SCOPE
1.1 This specification covers commercial electric food cutters with a rotating shallow bowl to carry food products through a set of rotating vertical knives that are on an axis perpendicular to the radii of the bowl. The food cutter can be for counter or table mounting, furnished with or without a table.
1.2 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only.
1.3 The following precautionary caveat pertains only to the test method portion, Section 10, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
General Information
Relations
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: F 1126 – 03
Standard Specification for
1
Food Cutters (Electric)
This standard is issued under the fixed designation F 1126; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
4
1. Scope ANSI/UL 969 Marking and Labeling Systems
2.4 ANSI Standard:
1.1 This specification covers commercial electric food cut-
ANSI Z1.4 Sampling Procedures and Tables for Inspection
ters with a rotating shallow bowl to carry food products
5
by Attributes
through a set of rotating vertical knives that are on an axis
2.5 Military Standards:
perpendicular to the radii of the bowl. The food cutter can be
MIL-STD-1399/300 Interface Standard for Shipboard Sys-
for counter or table mounting, furnished with or without a
6
tems, Section 300A, Electric Power, Alternating Current
table.
MIL-STD-167/1 MechanicalVibration of Shipboard Equip-
1.2 The values stated in inch-pound units are to be regarded
ment (Type I-Environmental and Type II-Internally Ex-
as the standard. The values given in parentheses are for
6
cited)
information only.
MIL-STD-461 Requirements for the Control of Electro-
1.3 The following precautionary caveat pertains only to the
magnetic Interference Characteristics of Subsystems and
test method portion, Section 10, of this specification: This
6
Equipment
standard does not purport to address all of the safety concerns,
if any, associated with its use. It is the responsibility of the user
3. Terminology
of this standard to establish appropriate safety and health
3.1 Definitions:
practices and determine the applicability of regulatory limita-
3.1.1 electric food cutter, n—machine that uniformly re-
tions prior to use.
duces food products to a small particle size for salads, spreads,
2. Referenced Documents bread crumbs, and other food service recipes.
2
3.1.1.1 Discussion—Reduction of food product is accom-
2.1 ASTM Standards:
plished by combining the rotation of the product bowl with the
D 3951 Practice for Commercial Packaging
perpendicular high-speed rotation of a set of stainless steel
F 760 Specification for Food Service Equipment Manuals
cutlery knives. The food cutter shall consist of the following
F 1166 Practice for Human Engineering Design for Marine
principal parts: base, legs (optional), product bowl, knives,
Systems, Equipment, and Facilities
bowl cover with interlock, motor, controls, and attachment
2.2 NSF Standards:
power take-off hub (optional) for attachments listed in 6.5.1.
NSF/ANSI 8 Commercial Powered Food Preparation
3
Equipment
4. Classification
3
NSF/ANSI 2 Food Equipment
3 4.1 General—Food cutters shall be of the following types,
NSF Food Service Equipment Listing (current year)
sizes, and classes:
2.3 Underwriters Laboratories Standards:
4.1.1 Types:
ANSI/UL763 Motor-Operated Commercial Food Preparing
4 4.1.1.1 Type I—This machine shall have a rotating product
Machines
bowl with rotating knives and power take-off hub to drive
attachments.
4.1.1.2 Type II—This machine shall have a rotating product
1
This specification is under the jurisdiction of ASTM Committee F26 on Food
bowl with rotating knives without a power take-off hub.
Service Equipment and is the direct responsibility of Subcommittee F26.04 on
4.1.2 Sizes:
Mechanical Preparation Equipment.
3
Current edition approved March 10, 2003. Published March 2003. Originally
4.1.2.1 Size 1—14-in. (355.6-mm) inside diameter, 2 ⁄4-in.
approved in 1992. Last previous edition approved in 1997 as F 1126 – 97.
(70-mm) deep bowl with a minimum capacity equal to 5 lb
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
(2.27 kg) of fresh meat.
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
Standards volume information, refer to the standard’s Document Summary page on
the ASTM website.
3 5
Available from NSF International, P.O. Box 130140, 789 N. Dixboro Rd.,Ann Available fromAmerican National Standards Institute (ANSI), 25 W. 43rd St.,
Arbor, MI 48113-0140. 4th Floor, New York, NY 10036.
4 6
Available from Underwriters Laboratories (UL), Corporate Progress, 333 AvailablefromStandardizationDocumentsOrderDesk,Bldg.4SectionD,700
Pfingsten Rd., Northbrook, IL 60062. Robbins Ave., Philadelphia, PA 19111-5094, Attn: NPODS.
Copyright ©ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA19428-2959, United States.
1
---------------------- Page: 1 ----------------------
F1126–03
5
4.1.2.2 Size 2—18-in. (457.2-mm) inside diameter, 3 ⁄8-in. 6.1.4 Human Factors Criteria—Human factors engineering
(92.1-mm) deep bowl with a minimum capacity equal to 14 lb criteria, principles and practi
...