Standard Specification for Woven Wire Plaster Base

SCOPE
1.1 This specification covers woven wire plaster base, flat or self-furring, with or without stiffener wires, and with or without backing, designed for use as a base to receive gypsum or portland cement based plaster.
1.2 The values stated in inch-pound units are to be regarded as the standard. The SI equivalents of inch-pound units are approximate.
1.3 The text of this standard references notes and footnotes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard.

General Information

Status
Historical
Publication Date
31-Dec-1995
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM C1032-96 - Standard Specification for Woven Wire Plaster Base
English language
2 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


NOTICE: This standard has either been superseded and replaced by a new version or discontinued.
Contact ASTM International (www.astm.org) for the latest information.
Designation: C 1032 – 96
Standard Specification for
Woven Wire Plaster Base
This standard is issued under the fixed designation C 1032; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
TABLE 1 Minimum Wire Diameter for Size of Opening
1. Scope *
Opening Size, in. (mm) Wire Diameter, in. (mm)
1.1 This specification covers woven wire plaster base, flat or
1 (25.4) 0.035 (0.89)
self-furring, with or without stiffener wires, and with or
1 ⁄2 (38.0) 0.0510 (1.295)
without backing, designed for use as a base to receive gypsum
or portland cement based plaster.
5.1.1 Factory attached backing shall provide a one mesh
1.2 The values stated in inch-pound units are to be regarded
wire to wire lap joint at one end and one edge of each flat sheet
as the standard. The SI equivalents of inch-pound units are
or roll. Attachment of the backing shall allow lapping of
approximate.
wire-to-wire and backing-to-backing of one mesh at ends and
1.3 The text of this standard references notes and footnotes
edges and shall permit full embedment in not less than ⁄4 in.
which provide explanatory material. These notes and footnotes
(6.4 mm) of plaster of not less than one half the total length and
(excluding those in tables and figures) shall not be considered
width of the wire.
as requirements of the standard.
5.1.2 Backing shall have a minimum tensile breaking
2. Referenced Documents strength (dry) of 20 lbf/in. (3.5 kN/m) width, as tested in
accordance with Federal Specification UU-P-31 B,
2.1 ASTM Standards:
Method 171.
A 641 Specification for Zinc-Coated (Galvanized) Carbon
Steel Wire
6. Dimensions, Weight, and Permissible Variations
C 11 Terminology Relating to Gypsum and Related Build-
3 6.1 Openings:
ing Materials and Systems
6.1.1 Woven wire plaster base shall be fabricated to provide
2.2 Federal Specifications:
the size of openings in accordance with Table 1, except that any
UU-B-790a Building Paper, Vegetable Fiber: Kraft, Water-
2 2
single opening shall be not more than 3.0 in. (1935.5 mm ).
proofed, Water Repellent and Fire Resistant
6.1.2 Wire diameter for opening size shall be in accordance
UU-P-31 B/Gen. Paper; General Specifications and Meth-
4 with Table 1.
ods of Testing
6.2 Diameter tolerance for galvanized wire shall be in
UU-P-31 B/171 Tensile Breaking Strength (Dry)
accordance with Table 2 of Specification A 641.
3. Terminology 6.3 Weight for woven wire plaster base shall be in accor-
dance with Table 2.
3.1 Definitions—Definitions shall be in accordance with
6.4 When included as part of the woven wire plaster base,
Terminology C 11.
factory fabricated stiffener wires shall have a diameter not less
4. Material
than that specified in Table 1 and shall be continuous, parallel
to the long dimension of the plaster base, and shall occur at not
4.1 In accordance with Specification A 641 and Table 1.
more than 6-in. (154.4-mm) intervals.
4.2 Kraft Building Paper, Federal Specification UU-B-
6.5 Factory fabricated crimps for self-furring woven wire
790a.
plaster base shall provide a nominal ⁄4-in. (6.4-mm) separation
5. Physical Properties
between the back plane of the plaster base and the surface of
solid backing to permit embedment in both directions.
5.1 Backing:
6.6 Width of woven wire plaster base shall be not less than
36 in. (914 mm).
This specification is under the jurisdiction of ASTM Committee C-11 on
6.7 Length of woven wire plaster base shall be in accor-
Gypsum and Related Building Materials and Systems and is the direct responsibility
dance with Table 3.
of Subcommittee C11.02 on Specifications and Test Methods for A
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.