27.060 - Burners. Boilers
ICS 27.060 Details
Burners. Boilers
Feuerungen. Brenner. Kessel
Bruleurs. Chaudieres
Gorilniki. Grelniki vode
General Information
e-Library Subscription
Create subscription and get permanent access to documents within 27.060 - Burners. Boilers
Currently subscription includes documents marked with .We are working on making all documents available within the subscription.
This document specifies the functional requirements relevant for design, materials, construction, testing, operation and maintenance of gas pressure control stations to ensure their reliability in terms of safety of the station itself and the downstream system and continuity of service.
This document is applicable for gas pressure control stations which are part of gas transmission or distribution systems for hydrogen, and hydrogen rich, and methane rich gases. Additional requirements in the case of gases heavier than air and/or toxic or corrosive gases are not covered by this document.
This document does not apply to gas pressure control stations in operation prior to the publication of this document. However, Annex D of this document can be used as guidance for the evaluation of stations in operation prior to the publication of this document, regarding the change of the type of gas, e.g. repurposing for the use with hydrogen.
The stations covered by this document have a maximum upstream operating pressure, which does not exceed 100 bar. For higher maximum upstream operating pressures, this document can be used as a guideline.
If the inlet pipework of the station is a service line and the maximum upstream operating pressure does not exceed 16 bar and the design flow rate is equal to 2000 kW based on the gross calorific value or less, EN 12279 applies.
This document contains the basic system requirements for gas pressure control stations. Requirements for individual components (valves, regulators, safety devices, pipes, etc.) or installation of the components are contained in the appropriate European Standards.
NOTE For combined control and measuring stations, the additional requirements of EN 1776 can apply.
The requirements in this document do not apply to the design and construction of auxiliary facilities such as sampling, calorimetering, odorization systems and density measuring. These facilities are covered by the appropriate European Standards, where existing, or applicable national standards.
The requirements of this document are based on good gas engineering practice under conditions normally encountered in the gas industry. Requirements for unusual conditions cannot be specifically provided for, nor are all engineering and construction details prescribed.
The objective of this document is to ensure the safe operation of such stations. This does not, however, relieve all concerned of the responsibility for taking the necessary care and applying effective quality and safety management during the design, construction, operation and maintenance.
- Draft49 pagesEnglish languagesale 10% offe-Library read for1 day
This document applies to shell boilers with volumes in excess of 2 l for the generation of steam and/or hot water at a maximum allowable pressure greater than 0,5 bar and with a temperature in excess of 110 °C.
For the purpose of this document the following pressurized parts are included:
— the shell boiler as one entity of pressure equipment including all the pressure parts from the feedwater/hot water inlet (including the inlet valve) up to and including the steam/hot water outlet (including the outlet valve or, if there is no valve, the first circumferential weld or flange downstream of the shell boiler or if applicable the outlet header);
— all superheaters, economizers and interconnecting piping;
— additionally, the piping that is connected to the boiler involved in services such as draining, venting, desuperheating, etc., up to the first isolating valve or, if there is no valve, the first circumferential weld or flange downstream of the shell boiler or if applicable the outlet header/piping.
This document does not apply to the following types of boilers and equipments:
a) water-tube boilers;
b) non stationary boilers, e.g. locomotive boilers;
c) thermal oil boilers;
d) boilers where the main pressure housing is made of cast material;
e) pumps, gaskets, etc;
f) brickwork setting and insulation, etc.
NOTE 1 Further information on shell boilers is given in Annex A.
NOTE 2 Stainless steel boilers are covered by EN 14222:2021.
- Standard32 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the following materials for the pressure bearing parts of shell boilers and equipment of shell boilers (e.g. valves), subjected to internal and external pressure including integral attachments (non pressure bearing parts):
— flat products (plate) and parts formed from flat products (e.g. shell, furnace, dished ends);
— tubes and parts formed from tubes (e.g. bending, elbows, reducers, fittings);
— forgings and cast products ;
— bolting materials;
— welding consumables.
- Standard17 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the following materials for the pressure bearing parts of shell boilers and equipment of shell boilers (e.g. valves), subjected to internal and external pressure including integral attachments (non pressure bearing parts):
— flat products (plate) and parts formed from flat products (e.g. shell, furnace, dished ends);
— tubes and parts formed from tubes (e.g. bending, elbows, reducers, fittings);
— forgings and cast products ;
— bolting materials;
— welding consumables.
- Standard17 pagesEnglish languagesale 10% offe-Library read for1 day
This document applies to shell boilers with volumes in excess of 2 l for the generation of steam and/or hot water at a maximum allowable pressure greater than 0,5 bar and with a temperature in excess of 110 °C.
For the purpose of this document the following pressurized parts are included:
— the shell boiler as one entity of pressure equipment including all the pressure parts from the feedwater/hot water inlet (including the inlet valve) up to and including the steam/hot water outlet (including the outlet valve or, if there is no valve, the first circumferential weld or flange downstream of the shell boiler or if applicable the outlet header);
— all superheaters, economizers and interconnecting piping;
— additionally, the piping that is connected to the boiler involved in services such as draining, venting, desuperheating, etc., up to the first isolating valve or, if there is no valve, the first circumferential weld or flange downstream of the shell boiler or if applicable the outlet header/piping.
This document does not apply to the following types of boilers and equipments:
a) water-tube boilers;
b) non stationary boilers, e.g. locomotive boilers;
c) thermal oil boilers;
d) boilers where the main pressure housing is made of cast material;
e) pumps, gaskets, etc;
f) brickwork setting and insulation, etc.
NOTE 1 Further information on shell boilers is given in Annex A.
NOTE 2 Stainless steel boilers are covered by EN 14222:2021.
- Standard32 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies requirements for electrically heated steam boilers manufactured from stainless steel specifically dedicated for generating steam for sterilizers and disinfectors.
This document covers only steam boilers that are heated by immersion heaters and which have a maximum allowable pressure (PS) of not greater than 6 bar, a maximum volume (V) of 1 000 litres and a product of PS ∙ V not greater than 3 000 bar ∙ l.
- Standard20 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies requirements for electrically heated steam boilers manufactured from stainless steel specifically dedicated for generating steam for sterilizers and disinfectors.
This document covers only steam boilers that are heated by immersion heaters and which have a maximum allowable pressure (PS) of not greater than 6 bar, a maximum volume (V) of 1 000 litres and a product of PS ∙ V not greater than 3 000 bar ∙ l.
- Standard20 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies the essential terms, constructional requirements, tests, energy assessment and marking of indirectly heated water storage tanks for primary water (buffer tanks), with a capacity not exceeding 2,000 l, an operating temperature not exceeding 95 °C, and an operating pressure not exceeding 1,0 MPa (10 bar).
This document covers metallic and plastic made buffer tanks.
Although this document does not consider any buffer tanks mainly intended for direct firing, it allows for the provision of electric heating elements for auxiliary purposes.
NOTE The energy assessment is performed by EN 15332 or EN 12897.
- Standard22 pagesEnglish languagesale 10% offe-Library read for1 day
EN 13611:2019, Clause 1 is applicable with the following modification and addition:
Modification:
The 1st paragraph of EN 13611:2019, Clause 1 is replaced by:
This document specifies the safety, design, construction, and performance requirements and testing for multifunctional controls for burners and appliances burning one or more gaseous fuels, hereafter referred to as ‘MFC’. This document is applicable to MFCs with declared maximum inlet pressures up to and including 50 kPa and nominal connection sizes up to and including DN 150.
Addition:
This document is applicable to MFCs consisting of two or more functions, at least one of which is a mechanical control, as specified in the relevant control standard (see Figure 1).
This document does not apply to MFCs consisting only of electronics (an example is a combination of functions according to EN 298:2022 and EN 1643:2022).
The 4th paragraph of EN 13611:2019, Clause 1 is removed.
- Standard30 pagesEnglish languagesale 10% offe-Library read for1 day
EN 13611:2019, Clause 1 applies with the following modification and addition:
Modification:
The 1st paragraph of EN 13611:2019, Clause 1 is replaced by:
This document specifies the safety, design, construction, and performance requirements and testing for automatic shut-off valves for burners and appliances burning one or more gaseous fuels, hereafter referred to as “valves”.
This document is applicable to valves with declared maximum inlet pressures up to and including 500 kPa and of nominal connection sizes up to and including DN 250.
Addition:
This document is applicable to:
- electrically actuated valves;
- valves actuated by fluids where the control valves for these fluids are actuated electrically, but not to any external electrical devices for switching the control signal or actuating energy;
- valves where the flow rate is controlled by external electrical signals, either in discrete steps or proportional to the applied signal;
- valves fitted with closed position indicator switches.
An assessment method for valve designs is given by this document.
The 4th paragraph of EN 13611:2019, Clause 1 is removed.
- Standard66 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies safety, constructional, performance and testing requirements of normally open automatic vent valves, hereafter referred to as “valves”. This document applies to valves with a declared maximum operating pressure up to and including 500 kPa of nominal connection sizes up to and including DN 100 (4”), for use in gas control train of gas burners or in appliances using gaseous fuels such as natural, manufactured or liquefied petroleum gas (LPG). It is not applicable to corrosive and waste gases. This document applies to: — electrically operated valves and to valves actuated by fluids where the control valves for these fluids are actuated electrically, but not to any external devices for switching the control signal or actuating energy; — valves fitted with open position indicator switches. This document covers type testing only.
- Standard26 pagesEnglish languagesale 15% off
This document specifies, the requirements and test methods concerning the classification and marking of gas-fired central heating boilers that are fitted with atmospheric burners, fan assisted atmospheric burners and are hereafter referred to as “boilers”.
Where the word boiler is used, this is intended to be read as the boiler including its connecting ducts, ducts and terminals, if any.
This document covers gas-fired central heating boilers type B11, B11BS, B12, B12BS, B13, B13BS:
NOTE 1 For further background information on appliance types see EN 1749:2020.
a) that have a nominal heat input (on the basis of net calorific value) not exceeding 70 kW;
b) that use one or more combustible gases of the three gas families at the pressures stated in EN 437:2021;
c) where the temperature of the heat transfer fluid does not exceed 105 °C during normal operation;
d) where the maximum operating pressure in the water circuit does not exceed 6 bar;
e) which are declared in the technical instructions to be either a “low temperature boiler” or a “standard boiler”. If no declaration is given the boiler is to be considered a “standard boiler”;
f) which are intended to be installed inside a building or in a partially protected place;
g) which are intended to produce also hot water either by the instantaneous or storage principle, as a single unit;
h) which are designed for either sealed water systems or for open water systems.
NOTE 2 This document provides requirements for boilers with known constructions. For boilers with any alternative constructions, which might not fully be covered by this document, the risk associated with this alternative construction needs to be assessed.
An example of an assessment methodology, based upon risk assessment, is given in Clause 11.
This document does not cover all the requirements for:
aa) appliances that are intended to be connected to gas grids where the quality of the distributed gas is likely to vary to a large extent over the lifetime of the appliance (see Annex AB);
ab) appliances using flue dampers;
ac) appliances that have a nominal heat input (on the basis of net calorific value) exceeding 70 kW;
ad) appliances of the types A, B14, B¬2, B3, B4, B5 and C;
ae) appliances intended to be connected to a (common) flue having mechanical extraction;
af) appliances with gas/air ratio control;
ag) modular boilers;
ah) boilers which can give rise to condensation under certain circumstances;
ai) boilers intended to be installed in a room with a foreseeable negative pressure relative to the pressure in the flue system;
aj) surface temperatures of external parts particular to children and elderly people;
ak) appliances that are intended to burn natural gases of the second family where hydrogen is added to the natural gas;
al) boilers intended to be installed in areas accessible to elderly people and children;
am) boilers equipped with an adaptive combustion control function (ACCF).
NOTE Negative pressure relative to the pressure in the flue system can for example be caused by mechanical or thermal ventilation in airtight buildings.
- Standard55 pagesEnglish languagesale 10% offe-Library read for1 day
- Corrigendum2 pagesEnglish languagesale 10% offe-Library read for1 day
EN 13611:2019, Clause 1 applies with the following modification and addition:
Modification:
The 1st paragraph of EN 13611:2019, Clause 1 is replaced by:
This document specifies the safety, design, construction, and performance requirements and testing for
thermoelectric flame supervision devices, energized by a thermocouple intended for use with burners
and appliances burning one or more gaseous fuels, hereafter referred to as “controls”.
This document is applicable to controls with declared maximum inlet pressures up to and including
500 kPa and of nominal connection sizes up to and including DN 50.
Addition:
This document is not applicable to:
— the thermocouple;
— controls which use auxiliary energy (e.g. electrical energy supplied externally).
The 4th paragraph of EN 13611:2019, Clause 1 is removed.
- Standard40 pagesEnglish languagesale 10% offe-Library read for1 day
This document gives guidance on hydrogen specific safety, design, construction, and performance requirements and testing of safety, control or regulating devices (hereafter referred to as controls) for burners and appliances burning gases with hydrogen content.
The following hydrogen concentrations are covered in this document:
- H2NG (hydrogen in natural gas) blends of 20 % hydrogen; or
- 100 % hydrogen; or
- varying blends / admixtures to natural gas.
Furthermore, it identifies the expected revision needs of the existing CEN/TC 58 standards as well as the need of potential further new standardization deliverables.
- Technical report87 pagesEnglish languagesale 10% offe-Library read for1 day
EN 13611:2019, Clause 1 applies with the following modification and addition:
Modification:
The 1st paragraph of EN 13611:2019, Clause 1 is replaced by:
This document specifies the safety, design, construction, and performance requirements and testing for
automatic vent valves for burners and appliances burning one or more gaseous fuels, hereafter referred
to as “valves”.
This document is applicable to valves with declared maximum inlet pressures up to and including
500 kPa and of nominal connection sizes up to and including DN 100.
Addition:
This document is applicable to:
— electrically actuated valves;
— valves actuated by fluids where the control valves for these fluids are actuated electrically, but not to
any external electrical devices for switching the control signal or actuating energy;
— valves fitted with open position indicator switches.
The 4th paragraph of EN 13611:2019, Clause 1 is removed.
- Standard43 pagesEnglish languagesale 10% offe-Library read for1 day
EN 13611:2019, Clause 1 applies with the following modification and addition:
Modification:
The 1st paragraph of EN 13611:2019, Clause 1 is replaced by:
This document specifies the safety, design, construction, and performance requirements and testing for
electronic pressure and/or flow rate regulators for burners and appliances burning one or more gaseous
fuels, hereafter referred to as “regulators”.
This document is applicable to regulators with declared maximum inlet pressures up to and including
500 kPa and of nominal connection sizes up to and including DN 250.
Addition:
This document is applicable to:
— regulators which use auxiliary energy;
— regulators, which function by controlling a gas outlet pressure or a gas flow rate;
— regulators with a modular structure specified as a unit;
— regulators intended for gas appliances to be installed indoor or in the open air and exposed to the
environment.
This document is not applicable to:
— regulators connected directly to a gas distribution network or to a container that maintains a
standard distribution pressure.
The 4th paragraph of EN 13611:2019, Clause 1 is removed.
- Standard50 pagesEnglish languagesale 10% offe-Library read for1 day
EN 13611:2019, Clause 1 applies with the following modification and addition:
Modification:
The 1st paragraph of EN 13611:2019, Clause 1 is replaced by:
This document specifies the safety, design, construction, and performance requirements and testing for
pneumatic pressure regulators and safety devices for burners and appliances burning one or more
gaseous fuels, hereafter referred to as “pressure regulators”.
This document is applicable to pressure regulators with declared maximum inlet pressures above 50 kPa
up to and including 500 kPa and of nominal connection sizes up to and including DN 250.
Addition:
This document is applicable to:
— pressure regulators incorporating safety devices;
— pressure regulators and safety devices which use auxiliary energy;
— stand-alone pressure regulators or pressure regulators equipped with a control device for maximum
or minimum gas pressure.
This document is not applicable to:
— pressure regulators connected directly to a gas distribution network or to a container that maintains
a standard distribution pressure;
— pressure regulators intended for gas appliances to be installed in the open air and exposed to the
environment.
The 4th paragraph of EN 13611:2019, Clause 1 is removed.
- Standard63 pagesEnglish languagesale 10% offe-Library read for1 day
Scope of CEN/TS 15502-3-1
EN 15502-2-1:2022, Clause 1 applies with the following modifications:
Add after k):
l) which are fully premixed appliances equipped with an Adaptive Combustion Control Function (ACCF) that are intended to be connected to gas grids where the quality of the distributed gas is likely to vary to a large extent over the lifetime of the appliance including gas grids for natural gases of the second family where up to 20% hydrogen volume is added to the natural gas (H2NG-Y20).
m) which are fully premixed appliances equipped with a Pneumatic Gas Air Ratio controller (PGAR) that are intended to be connected to gas grids for natural gases of the second family where up to 20% hydrogen volume is added to the natural gas (H2NG-Y20), where the quality of the distributed gas without adding the hydrogen is not likely to vary to a large extent over the lifetime of the appliance.
Replace ab) and ak) and al) by the following:
ab) appliances that are intended to be connected to gas grids where the quality of the distributed gas is likely to vary to a large extent over the lifetime of the appliance (see Annex AB of EN 15502-1:2021), except for fully premixed appliances with a ACCF, as ACCF appliances are designed to adapt to variations in gas quality.
ak) appliances that are intended to burn natural gases of the second family where hydrogen is added to the natural gas, except for fully premixed appliances with a ACCF or PGAR (which are covered by this document);
al) Partially premixed appliances equipped with an adaptive combustion control function (ACCF).
- Technical specification59 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies the minimum requirements for safety related equipment for shell boilers (generator and/or assemblies) as specified in EN 12953-1:2012, to ensure the boiler operates within the allowable limits (pressure, temperature, etc.) and if the limits are exceeded the energy supply is automatically interrupted and locked out, irrespective of the degree of intervention.
NOTE 1 For this document, the term “boiler” is applicable for generator and/or assemblies.
NOTE 2 The maximum time of operation without manual (human) intervention can be specified for each boiler system.
NOTE 3 Annex C gives recommendations of operation and testing of the boiler system with a maximum time of operation without manual (human) intervention of 24 h and 72 h.
- Standard72 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies requirements for limiters which are incorporated into safety systems for shell boilers as specified in EN 12953 1:2012.
The design requirements and examination of the limiters are covered in this document.
NOTE See Annex E for determination of the characteristic data for use in protective circuits with a safety integrity level (SIL) rating. The requirements for limiters with regard to the safety integrity level (SIL), for example, in accordance with EN 61508 are not covered in this document.
- Standard50 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies requirements and guidance for manufacturers of ammonia-fired boilers regarding functional tests performed at the time of design and on-site acceptance tests, in order to meet the required environmental performance. This document stipulates the test methods, the measurement items, the evaluation methods and the test reports for each test. This document is applicable to: a) land boilers used for power generation with an electrical output of 100 MWe or more; b) equipment that uses NH3 of any mixing ratio as fuel; c) boilers with burners for combustion of fuel. This document does not apply to heat recovery steam generators for gas turbines, fluidized bed boiler, stokers, black liquor recovery boiler and process heat transfer equipment (used in petroleum refining).
- Technical specification20 pagesEnglish languagesale 15% off
- Corrigendum2 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies the minimum requirements for safety related equipment for shell boilers (generator and/or assemblies) as specified in EN 12953-1:2012, to ensure the boiler operates within the allowable limits (pressure, temperature, etc.) and if the limits are exceeded the energy supply is automatically interrupted and locked out, irrespective of the degree of intervention.
NOTE 1 For this document, the term “boiler” is applicable for generator and/or assemblies.
NOTE 2 The maximum time of operation without manual (human) intervention can be specified for each boiler system.
NOTE 3 Annex C gives recommendations of operation and testing of the boiler system with a maximum time of operation without manual (human) intervention of 24 h and 72 h.
- Standard72 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies requirements for limiters which are incorporated into safety systems for shell boilers as specified in EN 12953 1:2012.
The design requirements and examination of the limiters are covered in this document.
NOTE See Annex E for determination of the characteristic data for use in protective circuits with a safety integrity level (SIL) rating. The requirements for limiters with regard to the safety integrity level (SIL), for example, in accordance with EN 61508 are not covered in this document.
- Standard50 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies safety, constructional and performance requirements and testing of automatic, semi-automatic shut-off valves, and general purpose valves for gas burners, gas appliances and appliances of similar use excluding use in fuel gas infrastructures (transportation and distribution systems). This document applies to controls for use at maximum operating pressures above 500 kPa up to and including 6 300 kPa with sizes up to DN 250 for use on burners or in appliances using fuel gases, such as natural gas, manufactured gas or liquefied petroleum gas (LPG). This document applies to: — valves being mounted in gas installations; — valves directly or indirectly actuated, electrically or by mechanical means; — valves actuated by hydraulic or pneumatic means, including the pilot valves for these fluids if actuated electrically and including release valves, but not to any external electrical devices for switching the actuating energy; — valves where the flow rate is controlled by external electrical signals, either in discrete steps or proportional to the applied signal and valves fitted with closed position indicator switches; — valves to be used in appliances, but not in gas transfer systems outside appliances. This document covers type testing only. This document does not apply to valves covered under the scope of ISO 23551-1 or the ISO 23555 series.
- Standard39 pagesEnglish languagesale 15% off
This document specifies safety, constructional and performance requirements and testing of automatic, semi-automatic shut-off valves and general purpose valves for gas burners, gas appliances and appliances of similar use, hereinafter referred to as valves. This document applies to normally closed valves and general purpose valves mounted upstream to gas burners and gas appliances with declared maximum operating pressures up to and including 500 kPa, for use on burners or in appliances using fuel gases such as natural gas, manufactured gas or liquefied petroleum gas (LPG). It is not applicable to corrosive and waste gases. This document applies to: — valves directly or indirectly actuated, electrically or by mechanical means; — valves actuated by hydraulic or pneumatic means; — valves where the flow rate is controlled by external electrical signals, either in discrete steps or proportional to the applied signal; and — valves fitted with closed position indicator switches. This document covers type testing only.
- Standard35 pagesEnglish languagesale 15% off
This document applies to the application design and installation of electrical equipment, control circuits and safety-related systems for furnaces which are operated with solid, liquid or gaseous fuels and their ancillary equipment. It specifies requirements to meet the operating conditions of furnaces, to reduce the hazards of combustion and to protect the heated systems from damage e.g. by overheating.
Such furnaces and the electrical equipment can be part by way of example of the following plant:
a) water heating systems;
b) steam boiler installations (steam and hot-water boilers) and heat recovery steam boilers;
NOTE 1 The requirements of this document apply according to the electrical equipment of electrically heated steam boilers.
NOTE 2 Seagoing vessels and offshore facilities are governed by International Maritime Law and as such are not within the scope of this document. These requirements can be used for such facilities.
c) warm air heaters;
d) hot-gas heaters;
e) heat exchanger systems;
f) combustion chambers of stationary turbines;
g) as long as no other standard is applicable for combined heat and power stations, we recommend the use of the requirements of this document;
This document can also be used as reference for electrical equipment requirements for thermo-processing equipment.
The requirements in this document are not applicable to electrical equipment for:
1) non-electrically heated appliances and burner control systems for household and similar purposes;
2) furnaces using technologies for the direct conversion of heat into electrical energy;
3) combustion chambers of non-stationary prime movers and turbines;
4) central oil supply systems for individual heating appliances;
5) furnaces using solid fuels for heating purposes for household use with a nominal thermal output up to 1 MW;
6) furnaces which are used to heat process fluids and gasses in chemical plant.
This document can be used as a basis for the requirements placed on electrical equipment for furnaces, which are excluded from its field of application.
This document specifies special requirements for the management of functional safety.
- Standard96 pagesEnglish languagesale 10% offe-Library read for1 day
This Part of this European Standard specifies requirements for the design and calculation of pressure parts of shell boilers as defined in EN 12953 1.
NOTE For other components such as economisers, superheaters, tube walls, headers, reference should be made to EN 12952 series.
- Corrigendum2 pagesEnglish languagesale 10% offe-Library read for1 day
EN 13611:2019, Clause 1 applies with the following modification and addition:
Modification:
The 1st paragraph of EN 13611:2019, Clause 1 is replaced by:
This document specifies the safety, design, construction, and performance requirements and testing for
thermoelectric flame supervision devices, energized by a thermocouple intended for use with burners
and appliances burning one or more gaseous fuels, hereafter referred to as “controls”.
This document is applicable to controls with declared maximum inlet pressures up to and including
500 kPa and of nominal connection sizes up to and including DN 50.
Addition:
This document is not applicable to:
— the thermocouple;
— controls which use auxiliary energy (e.g. electrical energy supplied externally).
The 4th paragraph of EN 13611:2019, Clause 1 is removed.
- Standard40 pagesEnglish languagesale 10% offe-Library read for1 day
This document applies to the application design and installation of electrical equipment, control circuits and safety-related systems for furnaces which are operated with solid, liquid or gaseous fuels and their ancillary equipment. It specifies requirements to meet the operating conditions of furnaces, to reduce the hazards of combustion and to protect the heated systems from damage e.g. by overheating. Such furnaces and the electrical equipment can be part by way of example of the following plant: a) water heating systems; b) steam boiler installations (steam and hot-water boilers) and heat recovery steam boilers; NOTE 1 The requirements of this document apply according to the electrical equipment of electrically heated steam boilers. NOTE 2 Seagoing vessels and offshore facilities are governed by International Maritime Law and as such are not within the scope of this document. These requirements can be used for such facilities. c) warm air heaters; d) hot-gas heaters; e) heat exchanger systems; f) combustion chambers of stationary turbines; g) as long as no other standard is applicable for combined heat and power stations, we recommend the use of the requirements of this document; This document can also be used as reference for electrical equipment requirements for thermo-processing equipment. The requirements in this document are not applicable to electrical equipment for: 1) non-electrically heated appliances and burner control systems for household and similar purposes; 2) furnaces using technologies for the direct conversion of heat into electrical energy; 3) combustion chambers of non-stationary prime movers and turbines; 4) central oil supply systems for individual heating appliances; 5) furnaces using solid fuels for heating purposes for household use with a nominal thermal output up to 1 MW; 6) furnaces which are used to heat process fluids and gasses in chemical plant. This document can be used as a basis for the requirements placed on electrical equipment for furnaces, which are excluded from its field of application. This document specifies special requirements for the management of functional safety.
- Standard96 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the common requirements and test methods, as well as the classification, marking and energy labelling of gas-fired central heating boilers that are fitted with atmospheric burners, fan assisted atmospheric burners or fully premixed burners, and are hereafter referred to as “boilers”.
This European Standard is to be used in conjunction with the specific Parts 2 (Part 2-1 and following ones).
This European Standard applies to boilers of types B and C.
NOTE For further background information on appliance types see CEN/TR 1749:2014 [1].
a) that use one or more combustible gases of the three gas families at the pressures stated in EN 437;
b) where the temperature of the water is below or above 105 °C during normal operation;
c) where the maximum operating pressure in the water circuit does not exceed 6 bar;
d) which can give rise to condensation under certain circumstances;
e) which are declared in the instructions for installation to be either a "condensing" boiler or a "low temperature boiler" or a "standard boiler" or an "other boiler". If no declaration is given the boiler is to be considered both a "standard boiler" and an "other boiler";
NOTE The Ecodesign Directive defines "other boilers", "low temperature boilers" and "condensing boilers". The Boiler Efficiency Directive defines "standard boilers", "low temperature boilers" and "condensing boilers". Depending on the legislation applied, a boiler can be both "a standard boiler" and an "other boiler"."
f) which are intended to be installed inside a building or in a partially protected place;
g) which are intended to produce also hot water either by the instantaneous or storage principle as a single unit.
This European Standard applies to boilers designed for sealed water systems or for open water systems.
NOTE This general standard and the specific standards (see Part 2) provide requirements for boilers with known constructions. For boilers with any alternative constructions, which might not fully be covered by this standard or a specific standard, the risk associated with this alternative construction will need to be assessed.
An example of an assessment methodology, based upon risk assessment, is given in Clause 11.
This European Standard is not intended to cover appliances intended for connection to gas grids where the quality of the distributed gas is likely to vary to a large extent over the lifetime of the appliance (see Annex EE).
This European Standard is not intended to cover appliances designed and constructed to burn gas containing toxic components.
- Standard213 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies the requirements and test methods, as well as the classification and marking of gas-fired central heating boilers that are fitted with atmospheric burners, fan assisted atmospheric burners or fully premixed burners, and are hereafter referred to as "boilers".
This document is intended to be used in conjunction with EN 15502-1:2021.
This document covers gas-fired central heating boilers from the types C1 up to C(11) and the types B2, B3 and B5:
NOTE 1 For further background information on appliance types see EN 1749:2020.
a) that have a nominal heat input (on the basis of net calorific value) not exceeding 1 000 kW;
b) that use one or more combustible gases of the three gas families at the pressures stated in EN 437:2021;
c) where the temperature of the heat transfer fluid does not exceed 105 °C during normal operation;
d) where the maximum operating pressure in the water circuit does not exceed 6 bar;
e) which can give rise to condensation under certain circumstances;
f) which are declared in the instructions for installation to be either a "condensing" boiler or a "low temperature boiler" or a "standard boiler"; if no declaration is given the boiler is to be considered a "standard boiler";
g) which are intended to be installed inside a building or in a partially protected place;
h) which are intended to produce also hot water either by the instantaneous or storage principle as a single unit;
i) which are designed for either sealed water systems or for open water systems;
j) which are either modular boilers, or non-modular boilers.
k) which are from the types C(10) that are equipped with a gas-air ratio control and that have a ∆pmax, saf(min) of 25 Pa, and C(11) that have condensing boiler modules that are equipped with a gas-air ratio control and that have a ∆pmax, saf(min) of 25 Pa.
NOTE 2 This document provides requirements for boilers with known constructions. For boilers with any alternative constructions, which might not fully be covered by this standard, the risk associated with this alternative construction needs to be assessed.
An example of an assessment methodology, based upon risk assessment, is given in Clause 11.
This document does not cover all the requirements for:
aa) appliances above 1 000 kW;
ab) appliances that are intended to be connected to gas grids where the quality of the distributed gas is likely to vary to a large extent over the lifetime of the appliance (see Annex AB of EN 15502-1:2021);
ac) appliances using flue dampers;
ad) appliances of the types B21, B31, B51, C21, C41, C51, C61, C71, C81, C(12) and C(13);
ae) C7 appliances that have a nominal heat input (on the basis of net calorific value) exceeding 70 kW;
af) appliances incorporating flexible plastic flue liners;
ag) C(10) boilers:
1) without a gas-air ratio control, or
2) which are non-condensing appliances, or
3) which have a maximum safety pressure difference at minimum heat input not equal to 25 Pa (∆pmax, saf(min));
ah) C(11) boilers that have boiler modules:
1) without a gas-air ratio control, or
2) which are non-condensing appliances, or
3) which have a maximum safety pressure difference at minimum heat input not equal to 25 Pa (∆pmax, saf(min));
ai) appliances intended to be connected to a flue having mechanical extraction;
aj) surface temperatures of external parts particular to children and elderly people;
ak) appliances that are intended to burn natural gases of the second family where hydrogen is added to the natural gas;
al) appliances equipped with an adaptive combustion control function (ACCF);
am) boilers intended to be installed in areas accessible to elderly people and children.
- Standard105 pagesEnglish languagesale 10% offe-Library read for1 day
EN 13611:2019, Clause 1 applies with the following modification and addition:
Modification:
The 1st paragraph of EN 13611:2019, Clause 1 is replaced by:
This document specifies the safety, design, construction, and performance requirements and testing for
pressure regulators and pneumatic gas/air ratio pressure regulators (zero pressure regulators are
included as a special type of pneumatic gas/air ratio pressure regulators) for burners and appliances
burning one or more gaseous fuels, hereafter referred to as “pressure regulators”.
This document is applicable to pressure regulators with declared maximum inlet pressures up to and
including 50 kPa and of nominal connection sizes up to and including DN 250.
Addition:
This document is applicable to:
— pressure regulators which use auxiliary energy;
— pneumatic gas/air ratio pressure regulators, which function by controlling a gas outlet pressure in
response to an air signal pressure, air signal differential pressure, and/or to a furnace pressure signal
(zero pressure regulators are included as a special type of pneumatic gas/air ratio pressure
regulators);
— pneumatic gas/air ratio pressure regulators, which change an air outlet pressure in response to a gas
signal pressure or a gas signal differential pressure.
This document is not applicable to:
— pressure regulators connected directly to a gas distribution network or to a container that maintains
a standard distribution pressure;
— pressure regulators intended for gas appliances to be installed in the open air and exposed to the
environment;
— mechanically linked gas/air ratio controls;
— electronic gas/air ratio controls (EN 12067-2:2022).
The 4th paragraph of EN 13611:2019, Clause 1 is removed.
- Standard60 pagesEnglish languagesale 10% offe-Library read for1 day
EN 13611:2019, Clause 1 applies with the following modification and addition:
Modification:
The 1st paragraph of EN 13611:2019, Clause 1 is replaced by:
This document specifies the safety, design, construction, and performance requirements and testing for gas filters for burners and appliances burning one or more gaseous fuels.
This document is applicable to gas filters with declared maximum inlet pressures up to and including 600 kPa and of nominal connection sizes up to and including DN 250.
Addition:
This document is not applicable to:
- gas filters that are connected directly to mains pipe-work or to a container that maintains a standard distribution pressure.
The 4th paragraph of EN 13611:2019, Clause 1 is removed.
- Standard36 pagesEnglish languagesale 10% offe-Library read for1 day
EN 13611:2019, Clause 1 applies with the following modification and addition:
Modification:
The 1st paragraph of EN 13611:2019, Clause 1 is replaced by:
This document specifies the safety, design, construction, and performance requirements and testing for
mechanical thermostats intended for use with gas appliances and similar use, hereafter referred to as
“thermostats”.
This document is applicable to thermostats with declared maximum inlet pressures up to and including
50 kPa and of nominal connection sizes up to and including DN 50 for use with one or more fuel gases.
Addition:
This document is applicable to thermostats controlling the gas flow directly or indirectly through an
integral gas valve. This document applies to thermostats used with gas appliances which are not installed
in the open air.
Thermostats dealt with in this document are intended for control functions.
This document is not applicable to:
a) controls which use auxiliary energy (e.g. electrical energy supplied externally);
b) an assessment of the control regarding Performance Level (PL) and Safety Integrity Level (SIL).
The 4th paragraph of EN 13611:2019, Clause 1 is removed.
- Standard43 pagesEnglish languagesale 10% offe-Library read for1 day
This document covers the measurements of the emissions of carbon monoxide (CO) and nitrogen oxides (NOX) produced by the combustion of gaseous fuel in domestic appliances. It is also possible to adapt it to liquid fuel appliances.
It explains how to correct the measured values obtained at the testing conditions of temperature, humidity and gas used into the reference conditions, as well as their conversion to different aeration factor expressed as %O2 in the dry products of combustion.
The document also contains information on the types of sampling probes, mainly their form and their dimensions, which depend on the type of flue gas system.
It also gives detailed information on the sampling of the flue gas to be analysed, the transport / transfer lines and their components, and the materials recommended for their construction.
This document contains hints on the calculation of the uncertainties and the parameters to be considered in the whole analysis chain from the sampling probe to the analysers including the calibration gases.
The calculation of the uncertainties of the measurements of NOX and CO is not covered by this document.
- Technical report41 pagesEnglish languagesale 10% offe-Library read for1 day
EN 13611:2019, Clause 1 applies with the following modification and addition:
Modification:
The 1st paragraph of EN 13611:2019, Clause 1 is replaced by:
This document specifies the safety, design, construction, and performance requirements and testing for manually operated taps and presetting taps for burners and appliances burning one or more gaseous fuels, hereafter referred to as "taps".
This document is applicable to taps with declared maximum inlet pressures up to and including 50 kPa and of nominal connection sizes up to and including DN 50 for use with one or more fuel gases.
Addition:
This document is not applicable to:
a) manual operated shut-off valves conforming to EN 331:2015;
b) controls which use auxiliary energy (e.g. electrical energy supplied externally).
The 4th paragraph of EN 13611:2019, Clause 1 is removed.
- Standard42 pagesEnglish languagesale 10% offe-Library read for1 day
EN 13611:2019, Clause 1 applies with the following modification:
Modification:
The 1st paragraph of EN 13611:2019, Clause 1 is replaced by:
This document specifies the safety, design, construction, and performance requirements and testing of pressure sensing devices for burners and appliances burning one or more gaseous fuels.
This document is applicable to pressure sensing devices for gaseous fuels, air, or combustion products with declared maximum inlet pressures up to and including 500 kPa.
It applies to all types of pressure sensing devices, including electronic, differential and inferential types.
It also specifies requirements for pressure sensing devices which are intended to be applied to steam boilers and as such need to meet increased reliability requirements.
EN 13611:2019 Clause 1, 4th paragraph is not applicable.
- Standard60 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies, the requirements and test methods concerning the classification and marking of gas-fired central heating boilers that are fitted with atmospheric burners, fan assisted atmospheric burners and are hereafter referred to as “boilers”.
Where the word boiler is used, this is intended to be read as the boiler including its connecting ducts, ducts and terminals, if any.
This document covers gas-fired central heating boilers type B11, B11BS, B12, B12BS, B13, B13BS:
NOTE 1 For further background information on appliance types see EN 1749:2020.
a) that have a nominal heat input (on the basis of net calorific value) not exceeding 70 kW;
b) that use one or more combustible gases of the three gas families at the pressures stated in EN 437:2021;
c) where the temperature of the heat transfer fluid does not exceed 105 °C during normal operation;
d) where the maximum operating pressure in the water circuit does not exceed 6 bar;
e) which are declared in the technical instructions to be either a “low temperature boiler” or a “standard boiler”. If no declaration is given the boiler is to be considered a “standard boiler”;
f) which are intended to be installed inside a building or in a partially protected place;
g) which are intended to produce also hot water either by the instantaneous or storage principle, as a single unit;
h) which are designed for either sealed water systems or for open water systems.
NOTE 2 This document provides requirements for boilers with known constructions. For boilers with any alternative constructions, which might not fully be covered by this document, the risk associated with this alternative construction needs to be assessed.
An example of an assessment methodology, based upon risk assessment, is given in Clause 11.
This document does not cover all the requirements for:
aa) appliances that are intended to be connected to gas grids where the quality of the distributed gas is likely to vary to a large extent over the lifetime of the appliance (see Annex AB);
ab) appliances using flue dampers;
ac) appliances that have a nominal heat input (on the basis of net calorific value) exceeding 70 kW;
ad) appliances of the types A, B14, B¬2, B3, B4, B5 and C;
ae) appliances intended to be connected to a (common) flue having mechanical extraction;
af) appliances with gas/air ratio control;
ag) modular boilers;
ah) boilers which can give rise to condensation under certain circumstances;
ai) boilers intended to be installed in a room with a foreseeable negative pressure relative to the pressure in the flue system;
aj) surface temperatures of external parts particular to children and elderly people;
ak) appliances that are intended to burn natural gases of the second family where hydrogen is added to the natural gas;
al) boilers intended to be installed in areas accessible to elderly people and children;
am) boilers equipped with an adaptive combustion control function (ACCF).
NOTE Negative pressure relative to the pressure in the flue system can for example be caused by mechanical or thermal ventilation in airtight buildings.
- Standard55 pagesEnglish languagesale 10% offe-Library read for1 day
This Part of this European Standard specifies requirements for the design and calculation of pressure parts of shell boilers as defined in EN 12953 1.
NOTE For other components such as economisers, superheaters, tube walls, headers, reference should be made to EN 12952 series.
- Corrigendum2 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies the minimum requirements for rubber hoses and hose assemblies for use in oil burners.
The following two types of hose assembly are specified:
— Type 1: Hose assemblies for flux and reflux, but not for insertion between the oil burner pump and the atomizing connection; maximum working pressure 1,0 MPa (10 bar); maximum oil temperature 100 °C;
— Type 2: Hose assemblies for insertion between the oil burner pump and the atomizing connection; maximum working pressure 4,0 MPa (40 bar); maximum oil temperature 100 °C.
The hose assemblies specified in this document are not intended to be used, without special assessment, for purposes other than oil burner installations.
- Standard21 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies the minimum requirements for rubber hoses and hose assemblies for use in oil burners.
The following two types of hose assembly are specified:
— Type 1: Hose assemblies for flux and reflux, but not for insertion between the oil burner pump and the atomizing connection; maximum working pressure 1,0 MPa (10 bar); maximum oil temperature 100 °C;
— Type 2: Hose assemblies for insertion between the oil burner pump and the atomizing connection; maximum working pressure 4,0 MPa (40 bar); maximum oil temperature 100 °C.
The hose assemblies specified in this document are not intended to be used, without special assessment, for purposes other than oil burner installations.
- Standard21 pagesEnglish languagesale 10% offe-Library read for1 day
Scope of CEN/TS 15502-3-1
EN 15502-2-1:2022, Clause 1 applies with the following modifications:
Add after k):
l) which are fully premixed appliances equipped with an Adaptive Combustion Control Function (ACCF) that are intended to be connected to gas grids where the quality of the distributed gas is likely to vary to a large extent over the lifetime of the appliance including gas grids for natural gases of the second family where up to 20% hydrogen volume is added to the natural gas (H2NG-Y20).
m) which are fully premixed appliances equipped with a Pneumatic Gas Air Ratio controller (PGAR) that are intended to be connected to gas grids for natural gases of the second family where up to 20% hydrogen volume is added to the natural gas (H2NG-Y20), where the quality of the distributed gas without adding the hydrogen is not likely to vary to a large extent over the lifetime of the appliance.
Replace ab) and ak) and al) by the following:
ab) appliances that are intended to be connected to gas grids where the quality of the distributed gas is likely to vary to a large extent over the lifetime of the appliance (see Annex AB of EN 15502-1:2021), except for fully premixed appliances with a ACCF, as ACCF appliances are designed to adapt to variations in gas quality.
ak) appliances that are intended to burn natural gases of the second family where hydrogen is added to the natural gas, except for fully premixed appliances with a ACCF or PGAR (which are covered by this document);
al) Partially premixed appliances equipped with an adaptive combustion control function (ACCF).
- Technical specification59 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies the minimum requirements for rubber hoses and hose assemblies for use in oil burners. The following two types of hose assembly are specified: — Type 1: Hose assemblies for flux and reflux, but not for insertion between the oil burner pump and the atomizing connection; maximum working pressure 1,0 MPa (10 bar); maximum oil temperature 100 °C; — Type 2: Hose assemblies for insertion between the oil burner pump and the atomizing connection; maximum working pressure 4,0 MPa (40 bar); maximum oil temperature 100 °C. The hose assemblies specified in this document are not intended to be used, without special assessment, for purposes other than oil burner installations.
- Standard14 pagesEnglish languagesale 15% off
- Standard14 pagesFrench languagesale 15% off
This document specifies the requirements and tests methods concerning the construction, safety, fitness for purpose, and rational use of energy, as well as the classification and marking of hybrid units.
A hybrid unit is composed of:
- a gas boiler as a heat generator which is able to supply the heat demand in all operating conditions;
- an electrical air-to-water heat pump, as a heat generator, which does not have to meet the heat demand in all operating conditions;
- a control unit (see definition 3.1.10).
A hybrid unit can include the facility to produce hot water, either by the instantaneous or storage principle, the whole being marketed as a single unit.
A gas boiler as part of a hybrid unit covered by this document is a gas-fired central heating boiler from the types C1 up to C9 and the types B2, B3 and B5, according to the classification in EN 1749:2020:
a) that have a nominal heat input (on the basis of gross calorific value) not exceeding 400 kW;
b) that use one or more combustible gases of the three gas families at the pressures stated in EN 437:2021;
c) where the temperature of the heat transfer fluid does not exceed 105 °C during normal operation;
d) where the maximum operating pressure in the water circuit does not exceed 6 bar;
e) which are classified as a gas-fired central heating boiler;
f) which are intended to be installed either indoors or outdoors in a partially protected place;
g) which are designed for either sealed water systems or for open water systems.
This document provides requirements for boilers with known constructions.
NOTE 1 For boilers with any alternative constructions, which might not fully be covered by this document, the risk associated with this alternative construction needs to be assessed.
NOTE 2 An example of an assessment methodology, based upon risk assessment and which covers the essential requirements of the Gas Appliance Regulation UE/426/2016, is given in Clause 11.
This document does not cover all the requirements for:
aa) appliances that are intended to be connected to gas grids where the quality of the distributed gas is likely to vary to a large extent over the lifetime of the appliance (see EN 15502-1:2021, Annex AB);
ab) appliances using flue dampers;
ac) appliances of the types B21, B31, B51, C21, C41, C51, C61, C71 and C81;
ad) appliances incorporating flexible plastic flue liners;
ae) appliances designed to become connected to a combined flue duct system.
af) appliances of the types C(10),C(11), C(12) and C(13);
ag) C7 appliances that have a nominal heat input (on the basis of net calorific value) exceeding 70 kW;
ah) appliances intended to be connected to a flue having mechanical extraction;
ai) surface temperatures of external parts particular to children and elderly people;
aj) appliances that are intended to burn natural gases of the second family where hydrogen is added to the natural gas;
ak) appliances equipped with an adaptive combustion control function (ACCF);
al) boilers intended to be installed in areas accessible to elderly people and children.
This document specifies minimum operating requirements which ensure that the products are fit for the use designated by the technical instructions when used for space heating and/or DHW production.
This document is intended to be used in conjunction with:
ba) the gas-fired boiler, the generic part EN 15502-1:2021 and specific parts FprEN 15502-2-1:2022 and FprEN 15502-2-2:2022;
bb) the electrical heat pump, EN 14511-4:2018, EN 378-1:2016+A1:2020, EN 378-2:2016 and EN 14825:2022;
bc) electrical safety, EN 60335-1:2012 , EN 60335-2-102:2016 and IEC 60335-2-40:2018;
bd) for domestic hot water production, EN 13203-5:2022.
- Standard42 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the common requirements and test methods, as well as the classification, marking and energy labelling of gas-fired central heating boilers that are fitted with atmospheric burners, fan assisted atmospheric burners or fully premixed burners, and are hereafter referred to as “boilers”.
This European Standard is to be used in conjunction with the specific Parts 2 (Part 2-1 and following ones).
This European Standard applies to boilers of types B and C.
NOTE For further background information on appliance types see CEN/TR 1749:2014 [1].
a) that use one or more combustible gases of the three gas families at the pressures stated in EN 437;
b) where the temperature of the water is below or above 105 °C during normal operation;
c) where the maximum operating pressure in the water circuit does not exceed 6 bar;
d) which can give rise to condensation under certain circumstances;
e) which are declared in the instructions for installation to be either a "condensing" boiler or a "low temperature boiler" or a "standard boiler" or an "other boiler". If no declaration is given the boiler is to be considered both a "standard boiler" and an "other boiler";
NOTE The Ecodesign Directive defines "other boilers", "low temperature boilers" and "condensing boilers". The Boiler Efficiency Directive defines "standard boilers", "low temperature boilers" and "condensing boilers". Depending on the legislation applied, a boiler can be both "a standard boiler" and an "other boiler"."
f) which are intended to be installed inside a building or in a partially protected place;
g) which are intended to produce also hot water either by the instantaneous or storage principle as a single unit.
This European Standard applies to boilers designed for sealed water systems or for open water systems.
NOTE This general standard and the specific standards (see Part 2) provide requirements for boilers with known constructions. For boilers with any alternative constructions, which might not fully be covered by this standard or a specific standard, the risk associated with this alternative construction will need to be assessed.
An example of an assessment methodology, based upon risk assessment, is given in Clause 11.
This European Standard is not intended to cover appliances intended for connection to gas grids where the quality of the distributed gas is likely to vary to a large extent over the lifetime of the appliance (see Annex EE).
This European Standard is not intended to cover appliances designed and constructed to burn gas containing toxic components.
- Standard213 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies the requirements and test methods, as well as the classification and marking of gas-fired central heating boilers that are fitted with atmospheric burners, fan assisted atmospheric burners or fully premixed burners, and are hereafter referred to as "boilers".
This document is intended to be used in conjunction with EN 15502-1:2021.
This document covers gas-fired central heating boilers from the types C1 up to C(11) and the types B2, B3 and B5:
NOTE 1 For further background information on appliance types see EN 1749:2020.
a) that have a nominal heat input (on the basis of net calorific value) not exceeding 1 000 kW;
b) that use one or more combustible gases of the three gas families at the pressures stated in EN 437:2021;
c) where the temperature of the heat transfer fluid does not exceed 105 °C during normal operation;
d) where the maximum operating pressure in the water circuit does not exceed 6 bar;
e) which can give rise to condensation under certain circumstances;
f) which are declared in the instructions for installation to be either a "condensing" boiler or a "low temperature boiler" or a "standard boiler"; if no declaration is given the boiler is to be considered a "standard boiler";
g) which are intended to be installed inside a building or in a partially protected place;
h) which are intended to produce also hot water either by the instantaneous or storage principle as a single unit;
i) which are designed for either sealed water systems or for open water systems;
j) which are either modular boilers, or non-modular boilers.
k) which are from the types C(10) that are equipped with a gas-air ratio control and that have a ∆pmax, saf(min) of 25 Pa, and C(11) that have condensing boiler modules that are equipped with a gas-air ratio control and that have a ∆pmax, saf(min) of 25 Pa.
NOTE 2 This document provides requirements for boilers with known constructions. For boilers with any alternative constructions, which might not fully be covered by this standard, the risk associated with this alternative construction needs to be assessed.
An example of an assessment methodology, based upon risk assessment, is given in Clause 11.
This document does not cover all the requirements for:
aa) appliances above 1 000 kW;
ab) appliances that are intended to be connected to gas grids where the quality of the distributed gas is likely to vary to a large extent over the lifetime of the appliance (see Annex AB of EN 15502-1:2021);
ac) appliances using flue dampers;
ad) appliances of the types B21, B31, B51, C21, C41, C51, C61, C71, C81, C(12) and C(13);
ae) C7 appliances that have a nominal heat input (on the basis of net calorific value) exceeding 70 kW;
af) appliances incorporating flexible plastic flue liners;
ag) C(10) boilers:
1) without a gas-air ratio control, or
2) which are non-condensing appliances, or
3) which have a maximum safety pressure difference at minimum heat input not equal to 25 Pa (∆pmax, saf(min));
ah) C(11) boilers that have boiler modules:
1) without a gas-air ratio control, or
2) which are non-condensing appliances, or
3) which have a maximum safety pressure difference at minimum heat input not equal to 25 Pa (∆pmax, saf(min));
ai) appliances intended to be connected to a flue having mechanical extraction;
aj) surface temperatures of external parts particular to children and elderly people;
ak) appliances that are intended to burn natural gases of the second family where hydrogen is added to the natural gas;
al) appliances equipped with an adaptive combustion control function (ACCF);
am) boilers intended to be installed in areas accessible to elderly people and children.
- Standard105 pagesEnglish languagesale 10% offe-Library read for1 day
EN 13611:2019, Clause 1 applies with the following modification and addition:
Modification:
The 1st paragraph of EN 13611:2019, Clause 1 is replaced by:
This document specifies the safety, design, construction, and performance requirements and testing for
mechanical thermostats intended for use with gas appliances and similar use, hereafter referred to as
“thermostats”.
This document is applicable to thermostats with declared maximum inlet pressures up to and including
50 kPa and of nominal connection sizes up to and including DN 50 for use with one or more fuel gases.
Addition:
This document is applicable to thermostats controlling the gas flow directly or indirectly through an
integral gas valve. This document applies to thermostats used with gas appliances which are not installed
in the open air.
Thermostats dealt with in this document are intended for control functions.
This document is not applicable to:
a) controls which use auxiliary energy (e.g. electrical energy supplied externally);
b) an assessment of the control regarding Performance Level (PL) and Safety Integrity Level (SIL).
The 4th paragraph of EN 13611:2019, Clause 1 is removed.
- Standard43 pagesEnglish languagesale 10% offe-Library read for1 day
EN 13611:2019, Clause 1 applies with the following modification and addition:
Modification:
The 1st paragraph of EN 13611:2019, Clause 1 is replaced by:
This document specifies the safety, design, construction, and performance requirements and testing for gas filters for burners and appliances burning one or more gaseous fuels.
This document is applicable to gas filters with declared maximum inlet pressures up to and including 600 kPa and of nominal connection sizes up to and including DN 250.
Addition:
This document is not applicable to:
- gas filters that are connected directly to mains pipe-work or to a container that maintains a standard distribution pressure.
The 4th paragraph of EN 13611:2019, Clause 1 is removed.
- Standard36 pagesEnglish languagesale 10% offe-Library read for1 day