Standard Practice for Evaluation of Laboratories Testing Hydraulic Cement

SCOPE
1.1 This practice covers the technical training and experience of laboratory testing personnel and identifies the minimum technical requirements for laboratory equipment used in testing of hydraulic cement as prescribed by ASTM.
1.2 This practice provides minimum criteria for evaluating the capability of a laboratory to perform chemical or physical tests listed in the various specifications on hydraulic cement (see Note 1).
Note 1— Relevant hydraulic cement specifications are Specifications C 91, C 150, C 595, C 845, and Performance Specification C 1157.
1.3 The SI units are to be regarded as the standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

General Information

Status
Historical
Publication Date
30-Jun-2005
Technical Committee
Current Stage
Ref Project

Relations

Buy Standard

Standard
ASTM C1222-05 - Standard Practice for Evaluation of Laboratories Testing Hydraulic Cement
English language
4 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation:C1222–05
Standard Practice for
1
Evaluation of Laboratories Testing Hydraulic Cement
This standard is issued under the fixed designation C 1222; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
1. Scope C 185 Test Method for Air Content of Hydraulic Cement
Mortar
1.1 This practice covers the technical training and experi-
C 187 Test Method for Normal Consistency of Hydraulic
ence of laboratory testing personnel and identifies the mini-
Cement
mum technical requirements for laboratory equipment used in
C 191 Test Method for Time of Setting of Hydraulic Ce-
testing of hydraulic cement as prescribed by ASTM.
ment by Vicat Needle
1.2 This practice provides minimum criteria for evaluating
C 204 Test Method for Fineness of Hydraulic Cement by
the capability of a laboratory to perform chemical or physical
Air Permeability Apparatus
tests listed in the various specifications on hydraulic cement
C 219 Terminology Relating to Hydraulic Cement
(see Note 1).
C 230 Specification for Flow Table for Use in Tests of
NOTE 1—Relevant hydraulic cement specifications are Specifications
Hydraulic Cement
C91, C 150, C 595, C 845, and Performance Specification C 1157.
C 266 Test Method for Time of Setting of Hydraulic-
1.3 The SI units are to be regarded as the standard.
Cement Paste by Gillmore Needles
1.4 This standard does not purport to address all of the
C 305 PracticeforMechanicalMixingofHydraulicCement
safety concerns, if any, associated with its use. It is the
Pastes and Mortars of Plastic Consistency
responsibility of the user of this standard to establish appro-
C 451 Test Method for Early Stiffening of Portland Cement
priate safety and health practices and determine the applica-
(Paste Method)
bility of regulatory limitations prior to use.
C 595 Specification for Blended Hydraulic Cements
C 778 Specification for Standard Sand
2. Referenced Documents
C 845 Specification for Expansive Hydraulic Cement
2
2.1 ASTM Standards:
C 1157 Performance Specification for Blended Hydraulic
C91 Specification for Masonry Cement
Cement
C 109/C 109M Test Method for Compressive Strength of
E4 Practices for Force Verification of Testing Machines
Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube
2.2 Other Documents:
3
Specimens)
ACI 116R Cement and Concrete Terminology
C114 Test Methods for Chemical Analysis of Hydraulic
3. Terminology
Cement
C115 Test Method for Fineness of Portland Cement by the
3.1 Definitions:
Turbidimeter
3.1.1 inspection, n—a process of measuring, examining,
C 125 Terminology Relating to Concrete and Concrete
testing, gaging, or using other procedures to ascertain the
Aggregates
quality or state, detect errors or defects, or otherwise appraise
C 150 Specification for Portland Cement
materials, products, services, systems, or environments when
C 151 Test Method for Autoclave Expansion of Portland
compared to preestablished criteria.
Cement
3.1.2 Additional definitions may be found in Terminologies
C 125 and C 219, PracticesE4, and ACI 116R.
1 3.2 Definitions of Terms Specific to This Standard:
This practice is under the jurisdiction ofASTM Committee C01 on Cement and
is the direct responsibility of Subcommittee C01.95 on Coordination of Standards. 3.2.1 evaluation authority, n—an independent entity, apart
Current edition approved July 1, 2005. Published July 2005. Originally approved
from the organization being evaluated, that can provide an
in 1991. Last previous edition approved in 2003 as C 1222 – 03.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
3
Standards volume information, refer to the standard’s Document Summary page on Available fromAmerican Concrete Institute (ACI), P.O. Box 9094, Farmington
the ASTM website. Hills, MI 48333.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1

---------------------- Page: 1 ----------------------
C1222–05
unbiased evaluation of the organization and shall have the 6. Human Resources
capability to assess the technical activities of testing laborato-
6.1 The manager of the laboratory shall be a chemist,
ries (see Discussion).
materials analyst, or an engineer and a full-time employee of
3.2.1.1 Discussion—One such evaluation authority is the
the organization having at least three years supervisory expe-
4
Cement and Concrete Reference Laboratory (CCRL). Labo-
rience in the testing of hydraulic cement; however, a person
ratory inspection is broadened into accreditation programs by
with equivalent scie
...