Standard Specification for 30 to 60 in. [750 to 1500 mm] Polypropylene (PP) Triple Wall Pipe and Fittings for Non-Pressure Sanitary Sewer Applications

SCOPE
1.1 This specification covers requirements and test methods for triple wall polypropylene pipe and fittings. The nominal inside diameters covered are 30 to 60 in. [750 to 1600 mm].  
1.2 The requirements of this specification are intended to provide pipe and fittings suitable for underground use for non-pressure sanitary sewer systems. Pipe and fittings produced in accordance with this specification shall be installed in compliance with Practice D2321.  
1.3 This specification covers pipe and fittings with an essentially smooth interior wall, an essentially smooth exterior wall and an annular corrugated profile middle wall (Fig. 1).
1.4 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.  
1.5 The following precautionary statement applies only to Section 7 of this specification. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

General Information

Status
Historical
Publication Date
30-Apr-2011
Technical Committee
Drafting Committee
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM F2764/F2764M-11ae1 - Standard Specification for 30 to 60 in. [750 to 1500 mm] Polypropylene (PP) Triple Wall Pipe and Fittings for Non-Pressure Sanitary Sewer Applications
English language
8 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
´1
Designation:F2764/F2764M −11a AnAmerican National Standard
Standard Specification for
30 to 60 in. [750 to 1500 mm] Polypropylene (PP) Triple Wall
Pipe and Fittings for Non-Pressure Sanitary Sewer
1
Applications
ThisstandardisissuedunderthefixeddesignationF2764/F2764M;thenumberimmediatelyfollowingthedesignationindicatestheyear
of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval.
A superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1
ε NOTE—Revised designation to correspond with units statement in November 2013.
1. Scope* A666 Specification forAnnealed or Cold-WorkedAustenitic
Stainless Steel Sheet, Strip, Plate, and Flat Bar
1.1 This specification covers requirements and test methods
D256 Test Methods for Determining the Izod Pendulum
for triple wall polypropylene pipe and fittings. The nominal
Impact Resistance of Plastics
inside diameters covered are 30 to 60 in. [750 to 1600 mm].
D618 Practice for Conditioning Plastics for Testing
1.2 The requirements of this specification are intended to
D638 Test Method for Tensile Properties of Plastics
provide pipe and fittings suitable for underground use for
D790 Test Methods for Flexural Properties of Unreinforced
non-pressure sanitary sewer systems. Pipe and fittings pro-
and Reinforced Plastics and Electrical Insulating Materi-
duced in accordance with this specification shall be installed in
als
compliance with Practice D2321.
D792 Test Methods for Density and Specific Gravity (Rela-
1.3 This specification covers pipe and fittings with an
tive Density) of Plastics by Displacement
essentially smooth interior wall, an essentially smooth exterior D1238 Test Method for Melt Flow Rates of Thermoplastics
wall and an annular corrugated profile middle wall (Fig. 1).
by Extrusion Plastometer
D1505 Test Method for Density of Plastics by the Density-
1.4 The values stated in either SI units or inch-pound units
Gradient Technique
are to be regarded separately as standard. The values stated in
D1600 Terminology forAbbreviatedTerms Relating to Plas-
each system may not be exact equivalents; therefore, each
tics
system shall be used independently of the other. Combining
D2122 Test Method for Determining Dimensions of Ther-
values from the two systems may result in non-conformance
moplastic Pipe and Fittings
with the standard.
D2321 PracticeforUndergroundInstallationofThermoplas-
1.5 The following precautionary statement applies only to
tic Pipe for Sewers and Other Gravity-Flow Applications
Section 7 of this specification. This standard does not purport
D2412 Test Method for Determination of External Loading
to address all of the safety concerns, if any, associated with its
Characteristics of Plastic Pipe by Parallel-Plate Loading
use. It is the responsibility of the user of this standard to
D2444 Test Method for Determination of the Impact Resis-
establish appropriate safety and health practices and deter-
tance of Thermoplastic Pipe and Fittings by Means of a
mine the applicability of regulatory limitations prior to use.
Tup (Falling Weight)
D2990 Test Methods for Tensile, Compressive, and Flexural
2. Referenced Documents
Creep and Creep-Rupture of Plastics
2
2.1 ASTM Standards:
D3212 Specification for Joints for Drain and Sewer Plastic
Pipes Using Flexible Elastomeric Seals
1
This specification is under the jurisdiction ofASTM Committee F17 on Plastic
D3895 Test Method for Oxidative-Induction Time of Poly-
Piping Systems and is the direct responsibility of Subcommittee F17.62 on Sewer.
olefins by Differential Scanning Calorimetry
Current edition approved May 1, 2011. Published May 2011. Originally
D4101 Specification for Polypropylene Injection and Extru-
approved in 2010. Last previous edition approved in 2011 as F2764–11.
DOI:10.1520/D2764_F2764M–11AE01.
sion Materials
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
D4218 Test Method for Determination of Carbon Black
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
Content in Polyethylene Compounds By the Muffle-
Standards volume information, refer to the standard’s Document Summary page on
the ASTM website. Furnace Technique
*A Summary of Changes section appears at the end of this standard
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
´1
F2764/F2764M−11a
FIG. 1 Typical Triple Wall Pipe Profile
D4389 SpecificationforFinishedGlassFabricsWovenFrom 4. Ordering Information
Rovings
4.1 Orders for product made to this specification shall
D6992 Test Method for Accelerated Tensile Creep and
include the following information to adequately describe the
Creep-Rupture of Geosynthetic M
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.