ASTM A213/A213M-11
(Specification)Standard Specification for Seamless Ferritic and Austenitic Alloy-Steel Boiler, Superheater, and Heat-Exchanger Tubes
Standard Specification for Seamless Ferritic and Austenitic Alloy-Steel Boiler, Superheater, and Heat-Exchanger Tubes
ABSTRACT
This specification covers seamless ferritic and austenitic steel boiler, superheater, and heat-exchanger tubes. Grades containing the letter H in their designation have requirements different from those of similar grades not containing the letter H. These different requirements provide higher creep-rupture strength than normally achievable in similar grades without these different requirements. The tubes shall be made by the seamless process and shall be either hot finished or cold finished, as specified. Grade TP347HFG shall be cold finished. Heat treatment shall be done separately and in addition to heating for hot forming. The ferritic alloy and ferritic stainless steels shall be reheated. On the other hand, austenitic stainless steel tubes shall be furnished in the heat-treated condition. Alternatively, immediately after hot forming, while the temperature of the tubes is not less than the minimum solution temperature, tubes may be individually quenched in water or rapidly cooled by other means. Tension test, hardness test, flattening test, and flaring test shall be done to each tube. Also, each tube shall be subjected to the nondestructive electric test or hydrostatic test.
SCOPE
1.1 This specification covers seamless ferritic and austenitic steel boiler, superheater, and heat-exchanger tubes, designated Grades T5, TP304, etc. These steels are listed in Tables 1 and 2.
1.2 Grades containing the letter, H, in their designation, have requirements different from those of similar grades not containing the letter, H. These different requirements provide higher creep-rupture strength than normally achievable in similar grades without these different requirements.
1.3 The tubing sizes and thicknesses usually furnished to this specification are 1/8 in. [3.2 mm] in inside diameter to 5 in. [127 mm] in outside diameter and 0.015 to 0.500 in. [0.4 to 12.7 mm], inclusive, in minimum wall thickness or, if specified in the order, average wall thickness. Tubing having other diameters may be furnished, provided such tubes comply with all other requirements of this specification.
1.4 The values stated in either SI units or inch-pound units are to be regarded separately as standard. Within the text, the SI units are shown in brackets. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard. The inch-pound units shall apply unless the “M” designation of this specification is specified in the order.
General Information
Relations
Buy Standard
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Used in USDOE-NE standards
Designation: A213/A213M – 11
Standard Specification for
Seamless Ferritic and Austenitic Alloy-Steel Boiler,
1
Superheater, and Heat-Exchanger Tubes
This standard is issued under the fixed designationA213/A213M; the number immediately following the designation indicates the year
of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval.
A superscript epsilon (ϵ) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
1. Scope* Attack in Austenitic Stainless Steels
2 A941 Terminology Relating to Steel, Stainless Steel, Re-
1.1 This specification covers seamless ferritic and auste-
lated Alloys, and Ferroalloys
nitic steel boiler, superheater, and heat-exchanger tubes, des-
A1016/A1016M Specification for General Requirements
ignated GradesT5,TP304, etc.These steels are listed inTables
for Ferritic Alloy Steel, Austenitic Alloy Steel, and Stain-
1 and 2.
less Steel Tubes
1.2 Grades containing the letter, H, in their designation,
E112 Test Methods for Determining Average Grain Size
have requirements different from those of similar grades not
containing the letter, H. These different requirements provide
3. Terminology
higher creep-rupture strength than normally achievable in
3.1 Definitions—For definitions of terms used in this speci-
similar grades without these different requirements.
fication, refer to Terminology A941.
1.3 The tubing sizes and thicknesses usually furnished to
1
this specification are ⁄8 in. [3.2 mm] in inside diameter to 5 in.
4. Ordering Information
[127 mm] in outside diameter and 0.015 to 0.500 in. [0.4 to
4.1 It shall be the responsibility of the purchaser to specify
12.7 mm], inclusive, in minimum wall thickness or, if specified
all requirements that are necessary for products under this
in the order, average wall thickness. Tubing having other
specification. Such requirements to be considered include, but
diameters may be furnished, provided such tubes comply with
are not limited to, the following:
all other requirements of this specification.
4.1.1 Quantity (feet, metres, or number of lengths),
1.4 The values stated in either SI units or inch-pound units
4.1.2 Name of material (seamless tubes),
are to be regarded separately as standard. Within the text, the
4.1.3 Grade (Tables 1 and 2),
SI units are shown in brackets. The values stated in each
4.1.4 Condition (hot finished or cold finished),
system may not be exact equivalents; therefore, each system
4.1.5 Controlled structural characteristics (see 6.3),
shall be used independently of the other. Combining values
4.1.6 Size (outside diameter and minimum wall thickness,
from the two systems may result in non-conformance with the
unless average wall thickness is specified),
standard. The inch-pound units shall apply unless the “M”
4.1.7 Length (specific or random),
designation of this specification is specified in the order.
4.1.8 Hydrostatic Test or Nondestructive Electric Test (see
10.1),
2. Referenced Documents
3 4.1.9 Specification designation and year of issue,
2.1 ASTM Standards:
4.1.10 Increasedsulfur(formachinability,seeNoteB,Table
A262 Practices for Detecting Susceptibility to Intergranular
1, and 15.3), and
4.1.11 Special requirements and any supplementary require-
ments selected.
1
This specification is under the jurisdiction of ASTM Committee A01 on Steel,
Stainless Steel and RelatedAlloys and is the direct responsibility of Subcommittee
5. General Requirements
A01.10 on Stainless and Alloy Steel Tubular Products.
Current edition approved April 1, 2011. Published April 2011. Originally
5.1 Product furnished to this specification shall conform to
approved in 1939. Last previous edition approved in 2010 as A213/A213M–10a.
the requirements of Specification A1016/A1016M, including
DOI: 10.1520/A0213_A0213M-11.
2
any supplementary requirements that are indicated in the
For ASME Boiler and Pressure Vessel Code applications see related Specifi-
cation SA-213 in Section II of that Code.
purchase order. Failure to comply with the general require-
3
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
ments of Specification A1016/A1016M constitutes nonconfor-
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
mance with this specification. In case of conflict between the
Standards volume information, refer to the standard’s Document Summary page on
the ASTM website.
*A Summary of Changes section appears at the end of this standard.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1
---------------------- Page: 1 ----------------------
A213/A213M – 11
2
A
TABLE 1 Chemical Composition Limi
...
This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Used in USDOE-NE standards
Designation:A213/A213M–10a Designation: A213/A213M – 11
Standard Specification for
Seamless Ferritic and Austenitic Alloy-Steel Boiler,
1
Superheater, and Heat-Exchanger Tubes
This standard is issued under the fixed designationA213/A213M; the number immediately following the designation indicates the year
of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval.
A superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
1. Scope*
2
1.1 This specification covers seamless ferritic and austenitic steel boiler, superheater, and heat-exchanger tubes, designated
Grades T5, TP304, etc. These steels are listed in Tables 1 and 2.
1.2 Grades containing the letter, H, in their designation, have requirements different from those of similar grades not containing
theletter,H.Thesedifferentrequirementsprovidehighercreep-rupturestrengththannormallyachievableinsimilargradeswithout
these different requirements.
1
1.3 The tubing sizes and thicknesses usually furnished to this specification are ⁄8 in. [3.2 mm] in inside diameter to 5 in. [127
mm] in outside diameter and 0.015 to 0.500 in. [0.4 to 12.7 mm], inclusive, in minimum wall thickness or, if specified in the order,
average wall thickness. Tubing having other diameters may be furnished, provided such tubes comply with all other requirements
of this specification.
1.4 ThevaluesstatedineitherSIunitsorinch-poundunitsaretoberegardedseparatelyasstandard.Withinthetext,theSIunits
are shown in brackets. The values stated in each system may not be exact equivalents; therefore, each system shall be used
independently of the other. Combining values from the two systems may result in non-conformance with the standard. The
inch-pound units shall apply unless the “M” designation of this specification is specified in the order.
2. Referenced Documents
3
2.1 ASTM Standards:
A262 Practices for Detecting Susceptibility to Intergranular Attack in Austenitic Stainless Steels
A941 Terminology Relating to Steel, Stainless Steel, Related Alloys, and Ferroalloys
A1016/A1016M Specification for General Requirements for Ferritic Alloy Steel, Austenitic Alloy Steel, and Stainless Steel
Tubes
E112 Test Methods for Determining Average Grain Size
3. Terminology
3.1 Definitions—For definitions of terms used in this specification, refer to Terminology A941.
4. Ordering Information
4.1 It shall be the responsibility of the purchaser to specify all requirements that are necessary for products under this
specification. Such requirements to be considered include, but are not limited to, the following:
4.1.1 Quantity (feet, metres, or number of lengths),
4.1.2 Name of material (seamless tubes),
4.1.3 Grade (Tables 1 and 2),
4.1.4 Condition (hot finished or cold finished),
4.1.5 Controlled structural characteristics (see 6.3),
4.1.6 Size (outside diameter and minimum wall thickness, unless average wall thickness is specified),
4.1.7 Length (specific or random),
1
This specification is under the jurisdiction ofASTM CommitteeA01 on Steel, Stainless Steel and RelatedAlloys and is the direct responsibility of SubcommitteeA01.10
on Stainless and Alloy Steel Tubular Products.
Current edition approved Oct.April 1, 2010.2011. Published November 2010.April 2011. Originally approved in 1939. Last previous edition approved in 2010 as
A213/A213M–10a. DOI: 10.1520/A0213_A0213M-10a1.
2
For ASME Boiler and Pressure Vessel Code applications see related Specification SA-213 in Section II of that Code.
3
For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
*A Summary of Changes section appears at the end of this standard.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1
---------------------- Page: 1 ----------------------
A213/A213M – 11
2
A
TABLE 1 Chemical Composition Limits, % , for Low Alloy Steel
UNS
Grade Composition, %
Designation
Carbon Manga- Phospho- Sul- Silicon Nickel Chromium Molybdenum Vana- Boron Niobium Nitrogen Aluminum Tungsten Other
nese rus fur dium Elements
B
T2 K11547 0.10–0.20 0.30–0.61 0.025 0.025 0.10–0.30 . 0.50–0.81 0.44–0.65 . . . . . . .
T5 K41545 0.15 0.30–0.60 0.025 0.025 0.50 . 4.0
...
This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Used in USDOE-NE standards
Designation:A213/A213M–10a Designation: A213/A213M – 11
Standard Specification for
Seamless Ferritic and Austenitic Alloy-Steel Boiler,
1
Superheater, and Heat-Exchanger Tubes
This standard is issued under the fixed designationA213/A213M; the number immediately following the designation indicates the year
of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval.
A superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
1. Scope*
2
1.1 This specification covers seamless ferritic and austenitic steel boiler, superheater, and heat-exchanger tubes, designated
Grades T5, TP304, etc. These steels are listed in Tables 1 and 2.
1.2 Grades containing the letter, H, in their designation, have requirements different from those of similar grades not containing
theletter,H.Thesedifferentrequirementsprovidehighercreep-rupturestrengththannormallyachievableinsimilargradeswithout
these different requirements.
1
1.3 The tubing sizes and thicknesses usually furnished to this specification are ⁄8 in. [3.2 mm] in inside diameter to 5 in. [127
mm] in outside diameter and 0.015 to 0.500 in. [0.4 to 12.7 mm], inclusive, in minimum wall thickness or, if specified in the order,
average wall thickness. Tubing having other diameters may be furnished, provided such tubes comply with all other requirements
of this specification.
1.4 ThevaluesstatedineitherSIunitsorinch-poundunitsaretoberegardedseparatelyasstandard.Withinthetext,theSIunits
are shown in brackets. The values stated in each system may not be exact equivalents; therefore, each system shall be used
independently of the other. Combining values from the two systems may result in non-conformance with the standard. The
inch-pound units shall apply unless the “M” designation of this specification is specified in the order.
2. Referenced Documents
3
2.1 ASTM Standards:
A262 Practices for Detecting Susceptibility to Intergranular Attack in Austenitic Stainless Steels
A941 Terminology Relating to Steel, Stainless Steel, Related Alloys, and Ferroalloys
A1016/A1016M Specification for General Requirements for Ferritic Alloy Steel, Austenitic Alloy Steel, and Stainless Steel
Tubes
E112 Test Methods for Determining Average Grain Size
3. Terminology
3.1 Definitions—For definitions of terms used in this specification, refer to Terminology A941.
4. Ordering Information
4.1 It shall be the responsibility of the purchaser to specify all requirements that are necessary for products under this
specification. Such requirements to be considered include, but are not limited to, the following:
4.1.1 Quantity (feet, metres, or number of lengths),
4.1.2 Name of material (seamless tubes),
4.1.3 Grade (Tables 1 and 2),
4.1.4 Condition (hot finished or cold finished),
4.1.5 Controlled structural characteristics (see 6.3),
4.1.6 Size (outside diameter and minimum wall thickness, unless average wall thickness is specified),
4.1.7 Length (specific or random),
1
This specification is under the jurisdiction ofASTM CommitteeA01 on Steel, Stainless Steel and RelatedAlloys and is the direct responsibility of SubcommitteeA01.10
on Stainless and Alloy Steel Tubular Products.
Current edition approved Oct.April 1, 2010.2011. Published November 2010.April 2011. Originally approved in 1939. Last previous edition approved in 2010 as
A213/A213M–10a. DOI: 10.1520/A0213_A0213M-10a1.
2
For ASME Boiler and Pressure Vessel Code applications see related Specification SA-213 in Section II of that Code.
3
For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
*A Summary of Changes section appears at the end of this standard.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1
---------------------- Page: 1 ----------------------
A213/A213M – 11
2
A
TABLE 1 Chemical Composition Limits, % , for Low Alloy Steel
UNS
Grade Composition, %
Designation
Carbon Manga- Phospho- Sul- Silicon Nickel Chromium Molybdenum Vana- Boron Niobium Nitrogen Aluminum Tungsten Other
nese rus fur dium Elements
B
T2 K11547 0.10–0.20 0.30–0.61 0.025 0.025 0.10–0.30 . 0.50–0.81 0.44–0.65 . . . . . . .
T5 K41545 0.15 0.30–0.60 0.025 0.025 0.50 . 4.0
...