M/BC/CEN/92/46 - ATEX
Standardization mandate assigned to CEN/CENELEC concerning equipment and protective systems intended for use in potentially explosive atmospheres
Mandate M/BC/CEN/92/46 assigns CEN and CENELEC the task of developing harmonized standards for equipment and protective systems used in potentially explosive atmospheres. This mandate supports the implementation of the ATEX Directive, ensuring safety and compliance within the European Union by standardizing technical requirements. The objective is to facilitate a high level of protection for workers and reduce risks associated with explosive environments through consistent and reliable standardization.
Purpose
The mandate M/BC/CEN/92/46 aims to develop harmonized European standards for equipment and protective systems intended for use in potentially explosive atmospheres. These standards help ensure safety and compliance within the European Union, supporting the implementation of relevant directives and regulations related to explosion protection.
Standardisation request
CEN and CENELEC are requested to develop or update standards that specify requirements, testing methods, and conformity assessment procedures for equipment and protective systems used in environments where explosive atmospheres may occur. The focus is on mitigating risks arising from flammable gases, vapors, dust, or fibers.
Expected deliverables
- Harmonized European Standards (EN and EN IEC standards) covering a broad range of products and protective systems designed for explosive atmospheres.
- Standards that align with European Union legal requirements, including directives such as the ATEX Directive 2014/34/EU.
- Guidelines for manufacturers, testing bodies, and certification entities to ensure safe design, manufacture, and use of equipment in explosive environments.
Context
Potentially explosive atmospheres pose significant safety risks in various industrial sectors such as chemical, pharmaceutical, mining, and oil and gas. The ATEX (Atmosphères Explosibles) directives establish EU-wide requirements to protect workers and equipment from explosion risks. Standardisation under this mandate supports regulatory harmonization and facilitates the free movement of compliant products within the EU internal market. This mandate contributes to enhancing occupational safety and environmental protection by providing consistent technical specifications for explosion protection equipment and systems.
This mandate covers the standardization of equipment and protective systems intended for use in potentially explosive atmospheres. It focuses on ensuring safety and regulatory compliance for products operating in environments where explosive gases, vapors, or dusts may be present. The scope includes the development of European standards for the design, manufacturing, and testing of such equipment and systems to prevent ignition and hazards in these hazardous areas.
General Information
Creating an amendment to list the EN IEC 60079-15:2019 in OJEU by submitting European elements (Annex ZZ and Annex ZA)
- Amendment8 pagesEnglish languagee-Library read for1 day
Creating an amendment to list the EN IEC 60079-15:2019 in OJEU by submitting European elements (Annex ZZ and Annex ZA)
- Amendment8 pagesEnglish languagee-Library read for1 day
- Amendment11 pagesEnglish languagee-Library read for1 day
This document specifies requirements, test and assessment methods, marking, labelling and packaging applicable to overfill prevention devices with closure device. The devices are usually composed by:
- sensor;
- evaluation device;
- closure device.
Overfill prevention devices intended to be used in/with underground and/or above ground, non-pressurized, static tanks designed for liquid fuels.
NOTE Liquid fuel means liquids for internal combustion engines, heating/cooling boilers and generators.
- Standard24 pagesEnglish languagee-Library read for1 day
- Amendment11 pagesEnglish languagee-Library read for1 day
This document specifies requirements, test and assessment methods, marking, labelling and packaging applicable to overfill prevention devices with closure device. The devices are usually composed by:
- sensor;
- evaluation device;
- closure device.
Overfill prevention devices intended to be used in/with underground and/or above ground, non-pressurized, static tanks designed for liquid fuels.
NOTE Liquid fuel means liquids for internal combustion engines, heating/cooling boilers and generators.
- Standard24 pagesEnglish languagee-Library read for1 day
This document deals with all significant hazards, hazardous situations and events which are relevant to machinery for supply and circulation of liquid coating material, when used as intended and under the conditions foreseen by the manufacturer, including reasonably foreseeable misuse.
See Annex A for significant hazards.
Together with this document, EN 50050 1:2013, EN 50059:2025, EN 50176:2025 or EN 50348:2010 give requirements for electrostatic machinery for supply and circulation of liquid coating material.
The specific significant risks related to the use of machinery for supply and circulation of liquid coating material with foodstuffs and pharmaceutical products are not dealt with in this document.
Interfaces to connected machinery and systems are given in Figure 1, to specify the limit of the machinery for supply and circulation of liquid coating material.
[Figure 1]
Figure 1 - Limits of the machinery
This document does not apply to:
- pressure related hazards of equipment classified as higher than category 1 of Directive 2014/68/EU Article 13;
NOTE 1 For equipment of higher category than category 1 of Directive 2014/68/EU, see EN 13445 (all parts) and EN 13480 (all parts).
- machinery for the supply of powder coating material;
- machinery for coating material recycling;
- hand-held agitators;
- agitators of more than 3 kW electrical power supply;
- offline heating systems;
- supply systems for CO2 shot-blasting machinery;
- equipment used for manufacturing of coating material;
- coating material packaging units (drums, containers, etc.).
This document is not applicable to machinery for supply and circulation of liquid coating material manufactured before the date of its publication.
- Standard50 pagesEnglish languagee-Library read for1 day
This document deals with all significant hazards, hazardous situations and hazardous events which are relevant to hand-held and automatic application equipment for coating material, when used as intended and under the conditions foreseen by the manufacturer, including reasonably foreseeable misuse.
See Annex A for significant hazards.
Together with this document, EN 50050 1:2013, EN 50050 2:2013, EN 50050 3:2013, EN 50059:2025, EN 50176:2025, EN 50177:20091, EN 50223:2015 or EN 50348:2010 give requirements for electrostatic application equipment.
The specific significant risks related to the use of application equipment with foodstuffs and pharmaceutical products are not dealt with in this document.
This document is not applicable to:
- application equipment designed for pneumatic working pressure above 15 bar;
- application equipment with rotating bell/disc designed for hydraulic working pressures above 25 bar;
- non-atomizing application equipment (e.g. extruding equipment, dispenser);
- fluidised bed powder coating machinery;
- application equipment covered by EN 50580:20125;
- supply hoses;
- airbrushes for graphic and artistic works;
- machinery for the supply and circulation of coating materials (see EN 12621:2025).
This document is not applicable to application equipment manufactured before the date of its publication.
- Standard31 pagesEnglish languagee-Library read for1 day
This part of IEC 60079 specifies the construction and testing of intrinsically safe apparatus intended for use in an explosive atmosphere, and for associated apparatus which is intended for connection to intrinsically safe circuits which enter such atmospheres.
This Type of Protection is applicable to electrical equipment in which the electrical circuits themselves are incapable of causing ignition of a surrounding explosive atmosphere. This includes electrical equipment which contains circuits that are intrinsically safe only under certain conditions, for example under battery supply with mains supply removed.
This standard is also applicable to electrical equipment or parts of electrical equipment located outside the explosive atmosphere or protected by another Type of Protection listed in IEC 60079-0, where the intrinsic safety of the electrical circuits in the explosive atmosphere may depend upon the design and construction of such electrical equipment or parts of such electrical equipment. The electrical circuits exposed to the explosive atmosphere are assessed for use in such an atmosphere by applying this standard.
This standard applies to sensors connected to intrinsically safe circuits but does not apply to the protection of catalytic elements for Group IIC or Group IIB + H2.
The requirements for intrinsically safe systems are provided in IEC 60079-25.
This standard supplements and modifies the general requirements of IEC 60079-0, except as indicated in Table 1. Where a requirement of this standard conflicts with a requirement of IEC 60079-0, the requirement of this standard takes precedence.
Unless otherwise stated, the requirements in this standard are applicable to both intrinsically safe apparatus and associated apparatus, and the generic term "apparatus" is used throughout the standard.
As this standard applies only to electrical equipment, the term "equipment" used in the standard always means “electrical equipment”.
This standard applies to apparatus for use under the atmospheric conditions of IEC 60079-0 with additional requirements for for use at lower atmospheric pressures in the range from 60 kPa (0,6 bar), up to 110 kPa (1,1 bar).
[...]
- Standard222 pagesEnglish languagee-Library read for1 day
1.1 This document specifies the electrical requirements for the design of automatic electrostatic application systems for liquid coating materials which can be ignited in an atomised state, used within a temperature range from 5 °C to 40 °C.
This document considers automatic electrostatic application systems for processing ignitable liquid coating materials, where the conductivity of the complete system is limited up to 50 nS/cm. Together with additional measures like e.g. potential separation systems, these requirements can also be applied to ignitable liquid coating materials, where the conductivity of the complete system is limited up to 2 000 μS/cm.
Ignition hazards related to the generated explosive atmosphere and the protection of persons against electric shock are considered.
1.2 This document specifies
- requirements for an interface to machinery according to EN 16985:2018,
- additional requirements for machinery covered by EN 1953:2025 and EN 12621:2025.
1.3 This document also specifies requirements for a safe operation of electrostatic application systems, including the electrical installation. The requirements consider both the processing of coating materials and the cleaning and purge processes.
1.4 This document applies to three types of spraying systems; see 5.1.1.
Spraying systems are classified as equipment of group II, category 2G (for intended use in zone 1 or zone 2) or category 3G (for intended use in zone 2).
Only electrostatic spraying systems operating with a d.c. sinusoidal ripple of not more than 10 % of the r.m.s. value are considered.
1.5 For electrostatic application systems used in food and pharmaceutical industry, additional requirements may apply.
1.6 This document does not apply to
- potential separation systems;
- selection, installation and application of other electrical and non-electrical equipment in areas with explosion hazard, see EN 60079-14:2014 and EN 16985:2018;
- quality assurance systems for electrostatic spraying equipment (see EN ISO/IEC 80079-34:2020, ZB.11).
- Standard55 pagesEnglish languagee-Library read for1 day
NEXT ACTION: UNDER BT CONSULTATION SOON (finalization EN with revised Annex Z)
HAS CONSULTANT PUB ASSESSMENT BY 2020-09-24 -- non compliant assessment received
20200325: consultant assessment missing and Annex ZZ was not circulated at FV; document blocked until such a time as this can be resolved
- Amendment10 pagesEnglish languagee-Library read for1 day
1.1 This document specifies the electrical requirements for the design of automatic electrostatic application systems for liquid coating materials which can be ignited in an atomised state, used within a temperature range from 5 °C to 40 °C. This document considers automatic electrostatic application systems for processing ignitable liquid coating materials, where the conductivity of the complete system is limited up to 50 nS/cm. Together with additional measures like e.g. potential separation systems, these requirements can also be applied to ignitable liquid coating materials, where the conductivity of the complete system is limited up to 2 000 μS/cm. Ignition hazards related to the generated explosive atmosphere and the protection of persons against electric shock are considered. 1.2 This document specifies - requirements for an interface to machinery according to EN 16985:2018, - additional requirements for machinery covered by EN 1953:2025 and EN 12621:2025. 1.3 This document also specifies requirements for a safe operation of electrostatic application systems, including the electrical installation. The requirements consider both the processing of coating materials and the cleaning and purge processes. 1.4 This document applies to three types of spraying systems; see 5.1.1. Spraying systems are classified as equipment of group II, category 2G (for intended use in zone 1 or zone 2) or category 3G (for intended use in zone 2). Only electrostatic spraying systems operating with a d.c. sinusoidal ripple of not more than 10 % of the r.m.s. value are considered. 1.5 For electrostatic application systems used in food and pharmaceutical industry, additional requirements may apply. 1.6 This document does not apply to - potential separation systems; - selection, installation and application of other electrical and non-electrical equipment in areas with explosion hazard, see EN 60079-14:2014 and EN 16985:2018; - quality assurance systems for electrostatic spraying equipment (see EN ISO/IEC 80079-34:2020, ZB.11).
- Standard55 pagesEnglish languagee-Library read for1 day
This document deals with all significant hazards, hazardous situations and events which are relevant to machinery for supply and circulation of liquid coating material, when used as intended and under the conditions foreseen by the manufacturer, including reasonably foreseeable misuse.
See Annex A for significant hazards.
Together with this document, EN 50050 1:2013, EN 50059:2025, EN 50176:2025 or EN 50348:2010 give requirements for electrostatic machinery for supply and circulation of liquid coating material.
The specific significant risks related to the use of machinery for supply and circulation of liquid coating material with foodstuffs and pharmaceutical products are not dealt with in this document.
Interfaces to connected machinery and systems are given in Figure 1, to specify the limit of the machinery for supply and circulation of liquid coating material.
[Figure 1]
Figure 1 - Limits of the machinery
This document does not apply to:
- pressure related hazards of equipment classified as higher than category 1 of Directive 2014/68/EU Article 13;
NOTE 1 For equipment of higher category than category 1 of Directive 2014/68/EU, see EN 13445 (all parts) and EN 13480 (all parts).
- machinery for the supply of powder coating material;
- machinery for coating material recycling;
- hand-held agitators;
- agitators of more than 3 kW electrical power supply;
- offline heating systems;
- supply systems for CO2 shot-blasting machinery;
- equipment used for manufacturing of coating material;
- coating material packaging units (drums, containers, etc.).
This document is not applicable to machinery for supply and circulation of liquid coating material manufactured before the date of its publication.
- Standard50 pagesEnglish languagee-Library read for1 day
This document deals with all significant hazards, hazardous situations and hazardous events which are relevant to hand-held and automatic application equipment for coating material, when used as intended and under the conditions foreseen by the manufacturer, including reasonably foreseeable misuse.
See Annex A for significant hazards.
Together with this document, EN 50050 1:2013, EN 50050 2:2013, EN 50050 3:2013, EN 50059:2025, EN 50176:2025, EN 50177:20091, EN 50223:2015 or EN 50348:2010 give requirements for electrostatic application equipment.
The specific significant risks related to the use of application equipment with foodstuffs and pharmaceutical products are not dealt with in this document.
This document is not applicable to:
- application equipment designed for pneumatic working pressure above 15 bar;
- application equipment with rotating bell/disc designed for hydraulic working pressures above 25 bar;
- non-atomizing application equipment (e.g. extruding equipment, dispenser);
- fluidised bed powder coating machinery;
- application equipment covered by EN 50580:20125;
- supply hoses;
- airbrushes for graphic and artistic works;
- machinery for the supply and circulation of coating materials (see EN 12621:2025).
This document is not applicable to application equipment manufactured before the date of its publication.
- Standard31 pagesEnglish languagee-Library read for1 day
This part of IEC 60079 specifies the construction and testing of intrinsically safe apparatus intended for use in an explosive atmosphere, and for associated apparatus which is intended for connection to intrinsically safe circuits which enter such atmospheres. This Type of Protection is applicable to electrical equipment in which the electrical circuits themselves are incapable of causing ignition of a surrounding explosive atmosphere. This includes electrical equipment which contains circuits that are intrinsically safe only under certain conditions, for example under battery supply with mains supply removed. This standard is also applicable to electrical equipment or parts of electrical equipment located outside the explosive atmosphere or protected by another Type of Protection listed in IEC 60079-0, where the intrinsic safety of the electrical circuits in the explosive atmosphere may depend upon the design and construction of such electrical equipment or parts of such electrical equipment. The electrical circuits exposed to the explosive atmosphere are assessed for use in such an atmosphere by applying this standard. This standard applies to sensors connected to intrinsically safe circuits but does not apply to the protection of catalytic elements for Group IIC or Group IIB + H2. The requirements for intrinsically safe systems are provided in IEC 60079-25. This standard supplements and modifies the general requirements of IEC 60079-0, except as indicated in Table 1. Where a requirement of this standard conflicts with a requirement of IEC 60079-0, the requirement of this standard takes precedence. Unless otherwise stated, the requirements in this standard are applicable to both intrinsically safe apparatus and associated apparatus, and the generic term "apparatus" is used throughout the standard. As this standard applies only to electrical equipment, the term "equipment" used in the standard always means “electrical equipment”. This standard applies to apparatus for use under the atmospheric conditions of IEC 60079-0 with additional requirements for for use at lower atmospheric pressures in the range from 60 kPa (0,6 bar), up to 110 kPa (1,1 bar). [...]
- Standard222 pagesEnglish languagee-Library read for1 day
This document specifies terms and definitions (vocabulary) to be used in suitable standards dealing with equipment and protective systems intended for use in potentially explosive atmospheres within the scope of Directive 2014/34/EU.
NOTE Terms and definitions avoid misunderstandings that are important in relation to the essential health and safety requirements of Directive 2014/34/EU.
- Standard38 pagesEnglish languagee-Library read for1 day
1.1 This document specifies the constructional requirements for fans constructed to Group II G (of explosion groups IIA, IIB and hydrogen) categories 1, 2 and 3, and Group II D categories 2 and 3, intended for use in explosive atmospheres.
NOTE 1 Operation conditions for the different categories of fans used in this document are defined in Clause 4.
1.3 This document specifies requirements for design, construction, testing and marking of complete fan units intended for use in potentially explosive atmospheres in air containing gas, vapour, mist and/or dusts. Such atmospheres can exist inside (the conveyed atmosphere (flammable or not)), outside, or inside and outside of the fan.
This document covers mechanical equipment, in particular fans. The “type of protection” as specified in EN ISO 80079 37:2016 is constructional safety.
1.4 This document is applicable to fans working in ambient atmospheres and with normal atmospheric conditions at the inlet, having
— absolute pressures ranging from 0,8 bar to 1,1 bar,
— and temperatures ranging from −20 °C to +60 °C,
— and maximum volume fraction of 21 % oxygen content,
— and an aerodynamic energy increase of less than 25 kJ/kg.
NOTE 1 25 kJ/kg is equivalent to 30 kPa at inlet density of 1,2 kg/m3.
This document can also be helpful for the design, construction, testing and marking of fans intended for use in atmospheres outside the validity range stated above or in cases where other material pairings need to be used. In this case, the ignition risk assessment, ignition protection provided, additional testing (if necessary), manufacturer's marking, technical documentation and instructions to the user, clearly demonstrate and indicate the equipment's suitability for the conditions the fan can encounter.
NOTE 2 Temperatures below −20 °C can be considered. Material suitability can require specific evaluation for these temperatures. With lower temperature the explosion pressure increases, which leads to increased test pressures (see A.3) and can require specific testing. Although the standard atmospheric conditions in EN ISO 80079 36:2016 give a temperature range for the atmosphere of −20 °C to +60 °C the normal ambient temperature range for the equipment is −20 °C to +40 °C unless otherwise specified and marked.
1.5 This document does not apply to:
— group I fans (fans for mining);
— explosion group IIC (other than hydrogen);
— category 1D fans;
— cooling fans or impellers on rotating electrical machines;
— cooling fans or impellers on internal combustion engines, vehicles or electric motors.
NOTE 3 Measures for category 1D fans are given in EN 1127 1:2019.
NOTE 4 Measures for explosion group IIC (other than hydrogen) are given in EN 1127 1:2019.
NOTE 5 Measures for explosion group I are given in EN ISO/IEC 80079 38:2016 and EN 1127 2:2014.
- Standard60 pagesEnglish languagee-Library read for1 day
This document specifies the requirements for equipment and protective systems for firedamp drainage at mines. It also contains requirements for the construction and monitoring of this equipment and protective systems (see EN 1127 2:2014).
This document does not apply to firedamp utilization systems beyond the utilization shut-off device.
- Standard35 pagesEnglish languagee-Library read for1 day
This document specifies the requirements for flame arresters that prevent flame transmission when explosive gas-air or vapour-air mixtures are present. It establishes uniform principles for the classification, basic construction and information for use, including the marking of flame arresters, and specifies test methods to verify the safety requirements and determine safe limits of use. This document is applicable to pressures ranging from 80 kPa to 160 kPa and temperatures ranging from -20 °C to +200 °C. This document does not apply to the following: - external safety-related measurement and control equipment that might be required to keep the operational conditions within the established safe limits; - flame arresters used for explosive mixtures of vapours and gases, which tend to self-decompose (for example, acetylene) or which are chemically unstable; - flame arresters used for carbon disulfide, due to its special properties; - flame arresters whose intended use is for mixtures other than gas-air or vapour-air mixtures (for example, higher oxygen-nitrogen ratio, chlorine as oxidant); - flame arrester test procedures for reciprocating internal combustion engines; - fast acting valves, extinguishing systems and other explosion isolating systems; - Flame arresters used in gas detectors (those being covered for example, by IEC 60079‑29‑1 and IEC 62990‑1). This edition cancels and replaces ISO 16852:2016, which has been technically revised. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to ISO 16852:2016: a) adaptation of the relevant IEC TC 31 requirements on standards; b) modification of the upper limit of the temperature range from 150 °C to 200 °C under the condition that T0 shall be not larger than 80 % of the auto ignition temperature of the gas-air-mixture; c) change of the term "explosion group" to "equipment group" due to editorial requirements in IEC/TC 31; d) clarification of the conditions and requirements for flame arresters whose intended operating conditions are outside the atmospheric conditions in 7.3.4 and 7.3.5; e) clarification of the requirements on the information for use in Clause 12 f) concerning the burn time; f) addition of a permission to the construction requirements both in 7.1 and 14.1 to substitute visual inspection by performing a flow test; g) addition of a flow chart for the evaluation of test results as Annex D
- Standard75 pagesEnglish languagee-Library read for1 day
This document specifies the requirements for flame arresters that prevent flame transmission when explosive gas-air or vapour-air mixtures are present. It establishes uniform principles for the classification, basic construction and information for use, including the marking of flame arresters, and specifies test methods to verify the safety requirements and determine safe limits of use. This document is applicable to pressures ranging from 80 kPa to 160 kPa and temperatures ranging from -20 °C to +200 °C. This document does not apply to the following: - external safety-related measurement and control equipment that might be required to keep the operational conditions within the established safe limits; - flame arresters used for explosive mixtures of vapours and gases, which tend to self-decompose (for example, acetylene) or which are chemically unstable; - flame arresters used for carbon disulfide, due to its special properties; - flame arresters whose intended use is for mixtures other than gas-air or vapour-air mixtures (for example, higher oxygen-nitrogen ratio, chlorine as oxidant); - flame arrester test procedures for reciprocating internal combustion engines; - fast acting valves, extinguishing systems and other explosion isolating systems; - Flame arresters used in gas detectors (those being covered for example, by IEC 60079‑29‑1 and IEC 62990‑1). This edition cancels and replaces ISO 16852:2016, which has been technically revised. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to ISO 16852:2016: a) adaptation of the relevant IEC TC 31 requirements on standards; b) modification of the upper limit of the temperature range from 150 °C to 200 °C under the condition that T0 shall be not larger than 80 % of the auto ignition temperature of the gas-air-mixture; c) change of the term "explosion group" to "equipment group" due to editorial requirements in IEC/TC 31; d) clarification of the conditions and requirements for flame arresters whose intended operating conditions are outside the atmospheric conditions in 7.3.4 and 7.3.5; e) clarification of the requirements on the information for use in Clause 12 f) concerning the burn time; f) addition of a permission to the construction requirements both in 7.1 and 14.1 to substitute visual inspection by performing a flow test; g) addition of a flow chart for the evaluation of test results as Annex D
- Standard75 pagesEnglish languagee-Library read for1 day
This document specifies the requirements for equipment and protective systems for firedamp drainage at mines. It also contains requirements for the construction and monitoring of this equipment and protective systems (see EN 1127 2:2014).
This document does not apply to firedamp utilization systems beyond the utilization shut-off device.
- Standard35 pagesEnglish languagee-Library read for1 day
This document specifies terms and definitions (vocabulary) to be used in suitable standards dealing with equipment and protective systems intended for use in potentially explosive atmospheres within the scope of Directive 2014/34/EU.
NOTE Terms and definitions avoid misunderstandings that are important in relation to the essential health and safety requirements of Directive 2014/34/EU.
- Standard38 pagesEnglish languagee-Library read for1 day
IEC 60079-26:2021 specifies requirements for construction, testing and marking for Ex Equipment that contains parts of the equipment with different Equipment Protection Levels (EPLs) and a separation element. This equipment is mounted across a boundary where different EPLs are required, for example between different gas hazardous areas, dust hazardous areas or gas hazardous areas adjacent to dust hazardous areas.
Separation elements are considered for both electrical and non-electrical equipment. If mechanical energy can be transformed into a potential ignition source, additionally an ignition hazard assessment in accordance with ISO 80079-36 is performed and appropriate measures are undertaken.
This document also specifies requirements for the combination of two Types of Protection, each with EPL Gb, to achieve EPL Ga.
This document supplements and modifies the general requirements of IEC 60079-0. Where a requirement of this document conflicts with a requirement of IEC 60079-0, the requirement of this document takes precedence. This fourth edition cancels and replaces the third edition and constitutes a technical revision.
Please see the IEC 60079-26:2020 foreword for a description of the main changes with respect to the previous edition.
- Standard26 pagesEnglish languagee-Library read for1 day
This document is applicable to self-propelled and pedestrian propelled manual and semi-manual industrial trucks as defined in ISO 5053-1:2020 including their load handling devices and attachments (hereafter referred to as trucks) intended for use in potentially explosive atmospheres.
NOTE 1 Attachments mounted on the load carrier or on fork arms which are removable by the user are not considered to be a part of the truck.
This document specifies supplementary technical requirements for the prevention of the ignition of an explosive atmosphere of flammable gases, vapours, mists or dusts by industrial trucks of equipment group II and equipment category 2G, 3G, 2D or 3D.
NOTE 2 The relationship between an equipment category (hereafter referred to as category) and the corresponding zone (area classification) is shown in informative Annex B.
This document does not apply to:
- trucks of equipment group I;
- trucks of equipment group II, equipment category 1;
- trucks intended for use in potentially explosive atmospheres with hybrid mixtures;
- protective systems.
This document does not apply to trucks intended for use in potentially explosive atmospheres of carbon disulfide (CS2), carbon monoxide (CO) and/or ethylene oxide (C2H4O) due to the special properties of these gases.
Technical requirements relating to lithium-ion batteries and fuel cells as energy sources are not given in this document due to their specific hazards.
- Standard54 pagesEnglish languagee-Library read for1 day
1.1 This document specifies the constructional requirements for fans constructed to Group II G (of explosion groups IIA, IIB and hydrogen) categories 1, 2 and 3, and Group II D categories 2 and 3, intended for use in explosive atmospheres.
NOTE 1 Operation conditions for the different categories of fans used in this document are defined in Clause 4.
1.3 This document specifies requirements for design, construction, testing and marking of complete fan units intended for use in potentially explosive atmospheres in air containing gas, vapour, mist and/or dusts. Such atmospheres can exist inside (the conveyed atmosphere (flammable or not)), outside, or inside and outside of the fan.
This document covers mechanical equipment, in particular fans. The “type of protection” as specified in EN ISO 80079 37:2016 is constructional safety.
1.4 This document is applicable to fans working in ambient atmospheres and with normal atmospheric conditions at the inlet, having
— absolute pressures ranging from 0,8 bar to 1,1 bar,
— and temperatures ranging from −20 °C to +60 °C,
— and maximum volume fraction of 21 % oxygen content,
— and an aerodynamic energy increase of less than 25 kJ/kg.
NOTE 1 25 kJ/kg is equivalent to 30 kPa at inlet density of 1,2 kg/m3.
This document can also be helpful for the design, construction, testing and marking of fans intended for use in atmospheres outside the validity range stated above or in cases where other material pairings need to be used. In this case, the ignition risk assessment, ignition protection provided, additional testing (if necessary), manufacturer's marking, technical documentation and instructions to the user, clearly demonstrate and indicate the equipment's suitability for the conditions the fan can encounter.
NOTE 2 Temperatures below −20 °C can be considered. Material suitability can require specific evaluation for these temperatures. With lower temperature the explosion pressure increases, which leads to increased test pressures (see A.3) and can require specific testing. Although the standard atmospheric conditions in EN ISO 80079 36:2016 give a temperature range for the atmosphere of −20 °C to +60 °C the normal ambient temperature range for the equipment is −20 °C to +40 °C unless otherwise specified and marked.
1.5 This document does not apply to:
— group I fans (fans for mining);
— explosion group IIC (other than hydrogen);
— category 1D fans;
— cooling fans or impellers on rotating electrical machines;
— cooling fans or impellers on internal combustion engines, vehicles or electric motors.
NOTE 3 Measures for category 1D fans are given in EN 1127 1:2019.
NOTE 4 Measures for explosion group IIC (other than hydrogen) are given in EN 1127 1:2019.
NOTE 5 Measures for explosion group I are given in EN ISO/IEC 80079 38:2016 and EN 1127 2:2014.
- Standard60 pagesEnglish languagee-Library read for1 day
This document is applicable to self-propelled and pedestrian propelled manual and semi-manual industrial trucks as defined in ISO 5053-1:2020 including their load handling devices and attachments (hereafter referred to as trucks) intended for use in potentially explosive atmospheres.
NOTE 1 Attachments mounted on the load carrier or on fork arms which are removable by the user are not considered to be a part of the truck.
This document specifies supplementary technical requirements for the prevention of the ignition of an explosive atmosphere of flammable gases, vapours, mists or dusts by industrial trucks of equipment group II and equipment category 2G, 3G, 2D or 3D.
NOTE 2 The relationship between an equipment category (hereafter referred to as category) and the corresponding zone (area classification) is shown in informative Annex B.
This document does not apply to:
- trucks of equipment group I;
- trucks of equipment group II, equipment category 1;
- trucks intended for use in potentially explosive atmospheres with hybrid mixtures;
- protective systems.
This document does not apply to trucks intended for use in potentially explosive atmospheres of carbon disulfide (CS2), carbon monoxide (CO) and/or ethylene oxide (C2H4O) due to the special properties of these gases.
Technical requirements relating to lithium-ion batteries and fuel cells as energy sources are not given in this document due to their specific hazards.
- Standard54 pagesEnglish languagee-Library read for1 day
This document specifies general requirements for design, testing and performance, and describes the test methods that apply to portable, transportable and fixed equipment for the measurement of the oxygen concentration in gas mixtures indicating up to 25 % (v/v).
- Amendment5 pagesEnglish languagee-Library read for1 day
This document specifies general requirements for design, testing and performance, and describes the test methods that apply to portable, transportable and fixed equipment for the measurement of the oxygen concentration in gas mixtures indicating up to 25 % (v/v).
- Amendment5 pagesEnglish languagee-Library read for1 day
IEC Corrected version
- Corrigendum4 pagesEnglish languagee-Library read for1 day
IEC Corrected version
- Corrigendum4 pagesEnglish languagee-Library read for1 day
This document specifies requirements for design, construction, testing and marking of hand-held, portable and transportable vacuum cleaners, including their accessories, constructed to Group II, categories 2G or 3G (of explosion groups IIA, IIB, IIB plus hydrogen), and to Group II, categories 2D or 3D (of explosion groups IIIA, IIIB and IIIC), intended for the collection of combustible or non-combustible dusts and flammable or non-flammable liquids in potentially explosive atmospheres. A potentially explosive atmosphere could be generated by the equipment during its intended use.
NOTE 1 The accumulation of 1 mm or more of combustible dust on surfaces in a working area can create an explosive atmosphere (see reference to 1/32 in. of Depth of Dust Accumulation for Guidance for Area Electrical Classification in NFPA 654, 2017 Edition).
This document applies to equipment driven by electric power and by pneumatic power.
This document gives guidelines for dealing with significant hazards, hazardous situations and/or events relevant to vacuum cleaners when they are used as intended and under conditions of misuse which are reasonably foreseeable by the manufacturer.
Typical applications for the concerned equipment are:
- collection of dust produced by machinery at the point of generation;
- general housekeeping around machinery and of working areas; and/or
- collection of spills;
- cleaning of equipment during maintenance operations; and/or
- collection of specific waste.
For the collection of dust in the presence of flammable liquids or vapours, a specific risk assessment is performed if this is part of the vacuum cleaners intended conditions of use and additional precautions beyond what is described in this document can be required.
NOTE 2 The passage of dust through a vacuum cleaner will generate high levels of electrostatic charge which, in most situations, will be a potential source of ignition to a flammable gas or vapour atmosphere.
For the collection of low-conductivity flammable liquids, a specific risk assessment is performed if this is part of the vacuum cleaners intended conditions of use and additional precautions beyond what is described in this document can be required.
NOTE 3 The resulting liquid velocities are likely to be in excess of the limits required to maintain electrostatic charge generation at a non-hazardous level according to CLC/TR 60079 32 1:2018.
This document does not apply to equipment used to collect toxic dusts where there is a health risk if dust passes through the filter elements. This document does not apply to the collection of dusts which have explosive and unstable properties (UN transport class 1, class 4.1 and class 5.2).
NOTE 4 Hazards related to the use of vacuum cleaners for the collection of hazardous dusts are the subject of other standards.
This document applies to vacuum cleaners with an internal dirty air volume of maximum 250 l.
NOTE 5 250 l is the volume above which it is recognized a vacuum cleaner might not be considered as transportable by an operator, and above which additional explosion protections can be required.
The present version of the document does not apply to battery operated equipment.
NOTE 6 Battery operated equipment might be part of the scope of this document in a subsequent version.
This document does not apply to vacuum trucks.
This document applies to vacuum cleaners of canister and back-pack types. This document does not apply to upright vacuum cleaners.
This document does not apply to motorized cleaning head accessories.
NOTE 7 This document does not apply to household appliances which are the subject of other standards.
This document does not apply to applications where the substances are conveyed into a separate receiving container.
This document does not apply to equipment intended for use in underground parts of mines as well as those parts of surface installations of such mines endangered by firedamp and/or combustible dust.
..
- Standard98 pagesEnglish languagee-Library read for1 day
This document covers the safety requirements for aero derivative and industrial gas turbine prime mover applications using liquid or gaseous fuels and the safety related control and detection systems and essential auxiliaries for all types of open cycles (simple, combined, regenerative, reheat, etc.) used in onshore and offshore applications including floating production platforms.
This document applies to mechanical, electrical, and pressure equipment components and systems necessary for the functionality of the prime mover. For example, but not limited to, a core gas turbine auxiliary gearbox, an output transmission gear box, combustion system, air filtration, gas turbine controls, oil systems, and fuel system. This document also covers integration of safety risks within the overall installation, e.g. exhaust purging or drainage.
This document details the anticipated significant hazards associated with aero derivative and industrial gas turbine prime movers and specifies the appropriate preventative measures and processes for reduction or elimination of these hazards. This document addresses the risks of injury or death to humans and risks to the environment. Equipment damage without risk to humans or the environment is not covered.
The overall objective of this document is to ensure that equipment is designed, constructed, operated and maintained throughout its life in accordance with ISO 12100:2010.
This document approaches gas turbine safety from an international perspective based on the content of existing, recognized ISO and IEC standards to the greatest extent possible. Where no ISO or IEC standard exists, other codes or standards (such as EN, NFPA, etc.) have been included.
Minimum functional safety levels cannot be addressed in this document, as minimum functional safety levels are both application and site specific.
This document excludes the following items;
— exhaust-system structural design;
— driven equipment;
— micro turbines as covered by ISO 19372:2015;
— gas turbines used primarily for direct and indirect propulsion;
— gas turbines used for mobile applications;
— special heat source applications;
— gas turbines in research and development programs;
— compressed-air energy storage plants.
Where appropriate, this document can be used to give general guidance in such applications.
This document is not applicable to machinery or safety components manufactured before the date of its publication.
- Standard103 pagesEnglish languagee-Library read for1 day
This document covers the safety requirements for aero derivative and industrial gas turbine prime mover applications using liquid or gaseous fuels and the safety related control and detection systems and essential auxiliaries for all types of open cycles (simple, combined, regenerative, reheat, etc.) used in onshore and offshore applications including floating production platforms.
This document applies to mechanical, electrical, and pressure equipment components and systems necessary for the functionality of the prime mover. For example, but not limited to, a core gas turbine auxiliary gearbox, an output transmission gear box, combustion system, air filtration, gas turbine controls, oil systems, and fuel system. This document also covers integration of safety risks within the overall installation, e.g. exhaust purging or drainage.
This document details the anticipated significant hazards associated with aero derivative and industrial gas turbine prime movers and specifies the appropriate preventative measures and processes for reduction or elimination of these hazards. This document addresses the risks of injury or death to humans and risks to the environment. Equipment damage without risk to humans or the environment is not covered.
The overall objective of this document is to ensure that equipment is designed, constructed, operated and maintained throughout its life in accordance with ISO 12100:2010.
This document approaches gas turbine safety from an international perspective based on the content of existing, recognized ISO and IEC standards to the greatest extent possible. Where no ISO or IEC standard exists, other codes or standards (such as EN, NFPA, etc.) have been included.
Minimum functional safety levels cannot be addressed in this document, as minimum functional safety levels are both application and site specific.
This document excludes the following items;
— exhaust-system structural design;
— driven equipment;
— micro turbines as covered by ISO 19372:2015;
— gas turbines used primarily for direct and indirect propulsion;
— gas turbines used for mobile applications;
— special heat source applications;
— gas turbines in research and development programs;
— compressed-air energy storage plants.
Where appropriate, this document can be used to give general guidance in such applications.
This document is not applicable to machinery or safety components manufactured before the date of its publication.
- Standard103 pagesEnglish languagee-Library read for1 day
IEC 60079-25:2020 contains the specific requirements for design, construction and assessment of intrinsically safe systems, Type of Protection “i”, intended for use, as a whole or in part, in locations in which the use of Group I, II or III Ex Equipment is required.
This document supplements and modifies the general requirements of IEC 60079-0 and the intrinsic safety standard IEC 60079-11. Where a requirement of this standard conflicts with a requirement of IEC 60079-0 or IEC 60079-11, the requirement of this standard takes precedence.
The installation requirements of Group II or Group III systems designed in accordance with this standard are specified in IEC 60079-14.
This third edition cancels and replaces the second edition published in 2010 and constitutes a technical revision.
- Standard64 pagesEnglish languagee-Library read for1 day
NEXT ACTION: TB ACTION BY 2020-01-31 (prep doc for BT meeting - Feb2021)
BT CONSULTATION FAILED (addition of Annex ZZ) ON 2020-11-10
HAS CONSULTANT ASSESSMENT BY 2020-09-24 (PUB assessment) - Compliant assessment on 2020-09-22
2020-04-8 mah: Consultant assessment at FV missing, Annex ZZ did not go to FV.
- Amendment8 pagesEnglish languagee-Library read for1 day
EN 60079-29-1 specifies general requirements for construction, testing and performance, and describes the test methods that apply to portable, transportable and fixed equipment for the detection and measurement of flammable gas or vapour concentrations with air. The equipment, or parts thereof, is intended for use in explosive atmospheres and in mines susceptible to firedamp.
EN 60079-29-1 is applicable to flammable gas detection equipment with a measuring range up to any volume fraction as declared by the manufacturer, and which is intended to provide an indication, alarm or other output function; the purpose of which is to indicate a potential explosion hazard and in some cases, to initiate automatic or manual protective action(s).
- Amendment5 pagesEnglish languagee-Library read for1 day
This document specifies a test method to determine the explosion limits of gases, vapours and their mixtures, mixed with a gaseous oxidizer or an oxidizer/inert gas mixture at pressures from 0,10 MPa to 10 MPa and for temperatures up to 400 °C.
- Standard19 pagesEnglish languagee-Library read for1 day
IEC 60079-25:2020 contains the specific requirements for design, construction and assessment of intrinsically safe systems, Type of Protection “i”, intended for use, as a whole or in part, in locations in which the use of Group I, II or III Ex Equipment is required. This document supplements and modifies the general requirements of IEC 60079-0 and the intrinsic safety standard IEC 60079-11. Where a requirement of this standard conflicts with a requirement of IEC 60079-0 or IEC 60079-11, the requirement of this standard takes precedence. The installation requirements of Group II or Group III systems designed in accordance with this standard are specified in IEC 60079-14. This third edition cancels and replaces the second edition published in 2010 and constitutes a technical revision.
- Standard64 pagesEnglish languagee-Library read for1 day
IEC 60079-31:2022 is available as IEC 60079-31:2022 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60079-31:2022 is applicable to equipment protected by enclosure and surface temperature limitation for use in explosive dust atmospheres. It specifies requirements for design, construction and testing of Ex Equipment and Ex Components. This document supplements and modifies the general requirements of IEC 60079-0. Where a requirement of this document conflicts with a requirement of IEC 60079-0, the requirement of this document takes precedence. This document does not apply to dusts of explosives, which do not require atmospheric oxygen for combustion, or to pyrophoric substances. This document does not apply to Ex Equipment or Ex Components intended for use in underground parts of mines as well as those parts of surface installations of such mines endangered by firedamp and/or combustible dust. This document does not take account of any risk due to an emission of flammable or toxic gas from the dust. This third edition cancels and replaces the second edition published in 2013. This edition constitutes a technical revision. Main significant changes from the previous edition are: 1) Document has been restructured from edition 2 2) Fault current rating of interrupting contacts in clauses 4.3.1 and 4.4.1, major change type C1 3) Cells and batteries in clauses 4.3.5.1 and 4.4.5.1, major change type C2 4) Overload or malfunction condition for the determination of temperature class for "tb" converter fed rotating electric machines, major change type C3 5) Additional requirements for entry devices with dust ignition protection by enclosure "t", major change type C4 Information about the background of ‘Major Technical Changes’ C1 – Ex Equipment having Level of Protection "ta" shall be rated for connection to a circuit with a prospective short circuit current of not greater than 1.5 kA. For Ex Equipment having Level of Protection "tb" or "tc" which is intended for mains connection and intended to interrupt fault current above 10kA, the equipment shall have a rated maximum short circuit withstand current, be tested according to 6.1.1.1, and be marked according to Clause 7. C2 – For Ex Equipment having Level of Protection "ta" which contains a cell or battery, only a sealed cell or battery shall be used. For Ex Equipment having Level of Protection "tb" and "tc" where there are sparking contacts or hot surfaces, and which contains a cell or battery, only a sealed cell or battery shall be used. C3 – Table 2 now includes malfunction conditions for temperature class determination of Level of Protection "tb" converter-fed electric machines. C4 – Annex A added for entry devices with Type of Protection "t" including cable transit devices.
- Standard25 pagesEnglish languagee-Library read for1 day
This document specifies general requirements for design, testing and performance, and describes the test methods that apply to portable, transportable and fixed equipment for the measurement of the oxygen concentration in gas mixtures indicating up to 25 % (v/v). The equipment, or parts thereof, may be intended for use in explosive atmospheres (see 4.1) and in mines susceptible to firedamp. This document applies to equipment intended for monitoring oxygen deficiency and enrichment. EXAMPLE Monitoring oxygen deficiency and/or enrichment includes: - protection of human health and safety in potentially oxygen deficient atmospheres; - fire protection by monitoring areas with reduced oxygen concentration; - fire protection by monitoring oxygen concentrations exceeding that of normal ambient air. This document also applies to equipment with an oxygen measuring function for explosion protection in the case of monitoring inertisation. NOTE 1 Inertisation is an explosion protection technique where a potentially explosive atmosphere is purged with inert gas. NOTE 2 Commonly used oxygen sensors in commercial equipment for industrial application are: - electrochemical sensors (aqueous and solid electrolytes); - paramagnetic sensors; - zirconium dioxide sensors; - tunable diode laser absorption spectroscopy sensors (TDLAS). This document is applicable to equipment intended to measure reliably the oxygen concentration, to provide an indication, alarm or other output function, the purpose of which is to give a warning of a potential hazard and, in some cases, to initiate automatic or manual protective action(s), whenever the level exceeds or falls below an alarm set point. This document is applicable to equipment, including integral sampling systems of aspirated equipment, intended to be used for commercial, industrial and non-residential safety applications. This document does not apply to external sampling systems, or to equipment of laboratory or scientific type, or to medical equipment, or to equipment used only for process monitoring and/or control purposes. For equipment used for sensing the presence of multiple gases, this document applies only to the measurement of oxygen. This document is also applicable to equipment using optical principles (e.g. TDLAS), where the optical transmitter and receiver or the optical transceiver (i.e. combined transmitter and receiver) and a suitable reflector are not located in a common enclosure. However, in this case it will be necessary to modify the test conditions described in Clause 5.3 and to introduce supplementary tests to Clause 5.4 of this document. Such supplementary tests will include alignment, beam block fault, long range operation. Guidance to appropriate modification of the test conditions and supplementary tests can be taken from EN 60079 29 4. Modifications of the test conditions as well as modified and supplementary tests are expected to be agreed between the manufacturer and test laboratory and identified and described in the test report.
- Standard37 pagesEnglish languagee-Library read for1 day
This document specifies requirements for design, construction, testing and marking of hand-held, portable and transportable vacuum cleaners, including their accessories, constructed to Group II, categories 2G or 3G (of explosion groups IIA, IIB, IIB plus hydrogen), and to Group II, categories 2D or 3D (of explosion groups IIIA, IIIB and IIIC), intended for the collection of combustible or non-combustible dusts and flammable or non-flammable liquids in potentially explosive atmospheres. A potentially explosive atmosphere could be generated by the equipment during its intended use.
NOTE 1 The accumulation of 1 mm or more of combustible dust on surfaces in a working area can create an explosive atmosphere (see reference to 1/32 in. of Depth of Dust Accumulation for Guidance for Area Electrical Classification in NFPA 654, 2017 Edition).
This document applies to equipment driven by electric power and by pneumatic power.
This document gives guidelines for dealing with significant hazards, hazardous situations and/or events relevant to vacuum cleaners when they are used as intended and under conditions of misuse which are reasonably foreseeable by the manufacturer.
Typical applications for the concerned equipment are:
- collection of dust produced by machinery at the point of generation;
- general housekeeping around machinery and of working areas; and/or
- collection of spills;
- cleaning of equipment during maintenance operations; and/or
- collection of specific waste.
For the collection of dust in the presence of flammable liquids or vapours, a specific risk assessment is performed if this is part of the vacuum cleaners intended conditions of use and additional precautions beyond what is described in this document can be required.
NOTE 2 The passage of dust through a vacuum cleaner will generate high levels of electrostatic charge which, in most situations, will be a potential source of ignition to a flammable gas or vapour atmosphere.
For the collection of low-conductivity flammable liquids, a specific risk assessment is performed if this is part of the vacuum cleaners intended conditions of use and additional precautions beyond what is described in this document can be required.
NOTE 3 The resulting liquid velocities are likely to be in excess of the limits required to maintain electrostatic charge generation at a non-hazardous level according to CLC/TR 60079 32 1:2018.
This document does not apply to equipment used to collect toxic dusts where there is a health risk if dust passes through the filter elements. This document does not apply to the collection of dusts which have explosive and unstable properties (UN transport class 1, class 4.1 and class 5.2).
NOTE 4 Hazards related to the use of vacuum cleaners for the collection of hazardous dusts are the subject of other standards.
This document applies to vacuum cleaners with an internal dirty air volume of maximum 250 l.
NOTE 5 250 l is the volume above which it is recognized a vacuum cleaner might not be considered as transportable by an operator, and above which additional explosion protections can be required.
The present version of the document does not apply to battery operated equipment.
NOTE 6 Battery operated equipment might be part of the scope of this document in a subsequent version.
This document does not apply to vacuum trucks.
This document applies to vacuum cleaners of canister and back-pack types. This document does not apply to upright vacuum cleaners.
This document does not apply to motorized cleaning head accessories.
NOTE 7 This document does not apply to household appliances which are the subject of other standards.
This document does not apply to applications where the substances are conveyed into a separate receiving container.
This document does not apply to equipment intended for use in underground parts of mines as well as those parts of surface installations of such mines endangered by firedamp and/or combustible dust.
..
- Standard98 pagesEnglish languagee-Library read for1 day
This document specifies a test method to determine the explosion limits of gases, vapours and their mixtures, mixed with a gaseous oxidizer or an oxidizer/inert gas mixture at pressures from 0,10 MPa to 10 MPa and for temperatures up to 400 °C.
- Standard19 pagesEnglish languagee-Library read for1 day
This document specifies a test method that is designed to measure the explosion pressure and the maximum explosion pressure, the rate of explosion pressure rise and the maximum rate of explosion pressure rise of a quiescent flammable gas/air/inert mixture in closed volume at ambient temperature and pressure. In this document, the term “gas” includes vapours but not mists. Detonation and decomposition phenomena are not considered in this document.
The pressures and rates of pressure rise measured by the procedures specified in this document are not applicable to flameproof enclosures, i.e. enclosures intended to withstand an internal explosion and not to transmit it to an external explosive atmosphere, or any other closed volume where the internal geometry can result in pressure piling. Even in an enclosure of relatively simple geometry the disposition of the internal components can lead to rates of pressure rise significantly higher than those measured using this document. This document does not apply to the design and testing of flameproof enclosures in conformity with EN ISO 80079-37 (for non-electrical equipment) and EN 60079-1 (for electrical equipment).
- Standard41 pagesEnglish languagee-Library read for1 day
This document specifies the minimum design, construction, test requirements and the critical dimensions for filling nozzles for the dispensing of automotive Liquefied Petroleum Gas (LPG) to vehicles of categories M and N, as defined in Regulation (EU) 2018/858 [2], that are fitted with the Euro filling unit (light duty or heavy duty).
- Standard26 pagesEnglish languagee-Library read for1 day
NEXT ACTION: TB ACTION BY 2020-01-31 (prep doc for BT meeting - Feb2021)
BT CONSULTATION FAILED (addition of Annex ZZ) ON 2020-11-10
HAS CONSULTANT ASSESSMENT BY 2020-09-24 (PUB assessment) - Compliant assessment on 2020-09-22
2020-04-8 mah: Consultant assessment at FV missing, Annex ZZ did not go to FV.
- Amendment8 pagesEnglish languagee-Library read for1 day
EN 60079-29-1 specifies general requirements for construction, testing and performance, and describes the test methods that apply to portable, transportable and fixed equipment for the detection and measurement of flammable gas or vapour concentrations with air. The equipment, or parts thereof, is intended for use in explosive atmospheres and in mines susceptible to firedamp. EN 60079-29-1 is applicable to flammable gas detection equipment with a measuring range up to any volume fraction as declared by the manufacturer, and which is intended to provide an indication, alarm or other output function; the purpose of which is to indicate a potential explosion hazard and in some cases, to initiate automatic or manual protective action(s).
- Amendment5 pagesEnglish languagee-Library read for1 day
ISO/IEC 80079-20-1:2017 is published as a dual log standard and provides guidance on classification of gases and vapours. It describes a test method intended for the measurement of the maximum experimental safe gaps (MESG) for gas-air mixtures or vapour-air mixtures under normal conditions of temperature and pressure (20 °C, 101,3 kPa) so as to permit the selection of an appropriate group of equipment. This document also describes a test method intended for use in the determination of the auto-ignition temperature (AIT) of a vapour-air mixture or gas-air mixture at atmospheric pressure, so as to permit the selection of an appropriate temperature class of equipment. Values of chemical properties of materials are provided to assist in the selection of equipment to be used in hazardous areas. Further data may be added as the results of validated tests become available. The materials and the characteristics included in a table (see Annex B) have been selected with particular reference to the use of equipment in hazardous areas. The data in this document have been taken from a number of references which are given in the bibliography. These methods for determining the MESG or the AIT may also be used for gas-air-inert mixtures or vapour-air-inert mixtures. However, data on air-inert mixtures are not tabulated.
Keywords: classification of gases and vapours, measurement of the maximum experimental safe gaps (MESG)
- Standard93 pagesEnglish languagee-Library read for1 day
NEW!IEC 60079-15:2017 is available as IEC 60079-15:2017 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60079-15:2017 specifies requirements for the construction, testing and marking for Group II electrical equipment with type of protection “n” which includes; sealed devices “nC”, hermetically sealed devices “nC”, non-incendive components “nC” and restricted breathing enclosures “nR” intended for use in explosive gas atmospheres. This part of IEC 60079 applies to electrical equipment where the rated input voltage does not exceed 15 kV r.m.s. AC or DC including where the internal working voltages of the Ex product exceeds 15 kV, for example starters for HID luminaires. This part of IEC 60079 supplements and modifies the general requirements of IEC 60079-0, except as indicated in Table 1 (Clause 1). Where a requirement of this part of IEC 60079 conflicts with a requirement of IEC 60079-0, the requirement of this part of IEC 60079 takes precedence. This fifth edition cancels and replaces the fourth edition, published in 2010, and constitutes a technical revision. Refer to the Forward of the document for a complete listing of the technical changes between edition 5.0 and the previous edition of the document. Keywords: Group II electrical equipment with type of protection “n”
- Standard36 pagesEnglish languagee-Library read for1 day
This document specifies a test method that is designed to measure the explosion pressure and the maximum explosion pressure, the rate of explosion pressure rise and the maximum rate of explosion pressure rise of a quiescent flammable gas/air/inert mixture in closed volume at ambient temperature and pressure. In this document, the term “gas” includes vapours but not mists. Detonation and decomposition phenomena are not considered in this document.
The pressures and rates of pressure rise measured by the procedures specified in this document are not applicable to flameproof enclosures, i.e. enclosures intended to withstand an internal explosion and not to transmit it to an external explosive atmosphere, or any other closed volume where the internal geometry can result in pressure piling. Even in an enclosure of relatively simple geometry the disposition of the internal components can lead to rates of pressure rise significantly higher than those measured using this document. This document does not apply to the design and testing of flameproof enclosures in conformity with EN ISO 80079-37 (for non-electrical equipment) and EN 60079-1 (for electrical equipment).
- Standard41 pagesEnglish languagee-Library read for1 day
This document specifies methods for the identification and assessment of hazardous situations leading to explosion and the design and construction measures appropriate for the required safety. This is achieved by:
- risk assessment;
- risk reduction.
The safety of equipment, protective systems and components can be achieved by eliminating hazards and/or limiting the risk, i.e. by:
a) appropriate design (without using safeguarding);
b) safeguarding;
c) information for use;
d) any other preventive measures.
Measures in accordance with a) (prevention) and b) (protection) against explosions are dealt with in Clause 6, measures according to c) against explosions are dealt with in Clause 7. Measures in accordance with d) are not specified in this document. They are dealt with in EN ISO 12100:2010, Clause 6.
The preventive and protective measures described in this document will not provide the required level of safety unless the equipment, protective systems and components are operated within their intended use and are installed and maintained according to the relevant codes of practice or requirements.
This document specifies general design and construction methods to help designers and manufacturers in achieving explosion safety in the design of equipment, protective systems and components.
This document is applicable to any equipment, protective systems and components intended to be used in potentially explosive atmospheres, under atmospheric conditions. These atmospheres can arise from flammable/combustible substances processed, used or released by the equipment, protective systems and components or from materials in the vicinity of the equipment, protective systems and components and/or from the materials of construction of the equipment, protective systems and components.
This document is applicable to equipment, protective systems and components at all stages of its use.
This document is only applicable to equipment group II which is intended for use in other places than underground parts of mines and those parts of surface installations of such mines endangered by firedamp and/or combustible dust.
This document is not applicable to:
1) medical devices intended for use in a medical environment;
2) equipment, protective systems and components where the explosion hazard results exclusively from the presence of explosive substances or unstable chemical substances;
3) equipment, protective systems and components where the explosion can occur by reaction of substances with other oxidizers than atmospheric oxygen or by other hazardous reactions or by other than atmospheric conditions;
4) equipment intended for use in domestic and non-commercial environments where potentially explosive atmospheres may only rarely be created, solely as a result of the accidental leakage of fuel gas;
5) personal protective equipment covered by Regulation (EU) 2016/425;
6) seagoing vessels and mobile offshore units together with equipment on board such vessels or units;
7) means of transport, i.e. vehicles and their trailers intended solely for transporting passengers by air or by road, rail or water networks, as well as means of transport insofar as such means are designed for transporting goods by air, by public road or rail networks or by water; vehicles intended for use in a potentially explosive atmosphere shall not be excluded;
8) the design and construction of systems containing desired, controlled combustion processes, unless they can act as ignition sources in potentially explosive atmospheres.
- Standard47 pagesEnglish languagee-Library read for1 day
Frequently Asked Questions
A European Standardization Mandate is a formal request from the European Commission to the European Standardization Organizations (CEN, CENELEC, and ETSI) to develop European standards (ENs) in support of EU legislation and policies. Mandates are issued under Regulation (EU) No 1025/2012 and help ensure that products and services meet the essential requirements set out in EU directives and regulations.
M/BC/CEN/92/46 is a European Standardization Mandate titled "Standardization mandate assigned to CEN/CENELEC concerning equipment and protective systems intended for use in potentially explosive atmospheres". Standardization mandate assigned to CEN/CENELEC concerning equipment and protective systems intended for use in potentially explosive atmospheres There are 363 standards developed under this mandate.
Standards developed in response to a mandate and cited in the Official Journal of the European Union become "harmonized standards". Products manufactured in compliance with harmonized standards benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation, facilitating CE marking and market access across the European Economic Area.