Metallic materials - Tensile stress relaxation testing - Part 1: Procedure for testing machines

This European Standard specifies the test method for the determination of relaxation of stress of metallic test pieces subjected throughout the test to nominally constant strain and constant temperature conditions.

Metallische Werkstoffe - Relaxationsversuch unter Zugbeanspruchung - Teil 1: Prüfverfahren für die Anwendung in Prüfmaschinen

Matériaux métalliques - Essai de relaxation en traction - Partie 1: Mode opératoire pour machines d'essai

Le présent projet de Norme européenne spécifie la méthode d'essai pour la détermination de la relaxation de contrainte d'éprouvettes métalliques soumises tout au long de l'essai à une déformation nominalement constante et à des conditions de température constante.

Kovinski materiali - Preskušanje relaksacije pri natezni obremenitvi - 1. del: Postopek na preskuševalnih strojih

General Information

Status
Published
Publication Date
17-Jun-2003
Withdrawal Date
30-Dec-2003
Current Stage
9093 - Decision to confirm - Review Enquiry
Completion Date
06-Apr-2020

Buy Standard

Standard
EN 10319-1:2004
English language
18 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Kovinski materiali - Preskušanje relaksacije pri natezni obremenitvi - 1. del: Postopek na preskuševalnih strojihMetallische Werkstoffe - Relaxationsversuch unter Zugbeanspruchung - Teil 1: Prüfverfahren für die Anwendung in PrüfmaschinenMatériaux métalliques - Essai de relaxation en traction - Partie 1: Mode opératoire pour machines d'essaiMetallic materials - Tensile stress relaxation testing - Part 1: Procedure for testing machines77.040.10Mehansko preskušanje kovinMechanical testing of metalsICS:Ta slovenski standard je istoveten z:EN 10319-1:2003SIST EN 10319-1:2004en01-marec-2004SIST EN 10319-1:2004SLOVENSKI
STANDARD
EUROPEAN STANDARDNORME EUROPÉENNEEUROPÄISCHE NORMEN 10319-1June 2003ICS 77.040.10English versionMetallic materials - Tensile stress relaxation testing - Part 1:Procedure for testing machinesMatériaux métalliques - Essai de relaxation en traction -Partie 1: Mode opératoire pour machines d'essaiMetallische Werkstoffe - Relaxationsversuch unterZugbeanspruchung - Teil 1: Prüfverfahren für dieAnwendung in PrüfmaschinenThis European Standard was approved by CEN on 21 March 2003.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the Management Centre or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the Management Centre has the same status as the officialversions.CEN members are the national standards bodies of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece,Hungary, Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands, Norway, Portugal, Slovakia, Spain, Sweden, Switzerland and UnitedKingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMITÉ EUROPÉEN DE NORMALISATIONEUROPÄISCHES KOMITEE FÜR NORMUNGManagement Centre: rue de Stassart, 36
B-1050 Brussels© 2003 CENAll rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 10319-1:2003 ESIST EN 10319-1:2004

Information concerning different types of thermocouples.16Annex B (informative)
Information concerning methods of calibration of thermocouples.17Bibliography.18SIST EN 10319-1:2004

Le , in the reference length (Lr)SIST EN 10319-1:2004

Le , by the reference length (Lr)3.5.1total strain (t)strain applied to the test piece at any time, t, during the testNOTETotal strain is the sum of elastic and plastic strain, see Figure 1.3.5.2initial total strain (to)strain applied to the test piece at the commencement of the test3.6stressat any time during the test, force divided by the original cross-sectional area (So) of the test pieceDistinction is made between:3.6.1initial stress ()stress at the commencement of the test3.6.2residual stress (rt)value to which the stress in the test piece has relaxed, at any time, t, during the testSIST EN 10319-1:2004

1 MPa = 1 N/mm².SIST EN 10319-1:2004

reduced to a minimum.The force shall be applied to the test piece without shock.NOTEIt is recommended that the machine be isolated from external vibration and shock.The testing machine shall be verified and shall meet the requirements of at least class 1 in accordance with ENISO 7500-1:1999.The type of machine (e.g. servo-controlled electro-mechanic, servo-controlled hydraulic or sliding weight machine)shall be indicated in the test report.6.2 Extension measuring deviceThe extension shall be measured using an extensometer which meets the bias requirements of at least class 1 inaccordance with EN 10002-4:1994 and a resolution lower than or equal to one tenth of this bias value.The extensometer shall be calibrated at intervals not exceeding 3 years. If the predicted test time exceeds the dateof the expiry of the calibration certificate, the extensometer shall be calibrated prior to commencement of therelaxation test.The extensometer gauge length depends upon the performance characteristics of the extensometry used tomeasure the strain. A minimum gauge length of 100 mm is recommended. If insufficient material is available,shorter gauge lengths may be used provided that the extensometry used has a sufficient resolution. The use ofshorter gauge lengths shall be recorded in the test report. The extensometer should be able to measure theextension on two opposite sides of the test piece. Side contact extensometry is permitted; where used this shall bereported in the test report.NOTEWhen measured on the opposite sides, the average extension should be reported.6.3 Heating device6.3.1 Permissible temperature deviationsThe heating device shall heat the test piece to the specified temperature (T).The permitted deviations betw
...