catering, heating and air-conditioning equipment. • that are smart enabled automatic electrical pressure sensing controls; EXAMPLE 3 Smart grid automatic electrical pressure sensing controls, remote interfaces/control of energy-consuming equipment including computer or smart phone. • that are AC or DC powered controls with a rated voltage not exceeding 690 V AC or 600 V DC; • used in, on, or in association with equipment that use electricity, gas, oil, solid fuel, solar thermal energy, etc., or a combination thereof; • utilized as part of a control system or controls which are mechanically integral with multifunctional controls having non-electrical outputs; • using NTC or PTC thermistors and to discrete thermistors, requirements for which are contained in Annex J; • that are mechanically or electrically operated, responsive to or controlling a pressure or vacuum; • as well as manual controls when such are electrically and/or mechanically integral with automatic controls. NOTE 2 Requirements for manually actuated mechanical switches not forming part of an automatic control are contained in IEC 61058-1-1. This document is also applicable to individual pressure sensing controls utilized as part of a control system or pressure sensing controls which are mechanically integral with multi-functional controls having non-electrical outputs. This document is also applicable to pressure sensing controls for appliances within the scope of IEC 60335-1. This document applies to - the inherent safety of pressure sensing controls, and - functional safety of pressure sensing controls and safety related systems, - pressure sensing controls where the performance (for example the effect of EMC phenomena) of the product can impair the overall safety and performance of the controlled system, - the operating values, operating times, and operating sequences where such are associated with equipment safety. This document specifies the requirements for construction, operation and testing of automatic electrical controls used in, on, or in association with an equipment. This document does not • apply to pressure sensing controls intended exclusively for industrial process applications unless explicitly mentioned in the relevant part 2 or the equipment standard. However, this document can be applied to evaluate automatic electrical controls intended specifically for industrial applications in cases where no relevant safety standard exists; • take into account the response value of an automatic action of a pressure sensing control, if such a response value is dependent upon

  • Standard
    40 pages
    English language
    e-Library read for
    1 day

IEC 60730-2-11:2025 applies to energy regulators • for use in, on, or in association with equipment for household appliance and similar use; NOTE 1 Throughout this document, the word "equipment" means "appliance and equipment" and "controls" means "energy regulators". • for equipment that is used by the public, such as equipment intended to be used in shops, offices, hospitals, farms and commercial and industrial applications; EXAMPLE 1 Energy regulators for commercial catering, heating and air-conditioning equipment. • that are smart enabled energy regulators; EXAMPLE 2 Smart grid control, remote interfaces/control of energy-consuming equipment including computer or smart phone. • that are AC or DC powered controls with a rated voltage not exceeding 690 V AC or 600 V DC; • used in, on, or in association with equipment that use electricity, gas, oil, solid fuel, solar thermal energy, etc., or a combination thereof; • utilized as part of a control system or controls which are mechanically integral with multifunctional controls having non-electrical outputs; • using NTC or PTC thermistors and to discrete thermistors, requirements for which are contained in Annex J; • that are mechanically or electrically operated, responsive to or controlling such characteristics as temperature, pressure, passage of time, humidity, light, electrostatic effects, flow, or liquid level, current, voltage, acceleration, or combinations thereof; • as well as manual controls when such are electrically and/or mechanically integral with automatic controls. NOTE 2 Requirements for manually actuated mechanical switches not forming part of an automatic control are contained in IEC 61058-1-1. This document applies to - the inherent safety of energy regulators, and - functional safety of energy regulators of low complexity safety related systems and controls, - controls where the performance (for example the effect of EMC phenomena) of the product can impair the overall safety and performance of the controlled system, - the operating values, operating times, and operating sequences where such are associated with equipment safety. - manual energy regulators which are electrically and/or mechanically integral with automatic controls. - energy regulators incorporating electronic devices, requirements for which are contained in Annex H. - the electrical and functional safety of controls capable of receiving and responding to communications signals, including signals for power billing rate and demand response. The signals can be transmitted to or received from external units being part of the control (wired), or to and from external units which are not part of the control (wireless) under test. This document specifies the requirements for construction, operation and testing of automatic energy regulators used in, on, or in association with an equipment. This document does not • apply to automatic energy regulators intended exclusively for industrial process applications unless explicitly mentioned in the relevant part 2 or the equipment standard. However, this document can be applied to evaluate automatic energy regulators intended specifically for industrial applications in cases where no relevant safety standard exists. • take into account the response value of an automatic action of an energy regulator, if such a response value is dependent upon the method of mounting the energy regulator

  • Standard
    24 pages
    English language
    e-Library read for
    1 day

IEC 60947-5-7:2024 states the requirements for proximity devices that correspond to the scope of IEC 60947-5-2:2019 with analog output (PDAO) and/or a digital output to transmit a corresponding digital value representing the detected sensing input. These devices can provide additional parameters.
This second edition cancels and replaces the first edition published in 2003. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) New structure;
b) Update and expansion of definitions on analog output properties;
c) Expanded performance requirements on analog output;
d) Update and new normative references;
e) Update of EMC requirements;
f) Harmonization with IEC 62828 series;
g) Harmonization with IEC 62683 and IEC 61987 definitions;
h) Harmonization with IEC 61131-2 requirements;
i) Update of the Annex A (former Annex G), Example of the determination of the conformity;
j) New Annex B, Overview tests and influence quantities;
k) New Annex C, Additional requirements for proximity switches with analog output incorporating a built-in communication interface complying with IEC 61131-9;
l) New Annex D, Main characteristics for proximity devices with analog output.

  • Standard
    49 pages
    English language
    e-Library read for
    1 day

IEC 60947-4-1:2023 is applicable to the following equipment:
- electromechanical contactors and starters including motor protective switching devices (MPSD and IMPSD);
- actuators of contactor relays;
- contacts dedicated exclusively to the coil circuit of the contactor or the contactor relay;
- dedicated accessories (e.g. dedicated wiring, dedicated latch accessory);
intended to be connected to distribution circuits, motors circuits and other load circuits, the rated voltage of which does not exceed 1 000 V AC or 1 500 V DC.
This fifth edition cancels and replaces the fourth edition published in 2018. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) objective in the scope;
b) instantaneous only motor protective switching device IMPSD (3.5.33);
c) kinds of equipment (5.2.1);
d) methods of overload protection of motors (5.2.6);
e) adoption of the AC-7d from IEC 61095:2023 (in 5.4.2);
f) separately mounted overload relay of a starter (in 5.7.3 b));
g) starter and contactor suitable for use downstream to basic drive module (6.1.2 w));
h) reference to IEC TS 63058 for environmental aspects (in 6.4);
i) wiring subject to movement (in 8.1.3);
j) use of voltage transient limiting device (8.1.18);
k) accessible parts subject to temperature limits (in 8.2.2.3);
l) reference to Annex X of IEC 60947-1:2020 for the co-ordination of MPSD with SCPD (8.2.5.4);
m) reference to IEC TR 63216 with different EMC environments (8.3.1);
n) reference to IEC TR 63201 for the embedded software design (8.4);
o) reference to IEC TS 63208 for cybersecurity aspects (8.5);
p) update and completion of the measurement method of the power consumption of the electromagnet (9.3.3.2.1.2);
q) update of Annex C including rational about AC-3e;
r) determination of the critical load current for photovoltaic applications (M.8.7).

  • Standard
    191 pages
    English language
    e-Library read for
    1 day

IEC 61095:2023 is available as IEC 61095:2023 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.

IEC 61095:2023 applies to electromechanical air break contactors for household and similar purposes provided with main contacts intended to be connected to circuits the rated voltage of which does not exceed 440 V AC (between phases) with rated operational currents less than or equal to 63 A for utilization category AC-7a, and 32 A for utilization categories AC‑7b, AC‑7c and AC-7d (expressed in rated power), and rated conditional short-circuit current less than or equal to 6 kA. This third edition cancels and replaces the second edition published in 2009. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) addition of requirements for screwless terminals;
b) addition of requirements for the switching of LED lamps. Contactors for domestic and similar applications can be used for controlling lighting loads which is increasingly using LED lamp technology. A specific category for contactors is created: AC-7d. Requirements and tests are added to cover this market development, mainly for making and breaking and conventional operational performance;
c) addition of requirements for contactors with electronically controlled electromagnet. Household contactors with electronically controlled electromagnet are available for years on the market. To fully cover such device, requirements and tests are added, dealing mainly with operating limits, behaviour in abnormal conditions, breakdown of components, EMC tests, etc.
d) embedded software. More and more contactors are incorporating electronic circuits with embedded software. A reference is provided to guide the design of the software.

  • Standard
    146 pages
    English language
    e-Library read for
    1 day

IEC 61326-2-6:2025 applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of IN VITRO DIAGNOSTIC MEDICAL ELECTRICAL EQUIPMENT (IVD MEE). This part of IEC 61326 applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of IVD MEE in the presence of electromagnetic disturbances and to electromagnetic disturbances emitted by IVD MEE.
BASIC SAFETY with regard to electromagnetic disturbances is applicable to all IVD MEE.
NOTE 1 Performance with respect to electromagnetic disturbances other than ESSENTIAL PERFORMANCE is the subject of IEC 61326-1:2020
NOTE 2 IT equipment can be a part of an IVD MEE, if it is required to maintain BASIC SAFETY or ESSENTIAL PERFORMANCE.
This edition includes the following significant technical changes with respect to the previous edition:
- Update of the document with respect to test levels and documentation.

  • Standard
    36 pages
    English language
    e-Library read for
    1 day

IEC 60931-1:2025 is applicable to both non-self-healing capacitor units and non-self-healing capacitor banks intended to be used, particularly, for power-factor correction of AC power systems having a rated voltage up to and including 1 000 V and frequencies 15 Hz to 60 Hz. This document also applies to capacitors intended for use in power filter circuits.

  • Standard
    43 pages
    English language
    e-Library read for
    1 day

IEC 60947-4-1:2023 is applicable to the following equipment: - electromechanical contactors and starters including motor protective switching devices (MPSD and IMPSD); - actuators of contactor relays; - contacts dedicated exclusively to the coil circuit of the contactor or the contactor relay; - dedicated accessories (e.g. dedicated wiring, dedicated latch accessory); intended to be connected to distribution circuits, motors circuits and other load circuits, the rated voltage of which does not exceed 1 000 V AC or 1 500 V DC. This fifth edition cancels and replaces the fourth edition published in 2018. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) objective in the scope; b) instantaneous only motor protective switching device IMPSD (3.5.33); c) kinds of equipment (5.2.1); d) methods of overload protection of motors (5.2.6); e) adoption of the AC-7d from IEC 61095:2023 (in 5.4.2); f) separately mounted overload relay of a starter (in 5.7.3 b)); g) starter and contactor suitable for use downstream to basic drive module (6.1.2 w)); h) reference to IEC TS 63058 for environmental aspects (in 6.4); i) wiring subject to movement (in 8.1.3); j) use of voltage transient limiting device (8.1.18); k) accessible parts subject to temperature limits (in 8.2.2.3); l) reference to Annex X of IEC 60947-1:2020 for the co-ordination of MPSD with SCPD (8.2.5.4); m) reference to IEC TR 63216 with different EMC environments (8.3.1); n) reference to IEC TR 63201 for the embedded software design (8.4); o) reference to IEC TS 63208 for cybersecurity aspects (8.5); p) update and completion of the measurement method of the power consumption of the electromagnet (9.3.3.2.1.2); q) update of Annex C including rational about AC-3e; r) determination of the critical load current for photovoltaic applications (M.8.7).

  • Standard
    191 pages
    English language
    e-Library read for
    1 day

IEC 60947-5-7:2024 states the requirements for proximity devices that correspond to the scope of IEC 60947-5-2:2019 with analog output (PDAO) and/or a digital output to transmit a corresponding digital value representing the detected sensing input. These devices can provide additional parameters. This second edition cancels and replaces the first edition published in 2003. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) New structure; b) Update and expansion of definitions on analog output properties; c) Expanded performance requirements on analog output; d) Update and new normative references; e) Update of EMC requirements; f) Harmonization with IEC 62828 series; g) Harmonization with IEC 62683 and IEC 61987 definitions; h) Harmonization with IEC 61131-2 requirements; i) Update of the Annex A (former Annex G), Example of the determination of the conformity; j) New Annex B, Overview tests and influence quantities; k) New Annex C, Additional requirements for proximity switches with analog output incorporating a built-in communication interface complying with IEC 61131-9; l) New Annex D, Main characteristics for proximity devices with analog output.

  • Standard
    49 pages
    English language
    e-Library read for
    1 day

IEC 61095:2023 is available as IEC 61095:2023 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 61095:2023 applies to electromechanical air break contactors for household and similar purposes provided with main contacts intended to be connected to circuits the rated voltage of which does not exceed 440 V AC (between phases) with rated operational currents less than or equal to 63 A for utilization category AC-7a, and 32 A for utilization categories AC‑7b, AC‑7c and AC-7d (expressed in rated power), and rated conditional short-circuit current less than or equal to 6 kA. This third edition cancels and replaces the second edition published in 2009. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) addition of requirements for screwless terminals; b) addition of requirements for the switching of LED lamps. Contactors for domestic and similar applications can be used for controlling lighting loads which is increasingly using LED lamp technology. A specific category for contactors is created: AC-7d. Requirements and tests are added to cover this market development, mainly for making and breaking and conventional operational performance; c) addition of requirements for contactors with electronically controlled electromagnet. Household contactors with electronically controlled electromagnet are available for years on the market. To fully cover such device, requirements and tests are added, dealing mainly with operating limits, behaviour in abnormal conditions, breakdown of components, EMC tests, etc. d) embedded software. More and more contactors are incorporating electronic circuits with embedded software. A reference is provided to guide the design of the software.

  • Standard
    146 pages
    English language
    e-Library read for
    1 day

IEC 60931-1:2025 is applicable to both non-self-healing capacitor units and non-self-healing capacitor banks intended to be used, particularly, for power-factor correction of AC power systems having a rated voltage up to and including 1 000 V and frequencies 15 Hz to 60 Hz. This document also applies to capacitors intended for use in power filter circuits.

  • Standard
    43 pages
    English language
    e-Library read for
    1 day

IEC 61326-2-6:2025 applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of IN VITRO DIAGNOSTIC MEDICAL ELECTRICAL EQUIPMENT (IVD MEE). This part of IEC 61326 applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of IVD MEE in the presence of electromagnetic disturbances and to electromagnetic disturbances emitted by IVD MEE. BASIC SAFETY with regard to electromagnetic disturbances is applicable to all IVD MEE. NOTE 1 Performance with respect to electromagnetic disturbances other than ESSENTIAL PERFORMANCE is the subject of IEC 61326-1:2020 NOTE 2 IT equipment can be a part of an IVD MEE, if it is required to maintain BASIC SAFETY or ESSENTIAL PERFORMANCE. This edition includes the following significant technical changes with respect to the previous edition: - Update of the document with respect to test levels and documentation.

  • Standard
    36 pages
    English language
    e-Library read for
    1 day

IEC 60730-2-8:2025 applies to electrically operated water valves
• for use in, on, or in association with equipment for household appliance and similar use;
NOTE 1 Throughout this document, the word "equipment" means "appliance and equipment" and "control" means "electrically operated water valve".
EXAMPLE 1 Electrically operated water valves for appliances within the scope of IEC 60335.
• for building automation within the scope of ISO 16484 series and IEC 63044 series (HBES/BACS);
EXAMPLE 2 Independently mounted water valves, controls in smart grid systems and controls for building automation systems within the scope of ISO 16484-2.
• for equipment that is used by the public, such as equipment intended to be used in shops, offices, hospitals, farms and commercial and industrial applications;
EXAMPLE 3 Electrically operated water valves for commercial catering, heating and air-conditioning equipment.
• that are smart enabled electrically operated water valves;
EXAMPLE 4 Smart grid control, remote interfaces and controls of energy-consuming equipment including computer or smart phone.
• that are AC or DC powered electrically operated water valves with a rated voltage not exceeding 690 V AC or 600 V DC;
• used in, on, or in association with equipment that uses electricity, gas, oil, solid fuel, solar thermal energy, etc., or a combination thereof;
• utilized as part of a control system or controls which are mechanically integral with multifunctional controls having non-electrical outputs;
• using NTC or PTC thermistors and to discrete thermistors, requirements for which are contained in Annex J of Part 1;
• responsive to or controlling such characteristics as temperature, pressure, passage of time, humidity, light, electrostatic effects, flow, or liquid level, current, voltage, acceleration, or combinations thereof;
• in which actuators and valve bodies are designed to be fitted to each other.
• as well as manual controls when such are electrically or mechanically integral with automatic controls.
NOTE 2 Requirements for manually actuated mechanical switches not forming part of an automatic control are contained in IEC 61058-1-1.
This document applies to
- the inherent safety of electrically operated water valves, and
- functional safety of electrically operated water valves and safety related systems,
- controls where the performance (for example the effect of EMC phenomena) of the product can impair the overall safety and performance of the controlled system,
- the operating values, operating times, and operating sequences where such are associated with equipment safety.
This document specifies the requirements for construction, operation and testing of electrically operated water valves used in, on, or in association with an equipment.
This document contains requirements for electrical features of water valves and requirements for mechanical features of valves that affect their intended operation.
This document does not
• apply to electrically operated water valves intended exclusively for industrial process applications unless explicitly mentioned in the relevant Part 2 or the equipment standard. However, this document can be applied to evaluate automatic electrical controls intended specifically for industrial applications in cases where no relevant safety standard exists.
• apply to
- electrically operated water valves of nomi

  • Standard
    52 pages
    English language
    e-Library read for
    1 day

This document applies to industrial, scientific and medical electrical equipment operating in the
frequency range 0 Hz to 400 GHz and to domestic and similar appliances designed to generate
and/or use locally radio-frequency energy.
This document covers emission requirements related to radio-frequency (RF) disturbances in
the frequency range of 9 kHz to 400 GHz.
For ISM RF applications in the meaning of the definition found in the ITU Radio Regulations
(2020) (see Definition 3.1.18), this document covers emission requirements related to radiofrequency
disturbances in the frequency range of 9 kHz to 18 GHz.
ISM equipment which incorporates radio transmit/receive functions (host equipment with radio
functionality) is included in the scope of this document, see Annex F. However, the emission
requirements in this document are not intended to be applicable to the intentional transmissions
from a radio transmitter as defined by the ITU including their spurious emissions.
NOTE 1 This exclusion only applies to emissions from the intentional radio transmitter. However, combination
emissions, for example emissions resulting from intermodulation between the radio and the non-radio subassemblies
of the ISM equipment, are not subject to this exclusion.
NOTE 2 Emission requirements for induction cooking appliances are specified in CISPR 14-1 [1]1.
Requirements for ISM RF lighting equipment and UV irradiators operating at frequencies within
the ISM frequency bands defined by the ITU Radio Regulations are contained in this document.
Robots used for industrial, scientific and medical applications are in the scope of this document.
EXAMPLE Welding robots, spraying robots, handling robots, processing robots, assembly robots, medical robots,
education and experimental robots. A comprehensive list of robots in the scope of this document is given on the IEC
EMC zone.
NOTE 3 Flying robots, domestic helper robots, toy robots and entertainment robots are examples of robots in the
scope of other CISPR standards.
Equipment covered by other CISPR product and product family emission standards are
excluded from the scope of this document.

  • Standard
    99 pages
    English language
    e-Library read for
    1 day

This document covers internal arc-fault control devices, hereinafter referred to as IACD, which
are intended to:
- detect internal arc-faults in low-voltage switchgear and controlgear assemblies, by
processing (at a minimum) the optical effect of an internal arc-fault, and
- operate mitigation device (either external or combined)
in order to minimize the effects of the internal arc-fault (see Figure 1).
For the purpose of this document the terms "light" or "optical" covers more than visible spectra.
They may cover also, for example, infrared or ultraviolet electromagnetic radiations (see
Annex D).
For combined-type IACD, this document is considered in addition to the relevant product
standard for internal arc-fault mitigation devices (IARD per IEC TS 63107:2020). Compliance
to the relevant product standard is mandatory and cannot be claimed by testing to this document
alone.
NOTE 1 Low-voltage switchgear and controlgear assemblies are usually described by IEC 61439 series.
[Figure 1]
Therefore, this document covers the following:
- internal arc-fault control device (stand-alone, multifunction or combined);
- one or more associated sensor(s) used to detect optical effect of the internal arc-fault;
- sensor(s), sensing another physical effect, to confirm the fault;
- associated or combined mitigation device.
An IACD is not intended to trigger under normal operation of low-voltage switchgear and
controlgear (i.e. absence of internal arc-fault), including normal arcing associated with
operation of disconnecting and switching devices.
This document only covers the following methods:
- optical detection of the light caused by an internal arc-fault;
- optional confirmation of internal arc-fault by line current measurement.
Many different conductive materials could be used in LV assemblies (e.g. steel, copper,
aluminium). Nevertheless, tests specified in this document are deemed to represent the most
critical and challenging conditions for arc-detection and cover all combinations of conductive
materials.
NOTE 2 Compared to other materials (e.g. steel, aluminium), copper leads to a lower optical radiation energy.
The rated voltage of the assembly in which an IACD is installed does not exceed 1 000 V AC.
Such devices are designed to be operated and maintained by skilled persons only.
This document does not cover:
- DC internal arc-fault detection and control;
- overcurrent relays;
- AFDD (arc-fault detection devices) as defined by IEC 62606;
- guidance on installation within assemblies;
NOTE 3 The integration of an IACD into an assembly is described in IEC TS 63107.
- use with additional measures needed for installation and operation within explosive
atmospheres. These are given in IEC 60079 series documents;
- requirements for embedded software and firmware design rules; for this subject, the
manufacturer is responsible for taking additional safety measures;
NOTE 4 IEC TR 63201 describes rules for firmware and embedded software development preventing errors in
software.
- cybersecurity aspects; for this subject, the manufacturer is responsible for taking additional
safety measures;
NOTE 5 See IEC TS 63208.
- mobile applications.
NOTE 6 Even when addressing internal arc-fault mitigation devices, this document does not supersede any other
relevant product standard (e.g. IEC 60947-2 or IEC 60947-9-1).
NOTE 7 DC arcing fault phenomena are under consideration. Further investigation is needed to comprehend DC
arcing phenomena and required sensing.

  • Standard
    90 pages
    English language
    e-Library read for
    1 day

Frequently Asked Questions

An EU Directive is a legislative act of the European Union that sets out goals that all EU member states must achieve. However, it is up to each member state to devise their own laws on how to reach these goals through national transposition. Directives are used to harmonize laws across the EU, particularly for the functioning of the single market.

Directive 2014/30/EU covers "Directive 2014/30/EU of the European Parliament and of the Council of 26 February 2014 on the harmonisation of the laws of the Member States relating to electromagnetic compatibility (recast)". This legislation has harmonized European standards (hENs) that provide a presumption of conformity with its essential requirements. There are 1542 standards associated with this directive.

Harmonized standards under 2014/30/EU are European standards (ENs) developed by CEN, CENELEC, or ETSI in response to a mandate from the European Commission. When these standards are cited in the Official Journal of the European Union, products manufactured in conformity with them benefit from a presumption of conformity with the essential requirements of 2014/30/EU, facilitating CE marking and free movement within the European Economic Area.