ASTM C1029-02
(Specification)Standard Specification for Spray-Applied Rigid Cellular Polyurethane Thermal Insulation
Standard Specification for Spray-Applied Rigid Cellular Polyurethane Thermal Insulation
SCOPE
1.1 This specification covers the types and physical properties of spray applied rigid cellular polyurethane intended for use as thermal insulation. The operating temperatures of the surfaces to which the insulation is applied shall not be lower than -22°F (-30°C) or greater than +225°F (+107°C). For specific applications, the actual temperature limits shall be as agreed upon between the manufacturer and the purchaser.
1.2 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
General Information
Relations
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn. Contact ASTM
International (www.astm.org) for the latest information.
Designation: C 1029 – 02
Standard Specification for
Spray-Applied Rigid Cellular Polyurethane Thermal
1
Insulation
This standard is issued under the fixed designation C1029; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
1. Scope D1623 Test Method for Tensile and Tensile Adhesion
4
Properties of Rigid Cellular Plastics
1.1 This specification covers the types and physical proper-
D2126 TestMethodforResponseofRigidCellularPlastics
ties of spray applied rigid cellular polyurethane intended for
4
to Thermal and Humid Aging
use as thermal insulation. The operating temperatures of the
D2842 TestMethodforWaterAbsorptionofRigidCellular
surfaces to which the insulation is applied shall not be lower
5
Plastics
than−22°F (−30°C) or greater than+225°F (+107°C). For
D2856 Test Method for Open-Cell Content of Rigid Cel-
specific applications, the actual temperature limits shall be as
5
lular Plastics by the Air Pycnometer
agreed upon between the manufacturer and the purchaser.
E84 Test Method for Surface Burning Characteristics of
1.2 The values stated in inch-pound units are to be regarded
6
Building Materials
as the standard. The values given in parentheses are for
E96 Test Methods for Water Vapor Transmission of Mate-
information only.
2
rials
1.3 This standard does not purport to address all of the
safety concerns, if any, associated with its use. It is the
3. Terminology
responsibility of the user of this standard to establish appro-
3.1 Definitions—For definitions of terms used in this speci-
priate safety and health practices and determine the applica-
fication, refer to Terminologies C168 and D883.
bility of regulatory limitations prior to use.
4. Classification
2. Referenced Documents
4.1 Spray-applied rigid-cellular polyurethane thermal insu-
2.1 ASTM Standards:
lation covered by this specification is classified into four types
C165 Test Method for Measuring Compressive Properties
2 as follows:
of Thermal Insulations
2 4.1.1 Type I—Compressive strength 15 psi (104 kPa) mini-
C168 Terminology Relating to Thermal Insulation
mum.
C177 Test Method for Steady-State Heat Flux Measure-
4.1.2 Type II—Compressive strength 25 psi (173 kPa)
ments and Thermal Transmission Properties by Means of
2 minimum.
the Guarded-Hot-Plate Apparatus
4.1.3 Type III—Compressive strength 40 psi (276 kPa)
C236 Test Method for Steady–State Thermal Performance
3 minimum.
of BuildingAssemblies by Means of a Guarded Hot Box
4.1.4 Type IV—Compressive strength 60 psi (414 kPa)
C518 Test Method for Steady-State Thermal Transmission
2 minimum.
Properties by Means of the Heat Flow Meter Apparatus
4
D883 Terminology Relating to Plastics
5. Ordering Information
D1621 Test Method for Compressive Properties of Rigid
4 5.1 Orders for materials purchased under this specification
Cellular Plastics
shall include the following:
D1622 TestMethodforApparentDensityofRigidCellular
4 5.1.1 ASTM designation, year of issue, and title.
Plastics
5.1.2 Type (see 4.1).
5.1.3 R value or thickness required (see 10.1).
1
This specification is under the jurisdiction of ASTM Committee C16 on
5.1.4 Sampling, if different (see Section 8).
Thermal Insulation and is the direct responsibility of Subcommittee C16.22 on
5.1.5 If a certificate of compliance is required (see 13.1).
Organic and Nonhomogeneous Inorganic Thermal Insulations.
Current edition approved November 10, 2002. Published November 2002.
Originally published as C1029–85. Last previous edition C1029–96.
2
Annual Book of ASTM Standards, Vol 04.06.
3 5
Discontinued: see 2000 Annual Book of ASTM Standards, Vol.04.06. Annual Book of ASTM Standards, Vol 08.02.
4 6
Annual Book of ASTM Standards, Vol 08.01. Annual Book of ASTM Standards, Vol 04.07.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1
---------------------- Page: 1 ----------------------
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn. Contact ASTM
International (www.astm.org) for the latest information.
C1029–02
TABLE 1 Physical Properties
Requirements
Property
Type I Type II Type III Type IV
2 2
Thermal resistance of 1.0 in. (25 mm) thickness, min, °F·ft ·h/Btu (K·m /W) 6.2 6.2 6.2 6.2
at mean temperature 75°F (24°C)
Compressive strength, at yield or 10 % deformation, whichever comes first, 15 (104) 25 (173) 40 (276) 60 (414)
min, psi (kPa)
Water vapor permeability, max, perm-inches (ng/Pa·s·m) 3.0 (4.4) 3.0 (4.4) 3.0 (4.4) 3.0 (4.4)
Water absorption, max, volume
...
Questions, Comments and Discussion