Standard Specification for Poly(Vinyl Chloride) (PVC) Large-Diameter Plastic Gravity Sewer Pipe and Fittings

SCOPE
1.1 This specification covers requirements and test methods for materials, dimensions, workmanship, flattening resistance, impact resistance, pipe stiffness, extrusion quality, joining system, and a form of marking for large diameters, 18 to 48 in. poly(vinyl chloride) (PVC) sewer pipe and fittings with integral bell elastomeric seal joints and smooth inner walls.
1.2 The requirements of this specification are intended to provide pipe and fittings suitable for nonpressure drainage of sewage and surface water. Pipe and fittings produced to this specification should be installed in accordance with Practice D 2321.
Note 1—Industrial waste disposal lines should be installed only with the specific approval of the governing code authority since temperatures in excess of 140°F (60°C) and chemicals not commonly found in drains and sewers may be encountered.
1.3 The values stated in inch-pound units are to be regarded as the standard. The values in parentheses are provided for information purposes only.
1.4 The following precautionary caveat pertains only to the test method portion, Section 7, of this specification: This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability or regulatory limitations prior to use.

General Information

Status
Historical
Publication Date
09-Aug-2003
Technical Committee
Drafting Committee
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM F679-03 - Standard Specification for Poly(Vinyl Chloride) (PVC) Large-Diameter Plastic Gravity Sewer Pipe and Fittings
English language
6 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
An American National Standard
Designation: F 679 – 03
Standard Specification for
Poly(Vinyl Chloride) (PVC) Large-Diameter Plastic Gravity
1
Sewer Pipe and Fittings
This standard is issued under the fixed designation F679; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
1. Scope D1784 Specification for Rigid Poly(Vinyl Chloride) (PVC)
Compounds and Chlorinated Poly(Vinyl Chloride)
1.1 This specification covers requirements and test methods
3
(CPVC) Compounds
for materials, dimensions, workmanship, flattening resistance,
D2122 Test Method for Determining Dimensions of Ther-
impact resistance, pipe stiffness, extrusion quality, joining
4
moplastic Pipe and Fittings
system, and a form of marking for large diameters, 18 to 48 in.
D2152 Test Method for Adequacy of Fusion of Extruded
poly(vinyl chloride) (PVC) sewer pipe and fittings with inte-
Poly(Vinyl Chloride) (PVC) Pipe and Molded Fittings by
gral bell elastomeric seal joints and smooth inner walls.
4
Acetone Immersion
1.2 The requirements of this specification are intended to
D2321 Practice for Underground Installation of Thermo-
provide pipe and fittings suitable for nonpressure drainage of
plastic Pipe for Sewers and Other Gravity-Flow Applica-
sewage and surface water. Pipe and fittings produced to this
4
tions
specification should be installed in accordance with Practice
D2412 TestMethodforDeterminationofExternalLoading
D2321.
4
Characteristics of Plastic Pipe by Parallel-Plate Loading
NOTE 1—Industrial waste disposal lines should be installed only with
D2444 Test Method for Determination of the Impact Re-
thespecificapprovalofthegoverningcodeauthoritysincetemperaturesin
sistance of Thermoplastic Pipe and Fittings by Means of a
excess of 140°F (60°C) and chemicals not commonly found in drains and
4
Tup (Falling Weight)
sewers may be encountered.
D2855 Practice for Making Solvent-Cemented Joints with
1.3 The values stated in inch-pound units are to be regarded 4
Poly(Vinyl Chloride) (PVC) Pipe and Fittings
as the standard. The values in parentheses are provided for
D3212 Specification for Joints for Drain and Sewer Plastic
information purposes only. 4
Pipes Using Flexible Elastomeric Seals
1.4 The following precautionary caveat pertains only to the
F402 Practice for Safe Handling of Solvent Cements,
test method portion, Section 7, of this specification: This
Primers,andCleanersUsedforJoiningThermoplasticPipe
standard does not purport to address all of the safety problems,
4
and Fittings
if any, associated with its use. It is the responsibility of the user
4
F412 Terminology Relating to Plastic Piping Systems
of this standard to establish appropriate safety and health
F477 Specification for Elastomeric Seals (Gaskets) for
practices and determine the applicability or regulatory limita-
4
Joining Plastic Pipe
tions prior to use.
2.2 Federal Standard:
5
Fed. Std. No. 123 Marking for Shipment (Civil Agencies)
2. Referenced Documents
2.3 Military Standard:
2.1 ASTM Standards:
5
MIL-STD-129 Marking for Shipment and Storage
2
D618 Practice for Conditioning Plastics for Testing
D1600 Terminology for Abbreviated Terms Relating to
3. Terminology
2
Plastics
3.1 Definitions:
1
This specification is under the jurisdiction ofASTM Committee F17 on Plastic
Piping Systems and is the direct responsibility of Subcommittee F17.62 on Sewer
3
Pipe. Annual Book of ASTM Standards, Vol 08.02.
4
Current edition approved August 10, 2003. Published September 2003. Origi- Annual Book of ASTM Standards, Vol 08.04.
5
nally approved in 1980. Last previous edition approved in 2001 as F679–01. Available from Standardization Documents, Order Desk, Bldg. 4, Section D,
2
Annual Book of ASTM Standards, Vol 08.01. 700 Robbins Ave., Philadelphia, PA 19111-5094.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1

---------------------- Page: 1 ----------------------
F679–03
3.1.1 General—Definitions used in the specification are in inclusions, or other injurious defects. The pipe shall be as
accordance with Terminology F412, unless otherwise indi- uniform as commercially practical in color, opacity, density,
cated.Theabbreviationforpoly(vinylchloride)pipeisPVC,in and other physical properties.
accordance with Terminology D1600.
6.2 Pipe Dimensions:
6.2.1 Pipe Diameter—The average outside diameter of the
4. Materials
pipe shall meet the requirements given in Table 1, when
4.1 Basic Materials—The pipe shall be made of PVC
measured in accordance with Test Method D2122.
plastichavingaminimumcellclassificationof12364or12454
6.2.2 Wall Thickn
...

Questions, Comments and Discussion