Standard Specification for Thermoplastic Polyethylene Jacket for Electrical Wire and Cable

ABSTRACT
This specification covers a thermoplastic jacketing compound substantially consisting of pigmented polyethylene for use in electrical wires and cables with specified nominal thicknesses and operating at specified voltages. Since the jacket material cannot be tested unless it has been formed around a conductor or cable, tests shall then be done on jacketed wires and cables solely to determine the relevant property of the jacket material and not to test the jacketed conductor or completed cable. Materials shall be suitably sampled and tested, and shall conform accordingly to the following physical and electrical properties: unaged tensile strength and elongation at rupture; tensile strength and elongation at rupture after air oven aging; absorption coefficient; heat distortion; environmental stress-cracking; surface resistivity; and U-bend discharge.
SCOPE
1.1 This specification covers a thermoplastic jacketing compound for 2 to 35 kV wire and cable, of at least 0.030 in. (0.76 mm) nominal thickness, consisting substantially of pigmented polyethylene.  
1.2 In many instances the jacket material cannot be tested unless it has been formed around a conductor or cable. Therefore, tests done on jacketed wire and cable in this specification are solely to determine the relevant property of the jacket material and not to test the jacketed conductor or completed cable.  
1.3 Whenever two sets of values are presented, in different units, the values in the first set are the standard, while those in parentheses are for information only.  
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

General Information

Status
Published
Publication Date
31-Jul-2020
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM D2308-07(2020)e1 - Standard Specification for Thermoplastic Polyethylene Jacket for Electrical Wire and Cable
English language
2 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the
Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
´1
Designation:D2308 −07 (Reapproved 2020)
Standard Specification for
Thermoplastic Polyethylene Jacket for Electrical Wire and
Cable
This standard is issued under the fixed designation D2308; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
ε NOTE—Editorially corrected Table 2 October 2020.
1. Scope D3349Test Method for Absorption Coefficient of Ethylene
Polymer Material Pigmented with Carbon Black
1.1 Thisspecificationcoversathermoplasticjacketingcom-
pound for 2 to 35 kVwire and cable, of at least 0.030 in. (0.76
3. Terminology
mm) nominal thickness, consisting substantially of pigmented
polyethylene. 3.1 Definitions:
3.1.1 Refer to Terminology D1711 for definitions of terms
1.2 In many instances the jacket material cannot be tested
used in this specification.
unless it has been formed around a conductor or cable.
3.2 Definitions of Terms Specific to This Standard:
Therefore, tests done on jacketed wire and cable in this
3.2.1 aging, (act of), n—exposure of materials to air at 100
specification are solely to determine the relevant property of
the jacket material and not to test the jacketed conductor or °C for either 24 or 48 h.
completed cable.
4. Physical Properties
1.3 Whenever two sets of values are presented, in different
units, the values in the first set are the standard, while those in
4.1 The polyethylene before application to the wire or cable
parentheses are for information only.
shall comply with the requirements for Type I, Class C,
Category 4 or 5, Grade E5 or J3 of Specification D1248,or
1.4 This international standard was developed in accor-
Class B with equivalent weathering requirements to Class C
dance with internationally recognized principles on standard-
materials. The requirements of Specification D1248 shall not
ization established in the Decision on Principles for the
apply to the jacket removed from the wire or cable. The
Development of International Standards, Guides and Recom-
compound is suitable for exposure to sunlight and other
mendations issued by the World Trade Organization Technical
atmospheric environments at temperatures between −55
Barriers to Trade (TBT) Committee.
and+75 °C, and a minimum installation temperature of−40
2. Referenced Documents
°C.
2.1 ASTM Standards:
4.2 Specimensremovedfromthewireorcableandtestedat
D1248Specification for Polyethylene Plastics Extrusion
20to28°C(68to82°F)shallconformtotherequirementsfor
Materials for Wire and Cable
physical properties specified in Table 1. Alternatively, the
D1693Test Method for Environmental Stress-Cracking of
jacket shall be air-oven aged without removal from the
Ethylene Plastics
conductor.
D1711Terminology Relating to Electrical Insulation
4.3 Environmental Stress-Cracking Test—The jacket shall
D2633Test Methods for Thermoplastic Insulations and
conform to the requirements for Grade E5 as specified in
Jackets for Wire and Cable
Table3 of Specification D1248.
4.4 Absorption Coeffıcient—See Test Method D3349. In-
This specification is under the jurisdiction of ASTM Committee D09 on
stead of testing the jacket removed from the conductors, a
Electrical and Electronic Insulating Materials and is the direct responsibility of
Subcommittee D09.07 on Electrical Insulating Materials. certification by the polyethylene compound manufacturer that
Current edition approved Aug. 1, 2020. Published September 2020. Originally
this requirement has been complied with shall suffice.
approved in 1964. Last previous edition approved in 2007 as D2308 – 07 (2013).
DOI: 10.1520/D2308-20E02.
2 5. Electrical Properties
For referenced ASTM standards, vi
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.