SCOPE
1.1 This specification covers the manufacture and acceptance of precast concrete pipe designed to conform to the owner's design requirements and to the ASCE 15-93 or an equivalent design specification.
Note 1—The section on evaluation of core test results (14.3.3) and the Appendix are currently being reballoted.
1.2 This specification is the SI companion to Specification C 1417.
General Information
Relations
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Please contact ASTM International (www.astm.org) for the latest information.
Designation: C 1417M – 03
Standard Specification for
Manufacture of Reinforced Concrete Sewer, Storm Drain,
1
and Culvert Pipe for Direct Design [Metric]
This standard is issued under the fixed designation C 1417M; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (ϵ) indicates an editorial change since the last revision or reapproval.
1. Scope C 595 Specification for Blended Hydraulic Cements (Met-
2
ric)
1.1 This specification covers the manufacture and accep-
C 618 Specification for Coal Fly Ash and Raw or Calcined
tance of precast concrete pipe designed to conform to the
Natural Pozzolan for Use as a Mineral Admixture in
owner’s design requirements and to the ASCE 15-93 or an
3
Portland Cement Concrete
equivalent design specification.
C 655 Specification for Reinforced Concrete D-Load Cul-
NOTE 1—The section on evaluation of core test results (14.3.3) and the 4
vert, Storm Drain, and Sewer Pipe
Appendix are currently being reballoted.
C 822 Terminology Relating to Concrete Pipe and Related
4
1.2 This specification is the SI companion to Specification
Products
C 1417.
2.2 Other Standards:
ASCE 15-93 Standard Practice for the Direct Design of
2. Referenced Documents
Buried Precast Reinforced Concrete Pipe Using Standard
5
2.1 ASTM Standards:
Installations (SIDD)
A82 Specification for Steel Wire, Plain, for Concrete Re-
ACI 318 Building Code Requirements for Reinforced Con-
2
6
inforcement
crete
A 185 SpecificationforSteelWeldedWireFabric,Plain,for
2
3. Terminology
Concrete Reinforcement
A 496 Specification for Steel Wire, Deformed, for Concrete
3.1 Definitions:
2
Reinforcement
3.1.1 For definitions of terms relating to concrete pipe, see
A 497 Specification for Steel Welded Wire Fabric, De-
Terminology C 822C 822.
2
formed, for Concrete Reinforcement
3.1.2 group of pipe sections—each day’s production run of
A 615/A 615M Specification for Deformed and Plain
pipesectionsofasingleconcretestrengthforaspecificproject.
2
Billet-Steel Bars for Concrete Reinforcement
3.1.3 lot of pipe sections—total of the number of groups of
C31 Practice for Making and Curing Concrete Test Speci-
pipe sections of a single concrete strength produced for a
3
mens in the Field
specific project.
3
C33 Specification for Concrete Aggregates
3.1.4 running average—average concrete compressive
C39 Test Method for Compressive Strength of Cylindrical
strength of all groups of pipe sections of a single concrete
3
Concrete Specimens
strength produced for a specific project, generally determined
C76 Specification for Reinforced Concrete Culvert, Storm
as each group is tested.
4
Drain, and Sewer Pipe
2
4. Basis of Acceptance of Design
C 150 Specification for Portland Cement
C 309 Specification for Liquid Membrane-Forming Com-
4.1 Manufacturing Design Data—The manufacturer shall
3
pound for Curing Concrete
submit the following manufacturing design data for the con-
C 497 Test Methods for Concrete Pipe, Manhole Sections,
crete pipe to the owner for approval.
4
or Tile
4.1.1 Pipe wall thickness.
4.1.2 Concrete strength.
4.1.3 Reinforcement:
1
4.1.3.1 Specification,
This specification is under the jurisdiction of ASTM Committee C13 on
Concrete Pipe and is the direct responsibility of Subcommittee C13.05 on Least
Cost Analysis.
Current edition approved February 10, 2003. Published June 2003. Originally
5
approved in 1998. Last previous edition approved in 2000 as C 1417M–00. Available from American Society of Civil Engineers, 345 E. 45th Street, New
2
Annual Book of ASTM Standards, Vol 01.04. York, NY 10017–2398.
3 6
Annual Book of ASTM Standards, Vol 04.02. Available from American Concrete Institute, P.O. Box 19150, Detroit, MI
4
Annual Book of ASTM Standards, Vol 04.05. 48219.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1
---------------------- Page: 1 ----------------------
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Please contact ASTM International (www.astm.org) for the latest information.
C 1417M – 03
4.1.3.2 Reinforcement Type 1, 2, or 3, where: 6.2.3.4 A combination of portland cement and fly ash or
pozzolan, wherein the proportion of fly ash is between 5 and
Type 1: Smooth wire or plain bars
Type 2: Welded smooth wire fabric, 200 mm maximum spacing of
25 % by weight (mass) of total cementitious material (portland
longitudinals
cement plus fly ash).
Type 3: Welded deformed wire fabric, deformed wire, deformed
6.3 Aggregates—Aggregates shall conform to the require-
bars, or any reinforcement with stirrups, anchored thereto
ments of Specification C 33C33, except that the requirement
4.1.3.3 Design yiel
...