Standard Specification for Poly(Vinyl Chloride) (PVC) Corrugated Sewer Pipe With a Smooth Interior and Fittings

SCOPE
1.1 This specification covers requirements, test methods, and materials for 4 to 36-in. diameter poly(vinyl chloride) (PVC) corrugated pipe with a smooth interior. This profile wall pipe consists of an outer corrugated wall fused to a smooth inner wall providing pipe stiffness levels of 46 psi and 115psi. Joints and fittings are included in this specification.
1.2 The requirements of this specification are intended to provide pipe and fittings suitable for underground use in nonpressure applications for sanitary sewers, storm sewers, and perforated and unperforated pipes for subdrainage.
Note 1—Industrial waste disposal lines should be installed only with the specific approval of the cognizant code authority, since chemicals not commonly found in drains and sewers and temperatures in excess of 140°F (60°C) may be encountered.
1.3 Pipe and fittings produced to this specification shall be installed in accordance with Practice D 2321.
Note 2—For perforated pipe applications, the size of the embedment zone and permeability of the embedment material are important to the system's ability to provide the desired level of infiltration or exfiltration. The gradation of the embedment material must be compatible with the perforation slot size to avoid backfill migration into the pipe.
1.4 The values stated in inch-pound units are to be regarded as the standard. The values provided in parentheses are for information purposes only.
1.5 The following precautionary caveat pertains only to the test method portion, Section , of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

General Information

Status
Historical
Publication Date
30-Sep-2003
Technical Committee
Drafting Committee
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM F949-03 - Standard Specification for Poly(Vinyl Chloride) (PVC) Corrugated Sewer Pipe With a Smooth Interior and Fittings
English language
10 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
An American National Standard
Designation: F 949 – 03
Standard Specification for
Poly(Vinyl Chloride) (PVC) Corrugated Sewer Pipe With a
1
Smooth Interior and Fittings
This standard is issued under the fixed designation F 949; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
1. Scope 2. Referenced Documents
2
1.1 This specification covers requirements, test methods, 2.1 ASTM Standards:
and materials for 4 to 36-in. diameter poly(vinyl chloride) D618 Practice for Conditioning Plastics for Testing
(PVC)corrugatedpipewithasmoothinterior.Thisprofilewall D1600 Terminology for Abbreviated Terms Relating to
pipe consists of an outer corrugated wall fused to a smooth Plastics
inner wall providing pipe stiffness levels of 46 psi and 115psi. D1784 Specification for Rigid Poly(Vinyl Chloride) (PVC)
Joints and fittings are included in this specification. Compounds and Chlorinated Poly(Vinyl Chloride)
1.2 The requirements of this specification are intended to (CPVC) Compounds
provide pipe and fittings suitable for underground use in D2122 Test Method for Determining Dimensions of Ther-
nonpressureapplicationsforsanitarysewers,stormsewers,and moplastic Pipe and Fittings
perforated and unperforated pipes for subdrainage. D2152 Test Method for Adequacy of Fusion of Extruded
Poly(Vinyl Chloride) (PVC) Pipe and Molded Fittings by
NOTE 1—Industrial waste disposal lines should be installed only with
Acetone Immersion
the specific approval of the cognizant code authority, since chemicals not
D2321 Practice for Underground Installation of Thermo-
commonly found in drains and sewers and temperatures in excess of
140°F (60°C) may be encountered. plastic Pipe for Sewers and Other Gravity-Flow Applica-
tions
1.3 Pipe and fittings produced to this specification shall be
D2412 TestMethodforDeterminationofExternalLoading
installed in accordance with Practice D2321.
Characteristics of Plastic Pipe by Parallel-Plate Loading
NOTE 2—For perforated pipe applications, the size of the embedment
D2444 Test Method for Determination of the Impact Re-
zone and permeability of the embedment material are important to the
sistance of Thermoplastic Pipe and Fittings by Means of a
system’s ability to provide the desired level of infiltration or exfiltration.
Tup (Falling Weight)
The gradation of the embedment material must be compatible with the
D2564 Specification for Solvent Cements for Poly(Vinyl
perforation slot size to avoid backfill migration into the pipe.
Chloride) (PVC) Plastic Piping Systems
1.4 The values stated in inch-pound units are to be regarded
D2855 Practice for Making Solvent-Cemented Joints with
as the standard. The values provided in parentheses are for
Poly(Vinyl Chloride) (PVC) Pipe and Fittings
information purposes only.
D3034 Specification for Polyethylene (PE) Plastic Pipe
1.5 The following precautionary caveat pertains only to the
(DR-PR) Based on Controlled Outside Diameter
test method portion, Section 7, of this specification: This
D3212 Specification for Joints for Drain and Sewer Plastic
standard does not purport to address all of the safety concerns,
Pipes Using Flexible Elastomeric Seals
if any, associated with its use. It is the responsibility of the user
F412 Terminology Relating to Plastic Piping Systems
of this standard to establish appropriate safety and health
F477 Specification for Elastomeric Seals (Gaskets) for
practices and determine the applicability of regulatory limita-
Joining Plastic Pipe
tions prior to use.
1 2
This specification is under the jurisdiction ofASTM Committee F17 on Plastic For referenced ASTM standards, visit the ASTM website, www.astm.org, or
Piping Systems and is the direct responsibility of Subcommittee F17.62 on Sewer. contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
Current edition approved Oct. 1, 2003. Published October 2003. Originally Standards volume information, refer to the standard’s Document Summary page on
approved in 1985. Last previous edition approved in 2001 as F949–01a. the ASTM website.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1

---------------------- Page: 1 ----------------------
F 949–03
F679 Specification for Poly(Vinyl Chloride) (PVC) Large- inclusions, or other injurious defects. The pipe shall be as
Diameter Plastic Gravity Sewer Pipe and Fittings uniform as commercially practical in color, opacity, density,
F1057 PracticeforEstimatingtheQualityofExtrudedPoly and other physical properties. Slo
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.