This document specifies the characteristics of electrical cables for use in the on-board electrical systems of aircraft at operating temperatures between -55 °C and 260 °C for cross sections equal to and greater than 5 mm2.

  • Standard
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies a method of testing flexure endurance of the cable when it is subjected to alternating flexing.
It shall be used together with EN 3475-100.

  • Standard
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60502-1:2021 is available as IEC 60502-1:2021 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60502-1:2021 specifies the construction, dimensions and test requirements of power cables with extruded solid insulation for rated AC voltages of 1 kV (Um = 1,2 kV) and 3 kV (Um = 3,6 kV) for fixed installations such as distribution networks or industrial installations. Cables of rated AC voltage 1 kV (Um = 1,2 kV) designed and tested in accordance with this document can also be used, if declared by the manufacturer, in DC distribution systems having their nominal voltage ≤ 750 V DC (with a maximum of 900 V DC) between a live conductor and neutral/earth, or ≤ 1 500 V DC (with a maximum 1 800 V DC) between two live conductors. Applicable core identification for DC systems are considered in accordance with local installation regulations.

  • Standard
    55 pages
    English language
    sale 15% off

This standard specifies the procedure for testing the resistance to vertical flame propagation for a single vertical electrical insulated conductor or cable, or optical fibre cable, under fire conditions.

  • Amendment
    4 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Amendment
    4 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document contains the requirements for covered conductors with or without integrated longitudinal watertightness and/or semi-conductive conductor screen for applications in overhead lines with rated voltages U above 1 kV a.c. and not exceeding 36 kV a.c.

  • Standard
    28 pages
    English language
    sale 10% off
    e-Library read for
    1 day

EN 60332-3-10:2018 details the apparatus and its arrangement and calibration for methods of test for the assessment of vertical flame spread of vertically mounted bunched wires or cables, electrical or optical, under defined conditions.

  • Amendment
    3 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document details a designation system for harmonised power cables and cords according to EN 50525 (series), EN 50214, EN 50618 and EN 50620.
NOTE The use of the system for Recognised National Types of cable or cord has been withdrawn by CLC/TC 20. For non-harmonised cables National Committees are permitted to use any designation that does not conflict with this HD, but see Tables 2 and 4 for recommendations.

  • Standardization document
    11 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standardization document
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60840:2020 is available as IEC 60840:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60840:2020 specifies test methods and requirements for power cable systems, cables alone and accessories alone, for fixed installations and for rated voltages above 30 kV (Um = 36 kV) up to and including 150 kV (Um = 170 kV). The requirements apply to single-core cables and to individually screened three-core cables and to their accessories for usual conditions of installation and operation, but not to special cables, such as submarine cables and their accessories, for which modifications to the standard tests or the setup of special test conditions can be necessary. This document does not cover transition joints between cables with extruded insulation and paper insulated cables. This fifth edition cancels and replaces the fourth edition, published in 2011. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- Gas immersed cable terminations for use at rated voltages above 52 kV are required to be designed, type and routine tested in accordance with IEC 62271-209 in addition to the routine and type tests specified in this document.
- Requirements are introduced for composite outdoor termination insulators.
- The test cylinder diameters specified for the bending test (type and prequalification tests) have been modified in line with IEC TR 61901:2016.
- A low smoke halogen free oversheath material, designated ST12 is introduced.
- Additional tests under fire conditions are introduced: vertical flame spread, smoke density, acidity and conductivity, which shall be applied according to the fire performance declared for the cable.
- A test for water penetration in the conductor is added.
- In addition to tests on the outer protection of joints, type tests on the screen sectionalizing insulation of all accessories have been introduced.
The contents of the corrigendum of February 2021 have been included in this copy.

  • Standard
    163 pages
    English and French language
    sale 15% off

20200205: Corrigendum requested by ASD-STAN due to a mistake of the key in Figure 2 (symbols inverted in the original text provided to CCMC). SS

  • Corrigendum
    2 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 62893-4-1:2020 applies to cables for DC charging according to mode 4 of IEC 61851-1. These cables are not intended to be used with a thermal management system such as that specified in IEC 61851-23.
Charging cables specified in IEC 62893 (all parts) are intended to be used for electrical appliances of class II equipment.
The maximum conductor operating temperature for the cables in this document is 90 °C.
The test methods specified are given in IEC 62893-2, IEC 60245-2, IEC 60332-1-2, IEC 62821‑1:2015, Annex B and in the relevant parts of IEC 60811.
IEC 62440 is intended to be used as guidance on the safe use of cables in this document together with Clause 5 of this document.
This document is to be read in conjunction with IEC 62893-1:2017 and IEC 62893-2:2017.

  • Standard
    18 pages
    English language
    sale 15% off

EN 50306-4 specifies requirements for, and constructions and dimensions of, multicore and multipair cables rated voltage Uo/U: 300/500 V, of the following types:
- unscreened, sheathed for either exposed or protected wiring, 0,5 mm2 to 2,5 mm2, number of cores from 2 to 48;
- screened, sheathed for either exposed or protected wiring, 0,5 mm2 to 2,5 mm2, number of cores from 2 to 8;
- unscreened, sheathed for either exposed or protected wiring, 0,5 mm2 to 1,5 mm2, number of screened pairs of cores from 2 to 7;
- screened, sheathed for either exposed or protected wiring, 0,5 mm2 to 1,5 mm2, number of unscreened pairs of cores from 2 to 7.

  • Standard
    30 pages
    English language
    sale 10% off
    e-Library read for
    1 day

EN 50306-2 specifies requirements for, and constructions and dimensions of, single core cables, rated voltage Uo / U= 300 /300 V, of the following type:  Unscreened, 0,5 mm2 to 2,5 mm2 single core

  • Standard
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard specifies special test methods applicable to cables, and their constituent insulating and sheathing materials, for use in railway rolling stock.  Such cables are specified in the various parts of EN 50264, EN 50306 and EN 50382.

  • Standard
    43 pages
    English language
    sale 10% off
    e-Library read for
    1 day

EN 50306-3 specifies requirements for, and constructions and dimensions of, multicore cables, rated voltage Uo/U=300/500 V, of the following type: Screened, 0,5 mm2 to 2,5 mm2, number of cores from 1 to 8. All cables have stranded tinned copper conductors, and thin wall thickness, halogen-free, insulation and sheath. They are for use in railway rolling stock as fixed wiring, or wiring where limited flexing in operation is encountered.

  • Standard
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day

EN 50306 1 specifies the general requirements applicable to the cables given EN 50306 2, EN 50306 3 and EN 50306 4. It includes the detailed requirements for S2 sheathing materials and other components called up in the separate Parts. In particular EN 50306 1 specifies those requirements relating to fire safety which enable the cables to satisfy Hazard Level3 of EN 45545-1 and -2.

  • Standard
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day

2019-02-01 PeC: removed from citation under the LVD, TC confirmed it is a test method standard

  • Amendment
    8 pages
    English language
    sale 10% off
    e-Library read for
    1 day

2019-02-01 PeC: removed from citation under the LVD, TC confirmed it is a test method standard

  • Amendment
    9 pages
    English language
    sale 10% off
    e-Library read for
    1 day

EN 50306-1 specifies the general requirements applicable to the cables given in EN 50306-2, EN 50306-3 and EN 50306-4. It includes the detailed requirements for S2 sheathing materials and other components called up in the separate parts. NOTE Detailed requirements for insulation systems are given in EN 50306-2. In particular, EN 50306-1 specifies those requirements relating to fire safety which enable the cables to satisfy Hazard Level 3 of EN 45545-1 and EN 45545-2. These cables are rated for occasional thermal stresses which causes ageing equivalent to continuous operational life at a temperature of 105 °C or 90 °C. For standard cables, this is determined by the acceptance test defined in EN 50305, using accelerated long-term (5 000 h) thermal ageing indicating a 125 °C or 110 °C /20 000 h temperature index. If the customer were to require lifetime predictions, this would be demonstrated based on the temperature index of the product as supplied by the manufacturer. The maximum temperature for short circuit conditions is 160 °C based on duration of 5 s. EN 50306-1 is expected to be used in conjunction with one or more of the other parts of EN 50306.

  • Standard
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies requirements for, and constructions and dimensions of, multicore cables, rated voltage U0/ U = 300/500 V, of the following type: Screened (0,5 mm2 to 2,5 mm2, number of cores from 1 to 8). All cables have stranded tinned copper conductors, and thin wall thickness, halogen-free, insulation and sheath. They are for use in railway rolling stock as fixed wiring or wiring where limited flexing in operation is encountered. These cables are rated for occasional thermal stresses causing ageing equivalent to continuous operational life at a temperature of 90 °C. For standard cables, this is determined by the acceptance test defined in EN 50305, using accelerated long-term (5 000 h) thermal ageing indicating a 110 °C/20 000 h temperature index. If the customer were to require lifetime predictions this would be demonstrated based on the temperature index of the product as supplied by the manufacturer. The maximum temperature for short circuit conditions is 160 °C based on duration of 5 s. Under fire conditions, the cables exhibit special performance characteristics in respect of maximum permissible flame propagation (flame spread) and maximum permissible emission of smoke and toxic gases. These requirements are specified to permit the cables to satisfy Hazard Level 3 of EN 45545 1 and EN 45545 2. EN 50306 3:2020 is expected to be used in conjunction with EN 50306 1:2020, General Requirements, and EN 50306 2:2020, Single core cables.

  • Standard
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies requirements for, and constructions and dimensions of, multicore and multipair cables rated voltage U0/U: 300/500 V, of the following types: - unscreened, sheathed for either exposed or protected wiring (0,5 mm2 to 2,5 mm2, number of cores from 2 to 48); - screened, sheathed for either exposed or protected wiring (0,5 mm2 to 2,5 mm2, number of cores from 2 to 8); - unscreened, sheathed for either exposed or protected wiring (0,5 mm2 to 1,5 mm2, number of screened pairs of cores from 2 to 7). - screened, sheathed for either exposed or protected wiring (0,5 mm2 to 1,5 mm2, number of unscreened pairs of cores from 2 to 7). All cables have stranded tinned copper conductors, halogen-free, thin wall thickness insulation and standard wall thickness sheath. Cable types are specified for use in exposed situations (Class E), and for protected situations (Class P). They are for use in railway rolling stock as fixed wiring or wiring where limited flexing in operation is encountered. These cables are rated for occasional thermal stresses causing ageing equivalent to continuous operational life at a temperature of 90 °C. For standard cables this is determined by the acceptance test defined in EN 50305, using accelerated long-term (5 000 h) thermal ageing indicating a 110 °C/20 000 h temperature index. If the customer were to require lifetime predictions this would be demonstrated based on the temperature index of the product as supplied by the manufacturer. The maximum temperature for short circuit conditions is 160 °C based on duration of 5 s. Under fire conditions the cables exhibit special performance characteristics in respect of maximum permissible flame propagation (flame spread) and maximum permissible emission of smoke and toxic gases. These requirements are specified to permit the cables to satisfy Hazard Level 3 of EN 45545 1 and EN 45545 2. EN 50306 4:2020 is expected to be used in conjunction with EN 50306-1:2020, General requirements, EN 50306-2:2020, Single core cables, and EN 50306-3:2020, Single core and multicore cables.

  • Standard
    30 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies special test methods applicable to cables, and their constituent insulating and sheathing materials, for use in railway rolling stock. Such cables are specified in the various parts of the EN 50264 series, EN 50306 series and EN 50382 series. Other test methods required for railway rolling stock cables and their insulating and sheathing materials are listed in Annex A.

  • Standard
    43 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies requirements for, and constructions and dimensions of, single core cables, rated voltage U0 / U = 300 /300 V, of the following type: Unscreened (0,5 mm2 to 2,5 mm2 single core) These cables are rated for occasional thermal stresses causing ageing equivalent to continuous operational life at a temperature of 105 °C. For standard cables, this is determined by the acceptance test defined in EN 50305, using accelerated long-term (5 000 h) thermal ageing indicating a 125 °C/20 000 h temperature index. If the customer were to require lifetime predictions, this would be demonstrated based on the temperature index of the product as supplied by the manufacturer. The maximum temperature for short circuit conditions is 160 °C based on duration of 5 s. Under fire conditions the cables exhibit special performance characteristics in respect of maximum permissible flame propagation (flame spread) and maximum permissible emission of smoke and toxic gases. These requirements are specified to permit the cables to satisfy Hazard Level 3 of EN 45545 1 and EN 45545 2. EN 50306-2:2020 is expected to be used in conjunction with EN 50306-1:2020, General requirements.

  • Standard
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day

2019-02-01 PeC: removed from citation under the LVD, TC confirmed it is a test method standard

  • Amendment
    5 pages
    English language
    sale 10% off
    e-Library read for
    1 day

2019-02-01 PeC: removed from citation under the LVD, TC confirmed it is a test method standard

  • Amendment
    5 pages
    English language
    sale 10% off
    e-Library read for
    1 day

EN 3475-513 defines the test methods to evaluate the performance of coaxial, quadrax and databus cables after the installation of plastic cable ties.It shall be used together with EN 3475-100.

  • Standard
    11 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    11 pages
    English language
    sale 10% off
    e-Library read for
    1 day

2019-02-04 - GEM - linkto LVD removed - no hEN  -  no assessment
2019-02-01 PeC: removed from citation under the LVD, TC confirmed it is a test method standard

  • Amendment
    9 pages
    English language
    sale 10% off
    e-Library read for
    1 day

2019-02-04 - GEM - link to LVD removed - no hEN  -  no assessment
2019-02-01 PeC: removed from citation under the LVD, TC confirmed it is a test method standard

  • Amendment
    8 pages
    English language
    sale 10% off
    e-Library read for
    1 day

2019-02-04 - GEM - linkto LVD removed - no hEN  -  no assessment
2019-02-01 PeC: removed from citation under the LVD, TC confirmed it is a test method standard

  • Amendment
    5 pages
    English language
    sale 10% off
    e-Library read for
    1 day

2019-03-22: BT D162/C049 removes link to 2014/35/EU (standard kept as supporting standard)
2019-02-01 PeC: removed from citation under the LVD, TC confirmed it is a test method standard

  • Amendment
    5 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60092-354:2020 is available as IEC 60092-354:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60092-354:2020 is applicable to shipboard and offshore power cables with extruded solid insulation, conductor and core screening, having a voltage rating of one of the following: 3,6/6 (7,2) kV,6/10 (12) kV, 8,7/15 (17,5) kV, 12/20 (24) kV, 18/30 (36) kV. The cables are intended for fixed installations. The various types of power cables are given in 5.1. The constructional requirements and test methods are aligned with those indicated in IEC 60092-350, unless otherwise specified in this document.
The object of this document is:
- to standardize cables whose safety and reliability is ensured when they are installed in accordance with the requirements of IEC 60092-352 or IEC 61892-4;
- to lay down standard manufacturing requirements and characteristics of such cables directly or indirectly bearing on safety;
- to specify test methods for checking conformity with those requirements.
Only radial field cables are covered. This fourth edition cancels and replaces the third edition published in 2014. This edition constitutes a technical revision.

  • Standard
    36 pages
    English and French language
    sale 15% off

IEC 60092-350:2020 is available as IEC 60092-350:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60092-350:2020 provides the general constructional requirements and test methods for use in the manufacture of electric power, control and instrumentation cables with copper conductors intended for fixed electrical systems at voltages up to and including 18/30(36) kV on board ships and offshore (mobile and fixed) units.
The reference to fixed systems includes those that are subjected to vibration (due to the movement of the ship or installation) or movement (due to motion of the ship or installation) and not to those that are intended for frequent flexing. Cables suitable for frequent or continual flexing use are detailed in other IEC standards, for example IEC 60227 (all parts) and IEC 60245 (all parts), and their uses are restricted to those situations which do not directly involve exposure to a marine environment, for example, portable tools and domestic appliances.
The following types of cables are not included:
- optical fibre;
- sub-sea and umbilical cables;
- data and communication cables;
- coaxial cables.
This fifth edition cancels and replaces the fourth edition published in 2014 and constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) more detailed description of the test procedures in 7.7.6 and 7.7.7;
b) description of the relationship between Annex A and Annex D.

  • Standard
    107 pages
    English and French language
    sale 15% off

This document specifies the characteristics, test methods, qualification and acceptance conditions of single and multicore electric cables for general purpose with conductors in aluminium or copper-clad aluminium, intended for installation in aircraft electrical systems. The insulation of these cables is designed to withstand aircraft voltages at a frequency not exceeding 2 000 Hz. Unless specified by individual product standards the maximum demonstrated voltage of rating of these cables is ac 115 V rms phase to neutral and 200 V rms phase to phase and 28 Vdc. They are divided into types, the characteristics of which are given in the product standards. Unless otherwise specified in the product standard, the tests defined in this standard apply.

  • Standard
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 63026:2019 specifies test methods and requirements for power cable systems, cables with extruded insulation and their accessories for fixed submarine installations, for rated voltages from 6 kV (Um = 7,2 kV) up to 60 kV (Um = 72,5 kV).
This document includes the electrical tests and the physical tests on materials and components as well as the specific mechanical tests that are applicable to submarine cable systems.
The requirements apply to armoured single-core cables and three-core cables in combination with their accessories, terminations and joints for usual conditions of installation and operation, but not to special cables and their accessories, such as submarine cables for dynamic applications (i.e. for direct connection to a floating structure), for which modifications to the standard tests can be necessary or special test conditions be devised.
This document is applicable to submarine cables installed in permanently submerged conditions with water depths up to 250 m.
This document does not include accessories having a mechanical function only, such as hang-offs or armour clamps.

  • Standard
    71 pages
    English language
    sale 15% off

IEC TR 60092-370:2019 is available as IEC TR 60092-370:2019 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC TR 60092-370:2019 gives guidance and lays down the basic recommendations for the selection and installation of shipboard and offshore unit cables intended for electrical systems used in both essential and non-essential analogue or digital signal communication, transmission and control networks, including types suitable for high-frequency signals (i.e. signals with a frequency of more than 105 Hz). These cables are not suitable for direct connection to low impedance supplies. Where such cables are required, attention is drawn to IEC 60092-353. Cables intended to have limited circuit integrity (fire resistance) when affected by fire are not covered by this document. Fibre optical cables are not included. Sub-sea or umbilical cables are not included. This second edition cancels and replaces the first edition published in 2009. This edition constitutes a technical revision. This edition includes the following significant technical change with respect to the previous edition: 30 V AC was added in voltage rating for data cables.

  • Technical report
    18 pages
    English language
    sale 15% off

This standard specifies the required characteristics of a coaxial cable, 50 ?, type WM, for use in aircraft electrical systems at operating temperature between - 55 °C and 200 °C and specially for high frequency up to 5 GHz.

  • Standard
    11 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard specifies the characteristics of a UV laser printable coaxial cable, 50 ?, type WZ, for use in aircraft electrical systems at operating temperatures between ? 65 °C and 200 °C and especially for high frequency up to 3 GHz.

  • Standard
    11 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the characteristics of UV laser printable jacket, silver plated copper conductor, electrical cables Crosslinked Ethylene Tetra Fluoro Ethylene co-polymer (XLETFE) family for use in the on-board electrical systems of aircraft operating at temperatures between - 65 °C and 150 °C, operating at voltages not exceeding 600 V rms at sea level. This insulation system has been used in aerospace applications using 115 V (phase-to-neutral) 400 Hz ac and 28 Vdc. Verification of the suitability of cables for use in other electrical systems is the responsibility of the user.
These jacketed cables are suitable for airframe use without additional protection when the jacket is present. When the jacket is stripped back the cores may need additional protection. In case of conflict between this document and other referenced documents the requirements of this document shall take precedence.

  • Standard
    11 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of EN 61238 applies to compression and mechanical connectors for power cables for rated voltages up to 1 kV (Um = 1,2 kV), for example buried cables or cables installed in buildings, having
a)   conductors complying with EN 60228 having nominal cross-sectional areas between 2,5 mm2 and 1 200 mm2 for copper and between 16 mm2 and 1 200 mm2 for aluminium;
b)   a maximum continuous conductor temperature not exceeding 90 °C.
This document is not applicable to connectors for overhead line conductors nor to connectors with a sliding contact.
The object of this document is to define the type test methods and requirements which apply to compression and mechanical connectors for power cables with copper or aluminium conductors. The reference method is to perform the tests on unused conductors.

  • Standard
    44 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of EN 61238 applies to compression and mechanical connectors for power cables for rated voltages above 1 kV (Um = 1,2 kV) up to 36 kV (Um = 42 kV), for example buried cables or cables installed in buildings, having
a) conductors complying with EN 60228 having nominal cross-sectional areas between 2,5 mm2 and 1 200 mm2 for copper and between 16 mm2 and 1 200 mm2 for aluminium, excluding Milliken conductors;
b) a maximum continuous conductor temperature not exceeding 90 °C.
This document is not applicable to connectors for overhead line conductors nor to connectors with a sliding contact.
The object of this document is to define the type test methods and requirements which apply to compression and mechanical connectors for power cables with copper or aluminium conductors. The reference method is to perform the tests on unused conductors.

  • Standard
    47 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of EN 61238 applies to compression and mechanical connectors for power cables for rated voltages above 1 kV (Um = 1,2 kV) up to 36 kV (Um = 42 kV), for example buried cables or cables installed in buildings, having
a) conductors complying with EN 60228 having nominal cross-sectional areas between 2,5 mm2 and 1 200 mm2 for copper and between 16 mm2 and 1 200 mm2 for aluminium, excluding Milliken conductors;
b) a maximum continuous conductor temperature not exceeding 90 °C.
This document is not applicable to connectors for overhead line conductors nor to connectors with a sliding contact.
The object of this document is to define the type test methods and requirements which apply to compression and mechanical connectors for power cables with copper or aluminium conductors. The reference method is to perform the tests on unused conductors.

  • Amendment
    3 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of EN 61238 applies to insulation piercing connectors for power cables for rated voltages up to 1 kV (Um = 1,2 kV), for example according to HD 603 or other buried cables and cables installed in buildings, having
a) conductors complying with EN 60228 having nominal cross-sectional areas between 2,5 mm2 and 300 mm2 for copper and between 16 mm2 and 500 mm2 for aluminium,
b) a maximum continuous cable temperature not exceeding the insulation material properties.
This document is not applicable to connectors for overhead line conductors nor to connectors with a sliding contact.  
The object of this document is to define the type test methods and requirements, which apply to insulation piercing connectors for power cables with copper or aluminium conductors. The reference method is to perform the tests on unused insulated conductors.

  • Standard
    58 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the characteristics of UV laser printable jacket, nickel plated copper conductor, electrical cables Crosslinked Ethylene Tetra Fluoro Ethylene co-polymer (XLETFE) family for use in the on-board electrical systems of aircraft at operating temperatures between – 65 °C and 150 °C, operating at voltages not exceeding 600 V rms. This insulation system has been used in aerospace applications using 115 V (phase-to-neutral) 400 Hz ac and 28 Vdc. Verification of the suitability of cables for use on other electrical systems is the responsibility of the user.
These cables are suitable for airframe use without additional protection. In case of conflict between this document and other referenced documents the requirements of this document shall take precedence.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the characteristics of UV laser printable jacket, nickel plated copper conductor, electrical cables Crosslinked Ethylene Tetra Fluoro Ethylene co-polymer XLETFE family for use in the onboard electrical systems of aircraft at operating temperatures between - 65 °C and 150 °C, operating at voltages not exceeding 600 V. This insulation system has been used in aerospace applications using 115 V (phase-to-neutral) 400 Hz ac and 28 Vdc. Verification of the suitability of cables for use in other electrical systems is the responsibility of the user. These cables are suitable for airframe use without additional protection. In case of conflict between this standard and other referenced documents the requirements of this standard shall take precedence.

  • Standard
    8 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the characteristics of UV laser printable jacket, silver plated copper conductor, electrical cables Crosslinked Ethylene Tetra Fluoro Ethylene co-polymer (XLETFE) family for use in the on-board electrical systems of aircraft operating at temperatures between − 65 °C and 150 °C, operating at voltages not exceeding 600 V rms at sea level and frequencies not exceeding 2 000 Hz. This insulation system has been used in aerospace applications using 115 V (phase-to-neutral) 400 Hz ac and 28 Vdc. Verification of the suitability of cables for use in other electrical systems is the responsibility of the user. These cables are suitable for airframe use without additional protection. In case of conflict between this standard and other referenced documents the requirements of this standard shall take precedence.

  • Standard
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the characteristics of UV laser printable jacket, silver plated copper conductor, electrical cables Crosslinked Ethylene Tetra Fluoro Ethylene co-polymer XLETFE family for use in the on board electrical systems of aircraft at operating temperatures between - 65 °C and 150 °C, operating at voltages not exceeding 600 V. This insulation system has been used in aerospace applications using 115 V (phase-to-neutral) 400 Hz ac and 28 Vdc. Verification of the suitability of cables for use in other electrical systems is the responsibility of the user.
These cables are suitable for airframe use without additional protection. In case of conflict between this document and other referenced documents the requirements of this document shall take precedence.

  • Standard
    8 pages
    English language
    sale 10% off
    e-Library read for
    1 day