ASTM E336-97e1
(Test Method)Standard Test Method for Measurement of Airborne Sound Insulation in Buildings
Standard Test Method for Measurement of Airborne Sound Insulation in Buildings
SCOPE
1.1 Measures of Acoustical Insulation- This test method covers procedures for determining the sound insulation between two rooms in a building. The evaluation may be made including all paths by which sound is transmitted or attention may be focused only on the dividing partition. The word "partition" in this test method includes all types of walls, floors, or any other boundaries separating two spaces. The boundaries may be permanent, operable, or movable.
1.2 Application to Building Specifications:
1.2.1 Sound Transmission Class or Transmission Loss Specifications- Building specifications may require that partitions have a certain minimum sound transmission class (STC) or transmission losses (TL). When it is required to demonstrate that a specific partition in a finished building complies with such specifications, a test satisfying the requirements of Annex A1 will be required.
1.2.1.1 Measurements may be made in accordance with the main body of this test method and with the requirements in Annex A1 without taking any steps to eliminate flanking transmission along paths other than that through the common partition. Transmission loss values can then be calculated as though the partition in question were the only transmission path. These apparent transmission loss values give a lower limit for the performance of the partition. Clearly when these values exceed the specifications, no further investigation is needed. If the partition is apparently not in compliance, then the procedures described in Annex A2 to reduce flanking transmission should be followed and the partition re-tested.
1.2.2 Sound Isolation Specifications- where a building code specifies minimum values of noise isolation class (NIC) or normalized noise isolation class (NNIC), then only the procedures in the main body of the test method are necessary. Of the available single-number ratings, NNIC relates best to occupant satisfaction in an occupied building.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
General Information
Relations
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
e1
Designation:E336–97
Standard Test Method for
1
Measurement of Airborne Sound Insulation in Buildings
This standard is issued under the fixed designation E336; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
1
e NOTE—Equation 3 was editorially revised in August 2003.
INTRODUCTION
This test method is part of a set of standards for evaluating the sound-insulating properties of
building elements. It is designed to measure the sound isolation between two rooms or the
performance of a partition element installed as an interior part of a building. Others in the set cover
the airborne sound transmission loss of an isolated partition element in a controlled laboratory
environment (Test Method E90), the laboratory measurement of impact sound transmission through
floors(TestMethodE492),themeasurementofimpactsoundtransmissioninbuildings(TestMethod
E1007),themeasurementofsoundtransmissionthroughbuildingfacadesandfacadeelements(Guide
E966), the measurement of sound transmission through a common plenum between two rooms (Test
Method E1414), a quick method for the determination of airborne sound isolation in multiunit
buildings (Practice E597), and the measurement of sound transmission through door panels and
systems (Test Method E1408).
1. Scope though the partition in question were the only transmission
path. These apparent transmission loss values give a lower
1.1 Measures of Acoustical Insulation—This test method
limit for the performance of the partition. Clearly when these
covers procedures for determining the sound insulation be-
values exceed the specifications, no further investigation is
tween two rooms in a building. The evaluation may be made
needed. If the partition is apparently not in compliance, then
including all paths by which sound is transmitted or attention
the procedures described in Annex A2 to reduce flanking
may be focused only on the dividing partition. The word
transmission should be followed and the partition retested.
“partition” in this test method includes all types of walls,
1.2.2 Sound Isolation Specifications—Where a building
floors, or any other boundaries separating two spaces. The
code specifies minimum values of noise isolation class (NIC)
boundaries may be permanent, operable, or movable.
or normalized noise isolation class (NNIC), then only the
1.2 Application to Building Specifications:
procedures in the main body of the test method are necessary.
1.2.1 Sound Transmission Class or Transmission Loss
Of the available single number ratings, NNIC relates best to
Specifications—Building specifications may require that parti-
occupant satisfaction in an occupied building.
tions have a certain minimum sound transmission class (STC)
1.3 This standard does not purport to address all of the
ortransmissionlosses(TL).Whenitisrequiredtodemonstrate
safety concerns, if any, associated with its use. It is the
that a specific partition in a finished building complies with
responsibility of the user of this standard to establish appro-
such specifications, a test satisfying the requirements ofAnnex
priate safety and health practices and determine the applica-
A1 will be required.
bility of regulatory limitations prior to use.
1.2.1.1 Measurements may be made in accordance with the
main body of this test method and with the requirements in
2. Referenced Documents
Annex A1 without taking any steps to eliminate flanking
2.1 ASTM Standards:
transmission along paths other than that through the common
2
C634 Terminology Relating to Environmental Acoustics
partition. Transmission loss values can then be calculated as
E90 Test Method for Laboratory Measurement ofAirborne
2
Sound Transmission Loss of Building Partitions
2
1
This test method is under the jurisdiction of ASTM Committee E-33 on E413 Classification for Rating Sound Insulation
EnvironmentalAcousticsandisthedirectresponsibilityofSubcommitteeE33.03on
Sound Transmission.
Current edition approved March 10, 1997. Published August 1997. Originally
2
published as E336–71. Last previous edition E336–96.
Annual Book of ASTM Standards, Vol 04.06.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1
---------------------- Page: 1 ----------------------
e1
E336–97
E492 Test Method for Laboratory Measurement of Impact logarithm of the ratio, of the airborne sound power incident on
Sound Transmission Through Floor-Ceiling Assemblies the partition to the sound power transmitted by the partition
2