ASTM F1871-20
(Specification)Standard Specification for Folded/Formed Poly (Vinyl Chloride) Pipe Type A for Existing Sewer and Conduit Rehabilitation
Standard Specification for Folded/Formed Poly (Vinyl Chloride) Pipe Type A for Existing Sewer and Conduit Rehabilitation
SCOPE
1.1 This specification covers requirements and test methods for materials, dimensions, workmanship, flattening resistance, impact resistance, pipe stiffness, extrusion quality, and a form of marking for folded/formed poly (vinyl chloride) (PVC) pipe for existing sewer and conduit rehabilitation.
1.2 Pipe produced to this specification is for use in non-pressure sewer and conduit rehabilitation where the folded PVC pipe is installed into and then expanded to provide a close fit to the wall of the original conduit, forming a new structural pipe-within-a-pipe.
Note 1: For installation procedures refer to Practice F1867.
1.3 This specification includes pipe made only from materials specified in Section 6. This specification does not include pipe manufactured from reprocessed, recycled, or reclaimed PVC.
1.4 The values stated in inch-pound units are to be regarded as the standard. The SI units given in parentheses are provided for information only.
1.5 There is no similar or equivalent ISO Standard.
1.6 The following precautionary statement pertains only to the test method portion, Section 11, of this specification. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
General Information
Relations
Buy Standard
Standards Content (Sample)
This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the
Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Designation:F1871 −20
Standard Specification for
Folded/Formed Poly (Vinyl Chloride) Pipe Type A for
1
Existing Sewer and Conduit Rehabilitation
This standard is issued under the fixed designation F1871; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope* 2. Referenced Documents
2
2.1 ASTM Standards:
1.1 This specification covers requirements and test methods
for materials, dimensions, workmanship, flattening resistance, D618 Practice for Conditioning Plastics for Testing
D638 Test Method for Tensile Properties of Plastics
impact resistance, pipe stiffness, extrusion quality, and a form
of marking for folded/formed poly (vinyl chloride) (PVC) pipe D648 Test Method for Deflection Temperature of Plastics
Under Flexural Load in the Edgewise Position
for existing sewer and conduit rehabilitation.
D790 Test Methods for Flexural Properties of Unreinforced
1.2 Pipe produced to this specification is for use in non-
and Reinforced Plastics and Electrical Insulating Materi-
pressure sewer and conduit rehabilitation where the folded
als
PVCpipeisinstalledintoandthenexpandedtoprovideaclose
D1600 TerminologyforAbbreviatedTermsRelatingtoPlas-
fit to the wall of the original conduit, forming a new structural
tics
pipe-within-a-pipe.
D1784 Classification System and Basis for Specification for
NOTE 1—For installation procedures refer to Practice F1867.
Rigid Poly(Vinyl Chloride) (PVC) Compounds and Chlo-
rinated Poly(Vinyl Chloride) (CPVC) Compounds
1.3 This specification includes pipe made only from mate-
D2122 Test Method for Determining Dimensions of Ther-
rials specified in Section 6. This specification does not include
moplastic Pipe and Fittings
pipe manufactured from reprocessed, recycled, or reclaimed
D2152 Test Method for Adequacy of Fusion of Extruded
PVC.
Poly(Vinyl Chloride) (PVC) Pipe and Molded Fittings by
1.4 The values stated in inch-pound units are to be regarded
Acetone Immersion
as the standard. The SI units given in parentheses are provided
D2412 Test Method for Determination of External Loading
for information only.
Characteristics of Plastic Pipe by Parallel-Plate Loading
1.5 There is no similar or equivalent ISO Standard.
D2444 Practice for Determination of the Impact Resistance
of Thermoplastic Pipe and Fittings by Means of a Tup
1.6 The following precautionary statement pertains only to
(Falling Weight)
the test method portion, Section 11, of this specification. This
F412 Terminology Relating to Plastic Piping Systems
standard does not purport to address all of the safety concerns,
F1057 Practice for Estimating the Quality of Extruded Poly
if any, associated with its use. It is the responsibility of the user
(Vinyl Chloride) (PVC) Pipe by the Heat Reversion
of this standard to establish appropriate safety, health, and
Technique
environmental practices and determine the applicability of
F1867 Practice for Installation of Folded/Formed Poly (Vi-
regulatory limitations prior to use.
nyl Chloride) (PVC) Pipe Type A for Existing Sewer and
1.7 This international standard was developed in accor-
Conduit Rehabilitation
dance with internationally recognized principles on standard-
3
ization established in the Decision on Principles for the 2.2 Federal Standard:
Development of International Standards, Guides and Recom- Fed. Std. No. 123 Marking for Shipment (Civil Agencies)
3
mendations issued by the World Trade Organization Technical
2.3 Military Standard:
Barriers to Trade (TBT) Committee.
MIL-STD-129 Marking for Shipment and Storage
1 2
This specification is under the jurisdiction of Committee F17 on Plastic Piping For referenced ASTM standards, visit the ASTM website, www.astm.org, or
Systems and is the direct responsibility of Subcommittee F17.67 on Trenchless contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
Plastic Pipeline Technology. Standards volume information, refer to the standard’s Document Summary page on
Current edition approved Nov. 1, 2020. Published November 2020. Originally the ASTM website.
3
approved in 1998. Last previous edition approved in 2018 as F1871-18. DOI: Available from DLA Document Services, Building 4/D, 700 Robbins Ave.,
10.1520/F1871-20. Philadelphia, PA 19111-5094, http://quicksearch.dla.mil.
*A Summary of Changes section appears at the end of this standard
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1
----------------
...
This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: F1871 − 18 F1871 − 20
Standard Specification for
Folded/Formed Poly (Vinyl Chloride) Pipe Type A for
1
Existing Sewer and Conduit Rehabilitation
This standard is issued under the fixed designation F1871; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope*
1.1 This specification covers requirements and test methods for materials, dimensions, workmanship, flattening resistance, impact
resistance, pipe stiffness, extrusion quality, and a form of marking for folded/formed poly (vinyl chloride) (PVC) pipe for existing
sewer and conduit rehabilitation.
1.2 Pipe produced to this specification is for use in non-pressure sewer and conduit rehabilitation where the folded PVC pipe is
installed into and then expanded to provide a close fit to the wall of the original conduit, forming a new structural
pipe-within-a-pipe.
NOTE 1—For installation procedures refer to Practice F1867.
1.3 This specification includes pipe made only from materials specified in Section 6. This specification does not include pipe
manufactured from reprocessed, recycled, or reclaimed PVC.
1.4 The values stated in inch-pound units are to be regarded as the standard. The SI units given in parentheses are provided for
information only.
1.5 There is no similar or equivalent ISO Standard.
1.6 The following precautionary statement pertains only to the test method portion, Section 11, of this specification. This
standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user
of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory
limitations prior to use.
1.6 There is no similar or equivalent ISO Standard.
1.7 This international standard was developed in accordance with internationally recognized principles on standardization
established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued
by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
1
This specification is under the jurisdiction of Committee F17 on Plastic Piping Systems and is the direct responsibility of Subcommittee F17.67 on Trenchless Plastic
Pipeline Technology.
Current edition approved Nov. 15, 2018Nov. 1, 2020. Published February 2019November 2020. Originally approved in 1998. Last previous edition approved in 20112018
as F1871-11.-18. DOI: 10.1520/F1871-18.10.1520/F1871-20.
*A Summary of Changes section appears at the end of this standard
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1
---------------------- Page: 1 ----------------------
F1871 − 20
2. Referenced Documents
2
2.1 ASTM Standards:
D618 Practice for Conditioning Plastics for Testing
D638 Test Method for Tensile Properties of Plastics
D648 Test Method for Deflection Temperature of Plastics Under Flexural Load in the Edgewise Position
D790 Test Methods for Flexural Properties of Unreinforced and Reinforced Plastics and Electrical Insulating Materials
D1600 Terminology for Abbreviated Terms Relating to Plastics
D1784 Classification System and Basis for Specification for Rigid Poly(Vinyl Chloride) (PVC) Compounds and Chlorinated
Poly(Vinyl Chloride) (CPVC) Compounds
D2122 Test Method for Determining Dimensions of Thermoplastic Pipe and Fittings
D2152 Test Method for Adequacy of Fusion of Extruded Poly(Vinyl Chloride) (PVC) Pipe and Molded Fittings by Acetone
Immersion
D2412 Test Method for Determination of External Loading Characteristics of Plastic Pipe by Parallel-Plate Loading
D2444 Practice for Determination of the Impact Resistance of Thermoplastic Pipe and Fittings by Means of a Tup (Falling
Weight)
F412 Terminology Relating to Plastic Piping Systems
F1057 Practice for Estimating the Quality of Extruded Poly (Vinyl Chloride) (PVC) Pipe by the Heat Reversion Technique
F1867 Practice for Installation of Folded/Formed Poly (Vinyl Chloride) (PVC) Pipe Type A for Existing Sewer and Conduit
Rehabilitation
3
2.2 Federal Standard:
Fed. Std. No. 123 Marking for Shipment (Civil Agencies)
3
2.3 Military Standard:
MIL-STD-129 Marking for Shipment and Storage
3. Terminology
3.1 Definitions—Definitions are in accordance with Terminology F412, and abb
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.