M/404 - Electro Magnetic compatibility
Standardisation Mandate to CEN, CENELEC and ETSI for harmonized standard according to the Electro Magnetic Compatibility (EMC) Directive 2004/108/EC
General Information
This part of IEC 61557 specifies requirements for power metering and monitoring devices
(PMD) that measure and monitor the electrical quantities within electrical distribution systems,
and optionally other external signals. These requirements also define the performance in
single- and three-phase AC or DC systems having rated voltages up to 1 000 V AC or up to
1 500 V DC.
These devices are fixed or portable. They are intended to be used indoors and/or outdoors.
Power metering and monitoring devices (PMD), as defined in this document, give additional
safety information, which aids the verification of the installation and enhances the
performance of the distribution systems.
The power metering and monitoring devices (PMD) for electrical parameters described in this
document are used for general industrial and commercial applications.
This document does not address functional safety and cyber security aspects.
This document is not applicable for:
– electricity metering equipment that complies with IEC 62053-21, IEC 62053-22,
IEC 62053-23 and IEC 62053-24. Nevertheless, uncertainties defined in this document for
active and reactive energy measurement are derived from those defined in IEC 62053 (all
parts);
– the measurement and monitoring of electrical parameters defined in IEC 61557-2 to
IEC 61557-9 and IEC 61557-13 or in IEC 62020;
– power quality instrument (PQI) according IEC 62586 (all parts);
– devices covered by IEC 60051 (all parts) (direct acting analogue electrical measuring
instrument).
NOTE 1 Generally such types of devices are used in the following applications or for the following general needs:
– energy management inside the installation, such as facilitating the implementation of documents such as
ISO 50001 and IEC 60364-8-1;
– monitoring and/or measurement of electrical parameters;
– measurement and/or monitoring of the quality of energy inside commercial/industrial installations.
NOTE 2 A measuring and monitoring device of electrical parameters usually consists of several functional
modules. All or some of the functional modules are combined in one device. Examples of functional modules are:
– measurement and monitoring of several electrical parameters simultaneously;
– energy measurement and/or monitoring, as well as sometimes compliance with aspects of building regulations;
– alarms functions;
– demand side quality (current and voltage harmonics, over/under voltages, voltage dips and swells, etc.).
NOTE 3 PMD are historically called power meter, power monitor, power monitor device, power energy monitoring
device, power analyser, multifunction meter, measuring multifunction equipment, energy meters.
NOTE 4 Metering, measuring and monitoring applications are explained in Annex A.
- Standard106 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 61557-12:2018 is available as IEC 61557-12:2018 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 61557-12:2018 specifies requirements for power metering and monitoring devices (PMD) that measure and monitor the electrical quantities within electrical distribution systems, and optionally other external signals. These requirements also define the performance in single- and three-phase AC or DC systems having rated voltages up to 1 000 V AC or up to 1 500 V DC. These devices are fixed or portable. They are intended to be used indoors and/or outdoors. Power metering and monitoring devices (PMD), as defined in this document, give additional safety information, which aids the verification of the installation and enhances the performance of the distribution systems. The power metering and monitoring devices (PMD) for electrical parameters described in this document are used for general industrial and commercial applications. This document does not address functional safety and cyber security aspects. This document is not applicable for: – electricity metering equipment that complies with IEC 62053-21, IEC 62053-22, IEC 62053-23 and IEC 62053-24. Nevertheless, uncertainties defined in this document for active and reactive energy measurement are derived from those defined in IEC 62053 (all parts); – the measurement and monitoring of electrical parameters defined in IEC 61557-2 to IEC 61557-9 and IEC 61557-13 or in IEC 62020; – power quality instrument (PQI) according IEC 62586 (all parts); – devices covered by IEC 60051 (all parts) (direct acting analogue electrical measuring instrument). IEC 61557-12:2018 cancels and replaces the first edition published in 2007. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) PMD-A has been withdrawn due the fact these devices are now mainly covered by the IEC 62586 series of standards. b) Three categories of PMD have been created with a list of minimum required functions for each category. c) Added a new Annex A explaining the different applications linked to the relevant standards and devices, and another new Annex C about the power factor conventions.
- Standard106 pagesEnglish languagesale 10% offe-Library read for1 day
This document applies to residual current monitors for household and similar purposes,
having rated operational voltages and a rated voltage of the monitored circuit not exceeding
440 V AC and rated currents not exceeding 125 A.
NOTE 1 The standard for residual current monitors having rated operational voltages and a rated voltage of the
monitored circuit exceeding 440 V AC is in preparation, as IEC 62020-2.
RCMs are intended to monitor the residual current of the installation and to give a warning if
the residual current between a live part and an exposed conductive part or earth exceeds a
predetermined level.
RCMs covered by this document are not intended to be used as protective devices.
RCMs detect residual currents circulating in an AC circuit (e.g. residual alternating current,
residual pulsating direct current, residual smooth direct current), whether suddenly applied or
slowly rising.
NOTE 2 RCMs for DC systems are under consideration.
This document applies to monitors performing simultaneously the functions of detection of the
residual current, of comparison of the value of this current with the residual operating current
of the device and providing the specified warning signal(s) when the residual current exceeds
this value.
RCMs supplied by internal batteries are not covered by this document.
The requirements of this document apply for standard conditions (see 7.1). Additional
requirements can be necessary for RCMs used in locations having severe environmental
conditions.
RCMs are intended for use in an environment with pollution degree 2 and overvoltage
category III. For an environment with a higher pollution degree, enclosures giving the
appropriate degree of protection are used.
RCMs in compliance with this document are suitable for use in TN, TT, and IT systems.
This document does not cover Insulation Monitoring Devices (IMDs), which are covered by the
scope of IEC 61557-8.
NOTE 3 An RCM is distinguished from an IMD in that it is passive in its monitoring function and only responds to
an unbalanced fault current in the installation being monitored. An IMD is active in its monitoring and measuring
functions in that it can measure the balanced and unbalanced insulation resistance or impedance in the installation
(see IEC 61557-8).
- Standard119 pagesEnglish languagesale 10% offe-Library read for1 day
- Draft107 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 62053-24:2020 applies only to static var-hour meters of accuracy classes 0,5S, 1S, 1, 2 and 3 for the measurement of alternating current electrical reactive energy in 50 Hz or 60 Hz networks and it applies to their type tests only.
This document uses a conventional definition of reactive energy where the reactive power and energy is calculated from the fundamental frequency components of the currents and voltages only.
This document applies to electricity metering equipment designed to:
• measure and control electrical energy on electrical networks (mains) with voltage up to 1 000 V AC;
• have all functional elements, including add-on modules, enclosed in, or forming a single meter case with exception of indicating displays;
• operate with integrated or detached indicating displays, or without an indicating display;
• be installed in a specified matching socket or rack;
• optionally, provide additional functions other than those for measurement of electrical energy.
Meters designed for operation with low power instrument transformers (LPITs as defined in the IEC 61869 series) may be considered as compliant with this document only if such meters and their LPITs are tested together and meet the requirements for directly connected meters.
This document does not apply to:
• meters for which the voltage line-to-neutral derived from nominal voltages exceeds 1 000 V AC;
• meters intended for connection with low power instrument transformers (LPITs as defined in the IEC 61869 series) when tested without such transformers;
• metering systems comprising multiple devices (except LPITs) physically remote from one another;
• portable meters;
• meters used in rolling stock, vehicles, ships and airplanes;
• laboratory and meter test equipment;
• reference standard meters;
• data interfaces to the register of the meter;
• matching sockets or racks used for installation of electricity metering equipment;
• any additional functions provided in electrical energy meters.
This document does not cover measures for the detection and prevention of fraudulent attempts to compromise a meter’s performance (tampering).
This second edition cancels and replaces the first edition published in 2014 and its amendment 1:2016. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition: see Annex E
- Standard25 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 62052-11:2020 (E) specifies requirements and associated tests, with their appropriate conditions for type testing of AC and DC electricity meters. This document details functional, mechanical, electrical and marking requirements, test methods, and test conditions, including immunity to external influences covering electromagnetic and climatic environments.
This document applies to electricity metering equipment designed to:
• measure and control electrical energy on electrical networks (mains) with voltage up to 1 000 V AC, or 1 500 V DC;
• have all functional elements, including add-on modules, enclosed in, or forming a single meter case with exception of indicating displays;
• operate with integrated displays (electromechanical or static meters);
• operate with detached indicating displays, or without an indicating display (static meters only);
• be installed in a specified matching sockets or racks;
• optionally, provide additional functions other than those for measurement of electrical energy.
Meters designed for operation with Low Power Instrument Transformers (LPITs as defined in the IEC 61869 series) may be tested for compliance with this document and the relevant IEC 62053 series documents only if such meters and their LPITs are tested together as directly connected meters.
This document is also applicable to auxiliary input and output circuits, operation indicators, and test outputs of equipment for electrical energy measurement.
This document also covers the common aspects of accuracy testing such as reference conditions, repeatability and measurement of uncertainty.
This document does not apply to:
• meters for which the voltage line-to-neutral derived from nominal voltages exceeds 1 000 V AC, or 1 500 V DC;
• meters intended for connection with low power instrument transformers (LPITs as defined in the IEC 61869 series of standards) when tested without such transformers;
• metering systems comprising multiple devices (except of LPITs) physically remote from one another;
• portable meters;
• meters used in rolling stock, vehicles, ships and airplanes;
• laboratory and meter test equipment;
• reference standard meters;
• data interfaces to the register of the meter;
• matching sockets or racks used for installation of electricity metering equipment;
• any additional functions provided in electrical energy meters.
This document does not cover measures for the detection and prevention of fraudulent attempts to compromise a meter’s performance (tampering).
This second edition cancels and replaces the first edition published in 2003, and its amendment 1:2016. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) Removed all meter safety requirements; the meter safety requirements are covered in IEC 62052-31:2015;
b) Included requirements for meter power consumption and voltage requirements from IEC 62053-61; IEC 62053-61 is withdrawn;
c) Included requirements for meter symbols from IEC 62053-52; IEC 62053-52 is withdrawn;
d) Included requirements for meter pulse output devices from IEC 62053-31; IEC 62053-31 is withdrawn;
e) Added new requirements and tests including: meters with detached indicating displays, and meters without indicating displays, meter sealing provisions; measurement uncertainty and repeatability; time-keeping accuracy; type tes
- Standard125 pagesEnglish languagesale 10% offe-Library read for1 day
2021-02-25: TC Off confirmed: can be published without link to legislation as agreed by BT D162/C064, link removed
2019-12-02: NEXT ACTION: TC to prepare ZZ
2019-12-02: TC decision to further process document
2019-01-28 - Assessment is missing.
- Amendment13 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 62053-23:2020 applies only to static var-hour meters of accuracy classes 2 and 3 for the measurement of alternating current electrical reactive energy in 50 Hz or 60 Hz networks and it applies to their type tests only.
For practical reasons, this document is based on a conventional definition of reactive energy for sinusoidal currents and voltages containing the fundamental frequency only.
This document applies to electricity metering equipment designed to:
• measure and control electrical energy on electrical networks (mains) with voltage up to 1 000 V AC;
• have all functional elements, including add-on modules, enclosed in, or forming a single meter case with exception of indicating displays;
• operate with integrated or detached indicating displays, or without an indicating display;
• be installed in a specified matching socket or rack;
• optionally, provide additional functions other than those for measurement of electrical energy.
Meters designed for operation with low power instrument transformers (LPITs as defined in the IEC 61869 series) may be considered as compliant with this document only if such meters and their LPITs are tested together and meet the requirements for directly connected meters.
This document does not apply to:
• meters for which the voltage line-to-neutral derived from nominal voltages exceeds 1 000 V AC;
• meters intended for connection with low power instrument transformers (LPITs as defined in the IEC 61869 series) when tested without such transformers;
• metering systems comprising multiple devices (except LPITs) physically remote from one another;
• portable meters;
• meters used in rolling stock, vehicles, ships and airplanes;
• laboratory and meter test equipment;
• reference standard meters;
• data interfaces to the register of the meter;
• matching sockets or racks used for installation of electricity metering equipment;
• any additional functions provided in electrical energy meters.
This document does not cover measures for the detection and prevention of fraudulent attempts to compromise a meter’s performance (tampering).
This second edition cancels and replaces the first edition published in 2003 and its amendment 1:2016. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) Removed all meter safety requirements; the meter safety requirements are covered in IEC 62052-31:2015.
b) Replaced Ib with In; Ib is no longer used when referencing directly connected meters.
c) Moved the descriptions of all general requirements and test methods from IEC 62053-21: 2003, IEC 62053-22: 2003, IEC 62053-23: 2003, IEC 62053-24: 2003 to IEC 62052-11:2020; IEC 62053-21:2020, IEC 62053-22:2020, IEC 62053-23:2020, IEC 62053-24:2020 contain only accuracy class specific requirements.
d) Added new requirements and tests concerning:
1) measurement uncertainty and repeatability (7.3, 7.8);
2) influence of fast load current variations (9.4.12);
3) immunity to conducted differential current disturbances in the 2 kHz to 150 kHz frequency range (9.3.8).
e) Meters designed for operation with low power instrument transformers (LPITs) may be tested for compliance with this document as directly connected meters.
The reactive energy accuracy classes 2 and 3 defined in IEC 62053-23 have also been added to IEC 62053-24. The TC13
- Standard20 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 62053-21:2020 applies only to static watt-hour meters of accuracy classes 0,5, 1 and 2 for the measurement of alternating current electrical active energy in 50 Hz or 60 Hz networks and it applies to their type tests only.
This document applies to electricity metering equipment designed to:
• measure and control electrical energy on electrical networks (mains) with voltage up to 1 000 V AC;
• have all functional elements, including add-on modules, enclosed in, or forming a single meter case with exception of indicating displays;
• operate with integrated or detached indicating displays, or without an indicating display;
• be installed in a specified matching socket or rack;
• optionally, provide additional functions other than those for measurement of electrical energy.
Meters designed for operation with low power instrument transformers (LPITs as defined in the IEC 61869 series) may be tested for compliance with this document only if such meters and their LPITs are tested together and meet the requirements for directly connected meters.
This document does not apply to:
• meters for which the voltage line-to-neutral derived from nominal voltages exceeds 1 000 V AC;
• meters intended for connection with low power instrument transformers (LPITs as defined in the IEC 61869 series) when tested without such transformers;
• metering systems comprising multiple devices (except LPITs) physically remote from one another;
• portable meters;
• meters used in rolling stock, vehicles, ships and airplanes;
• laboratory and meter test equipment;
• reference standard meters;
• data interfaces to the register of the meter;
• matching sockets or racks used for installation of electricity metering equipment;
• any additional functions provided in electrical energy meters.
This document does not cover measures for the detection and prevention of fraudulent attempts to compromise a meter’s performance (tampering).
This second edition cancels and replaces the first edition published in 2003 and its amendment 1:2016. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) Removed all meter safety requirements; the meter safety requirements are covered in IEC 62052-31: 2015.
b) Replaced Ib with In; Ib is no longer used when referencing directly connected meters.
c) Moved the descriptions of all general requirements and test methods from IEC 62053-21: 2003, IEC 62053-22: 2003, IEC 62053-23: 2003, IEC 62053-24: 2003 to IEC 62052-11:2020; IEC 62053-21:2020, IEC 62053-22:2020, IEC 62053-23:2020, IEC 62053-24:2020 contain only accuracy class specific requirements.
d) Added new requirements and tests concerning:
1) measurement uncertainty and repeatability (7.3, 7.8);
2) influence of fast load current variations (9.4.12);
3) immunity to conducted differential current disturbances in the 2 kHz to 150 kHz frequency range (9.3.8).
e) Meters designed for operation with low power instrument transformers (LPITs) may be tested for compliance with this document as directly connected meters.
- Standard20 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 62053-22:2020 applies only to transformer operated static watt-hour meters of accuracy classes 0,1 S, 0,2 S and 0,5 S for the measurement of alternating current electrical active energy in 50 Hz or 60 Hz networks and it applies to their type tests only.
This document applies to electricity metering equipment designed to:
• measure and control electrical energy on electrical networks (mains) with voltage up to 1 000 V AC;
• have all functional elements, including add-on modules, enclosed in, or forming a single meter case with exception of indicating displays;
• operate with integrated or detached indicating displays, or without an indicating display;
• be installed in a specified matching socket or rack;
• optionally, provide additional functions other than those for measurement of electrical energy.
This document does not apply to:
• meters for which the voltage line-to-neutral derived from nominal voltages exceeds 1 000 V AC;
• meters intended for connection with low power instrument transformers (LPITs as defined in the IEC 61869 series) when tested without such transformers;
• metering systems comprising multiple devices physically remote from one another.
• portable meters;
• meters used in rolling stock, vehicles, ships and airplanes;
• laboratory and meter test equipment;
• reference standard meters;
• data interfaces to the register of the meter;
• matching sockets or racks used for installation of electricity metering equipment;
• any additional functions provided in electrical energy meters.
This document does not cover measures for the detection and prevention of fraudulent attempts to compromise a meter’s performance (tampering)
This second edition cancels and replaces the first edition published in 2003 and its amendment 1: 2016. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) Removed all meter safety requirements; the meter safety requirements are covered in IEC 62052-31: 2015.
b) Moved the descriptions of all general requirements and test methods from IEC 62053-21: 2003, IEC 62053-22: 2003, IEC 62053-23: 2003, IEC 62053-24: 2003 to IEC 62052-11:2020; IEC 62053-21:2020, IEC 62053-22:2020, IEC 62053-23:2020, IEC 62053-24:2020 contain only accuracy class specific requirements.
c) Added new requirements and tests concerning:
1) active energy meters of accuracy class 0,1S;
2) measurement uncertainty and repeatability (7.3, 7.8);
3) influence of fast load current variations (9.4.12);
4) immunity to conducted differential current disturbances in the 2 kHz to 150 kHz frequency range (9.3.8)
- Standard20 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 61000-6-3:2020 is a generic EMC emission standard applicable only if no relevant dedicated product or product family EMC emission standard has been published. This part of IEC 61000 for emission requirements applies to electrical and electronic equipment intended for use at residential (see 3.1.14) locations. This part of IEC 61000 also applies to electrical and electronic equipment intended for use at other locations that do not fall within the scope of IEC 61000-6-8 or IEC 61000-6-4. The intention is that all equipment used in the residential, commercial and light-industrial environments are covered by IEC 61000-6-3 or IEC 61000-6-8. If there is any doubt the requirements in IEC 61000-6-3 apply. The conducted and radiated emission requirements in the frequency range up to 400 GHz are considered essential and have been selected to provide an adequate level of protection of radio reception in the defined electromagnetic environment. Not all disturbance phenomena have been included for testing purposes but only those considered relevant for the equipment intended to operate within the locations included within this document. The emission requirements in this document are not intended to be applicable to the intentional transmissions and their harmonics from a radio transmitter as defined by the ITU. This third edition cancels and replaces the second edition published in 2006 and its Amendment 1:2010. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) alternative method for measuring conducted emissions on DC ports;
b) limits and requirements applicable only to equipment intended to be used in residential locations;
c) more stringent limits for DC power ports.
NOTE 1 Safety considerations are not covered by this document.
NOTE 2 In special cases, situations will arise where the levels specified in this document will not offer adequate protection; for example where a sensitive receiver is used in close proximity to an equipment. In these instances, special mitigation measures can be employed. NOTE 3 Disturbances generated in fault conditions of equipment are not covered by this document.
NOTE 4 As the requirements in this document are more stringent or equivalent to those requirements in IEC 61000-6-4 and IEC 61000-6-8, equipment fulfilling the requirements of this document comply with the requirements of IEC 61000-6-4 and IEC 61000-6-8.
- Standard30 pagesEnglish languagesale 10% offe-Library read for1 day
EC 60730-2-8:2018 applies to electrically operated water valves for use in, on or in association with equipment for household and similar use, including heating, air-conditioning and similar applications. The equipment can use electricity, gas, oil, solid fuel, solar thermal energy, etc., or a combination thereof. This document is applicable to electrically operated water valves for building automation within the scope of ISO 16484. This document also applies to automatic electrically operated water valves for equipment that can be used by the public, such as equipment intended to be used in shops, offices, hospitals, farms and commercial and industrial applications. This document does not apply to electrically operated water valves intended exclusively for industrial process applications unless explicitly mentioned in the relevant equipment standard. This document applies to electrically operated water valves powered by primary or secondary batteries, requirements for which are contained within the standard, including Annex V. This document does not cover the prevention of contamination of drinking water as a result of contact with materials. This document applies to the inherent safety, to the operating values, operating times and operating sequences where such are associated with equipment safety, and to the testing of automatic electrical control devices used in, on or in association with, household and similar equipment. This document contains requirements for electrical features of water valves and requirements for mechanical features of valves that affect their intended operation. This document is also applicable to electrically operated water valves for appliances within the scope of the IEC 60335 series of standards. This document does not apply to:
- electrically operated water valves of nominal connection size above DN 50;
- electrically operated water valves for admissible nominal pressure rating above 1,6 MPa;
- food dispensers;
- detergent dispensers;
- steam valves;
- electrically operated water valves designed exclusively for industrial applications. This document applies to electrically operated water valves, responsive to or controlling such characteristics as temperature, pressure, passage of time, humidity, light, electrostatic effects, flow, or liquid level, current, voltage, acceleration, or combinations thereof. This document also applies to actuators and to valve bodies which are designed to be fitted to each other. This document applies to individual valves, valves utilized as part of a system and valves mechanically integral with multi-functional controls having non-electrical outputs. This document applies to AC or DC powered electrically operated water valves with a rated voltage not exceeding 690 V AC or 600 V DC. This document does not take into account the response value of an automatic action of a valve, if such a response value is dependent upon the method of mounting the valve in the equipment. Where a response value is of significant purpose for the protection of the user, or surroundings, the value defined in the appropriate equipment standard or as determined by the manufacturer shall apply.
- Standard51 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 62020-1:2020 applies to residual current monitors for household and similar purposes, having rated operational voltages and a rated voltage of the monitored circuit not exceeding 440 V AC and rated currents not exceeding 125 A. This first edition cancels and replaces IEC 62020:1998 and IEC 62020:1998/AMD1:2003. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: – definition of Type F and Type B RCM; – marking of Type F and Type B RCM; – introduction of a new subclause, REF _Ref521411992 \r \h \* MERGEFORMAT 8.20 08D0C9EA79F9BACE118C8200AA004BA90B02000000080000000E0000005F005200650066003500320031003400310031003900390032000000 ; – modification of REF _Ref521412027 \r \h \* MERGEFORMAT 9.7 08D0C9EA79F9BACE118C8200AA004BA90B02000000080000000E0000005F005200650066003500320031003400310032003000320037000000 ; – update of REF _Ref521412044 \r \h \* MERGEFORMAT 9.9 08D0C9EA79F9BACE118C8200AA004BA90B02000000080000000E0000005F005200650066003500320031003400310032003000340034000000 ; – modification of REF _Ref521412054 \r \h \* MERGEFORMAT 9.14 08D0C9EA79F9BACE118C8200AA004BA90B02000000080000000E0000005F005200650066003500320031003400310032003000350034000000 ; – modification of
- Standard119 pagesEnglish languagesale 10% offe-Library read for1 day
- Draft107 pagesEnglish languagesale 10% offe-Library read for1 day
2021-02-25: TC Off confirmed: can be published without link to legislation as agreed by BT D162/C064, link removed
2019-12-02: NEXT ACTION: TC to prepare ZZ
2019-12-02: TC decision to further process document
2019-01-28 - Assessment is missing.
- Amendment13 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 62053-22:2020 applies only to transformer operated static watt-hour meters of accuracy classes 0,1 S, 0,2 S and 0,5 S for the measurement of alternating current electrical active energy in 50 Hz or 60 Hz networks and it applies to their type tests only. This document applies to electricity metering equipment designed to: • measure and control electrical energy on electrical networks (mains) with voltage up to 1 000 V AC; • have all functional elements, including add-on modules, enclosed in, or forming a single meter case with exception of indicating displays; • operate with integrated or detached indicating displays, or without an indicating display; • be installed in a specified matching socket or rack; • optionally, provide additional functions other than those for measurement of electrical energy. This document does not apply to: • meters for which the voltage line-to-neutral derived from nominal voltages exceeds 1 000 V AC; • meters intended for connection with low power instrument transformers (LPITs as defined in the IEC 61869 series) when tested without such transformers; • metering systems comprising multiple devices physically remote from one another. • portable meters; • meters used in rolling stock, vehicles, ships and airplanes; • laboratory and meter test equipment; • reference standard meters; • data interfaces to the register of the meter; • matching sockets or racks used for installation of electricity metering equipment; • any additional functions provided in electrical energy meters. This document does not cover measures for the detection and prevention of fraudulent attempts to compromise a meter’s performance (tampering) This second edition cancels and replaces the first edition published in 2003 and its amendment 1: 2016. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) Removed all meter safety requirements; the meter safety requirements are covered in IEC 62052-31: 2015. b) Moved the descriptions of all general requirements and test methods from IEC 62053-21: 2003, IEC 62053-22: 2003, IEC 62053-23: 2003, IEC 62053-24: 2003 to IEC 62052-11:2020; IEC 62053-21:2020, IEC 62053-22:2020, IEC 62053-23:2020, IEC 62053-24:2020 contain only accuracy class specific requirements. c) Added new requirements and tests concerning: 1) active energy meters of accuracy class 0,1S; 2) measurement uncertainty and repeatability (7.3, 7.8); 3) influence of fast load current variations (9.4.12); 4) immunity to conducted differential current disturbances in the 2 kHz to 150 kHz frequency range (9.3.8)
- Standard20 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 62052-11:2020 (E) specifies requirements and associated tests, with their appropriate conditions for type testing of AC and DC electricity meters. This document details functional, mechanical, electrical and marking requirements, test methods, and test conditions, including immunity to external influences covering electromagnetic and climatic environments. This document applies to electricity metering equipment designed to: • measure and control electrical energy on electrical networks (mains) with voltage up to 1 000 V AC, or 1 500 V DC; • have all functional elements, including add-on modules, enclosed in, or forming a single meter case with exception of indicating displays; • operate with integrated displays (electromechanical or static meters); • operate with detached indicating displays, or without an indicating display (static meters only); • be installed in a specified matching sockets or racks; • optionally, provide additional functions other than those for measurement of electrical energy. Meters designed for operation with Low Power Instrument Transformers (LPITs as defined in the IEC 61869 series) may be tested for compliance with this document and the relevant IEC 62053 series documents only if such meters and their LPITs are tested together as directly connected meters. This document is also applicable to auxiliary input and output circuits, operation indicators, and test outputs of equipment for electrical energy measurement. This document also covers the common aspects of accuracy testing such as reference conditions, repeatability and measurement of uncertainty. This document does not apply to: • meters for which the voltage line-to-neutral derived from nominal voltages exceeds 1 000 V AC, or 1 500 V DC; • meters intended for connection with low power instrument transformers (LPITs as defined in the IEC 61869 series of standards) when tested without such transformers; • metering systems comprising multiple devices (except of LPITs) physically remote from one another; • portable meters; • meters used in rolling stock, vehicles, ships and airplanes; • laboratory and meter test equipment; • reference standard meters; • data interfaces to the register of the meter; • matching sockets or racks used for installation of electricity metering equipment; • any additional functions provided in electrical energy meters. This document does not cover measures for the detection and prevention of fraudulent attempts to compromise a meter’s performance (tampering). This second edition cancels and replaces the first edition published in 2003, and its amendment 1:2016. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) Removed all meter safety requirements; the meter safety requirements are covered in IEC 62052-31:2015; b) Included requirements for meter power consumption and voltage requirements from IEC 62053-61; IEC 62053-61 is withdrawn; c) Included requirements for meter symbols from IEC 62053-52; IEC 62053-52 is withdrawn; d) Included requirements for meter pulse output devices from IEC 62053-31; IEC 62053-31 is withdrawn; e) Added new requirements and tests including: meters with detached indicating displays, and meters without indicating displays, meter sealing provisions; measurement uncertainty and repeatability; time-keeping accuracy; type tes
- Standard125 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 62053-23:2020 applies only to static var-hour meters of accuracy classes 2 and 3 for the measurement of alternating current electrical reactive energy in 50 Hz or 60 Hz networks and it applies to their type tests only. For practical reasons, this document is based on a conventional definition of reactive energy for sinusoidal currents and voltages containing the fundamental frequency only. This document applies to electricity metering equipment designed to: • measure and control electrical energy on electrical networks (mains) with voltage up to 1 000 V AC; • have all functional elements, including add-on modules, enclosed in, or forming a single meter case with exception of indicating displays; • operate with integrated or detached indicating displays, or without an indicating display; • be installed in a specified matching socket or rack; • optionally, provide additional functions other than those for measurement of electrical energy. Meters designed for operation with low power instrument transformers (LPITs as defined in the IEC 61869 series) may be considered as compliant with this document only if such meters and their LPITs are tested together and meet the requirements for directly connected meters. This document does not apply to: • meters for which the voltage line-to-neutral derived from nominal voltages exceeds 1 000 V AC; • meters intended for connection with low power instrument transformers (LPITs as defined in the IEC 61869 series) when tested without such transformers; • metering systems comprising multiple devices (except LPITs) physically remote from one another; • portable meters; • meters used in rolling stock, vehicles, ships and airplanes; • laboratory and meter test equipment; • reference standard meters; • data interfaces to the register of the meter; • matching sockets or racks used for installation of electricity metering equipment; • any additional functions provided in electrical energy meters. This document does not cover measures for the detection and prevention of fraudulent attempts to compromise a meter’s performance (tampering). This second edition cancels and replaces the first edition published in 2003 and its amendment 1:2016. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) Removed all meter safety requirements; the meter safety requirements are covered in IEC 62052-31:2015. b) Replaced Ib with In; Ib is no longer used when referencing directly connected meters. c) Moved the descriptions of all general requirements and test methods from IEC 62053-21: 2003, IEC 62053-22: 2003, IEC 62053-23: 2003, IEC 62053-24: 2003 to IEC 62052-11:2020; IEC 62053-21:2020, IEC 62053-22:2020, IEC 62053-23:2020, IEC 62053-24:2020 contain only accuracy class specific requirements. d) Added new requirements and tests concerning: 1) measurement uncertainty and repeatability (7.3, 7.8); 2) influence of fast load current variations (9.4.12); 3) immunity to conducted differential current disturbances in the 2 kHz to 150 kHz frequency range (9.3.8). e) Meters designed for operation with low power instrument transformers (LPITs) may be tested for compliance with this document as directly connected meters. The reactive energy accuracy classes 2 and 3 defined in IEC 62053-23 have also been added to IEC 62053-24. The TC13
- Standard20 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 62053-24:2020 applies only to static var-hour meters of accuracy classes 0,5S, 1S, 1, 2 and 3 for the measurement of alternating current electrical reactive energy in 50 Hz or 60 Hz networks and it applies to their type tests only. This document uses a conventional definition of reactive energy where the reactive power and energy is calculated from the fundamental frequency components of the currents and voltages only. This document applies to electricity metering equipment designed to: • measure and control electrical energy on electrical networks (mains) with voltage up to 1 000 V AC; • have all functional elements, including add-on modules, enclosed in, or forming a single meter case with exception of indicating displays; • operate with integrated or detached indicating displays, or without an indicating display; • be installed in a specified matching socket or rack; • optionally, provide additional functions other than those for measurement of electrical energy. Meters designed for operation with low power instrument transformers (LPITs as defined in the IEC 61869 series) may be considered as compliant with this document only if such meters and their LPITs are tested together and meet the requirements for directly connected meters. This document does not apply to: • meters for which the voltage line-to-neutral derived from nominal voltages exceeds 1 000 V AC; • meters intended for connection with low power instrument transformers (LPITs as defined in the IEC 61869 series) when tested without such transformers; • metering systems comprising multiple devices (except LPITs) physically remote from one another; • portable meters; • meters used in rolling stock, vehicles, ships and airplanes; • laboratory and meter test equipment; • reference standard meters; • data interfaces to the register of the meter; • matching sockets or racks used for installation of electricity metering equipment; • any additional functions provided in electrical energy meters. This document does not cover measures for the detection and prevention of fraudulent attempts to compromise a meter’s performance (tampering). This second edition cancels and replaces the first edition published in 2014 and its amendment 1:2016. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: see Annex E
- Standard25 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 62053-21:2020 applies only to static watt-hour meters of accuracy classes 0,5, 1 and 2 for the measurement of alternating current electrical active energy in 50 Hz or 60 Hz networks and it applies to their type tests only. This document applies to electricity metering equipment designed to: • measure and control electrical energy on electrical networks (mains) with voltage up to 1 000 V AC; • have all functional elements, including add-on modules, enclosed in, or forming a single meter case with exception of indicating displays; • operate with integrated or detached indicating displays, or without an indicating display; • be installed in a specified matching socket or rack; • optionally, provide additional functions other than those for measurement of electrical energy. Meters designed for operation with low power instrument transformers (LPITs as defined in the IEC 61869 series) may be tested for compliance with this document only if such meters and their LPITs are tested together and meet the requirements for directly connected meters. This document does not apply to: • meters for which the voltage line-to-neutral derived from nominal voltages exceeds 1 000 V AC; • meters intended for connection with low power instrument transformers (LPITs as defined in the IEC 61869 series) when tested without such transformers; • metering systems comprising multiple devices (except LPITs) physically remote from one another; • portable meters; • meters used in rolling stock, vehicles, ships and airplanes; • laboratory and meter test equipment; • reference standard meters; • data interfaces to the register of the meter; • matching sockets or racks used for installation of electricity metering equipment; • any additional functions provided in electrical energy meters. This document does not cover measures for the detection and prevention of fraudulent attempts to compromise a meter’s performance (tampering). This second edition cancels and replaces the first edition published in 2003 and its amendment 1:2016. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) Removed all meter safety requirements; the meter safety requirements are covered in IEC 62052-31: 2015. b) Replaced Ib with In; Ib is no longer used when referencing directly connected meters. c) Moved the descriptions of all general requirements and test methods from IEC 62053-21: 2003, IEC 62053-22: 2003, IEC 62053-23: 2003, IEC 62053-24: 2003 to IEC 62052-11:2020; IEC 62053-21:2020, IEC 62053-22:2020, IEC 62053-23:2020, IEC 62053-24:2020 contain only accuracy class specific requirements. d) Added new requirements and tests concerning: 1) measurement uncertainty and repeatability (7.3, 7.8); 2) influence of fast load current variations (9.4.12); 3) immunity to conducted differential current disturbances in the 2 kHz to 150 kHz frequency range (9.3.8). e) Meters designed for operation with low power instrument transformers (LPITs) may be tested for compliance with this document as directly connected meters.
- Standard20 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 61000-6-3:2020 is a generic EMC emission standard applicable only if no relevant dedicated product or product family EMC emission standard has been published. This part of IEC 61000 for emission requirements applies to electrical and electronic equipment intended for use at residential (see 3.1.14) locations. This part of IEC 61000 also applies to electrical and electronic equipment intended for use at other locations that do not fall within the scope of IEC 61000-6-8 or IEC 61000-6-4. The intention is that all equipment used in the residential, commercial and light-industrial environments are covered by IEC 61000-6-3 or IEC 61000-6-8. If there is any doubt the requirements in IEC 61000-6-3 apply. The conducted and radiated emission requirements in the frequency range up to 400 GHz are considered essential and have been selected to provide an adequate level of protection of radio reception in the defined electromagnetic environment. Not all disturbance phenomena have been included for testing purposes but only those considered relevant for the equipment intended to operate within the locations included within this document. The emission requirements in this document are not intended to be applicable to the intentional transmissions and their harmonics from a radio transmitter as defined by the ITU. This third edition cancels and replaces the second edition published in 2006 and its Amendment 1:2010. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) alternative method for measuring conducted emissions on DC ports; b) limits and requirements applicable only to equipment intended to be used in residential locations; c) more stringent limits for DC power ports. NOTE 1 Safety considerations are not covered by this document. NOTE 2 In special cases, situations will arise where the levels specified in this document will not offer adequate protection; for example where a sensitive receiver is used in close proximity to an equipment. In these instances, special mitigation measures can be employed. NOTE 3 Disturbances generated in fault conditions of equipment are not covered by this document. NOTE 4 As the requirements in this document are more stringent or equivalent to those requirements in IEC 61000-6-4 and IEC 61000-6-8, equipment fulfilling the requirements of this document comply with the requirements of IEC 61000-6-4 and IEC 61000-6-8.
- Standard30 pagesEnglish languagesale 10% offe-Library read for1 day
This document applies, when required by the relevant product standard, to low-voltage
switchgear and controlgear hereinafter referred to as "equipment" or “device” and intended to
be connected to circuits, the rated voltage of which does not exceed 1 000 V AC or
1 500 V DC.
This document states the general rules and common safety requirements for low-voltage
switchgear and controlgear, including:
− definitions;
− characteristics;
− information supplied with the equipment;
− normal service, mounting and transport conditions, decommissioning and dismantling;
− constructional and performance requirements;
− verification of characteristics and performance;
− energy efficiency aspects (see Annex V);
− environmental aspects.
This document does not apply to:
− low-voltage switchgear and controlgear assemblies which are dealt with in IEC 61439
series, as applicable;
− terminals for connection of aluminium conductors;
NOTE Terminals for aluminium conductors are under consideration for the next revision.
− use within explosive atmospheres (see IEC 60079 series);
− software and firmware requirements for functional safety application (see IEC 61508-3);
− cyber security aspects (see IEC 62443 series).
- Standard292 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard309 pagesFrench languagesale 10% offe-Library read for1 day
- Standard – translation298 pagesSlovenian languagesale 10% offe-Library read for1 day
IEC 60947-1:2020 applies, when required by the relevant product standard, to low-voltage switchgear and controlgear hereinafter referred to as "equipment" or “device” and intended to be connected to circuits, the rated voltage of which does not exceed 1 000 V AC or 1 500 V DC. This document states the general rules and common safety requirements for low-voltage switchgear and controlgear, including: - definitions; - characteristics; - information supplied with the equipment; - normal service, mounting and transport conditions, decommissioning and dismantling; - constructional and performance requirements; - verification of characteristics and performance; - energy efficiency aspects (see Annex V); - environmental aspects. This sixth edition cancels and replaces the fifth edition published in 2007, Amendment 1:2010 and Amendment 2:2014. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: – DC values testing improvement; – update of EMC tests; – Annex B deletion; – update of requirements for environmental tests (Table Q.1); – improvement of Annex R (new examples); – deletion of digital input Type 2, and introduction of Type 3 in Annex S; – example for materials declaration (Annex W); – new Annex X (co-ordination between short-circuit protective devices associated in the same circuit) created.
- Standard292 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard309 pagesFrench languagesale 10% offe-Library read for1 day
- Standard – translation298 pagesSlovenian languagesale 10% offe-Library read for1 day
NEW!IEC 60730-2-8:2018 is available as IEC 60730-2-8:2018 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60730-2-8:2018 applies to electrically operated water valves for use in, on or in association with equipment for household and similar use, including heating, air-conditioning and similar applications. The equipment can use electricity, gas, oil, solid fuel, solar thermal energy, etc., or a combination thereof. This document is applicable to electrically operated water valves for building automation within the scope of ISO 16484. This document also applies to automatic electrically operated water valves for equipment that can be used by the public, such as equipment intended to be used in shops, offices, hospitals, farms and commercial and industrial applications. This document does not apply to electrically operated water valves intended exclusively for industrial process applications unless explicitly mentioned in the relevant equipment standard. This document applies to electrically operated water valves powered by primary or secondary batteries, requirements for which are contained within the standard, including Annex V. This document does not cover the prevention of contamination of drinking water as a result of contact with materials. This document applies to the inherent safety, to the operating values, operating times and operating sequences where such are associated with equipment safety, and to the testing of automatic electrical control devices used in, on or in association with, household and similar equipment. This document contains requirements for electrical features of water valves and requirements for mechanical features of valves that affect their intended operation. This document is also applicable to electrically operated water valves for appliances within the scope of the IEC 60335 series of standards. This document does not apply to: - electrically operated water valves of nominal connection size above DN 50; - electrically operated water valves for admissible nominal pressure rating above 1,6 MPa; - food dispensers; - detergent dispensers; - steam valves; - electrically operated water valves designed exclusively for industrial applications. This document applies to electrically operated water valves, responsive to or controlling such characteristics as temperature, pressure, passage of time, humidity, light, electrostatic effects, flow, or liquid level, current, voltage, acceleration, or combinations thereof. This document also applies to actuators and to valve bodies which are designed to be fitted to each other. This document applies to individual valves, valves utilized as part of a system and valves mechanically integral with multi-functional controls having non-electrical outputs. This document applies to AC or DC powered electrically operated water valves with a rated voltage not exceeding 690 V AC or 600 V DC. This document does not take into account the response value of an automatic action of a valve, if such a response value is dependent upon the method of mounting the valve in the equipment. Where a response value is of significant purpose for the protection of the user, or surroundings, the value defined in the appropriate equipment standard or as determined by the manufacturer shall apply. This document applies also to electrically operated water valves incorporating electronic devices, requirements for which are contained in
- Standard51 pagesEnglish languagesale 10% offe-Library read for1 day
2020-11-24: EC formal rejection for citation under EMCD
2019-11-13: D164/C065: BT approved the Annex ZA and Annexes ZZ for LVD and EMC and asked CCMC to make the standard available without further delay with the inclusion of the approves Annexes.
- Amendment129 pagesEnglish languagesale 10% offe-Library read for1 day
2020-11-24: EC formal rejection for citation under EMCD
2019-11-13: D164/C065: BT approved the Annex ZA and Annexes ZZ for LVD and EMC and asked CCMC to make the standard available without further delay with the inclusion of the approves Annexes.
- Amendment129 pagesEnglish languagesale 10% offe-Library read for1 day
This part of IEC 61000 focuses on the immunity requirements and test methods for electrical
and electronic equipment, under operational conditions, with regard to:
a) repetitive slow damped oscillatory waves occurring mainly in power, control and signal
cables installed in high voltage and medium voltage (HV/MV) substations;
b) repetitive fast damped oscillatory waves occurring mainly in power, control and signal
cables installed in gas insulated substations (GIS) and in some cases also air insulated
substations (AIS) or in any installation due to high-altitude electromagnetic pulse (HEMP)
phenomena.
The object of this document is to establish a common and reproducible reference for
evaluating the immunity of electrical and electronic equipment when subjected to damped
oscillatory waves on supply, signal, control and earth ports. The test method documented in
this part of IEC 61000 describes a consistent method to assess the immunity of an equipment
or system against a defined phenomenon.
NOTE As described in IEC Guide 107, this is a basic EMC publication for use by product committees of the IEC.
As also stated in Guide 107, the IEC product committees are responsible for determining whether this immunity
test standard is applied or not, and if applied, they are responsible for determining the appropriate test levels and
performance criteria. 1
The document defines:
– test voltage and current waveforms;
– ranges of test levels;
– test equipment;
– calibration and verification procedures of test equipment;
– test setups;
– test procedure.
- Standard22 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard – translation24 pagesSlovenian languagesale 10% offe-Library read for1 day
For emission requirements applies to electrical and electronic equipment intended for use within the environment existing at industrial (see 3.1.12) locations. This document does not apply to equipment that fall within the scope of IEC 61000-6-3. The environments encompassed by this document cover both indoor and outdoor locations. Emission requirements in the frequency range 9 kHz to 400 GHz are covered in this document and have been selected to provide an adequate level of protection of radio reception in the defined electromagnetic environment. No measurement needs to be performed at frequencies where no requirement is specified. These requirements are considered essential to provide an adequate level of protection to radio services. Not all disturbance phenomena have been included for testing purposes but only those considered relevant for the equipment intended to operate within the environments included within this document. Requirements are specified for each port considered. This generic EMC emission standard is to be used where no applicable product or productfamily EMC emission standard is available.
- Standard31 pagesEnglish languagesale 10% offe-Library read for1 day
This part of IEC 62026 applies to interfaces between low-voltage switchgear, controlgear, and
controllers (e.g. programmable controllers, personal computers, etc.).
This document does not apply to higher level industrial communication networks that have
become known as fieldbuses and are considered by IEC subcommittee 65C.
The purpose of this document is to harmonize and define rules, components and requirements
of a general nature applicable to industrial CDIs. Those features of the various CDI standards
which can be considered as general have therefore been brought together in this document.
For each CDI, two main documents are necessary to determine all requirements and tests:
a) this document, referred to as “IEC 62026-1” in the relevant CDI parts covering the various
types of CDIs;
b) the specific CDI part of the IEC 62026 series.
A specific CDI part may omit a general requirement if it is not applicable, or it may add to it if
it is inadequate in the particular case.
NOTE Product-specific requirements for products incorporating a CDI are given in the relevant product standards.
These requirements apply in addition to those given in this document.
- Standard17 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60730-2-14:2017 applies to electric actuators for use in, on, or in association with equipment for household and similar use. The equipment may use electricity, gas, oil, solid fuel, solar thermal energy, etc., or a combination thereof. This International Standard is applicable to controls for building automation within the scope of ISO 16484. This part 2-14 also applies to automatic electrical controls for equipment that may be used by the public, such as equipment intended to be used in shops, offices, hospitals, farms and commercial and industrial applications. EXAMPLE Controls for commercial catering, heating and air-conditioning equipment. Electric actuators for appliances are within the scope of IEC 60335. This second edition cancels and replaces the first edition, published in 1995, its Amendment 1 (2001) and its Amendment 2 (2007). This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: adapting it to the 5th Ed of IEC 60730-1, addition of checking electric actuators with action 1.AB or 2AB, and modification of tests under abnormal condition. This Part 2-14 is intended to be used in conjunction with IEC 60730-1. It was established on the basis of the 5th edition of that standard (2013). Consideration may be given to future editions of, or amendments to, IEC 60730-1. This part 2-14 supplements or modifies the corresponding clauses in IEC 60730-1, so as to convert that publication into the IEC standard: Particular requirements for electric actuators. Where this part 2-14 states "addition", "modification" or "replacement", the relevant requirement, test specification or explanatory matter in part 1 should be adapted accordingly. Where no change is necessary part 2-14 indicates that the relevant clause or subclause applies.
- Standard24 pagesEnglish languagesale 10% offe-Library read for1 day
Applies to electrical and electronic apparatus intended for use in residential, commercial and light-industrial environments. Immunity requirements in the frequency range 0 Hz to 400 GHz are covered. No tests need to be performed at frequencies where no requirements are specified. This generic EMC immunity standard is applicable if no relevant dedicated product or product-family EMC immunity standard exists. This standard applies to apparatus intended to be directly connected to a low-voltage public mains network or connected to a dedicated DC source which is intended to interface between the apparatus and the low-voltage public mains network. This standard applies also to apparatus which is battery operated or is powered by a non-public, but non-industrial, low-voltage power distribution system if this apparatus is intended to be used in the locations described below. The environments encompassed by this standard are residential, commercial and light-industrial locations, both indoor and outdoor. The following list, although not comprehensive, gives an indication of locations which are included: - residential properties, for example houses, apartments; - retail outlets, for example shops, supermarkets; - business premises, for example offices, banks; - areas of public entertainment, for example cinemas, public bars, dance halls; - outdoor locations, for example petrol stations, car parks, amusement and sports centres; - light-industrial locations, for example workshops, laboratories, service centres. Locations which are characterised by being supplied directly at low voltage from the public mains network are considered to be residential, commercial or light-industrial. The immunity requirements have been selected to ensure an adequate level of immunity for apparatus at residential, commercial and light-industrial locations. The levels do not, however, cover extreme cases, which may occur at any location, but with an extremely low probability of occurrenc
- Standard22 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard – translation24 pagesSlovenian languagesale 10% offe-Library read for1 day
applies to electrical and electronic apparatus intended for use in industrial environments, as described below. Immunity requirements in the frequency range 0 Hz to 400 GHz are covered. No tests need to be performed at frequencies where no requirements are specified. This generic EMC immunity standard is applicable if no relevant dedicated product or product-family EMC immunity standard exists. This standard applies to apparatus intended to be connected to a power network supplied from a high or medium voltage transformer dedicated to the supply of an installation feeding manufacturing or similar plant, and intended to operate in or in proximity to industrial locations, as described below. This standard applies also to apparatus which is battery operated and intended to be used in industrial locations. The environments encompassed by this standard are industrial, both indoor and outdoor. The immunity requirements have been selected to ensure an adequate level of immunity for apparatus at industrial locations. The levels do not, however, cover extreme cases, which may occur at any location, but with an extremely low probability of occurrence. Not all disturbance phenomena have been included for testing purposes in this standard, but only those considered as relevant for the equipment covered by this standard. These test requirements represent essential electromagnetic compatibility immunity requirements.
- Standard22 pagesEnglish languagesale 10% offe-Library read for1 day
Specifies electromagnetic compatibility (EMC) requirements for power supply units (PSUs) providing d.c. output(s) up to 200 V at a power level of up to 30 kW, operating from a.c. or d.c. source voltages of up to 600 V.
- Standard45 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard45 pagesEnglish languagesale 10% offe-Library read for1 day
Is intended as a product standard allowing the EMC conformity assessment of products of categories C1, C2 and C3 as defined in this part of EN 62040, before placing them on the market.The requirements have been selected so as to ensure an adequate level of electromagnetic compatibility (EMC) for UPS at public and industrial locations.
- Standard51 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard51 pagesEnglish languagesale 10% offe-Library read for1 day
specifies electromagnetic compatibility (EMC) requirements for power drive systems (PDSs). A PDS is defined in 3.1. These are adjustable speed a.c. or d.c. motor drives. Requirements are stated for PDSs with converter input and/or output voltages (line-to-line voltage), up to 35 kV a.c. r.m.s.
- Standard126 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard126 pagesEnglish languagesale 10% offe-Library read for1 day
IEC corrigendum
- Corrigendum3 pagesEnglish and French languagesale 10% offe-Library read for1 day
IEC corrigendum
- Corrigendum3 pagesEnglish and French languagesale 10% offe-Library read for1 day
IEC - Corrected version
2018-09-24 - GEM - offer under CLC D159/C070
- Corrigendum5 pagesEnglish languagesale 10% offe-Library read for1 day
IEC - Corrected version
2018-09-24 - GEM - offer under CLC D159/C070
- Corrigendum5 pagesEnglish languagesale 10% offe-Library read for1 day
This part of IEC 60947 applies to control circuit devices and switching elements intended for
controlling, signalling, interlocking, etc., of switchgear and controlgear.
It applies to control circuit devices having a rated voltage not exceeding 1 000 V a.c. (at a
frequency not exceeding 1 000 Hz) or 600 V d.c.
However, for operational voltages below 100 V a.c. or d.c., see 4.3.2.2.
This standard applies to specific types of control circuit devices such as:
• manual control switches, for example push-buttons, rotary switches, foot switches, etc.;
• electromagnetically operated control switches, either time-delayed or instantaneous, for
example contactor relays;
• pilot switches, for example pressure switches, temperature sensitive switches
(thermostats), programmers, etc.;
• position switches, for example control switches operated by part of a machine or
mechanism;
• associated control circuit equipment, for example indicator lights, etc.
NOTE 1 A control circuit device includes (a) control switch(es) and associated devices such as (an) indicator
light(s).
NOTE 2 A control switch includes (a) switching element(s) and an actuating system.
NOTE 3 A switching element can be a contact element or a semiconductor element.
It also applies to specific types of switching elements associated with other devices (whose
main circuits are covered by other standards) such as:
• auxiliary contacts of a switching device (e.g. contactor, circuit breaker. etc.) which are not
dedicated exclusively for use with the coil of that device;
• interlocking contacts of enclosure doors;
• control circuit contacts of rotary switches;
• control circuit contacts of overload relays.
Contactor relays also comply with the requirements and tests of IEC 60947-4-1 except for the
utilization category which comply with this standard.
This standard does not include the relays covered in IEC 60255 or in the IEC 61810 series,
nor automatic electrical control devices for household and similar purposes.
The colour requirements of indicator lights, push-buttons, etc., are found in IEC 60073 and
also in CIE S 0004/E-2001 from the Commission of Illumination (CIE).
- Standard119 pagesEnglish languagesale 10% offe-Library read for1 day
intended to be connected to circuits, the rated voltage of which does not exceed 1 000 V a.c. or
1 500 V d.c.; it also contains additional requirements for integrally fused circuit-breakers.
Circuit-breakers rated above 1 000 V a.c. but not exceeding 1 500 V a.c. may also be tested to
this standard.
It applies whatever the rated currents, the method of construction or the proposed applications
of the circuit-breakers may be.
The requirements for circuit-breakers which are also intended to provide earth leakage
protection are contained in Annex B.
The additional requirements for circuit-breakers with electronic over-current protection are
contained in Annex F.
The additional requirements for circuit-breakers for IT systems are contained in Annex H.
The requirements and test methods for electromagnetic compatibility of circuit-breakers are
contained in Annex J.
The requirements for circuit-breakers not fulfilling the requirements for over-current protection
are contained in Annex L.
The requirements for modular residual current devices (without integral current breaking
device) are contained in Annex M.
The requirements and test methods for electromagnetic compatibility of circuit-breaker
auxiliaries are contained in Annex N.
The requirements and test methods for d.c. circuit-breakers for use in photovoltaic (PV)
applications are contained in Annex P.
The requirements and test methods for circuit-breakers incorporating residual current
protection with automatic reclosing functions are contained in Annex R.
Supplementary requirements for circuit-breakers used as direct-on-line starters are given in
IEC 60947-4-1, applicable to low-voltage contactors and starters.
The requirements for circuit-breakers for the protection of wiring installations in buildings and
similar applications, and designed for use by uninstructed persons, are contained in
IEC 60898.
The requirements for circuit-breakers for equipment (for example electrical appliances) are
contained in IEC 60934.
For certain specific applications (for example traction, rolling mills, marine service) particular or
additional requirements may be necessary.
NOTE Circuit-breakers which are dealt with in this standard can be provided with devices for automatic opening
under predetermined conditions other than those of over-current and undervoltage as, for example, reversal of
power or current. This standard does not deal with the verification of operation under such pre-determined
conditions.
The object of this standard is to state:
a) the characteristics of circuit-breakers;
b) the conditions with which circuit-breakers shall comply with reference to:
1) operation and behaviour in normal service;
2) operation and behaviour in case of overload and operation and behaviour in case of
short-circuit, including co-ordination in service (selectivity and back-up protection);
3) dielectric properties;
c) tests intended for confirming that these conditions have been met and the methods to be
adopted for these tests;
d) information to be marked on or given with the apparatus.
- Standard249 pagesEnglish languagesale 10% offe-Library read for1 day
Specifies particular requirements for the type test of newly manufactured indoor time switches with operation reserve that are used to control electrical loads, multi-tariff registers and maximum demand devices of electricity metering equipment
- Amendment6 pagesEnglish languagesale 10% offe-Library read for1 day
CISPR 14-1:2016 specifies the requirements that apply to the emission of radio-frequency disturbances in the frequency range 9 kHz to 400 GHz from appliances, electric tools and similar apparatus, whether powered by AC or DC (including a battery). Also included in the scope of this standard are separate parts of the above mentioned equipment such as motors and switching devices (e.g. power or protective relays); however, no emission requirements apply to such separate parts, unless otherwise stated in this standard. This sixth edition cancels and replaces the fifth edition published in 2005, Amendment 1:2008 and Amendment 2:2011. This edition constitutes a technical revision. The contents of the corrigendum of October 2016 and interpretation sheet 1 and 2 of May 2017 have been included in this copy.
- Standard99 pagesEnglish languagesale 10% offe-Library read for1 day
Specifies particular requirements for the type test of newly manufactured indoor electronic ripple control receivers for the reception and interpretation of pulses of a single audio frequency superimposed on the voltage of the electricity distribution network and for the execution of the corresponding switching operations. In this system the mains frequency is generally used to synchronize the transmitter and receivers. Neither the control frequency nor the encoding are standardized in this standard.
- Amendment6 pagesEnglish languagesale 10% offe-Library read for1 day
Applies only to newly manufactured static var-hour meters of accuracy classes 2 and 3, for the measurement of alternating current electrical reactive energy in 50 Hz or 60 Hz networks and it applies to their type tests only. For practical reasons, this standard is based on a conventional definition of reactive energy for sinusoidal currents and voltages containing the fundamental frequency only.
- Amendment6 pagesEnglish languagesale 10% offe-Library read for1 day
Covers type tests for electricity metering equipment for indoor and outdoor application and to newly manufactured equipment designed to measure the electric energy on 50 Hz or 60 Hz networks, with a voltage up to 600 V. It applies to electromechanical or static meters for indoor and outdoor application consisting of a measuring element and register(s) enclosed together in a meter case. It also applies to operation indicator(s) and test output(s)
- Amendment13 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 62053-24:2014 applies only to newly manufactured transformer operated static var-hour meters of accuracy classes 0,5 S, and 1 S as well as direct connected static var-hour meters of accuracy class 1, for the measurement of alternating current electrical reactive energy in 50 Hz or 60 Hz networks and it applies to their type tests only. It uses a conventional definition of reactive energy where the reactive power and energy is calculated from the fundamental frequency components of the currents and voltages only.
- Amendment6 pagesEnglish languagesale 10% offe-Library read for1 day
CISPR 16-2-3:2016 is available as <a href="https://webstore.iec.ch/publication/25875">CISPR 16-2-3:2016 RLV</a> which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.<br /> <br /> CISPR 16-2-3:2016 specifies the methods of measurement of radiated disturbance phenomena in the frequency range of 9 kHz to 18 GHz. The aspects of measurement uncertainty are specified in CISPR 16-4-1 and CISPR 16-4-2. It has the status of a basic EMC publication in accordance with IEC Guide 107, "Electromagnetic compatibility - Guide to the drafting of electromagnetic compatibility publications". This fourth edition edition cancels and replaces the third edition published in 2010, its Amendment 1:2010 and its Amendment 2:2014. This edition constitutes a technical revision.
- Standard106 pagesEnglish languagesale 10% offe-Library read for1 day
2020-03-12: A11 allows citation EMCD
2019-08-13: Annex ZZ in line with EC suggestions received
2018-12-05: TC to clarify if improved FW is needed
2017-04-19: D156/C084 - Ratified standards not being made available
2017-03-28: BT decided to have this standard published (D156/C084)
2016-10: Publication on the hold pending Annex ZZ and positive assessment about EMC directive
- Amendment14 pagesEnglish languagesale 10% offe-Library read for1 day
This European standard applies to emission and immunity aspects of EMC for electrical and electronic apparatus and systems intended for use in railway fixed installations for power supply. This includes the power feed to the apparatus, the apparatus itself with its protective control circuits, trackside items such as switching stations, power autotransformers, booster transformers, substation power switchgear and power switchgear to other longitudinal and local supplies.
Filters operating at railway system voltage (for example, for harmonic suppression or power factor correction) are not included in this standard since each site has special requirements. Filters would normally have separate enclosures with separate rules for access. If electromagnetic limits are required, these will appear in the specification for the equipment.
If a port is intended to transmit or receive for the purpose of radio communication (intentional radiators, e.g. transponder systems), then the radiated emission requirement in this standard are not intended to be applicable to the intentional transmission from a radio-transmitter as defined by the ITU.
The frequency range considered is from DC to 400 GHz. No measurements need to be performed at frequencies where no requirement is specified.
Emission and immunity limits are given for items of apparatus which are situated:
a) within the boundary of a substation which delivers electric power to a railway;
b) beside the track for the purpose of controlling or regulating the railway power supply, including power factor correction;
c) along the track for the purpose of supplying electrical power to the railway other than by means of the conductors used for contact current collection, and associated return conductors. Included are high voltage feeder systems within the boundary of the railway which supply substations at which the voltage is reduced to the railway system voltage;
d) beside the track for controlling or regulating electric power supplies to ancillary railway uses. This category includes power supplies to marshalling yards, maintenance depots and stations;
e) various other non-traction power supplies from railway sources which are shared with railway traction.
The immunity levels given in this standard apply for:
- vital equipment such as protection devices;
- equipment having connections to the traction power conductors;
- apparatus inside the 3 m zone;
- ports of apparatus inside the 10 m zone with connection inside the 3 m zone;
- ports of apparatus inside the 10 m zone with cable length > 30 m.
Apparatus and systems which are in an environment which can be described as residential, commercial or light industry, even when placed within the physical boundary of the railway substation, shall comply with EN 61000 6 1:2007 for immunity and EN 61000 6 3:2007 for emission requirements.
Excluded from the immunity requirements of this standard is power supply apparatus which is intrinsically immune to the tests defined in Tables 1 to 6.
NOTE An example is an 18 MVA 230 kV to 25 kV power supply transformer.
These specific provisions are to be used in conjunction with the general provisions in EN 50121 1.
This part of the standard covers requirements for both apparatus and fixed installations. The sections for fixed installations are not relevant for CE marking.
- Standard20 pagesEnglish languagesale 10% offe-Library read for1 day
Specifies general requirements for the type test of newly manufactured indoor tariff and load control equipment, like electronic ripple control receivers and time switches that are used to control electrical loads, multi-tariff registers and maximum demand indicator devices.
- Amendment16 pagesEnglish languagesale 10% offe-Library read for1 day
Applies only to newly manufactured static watt-hour meters of accuracy classes 0,2 S and 0,5 S, for the measurement of alternating current electrical active energy in 50 Hz or 60 Hz networks and it applies to their type tests only.
- Amendment7 pagesEnglish languagesale 10% offe-Library read for1 day