ASTM C1405-04
(Specification)Standard Specification for Glazed Brick (Single Fired, Solid Brick Units)
Standard Specification for Glazed Brick (Single Fired, Solid Brick Units)
SCOPE
1.1 This specification covers brick, having a ceramic glaze finish fused to the body during the same process as the unit body firing, that are intended for use in masonry and supplying structural or facing components, or both, to the structure. This specification does not cover double-fired glazed brick. Some double-fired decorative glazes have physical properties which vary from those of single-fired glazes due to the lower temperatures used in applying the decorative coating.
1.2 The property requirements of this specification apply at the time of purchase. The use of results from testing of brick extracted from masonry structures for determining conformance or nonconformance to the property requirements of this specification is beyond the scope of this specification.
1.3 Glazed brick are prismatic units available in a variety of sizes, textures, colors, and shapes. Glazed brick are manufactured from clay, shale, or similar naturally occurring earthy substances and subjected to a heat treatment at elevated temperatures (firing). The heat treatment shall develop a fired bond between the particulate constituents to provide the strength and durability requirements of this specification (see firing, fired bond, glaze, and incipient fusion in Terminology C43).
1.4 Glazed brick are shaped during manufacture by molding, pressing, or extrusion, and the shaping method is a way to describe the brick.
1.5 Glazed brick are classified into one of two grades, one of two types, and one of two classes.
1.6 Opacity of the glaze is not required unless specified by the purchaser.
1.7 The text of this standard references notes and footnotes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of this standard.
1.8 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only.
1.9 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
General Information
Relations
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: C 1405 – 04
Standard Specification for
1
Glazed Brick (Single Fired, Brick Units)
This standard is issued under the fixed designation C1405; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
1. Scope* responsibility of the user of this standard to establish appro-
priate safety and health practices and determine the applica-
1.1 This specification covers brick, having a ceramic glaze
bility of regulatory limitations prior to use.
finish fused to the body during the same process as the unit
bodyfiring,thatareintendedforuseinmasonryandsupplying
2. Referenced Documents
structural or facing components, or both, to the structure. This
2
2.1 ASTM Standards:
specification does not cover double-fired glazed brick. Some
C43 Terminology of Structural Clay Products
double-fired decorative glazes have physical properties which
C67 Test Methods for Sampling and Testing Brick and
vary from those of single-fired glazes due to the lower
Structural Clay Tile
temperatures used in applying the decorative coating.
C1093 Practice for Accreditation of Testing Agencies for
1.2 The property requirements of this specification apply at
Unit Masonry
the time of purchase. The use of results from testing of brick
E84 Test Method for Surface Burning Characteristics of
extracted from masonry structures for determining conform-
Building Materials
ance or nonconformance to the property requirements of this
2.2 NFPA Standard:
specification is beyond the scope of this specification.
NFPA No. 255 Test for Surface Burning Characteristics of
1.3 Glazedbrickareprismaticunitsavailableinavarietyof
3
Building Materials
sizes, textures, colors, and shapes. Glazed brick are manufac-
2.3 UL Standard:
tured from clay, shale, or similar naturally occurring earthy
UL No. 723 Flammability Studies of Cellular Plastics and
substances and subjected to a heat treatment at elevated
4
Other Building Materials Used for Interior Finishes
temperatures (firing). The heat treatment shall develop a fired
2.4 ICBO Standard:
bond between the particulate constituents to provide the
UBC No. 42-1 Test Method for Fire Hazard Classification
strength and durability requirements of this specification (see
5
of Building Material
firing, fired bond, glaze, and incipient fusion in Terminology
2.5 Federal Standard:
C43).
Federal Standard Test No. 141 Abrasion Resistance (Taber
1.4 Glazed brick are shaped during manufacture by mold-
6
Abraser)
ing, pressing, or extrusion, and the shaping method is a way to
describe the brick.
3. Terminology
1.5 Glazedbrickareclassifiedintooneoftwogrades,oneof
3.1 Definitions—Termsusedinthisspecificationaredefined
two types, one of two classes, and one of three divisions.
in accordance with Terminology C43.
1.6 Opacity of the glaze is not required unless specified by
the purchaser.
4. Classification
1.7 The text of this standard references notes and footnotes
4.1 Grades—Gradesclassifyglazedbrickaccordingtotheir
whichprovideexplanatorymaterial.Thesenotesandfootnotes
permissible variation in face dimension as follows. When
(excluding those in tables and figures) shall not be considered
grade is not specified, the requirements for Grade S govern.
as requirements of this standard.
1.8 Thevaluesstatedininch-poundunitsaretoberegarded
2
as the standard. The values given in parentheses are for For referenced ASTM standards, visit the ASTM website, www.astm.org, or
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
information only.
Standards volume information, refer to the standard’s Document Summary page on
1.9 This standard does not purport to address all of the
the ASTM website.
3
safety concerns, if any, associated with its use. It is the
Available from the National Fire Protection Association, Batterymarch Park,
Quincy, MA 02269.
4
AvailablefromUnderwritersLaboratories,1285WaltWhitmanRoad,Melville,
1
This specification is under the jurisdiction of ASTM Committee C15 on NY 11747.
5
Manufactured Masonry Units and is the direct responsibility of Subcommittee Available from the International Conference of Building Officials, 5360 South
C15.02 on Brick and Structural Clay Tile. Workman Mill Road, Whittier, CA 90601.
6
CurrenteditionapprovedAugust1,2004.PublishedSeptember2004.Originally Available from Superintendent of Documents, U.S. Government Printing
approved in 1998. Last previous edition approved in 2002 C 1405–02. Office, Washington, DC 20402.
*A Summary of Changes section appears at the end of this standard.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1
-----
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.