Standard Test Method for Potential Expansion of Portland-Cement Mortars Exposed to Sulfate

SIGNIFICANCE AND USE
This test method is used primarily by those interested in research on methods for determining the potential sulfate resistance of portland cement. This test method is also used to establish that a sulfate-resisting portland cement meets the performance requirements of Specification C 150.
SCOPE
1.1 This test method, which is applicable only to portland cements, covers the determination of the expansion of mortar bars made from a mixture of portland cement and gypsum in such proportions that the mixture has a sulfur trioxide (SO3) content of 7.0 mass %.
1.2 The values stated in SI units (IEEE/ASTM SI-10) are to be regarded as the standard.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Warning-Fresh hydraulic cementitious mixtures are caustic and may cause chemical burns to skin and tissue upon prolonged exposure.

General Information

Status
Historical
Publication Date
14-May-2006
Technical Committee
Drafting Committee
Current Stage
Ref Project

Relations

Buy Standard

Standard
ASTM C452-06 - Standard Test Method for Potential Expansion of Portland-Cement Mortars Exposed to Sulfate
English language
3 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: C452 – 06
Standard Test Method for
Potential Expansion of Portland-Cement
1
Mortars Exposed to Sulfate
This standard is issued under the fixed designation C452; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope* C490 Practice for Use of Apparatus for the Determination
of Length Change of Hardened Cement Paste, Mortar, and
1.1 This test method, which is applicable only to portland
Concrete
cements, covers the determination of the expansion of mortar
C511 Specification for Mixing Rooms, Moist Cabinets,
bars made from a mixture of portland cement and gypsum in
Moist Rooms, and Water Storage Tanks Used in the
such proportions that the mixture has a sulfur trioxide (SO )
3
Testing of Hydraulic Cements and Concretes
content of 7.0 mass %.
C778 Specification for Sand
1.2 The values stated in SI units (IEEE/ASTM SI 10) are to
C1005 Specification for Reference Masses and Devices for
be regarded as the standard.
Determining Mass and Volume for Use in the Physical
1.3 This standard does not purport to address all of the
Testing of Hydraulic Cements
safety concerns, if any, associated with its use. It is the
D1193 Specification for Reagent Water
responsibility of the user of this standard to establish appro-
IEEE/ASTM SI 10 Practice for Use of the International
priate safety and health practices and determine the applica-
System of Units (SI): The Modern Metric System
bility of regulatory limitations prior to use.
Warning—Fresh hydraulic cementitious mixtures are caus-
3. Significance and Use
tic and may cause chemical burns to skin and tissue upon
2
3.1 This test method is used primarily by those interested in
prolonged exposure.
research on methods for determining the potential sulfate
2. Referenced Documents resistance of portland cement. This test method is also used to
3
establish that a sulfate-resisting portland cement meets the
2.1 ASTM Standards:
performance requirements of Specification C150.
C109/C109M Test Method for Compressive Strength of
Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube
4. Apparatus
Specimens)
4.1 Weights and Weighing Devices, conforming to the re-
C150 Specification for Portland Cement
quirements of Specification C1005.
C230/C230M Specification for Flow Table for Use in Tests
4.2 Flow Table, conforming to the requirements of Specifi-
of Hydraulic Cement
cation C230/C230M.
C305 Practice for Mechanical Mixing of Hydraulic Cement
4.3 Mixer, Bowl, and Paddle, conforming to the require-
Pastes and Mortars of Plastic Consistency
ments of Practice C305.
C471M Test Methods for Chemical Analysis of Gypsum
4.4 Trowel and Tamper, conforming to the requirements of
and Gypsum Products (Metric)
Test Method C109/C109M.
4.5 Glass Graduates, Molds, and Length Comparator, con-
1
forming to the requirements of Practice C490.
This test method is under the jurisdiction ofASTM Committee C01 on Cement
and is the direct responsibility of Subcommittee C01.29 on Sulfate Resistance.
Current edition approved May 15, 2006. Published June 2006. Originally 5. Temperature and Humidity
approved in 1960. Last previous edition approved in 2002 as C452 – 02. DOI:
5.1 Molding Room, Dry Materials, and Mixing Water—
10.1520/C0452-06.
2
Maintain the temperature of the molding room, dry materials,
Section on Safety, Manual of Cement Testing, Annual Book of ASTM
Standards, Vol 04.01.
and mixing water at 23.0 6 4.0 °C (73.5 6 7 °F) and the
3
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
relative humidity of the molding room at not less than 50 %.
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
5.2 MoistCabinetorRoom, conforming to the requirements
Standards volume information, refer to the standard’s Document Summary page on
the ASTM website. of Specification C511.
*A Summary of Changes section appears at the end of this standard.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1

---------------------- Page: 1 ----------------------
C452 – 06
6. Materials mixer and shake the excess mortar from the paddle into the
bowl. Fill the mold in two layers, each layer being compacted
6.1 Use graded sand that conforms to Specification C778
with the tamper. Work the mortar into the corners, around the
Table 1 Standard Sand Requirements for making the test
gage studs, and along the surfaces of the mold with the tamper
mortar.
until a homogeneous specimen is obtained. After the top layer
6.2 For the gypsum addition to portland cement, use high
4
has been compacted, cut the mortar off flush with the
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.