This European Standard specifies the composition, property requirements including electrical properties, and tolerances on dimensions and form for copper profiles and profiled wire for electrical purposes, which would fit within a circumscribing circle of maximum 180 mm diameter.
The sampling procedures, the test methods for verification of conformity to the requirements of this standard, and the delivery conditions are also specified.

  • Standard
    28 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    29 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60172:2020  which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60172:2020 specifies, in accordance with the provisions of IEC 60216-1, a method for evaluating the temperature index of enamelled wire, varnished or unvarnished with an impregnating agent, and of tape wrapped round and rectangular wire, in air at atmospheric pressure by periodically monitoring changes in response to AC proof voltage tests. This procedure does not apply to fibre-insulated wire or wire covered with tapes containing inorganic fibres. NOTE The data obtained according to this test procedure provide the designer and development engineer with information for the selection of winding wire for further evaluation of insulation systems and equipment tests. This fifth edition cancels and replaces the fourth edition published in 2015. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- revision of 3.1, definition of thermal index;
- revision of 3.3, time to failure;
- revisions to 5.1.1 for clarity and to reduce the range wire size range to which the test applies;
- revisions to 5.1.2 for tape wrapped round and enamelled or tape wrapped rectangular wire for clarity;
- revision to Clause 9 to add the correlation coefficient, r to the report.

  • Standard
    28 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60317-42:1997 specifies the requirements of enamelled round copper winding wire of class 200 with a sole coating based on polyester-amide-imide resin, which may be modified providing it retains the chemical identity of the original resin and meets all specified wire requirements. A modified resin is a resin that has undergone a chemical change, or contains one or more additives to enhance certain performance or application characteristics. Class 200 is a thermal class that requires a minimum temperature index of 200 and a heat shock temperature of at least 220 °C. The temperature in degrees Celsius corresponding to the temperature index is not necessarily that at which it is recommended that the wire be operated and this will depend on many factors, including the type of equipment involved. The range of nominal conductor diameters covered by this part is:
– Grade 1: 0,018 mm up to and including 1,600 mm;
– Grade 2: 0,025 mm up to and including 5,000 mm.
The nominal conductor diameters are specified in clause 4 of IEC 60317-0-1.

  • Standard
    13 pages
    English and French language
    sale 15% off

This consolidated version consists of the first edition (1997) and its amendment 1 (2010). Therefore, no need to order amendment in addition to this publication.

  • Standard
    16 pages
    English and French language
    sale 15% off

This amendment 1 is valid for the following parts of the IEC 60317: Part 2 (1990), Part 3 (1990), Part 4 (1990), Part 10 (1972), Part 12 (1990), Part 14 (1990), Part 15 (1990), Part 16 (1990), Part 17 (1990), Part 18 (1990), Part 19 (1990), Part 20 (1990), Part 21 (1990), Part 22 (1990), Part 23 (1990), Part 24 (1990), Part 26 (1990), Part 28 (1990), Part 29 (1990), Part 30 (1990), Part 35 (1992), Part 36 (1992), Part 37 (1992) and Part 38 (1992).

  • Standard
    3 pages
    English and French language
    sale 15% off

IEC 60172:2020 is available as IEC 60172:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60172:2020 specifies, in accordance with the provisions of IEC 60216-1, a method for evaluating the temperature index of enamelled wire, varnished or unvarnished with an impregnating agent, and of tape wrapped round and rectangular wire, in air at atmospheric pressure by periodically monitoring changes in response to AC proof voltage tests. This procedure does not apply to fibre-insulated wire or wire covered with tapes containing inorganic fibres. NOTE The data obtained according to this test procedure provide the designer and development engineer with information for the selection of winding wire for further evaluation of insulation systems and equipment tests. This fifth edition cancels and replaces the fourth edition published in 2015. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- revision of 3.1, definition of thermal index;
- revision of 3.3, time to failure;
- revisions to 5.1.1 for clarity and to reduce the range wire size range to which the test applies;
- revisions to 5.1.2 for tape wrapped round and enamelled or tape wrapped rectangular wire for clarity;
- revision to Clause 9 to add the correlation coefficient, r to the report.

  • Standard
    49 pages
    English and French language
    sale 15% off

This part of IEC 60317 specifies the requirements of polyester glass-fibre wound, silicone
resin or varnish impregnated bare, grade 1 or grade 2 enamelled rectangular copper winding
wires, temperature index 200. The impregnating agent is a silicone containing resin or
varnish.
The range of nominal conductor dimensions covered by this document is:
– width: min. 2,0 mm max. 16,0 mm;
– thickness: min. 0,80 mm max. 5,60 mm.
NOTE For this type of wire, the heat shock test is inappropriate and therefore a heat shock temperature cannot be
established. Consequently, a class based on the requirements for temperature index and heat shock temperature
cannot be specified.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 60317 specifies the requirements of enamelled round aluminium winding
wires of class 200 with a dual coating. The underlying coating is based on polyester or
polyesterimide resin, which can be modified provided it retains the chemical identity of the
original resin and meets all specified wire requirements. The superimposed coating is based
on polyamide-imide resin.
NOTE A modified resin is a resin that has undergone a chemical change, or contains one or more additives to
enhance certain performance or application characteristics.
The range of nominal conductor diameters covered by this document is:
– Grade 1: 0,250 mm up to and including 3,150 mm;
– Grade 2: 0,250 mm up to and including 5,000 mm.
The nominal conductor diameters are specified in Clause 4 of IEC 60317-0-3:2008 and
IEC 60317-0-3:2008/AMD1:2013.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 60317 specifies the requirements of enamelled rectangular copper winding
wires of class 105 with a sole coating based on polyvinyl acetal resin, which can be modified
provided it retains the chemical identity of the original resin and meets all specified wire
requirements.
NOTE 1 A modified resin is a resin that has undergone a chemical change, or contains one or more additives to
enhance certain performance or application characteristics.
NOTE 2 Polyvinyl acetate is a general name for a family of thermoplastic vinyl resins produced by the
condensation of polyvinyl alcohol with an aldehyde. Examples are polyvinyl acetal, polyvinyl formal and polyvinyl
butyral.
The range of nominal conductor dimensions covered by this document is:
– width: min. 2,0 mm max. 31,5 mm;
– thickness: min. 0,80 mm max. 10,00 mm.
Wires of grade 1 and grade 2 are included in this specification and apply to the complete
range of conductors.
The specified combinations of width and thickness as well as the specified ratio of
width/thickness are given in IEC 60317-0-2.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 60317 specifies the requirements of polyester glass-fibre wound unvarnished
and fused bare, grade 1 or grade 2 enamelled round copper winding wires, temperature index
155.
The nominal conductor diameters are specified in Clause 4 of IEC 60317-0-10:2017.
NOTE For this type of wire, the heat shock test is inappropriate and therefore a heat shock temperature cannot be
established. Consequently, a class based on the requirements for temperature index and heat shock temperature
cannot be specified.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 60317 specifies the general requirements of enamelled rectangular copper
winding wires.
The range of nominal conductor dimensions is given in 4.1 and the relevant specification
sheet.

  • Standard
    30 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 60317 specifies the requirements of enamelled rectangular copper winding
wires of class 120 with a sole coating based on polyvinyl acetal or polyvinyl formal resin,
which can be modified provided it retains the chemical identity of the original resin and meets
all specified wire requirements
NOTE 1 A modified resin is a resin that has undergone a chemical change, or contains one or more additives to
enhance certain performance or application characteristics.
NOTE 2 Polyvinyl acetal is a general name for a family of thermoplastic vinyl resins produced by the
condensation of polyvinyl alcohol with an aldehyde. Examples are polyvinyl acetal, polyvinyl formal and polyvinyl
butyral.
The range of nominal conductor dimensions covered by this document is:
– width: min. 2,0 mm max. 31,5 mm;
– thickness: min. 0,80 mm max. 10,0 mm.
Wires of grade 1 and grade 2 are included in this specification and apply to the complete
range of conductors.
The specified combinations of width and thickness as well as the specified ratio
width/thickness are given in IEC 60317-0-2.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 60317 specifies the requirements of polyester glass-fibre wound, resin or
varnish impregnated, bare or grade 1 or grade 2 enamelled rectangular copper winding wires,
temperature index 155. The impregnating agent can be, for instance, epoxy, polyester, or
polyesterimide resin based.
The range of nominal conductor dimensions covered by this document is:
– width: min. 2,0 mm max. 16,0 mm;
– thickness: min. 0,80 mm max. 5,60 mm.
NOTE For this type of wire, the heat shock test is inappropriate and therefore a heat shock temperature cannot be
established. Consequently, a class based on the requirements for temperature index and heat shock temperature
cannot be specified.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 60317 specifies the requirements of paper tape covered round copper winding
wires. This covering consists of two or more layers of paper tape and is primarily intended for
winding coils for oil immersed transformers.
The range of nominal conductor diameters covered by this document is:
– 0,500 mm up to and including 5,000 mm.
The nominal conductor diameters are specified in Clause 4 of IEC 60317-0-1:2013.
The paper tapes included in this document are restricted to those specified in IEC 60554-1 and
IEC 60554-3-5.

  • Standard
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 60317 specifies the requirements of polyester glass-fibre wound fused,
unvarnished, bare or grade 1 or grade 2 enamelled rectangular copper winding wires,
temperature index 155.
NOTE For this type of wire, the heat shock test is inappropriate and therefore a heat shock temperature cannot be
established. Consequently, a class based on the requirements for temperature index and heat shock temperature
cannot be specified.
The range of nominal conductor dimensions covered by this document is:
– width: min. 2,0 mm max. 16,0 mm;
– thickness: min. 0,80 mm max. 5,60 mm.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 60317 specifies the requirements of enamelled rectangular copper winding
wires of class 200 with a sole coating based on polyesterimide resin, which can be modified
provided it retains the chemical identity of the original resin and meets all specified wire
requirements.
NOTE A modified resin is a resin that has undergone a chemical change or contains one or more additives to
enhance certain performance or application characteristics.
The range of nominal conductor dimensions covered by this document is:
– width: min. 2,0 mm max. 16,0 mm;
– thickness: min. 0,80 mm max. 5,60 mm.
Wires of grade 1 and grade 2 are included in this specification and apply to the complete range
of conductors.
The specified combinations of width and thickness as well as the specified width/thickness ratio
are given in IEC 60317-0-2.

  • Standard
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60317-0-6:2020 is available as IEC 60317-0-6:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60317-0-6:2020 specifies the general requirements of glass-fibre wound resin or varnish impregnated, bare or enamelled, round copper winding wires. The range of nominal conductor diameters is given in the relevant specification sheet. This second edition cancels and replaces the first edition published in 2001 and Amendment 1:2006. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - revision to 3.3, Appearance; - revision to Table 1, maximum overall diameter of grade 1 wire over single-glass fibre covering for nominal conductor diameters 1,600 mm - 5,000 mm; - revision to Table 2, maximum overall diameter of grade 1 wire over double-glass fibre covering for nominal conductor diameters 1,600 mm - 5,000 mm; clarification in Table 3 measurement of elongation as “minimum elongation %”.

  • Standard
    21 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 60317 specifies the requirements of paper tape covered round aluminium
winding wires. This covering consists of two or more layers of paper tape and is primarily
intended for winding coils for oil immersed transformers.
The range of nominal conductor diameters covered by this document is:
– 0,500 mm up to and including 5,000 mm.
The nominal conductor diameters are specified in Clause 4 of IEC 60317-0-3:2008 and
IEC 60317-0-3:2008/AMD1:2013.
The paper tapes included in this document are restricted to those covered in IEC 60554-1 and
IEC 60554-3-5.

  • Standard
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 60317 specifies the requirements of enamelled round copper winding wires of
class 120 with a sole coating based on polyvinyl acetal or polyvinyl formal resin, which can be
modified provided it retains the chemical identity of the original resin and meets all specified
wire requirements.
NOTE 1 A modified resin is a resin that has undergone a chemical change, or contains one or more additives to
enhance certain performance or application characteristics.
NOTE 2 Polyvinyl acetal is a general name for a family of thermoplastic vinyl resins produced by the
condensation of polyvinyl alcohol with an aldehyde. Examples are polyvinyl acetal, polyvinyl formal and polyvinyl
butyral.
The range of nominal conductor diameters covered by this document is:
– Grade 1: 0,040 mm up to and including 2,500 mm;
– Grade 2: 0,040 mm up to and including 5,000 mm;
– Grade 3: 0,080 mm up to and including 5,000 mm.
The nominal conductor diameters are specified in Clause 4 of IEC 60317-0-1:2013.

  • Standard
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 60317 specifies the requirements of paper tape covered rectangular aluminium
winding wires. This covering consists of two or more layers of paper tape and is primarily
intended for winding coils for oil immersed transformers.
The range of nominal conductor dimensions covered by this document is:
– width: min. 2,00 mm max. 16,0 mm;
– thickness: min. 0,80 mm max. 5,60 mm.
The paper tapes included in this document are restricted to those specified in IEC 60554-1 and
IEC 60554-3-5.

  • Standard
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 60317 specifies the requirements of polyester glass-fibre wound resin/varnish
impregnated bare, grade 1 or grade 2 enamelled round copper winding wires, temperature
index 155. The impregnating agent can be, for instance, epoxy, polyester, or polyesterimide
resin based.
The nominal conductor diameters are specified in Clause 4 of IEC 60317-0-10:2017.
NOTE For this type of wire, the heat shock test is inappropriate and therefore a heat shock temperature cannot be
established. Consequently, a class based on the requirements for temperature index and heat shock temperature
cannot be specified.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 60317 specifies the requirements of polyester glass-fibre wound resin/varnish
impregnated, bare, grade 1 or grade 2 enamelled round copper winding wire, temperature
index 180.
NOTE For this type of wire, the heat shock test is inappropriate and therefore a heat shock temperature cannot be
established. Consequently, a class based on the requirements for temperature index and heat shock temperature
cannot be specified.
The nominal conductor diameters are specified in IEC 60317-0-10:2017, Clause 4.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 60317 specifies general requirements of glass-fibre wound, resin or varnish
impregnated, bare or enamelled rectangular copper wire.
The range of nominal conductor dimensions is given in 4.1 and the relevant specification sheet.

  • Standard
    27 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 60317 specifies the requirements of polyester glass-fibre wound, resin or
varnish impregnated bare, grade 1 or grade 2 enamelled rectangular copper winding wires,
temperature index 180. The impregnating agent can be, for instance, epoxy, polyester, or
polyesterimide resin based.
NOTE For this type of wire, the heat shock test is inappropriate and therefore a heat shock temperature cannot be
established. Consequently, a class based on the requirements for temperature index and heat shock temperature
cannot be specified.
The range of nominal conductor dimensions covered by this document is:
– width: min. 2,0 mm max. 16,0 mm;
– thickness: min. 0,80 mm max. 5,60 mm.
The specified combinations of width and thickness as well as the specified width/thickness
ratio are according to IEC 60317-0-8.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 60317 specifies the requirements of polyester glass-fibre wound silicone
resin/varnish impregnated, bare, grade 1 or grade 2 enamelled round copper winding wire,
temperature index 200.
NOTE For this type of wire, the heat shock test is inappropriate and therefore a heat shock temperature cannot be
established. Consequently, a class based on the requirements for temperature index and heat shock temperature
cannot be specified.
The nominal conductor diameters are specified in IEC 60317-0-10:2017, Clause 4.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60317-60-2:2020 specifies the requirements of polyester glass-fibre wound, resin or varnish impregnated, bare or grade 1 or grade 2 enamelled rectangular copper winding wires, temperature index 155. The impregnating agent can be, for instance, epoxy, polyester, or polyesterimide resin based. The range of nominal conductor dimensions covered by this document is:
– width: min. 2,0 mm max. 16,0 mm;
– thickness: min. 0,80 mm max. 5,60 mm.
NOTE For this type of wire, the heat shock test is inappropriate and therefore a heat shock temperature cannot be established. Consequently, a class based on the requirements for temperature index and heat shock temperature cannot be specified.

  • Standard
    20 pages
    English and French language
    sale 15% off

IEC 60317-60-1: 2020 specifies the requirements of polyester glass-fibre wound fused, unvarnished, bare or grade 1 or grade 2 enamelled rectangular copper winding wires, temperature index 155.
NOTE For this type of wire, the heat shock test is inappropriate and therefore a heat shock temperature cannot be established. Consequently, a class based on the requirements for temperature index and heat shock temperature cannot be specified.
The range of nominal conductor dimensions covered by this document is:
width: min. 2,0 mm max. 16,0 mm;
thickness: min. 0,80 mm max. 5,60 mm.

  • Standard
    20 pages
    English and French language
    sale 15% off

IEC 60317-70-1:2020 specifies the requirements of polyester glass-fibre wound unvarnished and fused bare, grade 1 or grade 2 enamelled round copper winding wires, temperature index 155. The nominal conductor diameters are specified in Clause 4 of IEC 60317-0-10:2017.
NOTE For this type of wire, the heat shock test is inappropriate and therefore a heat shock temperature cannot be established. Consequently, a class based on the requirements for temperature index and heat shock temperature cannot be specified.

  • Standard
    20 pages
    English and French language
    sale 15% off

IEC 60317-70-2:2020 specifies the requirements of polyester glass-fibre wound resin/varnish impregnated bare, grade 1 or grade 2 enamelled round copper winding wires, temperature index 155. The impregnating agent can be, for instance, epoxy, polyester, or polyesterimide resin based. The nominal conductor diameters are specified in Clause 4 of IEC 60317-0-10:2017.
NOTE For this type of wire, the heat shock test is inappropriate and therefore a heat shock temperature cannot be established. Consequently, a class based on the requirements for temperature index and heat shock temperature cannot be specified.

  • Standard
    20 pages
    English and French language
    sale 15% off

IEC 60317-82: 2020 specifies the requirements of enamelled rectangular copper winding wires of class 200 with a sole coating based on polyesterimide resin, which can be modified provided it retains the chemical identity of the original resin and meets all specified wire requirements.
NOTE A modified resin is a resin that has undergone a chemical change or contains one or more additives to enhance certain performance or application characteristics.
The range of nominal conductor dimensions covered by this document is:
width: min. 2,0 mm max. 16,0 mm;
thickness: min. 0,80 mm max. 5,60 mm.  Wires of grade 1 and grade 2 are included in this specification and apply to the complete range of conductors. The specified combinations of width and thickness as well as the specified width/thickness ratio are given in IEC 60317-0-2.

  • Standard
    18 pages
    English and French language
    sale 15% off

IEC 60317-0-2:2020 is available as IEC 60317-0-2:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60317-0-2:2020 specifies the general requirements of enamelled rectangular copper winding wires. The range of nominal conductor dimensions is given in 4.1 and the relevant specification sheet. This fourth edition cancels and replaces the third edition published in 2013. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- revision to Clause 2 to add new normative references for specifications for copper rods;
- revision to 3.1 to add a new definition for the term “bonding layer”;
- revision to 3.2.1 to the conditions specified for tests to be carried out;
- revision to 4.5 to add requirements for minimal, nomimal and maximal overall dimensions with a bonding layer;
- revision to Clause 5 to reference specifications for rectangular and square copper rod;
- revision to Clause 6 to take into account nominal proof strength;
- revision to 8.2 to the adherence test requirement;
- revision to Clause 18 to make reference to the relevant specification sheet.

  • Standard
    53 pages
    English and French language
    sale 15% off

IEC 60317-27-2:2020 specifies the requirements of paper tape covered round aluminium winding wires. This covering consists of two or more layers of paper tape and is primarily intended for winding coils for oil immersed transformers. The range of nominal conductor diameters covered by this document is:
- 0,500 mm up to and including 5,000 mm.
The nominal conductor diameters are specified in Clause 4 of IEC 60317-0-3:2008 and IEC 60317-0-3:2008/AMD1:2013. The paper tapes included in this document are restricted to those covered in IEC 60554-1 and IEC 60554-3-5.

  • Standard
    21 pages
    English and French language
    sale 15% off

IEC 60317-62:2020 is available as IEC 60317-62:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60317-62:2020 specifies the requirements of polyester glass-fibre wound, silicone resin or varnish impregnated bare, grade 1 or grade 2 enamelled rectangular copper winding wires, temperature index 200. The impregnating agent is a silicone containing resin or varnish.The range of nominal conductor dimensions covered by this document is:
- width: min. 2,0 mm max. 16,0 mm;
- thickness: min. 0,80 mm max. 5,60 mm.
NOTE For this type of wire, the heat shock test is inappropriate and therefore a heat shock temperature cannot be established. Consequently, a class based on the requirements for temperature index and heat shock temperature cannot be specified.
This second edition cancels and replaces the first edition published in 2012. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- revision to the title of the standard to more precisely describe the construction of the wire;
- revision to Clause 1, the scope of the standard, to provide more detail of the wire construction;
- revision to 3.2.2, general winding wire requirements of the glass fibre covering.

  • Standard
    20 pages
    English and French language
    sale 15% off

IEC 60317-25:2020 is available as IEC 60317-25:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60317-25:2020 specifies the requirements of enamelled round aluminium winding wires of class 200 with a dual coating. The underlying coating is based on polyester or polyesterimide resin, which can be modified provided it retains the chemical identity of the original resin and meets all specified wire requirements. The superimposed coating is based on polyamide-imide resin.
NOTE A modified resin is a resin that has undergone a chemical change, or contains one or more additives to enhance certain performance or application characteristics.
The range of nominal conductor diameters covered by this document is:
- Grade 1: 0,250 mm up to and including 3,150 mm;
- Grade 2: 0,250 mm up to and including 5,000 mm.
The nominal conductor diameters are specified in Clause 4 of IEC 60317-0-3:2008 and IEC 60317-0-3:2008/AMD1:2013. This fourth edition cancels and replaces the third edition published in 2010. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- new 3.2.2 containing general notes on winding wire, formerly a part of the Scope;
- revision to Clause 11 to take into account intermediate nominal conductor diameters;
- revision to Clause 7 to indicate that the springiness test is inappropriate.
- revision to Clause 16 to specify only the percentage of extractable matter and the minimum retained dielectric breakdown voltage.

  • Standard
    20 pages
    English and French language
    sale 15% off

IEC 60317-0-6:2020 is available as IEC 60317-0-6:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60317-0-6:2020 specifies the general requirements of glass-fibre wound resin or varnish impregnated, bare or enamelled, round copper winding wires. The range of nominal conductor diameters is given in the relevant specification sheet. This second edition cancels and replaces the first edition published in 2001 and Amendment 1:2006. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- revision to 3.3, Appearance;
- revision to Table 1, maximum overall diameter of grade 1 wire over single-glass fibre covering for nominal conductor diameters 1,600 mm - 5,000 mm;
- revision to Table 2, maximum overall diameter of grade 1 wire over double-glass fibre covering for nominal conductor diameters 1,600 mm - 5,000 mm;
clarification in Table 3 measurement of elongation as “minimum elongation %”.

  • Standard
    37 pages
    English and French language
    sale 15% off

IEC 60317-17:2020 is available as IEC 60317-17:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60317-17:2020 specifies the requirements of enamelled rectangular copper winding wires of class 105 with a sole coating based on polyvinyl acetal resin, which can be modified provided it retains the chemical identity of the original resin and meets all specified wire requirements
NOTE 1 A modified resin is a resin that has undergone a chemical change, or contains one or more additives to enhance certain performance or application characteristics.
NOTE 2 Polyvinyl acetate is a general name for a family of thermoplastic vinyl resins produced by the condensation of polyvinyl alcohol with an aldehyde. Examples are polyvinyl acetal, polyvinyl formal and polyvinyl butyral. The range of nominal conductor dimensions covered by this document is:
- width: min. 2,0 mm max. 31,5 mm;
- thickness: min. 0,80 mm max. 10,00 mm.
Wires of grade 1 and grade 2 are included in this specification and apply to the complete range of conductors. The specified combinations of width and thickness as well as the specified ratio of width/thickness are given in IEC 60317-0-2. This fourth edition cancels and replaces the third edition published in 2010. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- modification of the Scope (Clause 1);
- renaming of stretching test to adherence test and a modification of the requirement in 8.2.

  • Standard
    20 pages
    English and French language
    sale 15% off

IEC 60317-12:2020 is available as IEC 60317-12:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60317-12:2020 specifies the requirements of enamelled round copper winding wires of class 120 with a sole coating based on polyvinyl acetal or polyvinyl formal resin, which can be modified provided it retains the chemical identity of the original resin and meets all specified wire requirements.
NOTE 1 A modified resin is a resin that has undergone a chemical change, or contains one or more additives to enhance certain performance or application characteristics.
NOTE 2 Polyvinyl acetal is a general name for a family of thermoplastic vinyl resins produced by the condensation of polyvinyl alcohol with an aldehyde. Examples are polyvinyl acetal, polyvinyl formal and polyvinyl butyral. The range of nominal conductor diameters covered by this document is:
- Grade 1: 0,040 mm up to and including 2,500 mm;
- Grade 2: 0,040 mm up to and including 5,000 mm;
- Grade 3: 0,080 mm up to and including 5,000 mm.
The nominal conductor diameters are specified in Clause 4 of IEC 60317-0-1:2013. This fourth edition of IEC 60317-12 cancels and replaces the third edition published in 2010. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- modification of the Scope;
- addition of reference to transformer oil resistance test method in Clause 20.

  • Standard
    22 pages
    English and French language
    sale 15% off

IEC 60317-18:2020 is available as IEC 60317-18:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60317-18:2020 specifies the requirements of enamelled rectangular copper winding wires of class 120 with a sole coating based on polyvinyl acetal or polyvinyl formal resin, which can be modified provided it retains the chemical identity of the original resin and meets all specified wire requirements
NOTE 1 A modified resin is a resin that has undergone a chemical change, or contains one or more additives to enhance certain performance or application characteristics.
NOTE 2 Polyvinyl acetate is a general name for a family of thermoplastic vinyl resins produced by the condensation of polyvinyl alcohol with an aldehyde. Examples are polyvinyl acetal, polyvinyl formal and polyvinyl butyral.
The range of nominal conductor dimensions covered by this document is:
- width: min. 2,0 mm max. 31,5 mm;
- thickness: min. 0,80 mm max. 10,0 mm.
Wires of grade 1 and grade 2 are included in this specification and apply to the complete range of conductors. The specified combinations of width and thickness as well as the specified ratio width/thickness are given in IEC 60317-0-2. This fourth edition cancels and replaces the third edition published in 2004 and Amendment 1:2009. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- modification of the Scope (Clause 1);
- revision to thermal class designation from 105 to 120 in 3.2.2;
- renaming of stretching test to adherence test, and modification to the requirements in 8.2;
- revision to the cut-through requirement in Clause 10.

  • Standard
    20 pages
    English and French language
    sale 15% off

IEC 60317-27-4:2020 specifies the requirements of paper tape covered rectangular aluminium winding wires. This covering consists of two or more layers of paper tape and is primarily intended for winding coils for oil immersed transformers. The range of nominal conductor dimensions covered by this document is:
– width: min. 2,00 mm max. 16,0 mm;
– thickness: min. 0,80 mm max. 5,60 mm.
The paper tapes included in this document are restricted to those specified in IEC 60554-1 and IEC 60554-3-5.

  • Standard
    21 pages
    English and French language
    sale 15% off

IEC 60317-27-1:2020 specifies the requirements of paper tape covered round copper winding wires. This covering consists of two or more layers of paper tape and is primarily intended for winding coils for oil immersed transformers. The range of nominal conductor diameters covered by this document is:
– 0,500 mm up to and including 5,000 mm.
The nominal conductor diameters are specified in Clause 4 of IEC 60317-0-1:2013.
The paper tapes included in this document are restricted to those specified in IEC 60554-1 and IEC 60554-3-5.

  • Standard
    21 pages
    English and French language
    sale 15% off

IEC 60317-61:2020 is available as IEC 60317-61:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60317-61:2020 specifies the requirements of polyester glass-fibre wound, resin or varnish impregnated bare, grade 1 or grade 2 enamelled rectangular copper winding wires, temperature index 180. The impregnating agent can be, for instance, epoxy, polyester, or polyesterimide resin based. NOTE For this type of wire, the heat shock test is inappropriate and therefore a heat shock temperature cannot be established. Consequently, a class based on the requirements for temperature index and heat shock temperature cannot be specified. The range of nominal conductor dimensions covered by this document is:
- width: min. 2,0 mm max. 16,0 mm;
- thickness: min. 0,80 mm max. 5,60 mm.
The specified combinations of width and thickness as well as the specified width/thickness ratio are according to IEC 60317-0-8. This second edition cancels and replaces the first edition published in 2012. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- revision of the title of the standard;
- revision to Clause 1, Scope;
- revision to the descriptions of grades of thickness of polyester glass-fibre coverings in 3.2.2.

  • Standard
    20 pages
    English and French language
    sale 15% off

IEC 60317-0-4:2020 is available as IEC 60317-0-4:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60317-0-4:2020 specifies general requirements of glass-fibre wound, resin or varnish impregnated, bare or enamelled rectangular copper wire.The range of nominal conductor dimensions is given in 4.1 and the relevant specification sheet. This fourth edition cancels and replaces the third edition published in 2015. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- addition of dimensional requirements for grade 1 enamelled wire in Table 4;
- addition of dielectric breakdown requirements for grade 1 enamelled wire in Table 7.
- addition of requirement for the adherence test in 8.2.1 and 8.2.2.

  • Standard
    49 pages
    English and French language
    sale 15% off

IEC 60317-72:2020 is available as IEC 60317-72:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60317-72: 2020 specifies the requirements of polyester glass-fibre wound silicone resin/varnish impregnated, bare, grade 1 or grade 2 enamelled round copper winding wire, temperature index 200. NOTE For this type of wire, the heat shock test is inappropriate and therefore a heat shock temperature cannot be established. Consequently, a class based on the requirements for temperature index and heat shock temperature cannot be specified. The nominal conductor diameters are specified in IEC 60317-0-10:2017, Clause 4. This second edition cancels and replaces the first edition published in 2017. The document 55/1768/CDV, circulated to the National Committees as Amendment 1, led to the publication of this new edition. This edition includes the following significant technical changes with respect to the previous edition:
- modification of the title;
- revision to the Scope;
- revision to 3.2.2.

  • Standard
    20 pages
    English and French language
    sale 15% off

IEC 60317-71:2020 is available as IEC 60317-71:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60317-71:2020 specifies the requirements of polyester glass-fibre wound resin/varnish impregnated, bare, grade 1 or grade 2 enamelled round copper winding wire, temperature index 180. NOTE For this type of wire, the heat shock test is inappropriate and therefore a heat shock temperature cannot be established. Consequently, a class based on the requirements for temperature index and heat shock temperature cannot be specified. The nominal conductor diameters are specified in IEC 60317-0-10:2017, Clause 4. This second edition cancels and replaces the first edition published in 2017. The document 55/1767/CDV, circulated to the National Committees as Amendment 1, led to the publication of this new edition. This edition includes the following significant technical changes with respect to the previous edition:
- modification of the title;
- revision to the Scope;
- revision to 3.2.2.

  • Standard
    20 pages
    English and French language
    sale 15% off

IEC TS 62607-2-4:2020 specifies the test method for determining the resistivity and the contact resistance of an individual CNT and the dependability of the measurement.
This document includes:
– outlines of the experimental procedures used to measure resistance of carbon nanotubes,
– methods of interpretation of results and discussion of data analysis, and
– case studies.

  • Technical specification
    19 pages
    English language
    sale 15% off

IEC TS 62607-8-1:2020 There are two types of thermally stimulated current (TSC) measurement methods, classified by the origin of the current. One is generated by the detrapping of charges. The other one is generated by depolarization. IEC TS 62607-8-1:2020 focuses on the former method, and specifies the measurement method to be developed for determining defect states of nano-enabled metal-oxide interfacial devices.
IEC TS 62607-8-1:2020 includes:
– outlines of the experimental procedures used to measure TSC,
– methods of interpretation of results and discussion of data analysis, and
– case studies.

  • Technical specification
    29 pages
    English language
    sale 15% off

This document describes laser radiation hazards arising in laser processing machines, as defined in 3.7. It also specifies the safety requirements relating to laser radiation hazards, as well as the information to be supplied by the manufacturers of such equipment (in addition to that prescribed by IEC 60825).
Requirements dealing with noise as a hazard from laser processing machines are included in ISO 11553‑3:2013.
This document is applicable to machines using laser radiation to process materials.
It is not applicable to laser products, or equipment containing such products, which are manufactured solely and expressly for the following applications:
- photolithography;
- stereolithography;
- holography;
- medical applications (per IEC 60601-2-22);
- data storage.

  • Standard