Specification for Engineering and Design Criteria for Rigid Wall Relocatable Structures

ABSTRACT
This specification covers engineering and design criteria for rigid wall relocatable structures (RWRSs) which shall be used for designing expandable and nonexpendable RWRSs. RWRSs shall be manufactured from recovered materials, wherein intimate contact of dissimilar materials shall not be allowed (to prevent galvanic corrosion), all components shall be adequately protected from corrosion, and the materials used shall not cause any skin irritation or injury to the person handling the material during transportation, operation, or maintenance of the equipment. Tests for compatibility, air transportability, ground mobility, rail transportability, forklift handling, erecting and striking, air tightness, blackout, humidity resistance, marine atmosphere, temperature, solar load, temperature shock, heat transfer, blowing sand, sunshine (ultraviolet effects), flame resistance, fungus resistance, squareness, panel flatness, roof loads, floor loads, door loads, panel attachment points, leveling devices, lifting and towing provision strength, tow and dragging simulator, flat and rotational drop (with or without skids), drop shock, impact resistance, electromagnetic interference provisions, water tightness, and lift shall be performed and shall conform to the requirements specified.
SCOPE
1.1 This specification covers engineering and design criteria required for the development of rigid wall relocatable structures (RWRS) and shall be applied to the design of expandable and nonexpandable RWRSs. This specification applies to present engineering and design requirements for effective RWRSs that are operable in a variety of environments without degradation and are capable of all specified transport modes. This specification shall be applied to the design of expandable and nonexpandable RWRSs. This specification is a conversion of a military standard that was approved by all departments and agencies of the Department of Defense.  
1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.  
1.3 The following safety hazards caveat pertains only to the test required portion, Section 10, of this specification. This specification does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this specification to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

General Information

Status
Published
Publication Date
30-Sep-2018
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM E1925-18 - Specification for Engineering and Design Criteria for Rigid Wall Relocatable Structures
English language
13 pages
sale 15% off
Preview
sale 15% off
Preview
Technical specification
REDLINE ASTM E1925-18 - Specification for Engineering and Design Criteria for Rigid Wall Relocatable Structures
English language
13 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the
Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Designation:E1925 −18
Specification for
Engineering and Design Criteria for Rigid Wall Relocatable
1
Structures
This standard is issued under the fixed designation E1925; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the U.S. Department of Defense.
1. Scope 2. Referenced Documents
2
1.1 Thisspecificationcoversengineeringanddesigncriteria 2.1 ASTM Standards:
required for the development of rigid wall relocatable struc- E631Terminology of Building Constructions
tures(RWRS)andshallbeappliedtothedesignofexpandable E1749Terminology Relating to Rigid Wall Relocatable
and nonexpandable RWRSs. This specification applies to Shelters
E1851Test Method for Electromagnetic Shielding Effec-
present engineering and design requirements for effective
RWRSs that are operable in a variety of environments without tiveness of Durable Rigid Wall Relocatable Structures
degradation and are capable of all specified transport modes. G21Practice for Determining Resistance of Synthetic Poly-
meric Materials to Fungi
This specification shall be applied to the design of expandable
and nonexpandable RWRSs. This specification is a conversion 3
2.2 ISO Standards:
ofamilitarystandardthatwasapprovedbyalldepartmentsand
ISO668-1995Series 1 Freight Containers - Classification,
agencies of the Department of Defense.
Dimensions and Ratings, 5th Edition
ISO1161-1990Series1FreightContainers-CornerFittings
1.2 Thevaluesstatedininch-poundunitsaretoberegarded
ISO1496-1Series 1 Freight Containers Specification and
as standard. The values given in parentheses are mathematical
Testing Document - Part 1, 1993
conversions to SI units that are provided for information only
ISO1496-2Series 1 Freight Containers Specification and
and are not considered standard.
Testing Document - Part 2, 1993
1.3 The following safety hazards caveat pertains only to the
4
2.3 Military Standards:
test required portion, Section 10, of this specification. This
MIL-STD-1472DNotice3,HumanEngineeringDesignCri-
specification does not purport to address all of the safety
teria for Military Systems, Equipment and Facilities
concerns, if any, associated with its use. It is the responsibility
MIL-F-14072DFinishes for Ground Electronic Equipment
of the user of this specification to establish appropriate safety,
MIL-C-22992E Amend 5, Connector, Plugs and
health, and environmental practices and determine the appli-
Receptacles, Electrical, Waterproof, Quick Disconnect,
cability of regulatory limitations prior to use.
Heavy Duty Type General Specification for
1.4 This international standard was developed in accor-
MIL-STD-810Environmental Engineering Considerations
dance with internationally recognized principles on standard-
and Laboratory Test
ization established in the Decision on Principles for the
MIL-STD-1791Notice 1, Designing for InternalAerial De-
Development of International Standards, Guides and Recom-
livery in Fixed Wing Aircraft
mendations issued by the World Trade Organization Technical
Barriers to Trade (TBT) Committee.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
1
This specification is under the jurisdiction of ASTM Committee E06 on Standards volume information, refer to the standard’s Document Summary page on
Performance of Buildings and is under the direct responsibility of Subcommittee the ASTM website.
3
E06.53 on Materials and Processes for Durable Rigidwall Relocatable Structures. Available fromAmerican National Standards Institute (ANSI), 25 W. 43rd St.,
Current edition approved Oct. 1, 2018. Published November 2018. Originally 4th Floor, New York, NY 10036, http://www.ansi.org.
4
approved in 1997. Last previous edition approved in 2010 as E1925–10. DOI: Available from DLA Document Services, Building 4/D, 700 Robbins Ave.,
10.1520/E1925–18. Philadelphia, PA 19111-5094, http://quicksearch.dla.mil.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
E1925−18
5
2.4 SAE Standard: shall also be directed toward minimizing the man-hours
SAE-AS8090 Mobility, Towed Aerospace Ground required to strike or erect RWRSs using common hand tools.
Equipment, General Requirements for
5.2 Standardization—The design and engineering require-
ments specified herei
...

This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: E1925 − 10 E1925 − 18
Specification for
Engineering and Design Criteria for Rigid Wall Relocatable
1
Structures
This standard is issued under the fixed designation E1925; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the U.S. Department of Defense.
1. Scope
1.1 This specification covers engineering and design criteria required for the development of rigid wall relocatable structures
(RWRS) and shall be applied to the design of expandable and nonexpandable RWRSs. This specification applies to present
engineering and design requirements for effective RWRSs that are operable in a variety of environments without degradation and
are capable of all specified transport modes. This specification shall be applied to the design of expandable and nonexpandable
RWRSs. This specification is a conversion of a military standard that was approved by all departments and agencies of the
Department of Defense.
1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical
conversions to SI units that are provided for information only and are not considered standard.
1.3 The following safety hazards caveat pertains only to the test required portion, Section 10, of this specification. This
specification does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the
user of this specification to establish appropriate safety safety, health, and healthenvironmental practices and determine the
applicability of regulatory limitations prior to use.
1.4 This international standard was developed in accordance with internationally recognized principles on standardization
established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued
by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
2. Referenced Documents
2
2.1 ASTM Standards:
E631 Terminology of Building Constructions
E1749 Terminology Relating to Rigid Wall Relocatable Shelters
E1851 Test Method for Electromagnetic Shielding Effectiveness of Durable Rigid Wall Relocatable Structures
G21 Practice for Determining Resistance of Synthetic Polymeric Materials to Fungi
3
2.2 ISO Standards:
ISO 668-1995 Series 1 Freight Containers - Classification, Dimensions and Ratings, 5th Edition
ISO 1161-1990 Series 1 Freight Containers - Corner Fittings
ISO 1496-1 Series 1 Freight Containers Specification and Testing Document - Part 1, 1993
ISO 1496-2 Series 1 Freight Containers Specification and Testing Document - Part 2, 1993
4
2.3 Military Standards:
MIL-STD-1472D Notice 3, Human Engineering Design Criteria for Military Systems, Equipment and Facilities
MIL-F-14072D Finishes for Ground Electronic Equipment
MIL-C-22992E Amend 5, Connector, Plugs and Receptacles, Electrical, Waterproof, Quick Disconnect, Heavy Duty Type
General Specification for
1
This specification is under the jurisdiction of ASTM Committee E06 on Performance of Buildings and is under the direct responsibility of Subcommittee E06.53 on
Materials and Processes for Durable Rigidwall Relocatable Structures.
Current edition approved Oct. 1, 2010Oct. 1, 2018. Published October 2010November 2018. Originally approved in 1997. Last previous edition approved in 20042010
as E1925 – 04.E1925–10. DOI: 10.1520/E1925-10.10.1520/E1925–18.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
3
Available from American National Standards Institute (ANSI), 25 W. 43rd St., 4th Floor, New York, NY 10036, http://www.ansi.org.
4
Available from Standardization Documents Order Desk, DODSSP, Bldg. 4, Section D, DLA Document Services, Building 4/D, 700 Robbins Ave., Philadelphia, PA
19111-5098, http://dodssp.daps.dla.mil.19111-5094, http://quicksearch.dla.mil.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
E1925 − 18
MIL-STD-810 Environmental Engineering Considerations and Laboratory Test
MIL-STD-1791 No
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.