Standard Practice for Hydrostatic Leak Testing

SIGNIFICANCE AND USE
6.1 This practice is useful for quality control testing and field inspection of piping systems, pipelines, valves, and containers that are expected to retain liquids. It is not sensitive enough for leak testing when toxic or explosive gas is expected to be retained under pressure.
SCOPE
1.1 This practice covers the testing of components for leaks by pressurizing them inside with a liquid.  
1.2 This practice can be used on piping, valves, and containers with welded or fitted sections which can be sealed at their ends and which are designed for internal pressure.  
1.3 Basic procedures are described based on the type of inspection used. These procedures should be limited to finding leakage indications of 4.5 × 10−9 mol/s (1 × 10−4 Std cm3/s)2 or larger.  
1.4 Units—The values stated in SI units are to be regarded as standard. The values given in parentheses are mathematical conversions to inch-pound units that are provided for information only and are not considered standard.  
1.5 This standard does not purport to address the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

General Information

Status
Published
Publication Date
31-May-2022
Technical Committee
Drafting Committee
Current Stage
Ref Project

Relations

Buy Standard

Standard
ASTM E1003-13(2022) - Standard Practice for Hydrostatic Leak Testing
English language
3 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the
Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Designation: E1003 − 13 (Reapproved 2022)
Standard Practice for
Hydrostatic Leak Testing
This standard is issued under the fixed designation E1003; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope 2.2 ASNT Documents:
SNT-TC-1ARecommended Practice for Personal Qualifica-
1.1 This practice covers the testing of components for leaks
tion and Certification in Nondestructive Testing
by pressurizing them inside with a liquid.
ANSI/ASNT CP-189 ASNT Standard for Qualification and
1.2 This practice can be used on piping, valves, and con-
Certification of Nondestructive Testing Personnel
tainers with welded or fitted sections which can be sealed at
2.3 AIA Standard:
their ends and which are designed for internal pressure.
NAS-410Certification and Qualification of Nondestructive
1.3 Basic procedures are described based on the type of
Test Personnel
inspection used.These procedures should be limited to finding
−9 −4 3 2
leakageindicationsof4.5×10 mol/s(1×10 Stdcm /s) or
3. Terminology
larger.
3.1 Definitions—For definitions of terms used in this
1.4 Units—The values stated in SI units are to be regarded
practice, see Terminology E1316, Section E.
as standard. The values given in parentheses are mathematical
4. Summary of Practice
conversions to inch-pound units that are provided for informa-
tion only and are not considered standard.
4.1 Hydrostatic testing requires that a component be com-
1.5 This standard does not purport to address the safety pletely filled with a liquid, such as water. Pressure is slowly
concerns, if any, associated with its use. It is the responsibility
appliedtotheliquiduntiltherequiredpressureisreached.This
of the user of this standard to establish appropriate safety, pressure is held for the required time at which point the
health, and environmental practices and determine the appli-
component is inspected visually to locate leaks or the pressure
cability of regulatory limitations prior to use. on the gauge is recorded to determine the components total
1.6 This international standard was developed in accor-
leakage.
dance with internationally recognized principles on standard-
4.2 The two basic procedures are described together with
ization established in the Decision on Principles for the
methods for improving their sensitivity.
Development of International Standards, Guides and Recom-
4.2.1 Pressure Drop Indication—This procedure is used
mendations issued by the World Trade Organization Technical
primarily to measure total system leakage.
Barriers to Trade (TBT) Committee.
4.2.2 Visual Inspection for Leakage—This procedure is
intended primarily to locate leaks.
2. Referenced Documents
4.3 Ultrasonic pretesting for gross leaks is described.
2.1 ASTM Standards:
E543Specification forAgencies Performing Nondestructive
5. Basis of Application
Testing
5.1 The following items are subject to contractual agree-
E1316Terminology for Nondestructive Examinations
ment between the parties using or referencing this practice:
5.2 Personnel Qualification
This practice is under the jurisdiction of ASTM Committee E07 on Nonde-
5.2.1 If specified in the contractual agreement. Personnel
structive Testing and is the direct responsibility of Subcommittee E07.08 on Leak
performing examinations to this practice shall be qualified in
Testing Method.
CurrenteditionapprovedJune1,2022.PublishedJuly2022.Originallyapproved accordance with a nationally or internationally recognized
in 1984. Last previous edition approved in 2018 as E1003– 13(2018). DOI:
NDT personnel qualification practice or standard such as
10.1520/E1003-13R22.
The gas temperature is referenced to 0°C. To convert to another gas reference
temperature, T , multiply the leak rate by (T +273) ⁄273.
ref ref
3 4
For referenced ASTM standards, visit the ASTM website, www.astm.org, or AvailablefromAmericanSocietyforNondestructiveTesting(ASNT),P.O.Box
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM 28518, 1711 Arlingate Ln., Columbus, OH 43228-0518, http://www.asnt.org.
Standards volume information, refer to the standard’s Document Summary page on Available fromAerospace IndustriesAssociation ofAmerica, Inc. (AIA), 1000
the ASTM website. WilsonBlvd.,Suite1700,Arlington,VA22209-3928,http://www.aia-aerospace.org.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
E1003 − 13 (2022)
ANSI/ASNTCP-189,SNT-TC-1A,NAS-410,orsimilardocu- 8.2 Pressure Relief Valve.
ment and certified by the employer or certifying agency, as
8.3 Pressure Alarm.
applicable. The practice or standard used and its applicable
8.4 Emergency Pressure Shut-Off Valve.
revision shall be identified in the contractual agreement.
8.5 Trapped Air Vent.
5.3 Qualification of Nondestructive Agencies—If specified
in the contractual agreement, NDT agencies shall be qualified
8.6 Pressure Pump.
and evaluated as described in Specification E543. The appli-
8.7 Liquid Test Media.
cable edition of Specification E543 shall be specified in the
contractual agreement. 8.8 Pressure Hoses and Fittings.
5.4 Re-examination of Repaired/Reworked Items—Re- 8.9 Protection Chamber for High-Pressure Tests.
examinationofrepaired/reworkeditemsisnotaddressedinthis
practice, they shall be specified in the contractual agreement. 9. General Procedures
9.1 Openings:
6. Significance and Use
9.1.1 Seal all openings using plugs or covers that can
6.1 This practice is useful for quality control testing and
withstand the test pressure and can be completely removed
field inspection of piping systems, pipelines, valves, and
after the test.
containers that are expected to retain liquids. It is not sensitive
9.1.2 The test fluid inlet should be located on the bottom of
enoughforleaktestingwhentoxicorexplosivegasisexpected
the test object with the trapped air vent at the highest point.
to be retained under pressure.
9.1.3 Components rated at pressures below the test pressure
7. Interferences
must be isolated.
7.1 The interior and exterior welds and joints where leaks
9.2 Gauges—One or more test gauges must be connected to
are often found must be free of oil, grease, flux, slag, or other
the system. If more than one gauge is used, one may be a
contaminants that might temporarily block or mask leakage.
recording gauge. At least one gauge which is used for accep-
New systems should be tested prior to painting, where practi-
tance of the test shall be calibrated within 30 days prior to use.
cal.
One indicating gauge must be easily visible to the operator
controllingthepressurethroughoutthepressurizingandtesting
7.2 Hydrostatic testing should not be performed before a
cycle.
leak test using air or a tracer gas. The liquid test media may
clog small leaks causing later tests to be inaccurate.
9.3 Pre-Test Inspection:
9.3.1 Beforepressurizingisbegun,inspecttheoutsideofthe
7.3 Test liquid must be equal or above atmosphere tempera-
test object to verify that it is dry and all
...