Standard Specification for Asphalt Based Protection for Below-Grade Waterproofing

ABSTRACT
This specification covers the manufacture, testing, and physical requirements of two classes of asphalt based protection board used for protecting the integrity of below grade or below wearing surface waterproofing. Class A is made with asphalt saturated organic felt on the bottom and a coated or saturated non-woven glass felt on top, while Class B is made with glass fabrics both top and bottom. The boards shall be sampled for testing, and each class shall conform accordingly to specified individual values of the following physical properties: nominal thickness; puncture strength; water absorption; asphalt content; and resistance to decay.
SCOPE
1.1 This specification covers an asphalt based protection board used for protecting the integrity of below grade or below wearing surface waterproofing. The protection board protects the waterproofing system from backfill, surfacing, construction activities, and weathering conditions prior to backfilling or applying surfacing.
1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

General Information

Status
Historical
Publication Date
09-May-2001
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM D6506-01 - Standard Specification for Asphalt Based Protection for Below-Grade Waterproofing
English language
2 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: D 6506 – 01
Standard Specification for
Asphalt Based Protection Board for Below-Grade
Waterproofing
This standard is issued under the fixed designation D 6506; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
1. Scope 3.1.2 Class B, is made with glass fabrics both top and
bottom.
1.1 This specification covers an asphalt based protection
3.1.3 Classes A and B, each include three thicknesses of
board used for protecting the integrity of below grade or below
board. If desired, one side of each of these classes may be
wearing surface waterproofing. The protection board protects
covered with a thin plastic antistick sheet.
the waterproofing system from backfill, surfacing, construction
activities, and weathering conditions prior to backfilling or
4. Materials and Manufacture
applying surfacing.
4.1 The protection board shall be comprised of layers of
1.2 The values stated in SI units are to be regarded as the
asphalt and reinforcing mat. One surface of the board will be
standard. The values given in parentheses are for information
uniformly coated with a bituminous material for limited
only.
weather protection.
1.3 This standard does not purport to address all of the
4.2 Thelengthandwidthmeasurementsshallbeasspecified
safety concerns, if any, associated with its use. It is the
by the manufacturer. The tolerances of these dimensions
responsibility of the user of this standard to establish appro-
(length and width) shall be 66mm( ⁄4 in.)
priate safety and health practices and determine the applica-
4.3 The surfaces of the protection board shall be uniform
bility of regulatory limitations prior to use.
and free from defects such as cracks and indentations. The
2. Referenced Documents edges shall be uniform.
2.1 ASTM Standards:
5. Sampling
D 545 Test Methods for Preformed Expansion Joint Fillers
5.1 Each sample shall consist of sufficient material to
for Concrete Construction (Nonextruding and Resilient
2 provide at least five specimens for the tests listed in Section 7.
Types)
One representative sample shall be selected for each shipment
D 994 Specification for Preformed Expansion Joint Filler
2 of 10 000 ft or fraction thereof.
for Concrete (Bituminous Type)
D 5147 Test Methods for Sampling and Testing Modified
6. Physical Requirements
Bituminous Sheet Material
6.1 Nominal thicknesses of protection board are as follows:
E 154 Test Methods for Water Vapor Retarders Used in
6.1.1 Type 1, board is ⁄16 in.
Contact with Earth Under Concrete Slabs, on Walls, or as
6.1.2 Type 2, board is ⁄8 in.
Ground Cover
6.1.3 Type 3, board is ⁄4 in.
6.2 Class A protection board shall conform to the require-
3. Classification
ments in Table 1.
3.1 Two Classes of Product are Covered in This Specifica-
6.3 Class B protection board shall conform to the require-
tion:
ments in Table 2.
3.1.1 Class A, is made with asphalt saturated organic felt on
the bottom and a coated or saturated non-woven glass felt on
7. Test Methods
top.
7.1 Thickness—Determine the thickness of the specimen
using vernier calipers in accordance
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.