Standard Test Method for Apparent Density of Metal Powders and Compounds Using the Scott Volumeter

SCOPE
1.1 This test method covers determination of the apparent density of metal powders and related compounds using the Scott Volumeter, also known as the Paint Pigment Volumeter.  
1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.  
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

General Information

Status
Historical
Publication Date
09-Mar-1998
Current Stage
Ref Project

Relations

Buy Standard

Standard
ASTM B329-98 - Standard Test Method for Apparent Density of Metal Powders and Compounds Using the Scott Volumeter
English language
3 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


NOTICE: This standard has either been superceded and replaced by a new version or discontinued.
Contact ASTM International (www.astm.org) for the latest information.
Designation: B 329 – 98
Standard Test Method for
Apparent Density of Metal Powders and Compounds Using
the Scott Volumeter
This standard is issued under the fixed designation B 329; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
1. Scope 5. Apparatus
1.1 This test method covers determination of the apparent 5.1 Fig. 1 shows the Scott Volumeter consisting of the
density of metal powders and related compounds using the following parts:
Scott Volumeter, also known as the Paint Pigment Volumeter. 5.1.1 Top Brass Funnels—A large funnel with a 16-mesh
1.2 The values stated in SI units are to be regarded as the brass screen and a small conical funnel for directing the
standard. The values given in parentheses are for information powder into the baffle box (Note 2).
only. 5.1.2 Baffle Box—A box with two glass sides and two
1.3 This standard does not purport to address all of the wooden sides containing a series of four glass baffle plates.
safety concerns, if any, associated with its use. It is the
NOTE 1—The wooden baffle box may be substituted by a water-
responsibility of the user of this standard to establish appro-
resistant material if washing is more desirable than air cleaning.
priate safety and health practices and determine the applica-
5.1.3 Bottom Brass Funnel—A small brass funnel directly
bility of regulatory limitations prior to use.
beneath lower baffle box opening for directing the powder into
the density cup (Note 2).
2. Referenced Documents
5.1.4 Brass Density Cups—A cylindrical cup having a
2.1 ASTM Standards:
capacity of 25.00 6 0.03 cm , with an inside diameter of
B 215 Practices for Sampling Finished Lots of Metal Pow-
28.00 6 0.50 mm; or a square cup with a capacity of
ders
3 3
2 16.39 6 0.05 cm (1.000 6 0.003 in. ).
B 243 Terminology of Powder Metallurgy
B 873 Measuring Volume of Apparent Density Cup Used in
NOTE 2—Replacement parts for 5.1.1, 5.1.3, and 5.1.4 may be of
stainless steel.
Test Methods B 212, B 329 and B 417
5.1.5 Stand—A 90° pivoting wooden stand to support the
3. Terminology
funnels and the baffle box concentric with the density cup so
3.1 Definitions—For definitions of terms used in this test 3
that the bottom funnel lower opening is 19 mm ( ⁄4 in.) above
method see Terminology B 243.
the top of the density cup as shown in Fig. 1 when using the
cubic inch cup. Fig. 2 shows some suggested modifications for
4. Significance and Use
use of the metric cup. Modifications A and C of Fig. 2 are
4.1 This test method covers the evaluation of the apparent
suggested when the metric cup is to be used exclusively.
density physical characteristic of powders. The degree of
Modification B of Fig. 2 is suggested when both cups are to be
correlation between the results of this test and the quality of
used interchangeably.
powders in use will vary with each particular application and
5.2 Instrument Support—A stand or bench surface, level
has not been fully determined.
and vibration free.
4.2 The apparent density measured via this test method is
5.3 Balance—A balance having a capacity of at least 200 g
often referred to as the “Scott Density.”
and an accuracy of 60.05 g with full-range taring capability.
5.4 Brush—A good quality, 25.4-mm (1-in.) wide brush,
preferably nylon.
This test method is under the jurisdiction of ASTM Committee B-9 on Metal
Powders and Metal Powder Products and is the direct responsibility of Subcom-
mittee B09.03 on Refractory Metal Powders.
Apparatus may be purchased as the “Metal Powder Volumeter” (Catalog No.
Current edition approved March 10, 1998. Published May 1998. Originally
66062-620) from VWR Scientific Co., 1310 Goshen Parkway, West Chester, PA
published as B 329 – 58 T. Last previous edition B 329 – 95.
19380. The apparatus was formerly known as the “Scott, Schaeffer and White Paint
Annual Book of ASTM Standards, Vol 02.05.
Pigment Volumeter.”
Metric cup may be constructed or purchased from Alcan Powders and
Pigments, Division of Alcan Aluminum Corp., 901 Lehigh Ave., Union, NJ
07083-7632.
Copyright © ASTM, 100 Barr Harbor Drive, West Conshohocken, PA 19428-2959, United States.
NOTICE: This standard has either been superceded and replaced by a new version or discontinued.
Contact ASTM Interna
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.