Extended application of test results on durability of self-closing for doorsets and openable windows - Part 4: Durability of self-closing of fire resistance and/or smoke control hinged and pivoted metal framed glazed doorsets and openable windows

This document is applicable to single and double leaf, hinged and pivoted metal framed, glazed doorsets or openable windows as covered by EN 15269 5 or EN 15269 20.
This document prescribes the methodology for extending the application of test results obtained from durability of self-closing test(s) conducted in accordance with EN 1191.
Subject to the completion of the appropriate self-closing test(s), the extended application can cover all or some of the following non-exhaustive list:
-   doorsets and openable windows;
-   door or window leaves;
-   wall or ceiling fixed elements (frame or suspension system);
-   glazing and non-glazed panels in doorset and openable window, side, transom and/or overpanels;
-   items of building hardware;
-   decorative finishes;
-   intumescent, smoke, draught or acoustic seals;
-   alternative supporting construction(s).

Erweiterter Anwendungsbereich von Prüfergebnissen zur Dauerhaftigkeit der Selbstschließung für Türen und zu öffnende Fenster - Teil 4: Dauerhaftigkeit der Selbstschließung von verglasten Drehflügeltüren und zu öffnenden Fenstern mit Metall(rohr)rahmen mit Feuerwiderstands- und/oder Rauchdichtigkeitseigenschaften

Dieses Dokument ist anzuwenden für ein- und zweiflügelige verglaste Drehflügeltüren und zu öffnende Fenster mit Metallrahmen, wie sie in EN 15269 5 oder EN 15269 20 beschrieben werden.
Das vorliegende Dokument schreibt die Methodik für die Erweiterung der Anwendung der Prüfergebnisse vor, die aus Prüfungen der Dauerhaftigkeit der Selbstschließung erhalten wurden, die in Übereinstimmung mit EN 1191 durchgeführt wurden.
In Abhängigkeit des Abschlusses der entsprechenden Selbstschließungsprüfung(en) kann die erweiterte Anwendung alle oder einige Elemente der folgenden unvollständigen Liste abdecken:
- Türen und zu öffnende Fenster;
- Tür- oder Fensterflügel;
- an der Wand oder Decke befestigte Elemente (Rahmen- oder Suspensionssystem);
- Verglasung und nicht verglaste Paneele in Türen und zu öffnenden Fenstern, Seitenteile, Oberteile mit Kämpfer und/oder obere Türblenden;
- Baubeschlagelemente;
- Dekorative Oberflächenausführungen;
- dämmschichtbildende Dichtungen, sowie Dichtungen zur Behinderung von Rauchdurchtritt (Rauch-schutzdichtungen), Durchzug oder Schallübertragung (Schallschutzdichtungen);
- alternative Tragkonstruktion(en).

Application étendue des résultats d’essais de durabilité de la fermeture automatique des blocs-portes et fenêtres ouvrantes - Partie 4 : Durabilité de la fermeture automatique des blocs-portes vitrés battants et pivotants à ossature métallique et des fenêtres ouvrantes à ossature métallique résistants au feu et/ou étanches à la fumée

Le présent document s’applique aux blocs-portes vitrés battants et pivotants à ossature métallique et aux fenêtres ouvrantes à ossature métallique, à un ou deux vantaux, visés par l’EN 15269 5 ou l’EN 15269 20.
Ce document établit la méthodologie d’extension de l’application des résultats d’essai obtenus suite aux essais de durabilité de la fermeture automatique réalisés conformément à l’EN 1191.
Sous réserve de la réalisation de l’essai ou des essais appropriés de fermeture automatique, l’application étendue peut couvrir tout ou partie des éléments de la liste non exhaustive suivante :
-   blocs-portes et fenêtres ouvrantes ;
-   vantaux de bloc-porte ou de fenêtre ;
-   éléments fixes muraux ou de plafond (structure ou système de suspension) ;
-   vitrages et panneaux non vitrés d’un bloc-porte ou d’une fenêtre ouvrante, de panneaux latéraux et/ou d’impostes ;
-   tout élément de quincaillerie de bâtiment ;
-   finitions décoratives ;
-   joints intumescents, joints d’étanchéité aux fumées, joints d’étanchéité à l’air ou joints acoustiques ;
-   autre(s) support(s).

Razširjena uporaba rezultatov preskusov trajnosti samozapiranja za vrata in okna, ki se odpirajo - 4. del: Trajnost samozapiranja požarno odpornih in/ali dimotesnih zastekljenih vrat v kovinskih okvirjih z vrtljivim krilom in oken, ki se odpirajo

General Information

Status
Published
Publication Date
11-May-2021
Withdrawal Date
29-Nov-2021
Current Stage
6060 - Definitive text made available (DAV) - Publishing
Start Date
12-May-2021
Due Date
26-Aug-2021
Completion Date
12-May-2021
Standard
EN 17020-4:2021
English language
55 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-julij-2021
Razširjena uporaba rezultatov preskusov trajnosti samozapiranja za vrata in okna,
ki se odpirajo - 4. del: Trajnost samozapiranja požarno odpornih in/ali dimotesnih
zastekljenih vrat v kovinskih okvirjih z vrtljivim krilom in oken, ki se odpirajo
Extended application of test results on durability of self-closing for doorsets and
openable windows - Part 4: Durability of self-closing of fire resistance and/or smoke
control hinged and pivoted metal framed glazed doorsets and openable windows
Erweiterter Anwendungsbereich von Prüfergebnissen zur Dauerhaftigkeit der
Selbstschließung für Türen und zu öffnende Fenster - Teil 4: Dauerhaftigkeit der
Selbstschließung von verglasten Drehflügeltüren und zu öffnenden Fenstern mit Metall
(rohr)rahmen mit Feuerwiderstandseigenschaften
Application étendue des résultats d ’essais de durabilité de la fermeture automatique des
blocs-portes et fenêtres ouvrantes - Partie 4 : Durabilité de la fermeture automatique des
blocs-portes vitrés battants et pivotants à ossature métallique et des fenêtres ouvrantes
à ossature métallique résistants au feu et/ou étanches à la fumée
Ta slovenski standard je istoveten z: EN 17020-4:2021
ICS:
13.220.50 Požarna odpornost Fire-resistance of building
gradbenih materialov in materials and elements
elementov
91.060.50 Vrata in okna Doors and windows
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EN 17020-4
EUROPEAN STANDARD
NORME EUROPÉENNE
May 2021
EUROPÄISCHE NORM
ICS 13.220.50; 91.060.50
English Version
Extended application of test results on durability of self-
closing for doorsets and openable windows - Part 4:
Durability of self-closing of fire resistance and/or smoke
control hinged and pivoted metal framed glazed doorsets
and openable windows
Application étendue des résultats d'essais de durabilité Erweiterter Anwendungsbereich von Prüfergebnissen
de la fermeture automatique des blocs-portes et zur Dauerhaftigkeit der Selbstschließung für Türen
fenêtres ouvrantes - Partie 4 : Durabilité de la und zu öffnende Fenster - Teil 4: Dauerhaftigkeit der
fermeture automatique des blocs-portes vitrés battants Selbstschließung von verglasten Drehflügeltüren und
et pivotants à ossature métallique et des fenêtres zu öffnenden Fenstern mit Metall(rohr)rahmen mit
ouvrantes à ossature métallique résistants au feu et/ou Feuerwiderstandseigenschaften
étanches à la fumée
This European Standard was approved by CEN on 12 April 2021.

CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this
European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references
concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN
member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by
translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management
Centre has the same status as the official versions.

CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway,
Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and
United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION

EUROPÄISCHES KOMITEE FÜR NORMUNG

CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2021 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 17020-4:2021 E
worldwide for CEN national Members.

Contents Page
European foreword . 3
Introduction . 4
1 Scope . 5
2 Normative references . 5
3 Terms and definitions . 6
4 Determination of the field of extended application . 7
4.1 General . 7
4.2 Procedure for evaluation . 7
4.3 Procedure for maximum field of extended application . 7
4.4 Interpretation of test results . 8
5 Extended application report . 8
6 Classification report . 8
Annex A (normative) Construction parameter variations . 9
Annex B (normative) Construction parameter variation simulation by applying additional
weights . 54
Bibliography . 55

European foreword
This document (EN 17020-4:2021) has been prepared by Technical Committee CEN/TC 127 “Fire safety
in buildings”, the secretariat of which is held by BSI.
This European Standard shall be given the status of a national standard, either by publication of an
identical text or by endorsement, at the latest by November 2021, and conflicting national standards shall
be withdrawn at the latest by November 2021.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CEN shall not be held responsible for identifying any or all such patent rights.
This document has been prepared under a mandate given to CEN by the European Commission and the
European Free Trade Association.
According to the CEN-CENELEC Internal Regulations, the national standards organisations of the
following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia,
Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland,
Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Republic of North
Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United
Kingdom.
Introduction
The EN 15269 series of standards covering extended application of test results for fire resistance and/or
smoke control for door, shutter and openable window assemblies, including their items of building
hardware, does not include the durability of self-closing of the doorsets following an extended application
process. This document is one of the EN 17020 series of standards intended to be used for the purpose of
producing an extended application report based on the evaluation of one or more durability of self-
closing tests. These European Standards may also be used to identify the best selection of test specimens
required to cover a wide range of product variations.
1 Scope
This document is applicable to single and double leaf, hinged and pivoted metal framed, glazed doorsets
or openable windows as covered by EN 15269-5 or EN 15269-20.
This document prescribes the methodology for extending the application of test results obtained from
durability of self-closing test(s) conducted in accordance with EN 1191.
Subject to the completion of the appropriate self-closing test(s), the extended application can cover all or
some of the following non-exhaustive list:
— doorsets and openable windows;
— door or window leaves;
— wall or ceiling fixed elements (frame or suspension system);
— glazing and non-glazed panels in doorset and openable window, side, transom and/or overpanels;
— items of building hardware;
— decorative finishes;
— intumescent, smoke, draught or acoustic seals;
— alternative supporting construction(s).
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments) applies.
EN 1125, Building hardware - Panic exit devices operated by a horizontal bar, for use on escape routes -
Requirements and test methods
EN 1154, Building hardware - Controlled door closing devices - Requirements and test methods
EN 1158, Building hardware - Door coordinator devices - Requirements and test methods
EN 1191, Windows and doors - Resistance to repeated opening and closing - Test method
EN 1363-1, Fire resistance tests - Part 1: General requirements
EN 1634-1, Fire resistance and smoke control tests for door and shutter assemblies, openable windows and
elements of building hardware - Part 1: Fire resistance test for door and shutter assemblies and openable
windows
EN 1634-3, Fire resistance and smoke control tests for door and shutter assemblies, openable windows and
elements of building hardware - Part 3: Smoke control test for door and shutter assemblies
EN 16035, Hardware performance sheet (HPS) - Identification and summary of test evidence to facilitate
the inter-changeability of building hardware for application to fire resisting and/or smoke control doorsets
and/or openable windows
EN 1935, Building hardware - Single-axis hinges - Requirements and test methods
EN 12209, Building hardware - Mechanically operated locks and locking plates - Requirements and test
methods
EN 12519, Windows and pedestrian doors - Terminology
EN 13501-1, Fire classification of construction products and building elements - Part 1: Classification using
data from reaction to fire tests
EN 13501-2:2016, Fire classification of construction products and building elements - Part 2: Classification
using data from fire resistance tests, excluding ventilation services
EN 13637, Building hardware - Electrically controlled exit systems for use on escape routes - Requirements
and test methods
EN 14846, Building hardware - Locks and latches - Electromechanically operated locks and striking plates
- Requirements and test methods
EN 15269-1, Extended application of test results for fire resistance and/or smoke control for door, shutter
and openable window assemblies, including their elements of building hardware - Part 1: General
requirements
EN 15269-5:2014+A1:2016, Extended application of test results for fire resistance and/or smoke control
for door, shutter and openable window assemblies, including their elements of building hardware - Part 5:
Fire resistance of hinged and pivoted metal framed glazed doorsets and openable windows
EN 15269-20, Extended application of test results for fire resistance and/or smoke control for door, shutter
and openable window assemblies, including their elements of building hardware - Part 20: Smoke control
for doors, shutters, operable fabric curtains and openable windows
EN 15685 , Building hardware - Requirements and test methods - Multipoint locks, latches and locking
plates - Characteristics and test methods
EN 16034, Pedestrian doorsets, industrial, commercial, garage doors and openable windows - Product
standard, performance characteristics - Fire resisting and/or smoke control characteristics
EN 179, Building hardware - Emergency exit devices operated by a lever handle or push pad, for use on
escape routes - Requirements and test methods
EN ISO 13943, Fire safety - Vocabulary (ISO 13943)
3 Terms and definitions
For the purposes of this document, the terms and definitions given in EN 1191, EN 1363-1, EN ISO 13943,
EN 1634-1, EN 1634-3, EN 12519, EN 15269-1, EN 15269-5 and EN 15269-20, and the following apply.
ISO and IEC maintain terminological databases for use in standardization at the following addresses:
• ISO Online browsing platform: available at https://www.iso.org/obp
• IEC Electropedia: available at https://www.electropedia.org/

Under preparation. Stage at the time of publication: prEN 15685.
3.1
full scale test
test of a full size doorset/openable window in accordance with EN 1191
4 Determination of the field of extended application
4.1 General
4.1.1 Before there can be any consideration for extended application, the doorset/openable window
shall have been tested in accordance with EN 1191 to achieve a test result which could generate a
classification in accordance with EN 13501-2 or correspond to a use category according to EN 16034.
4.1.2 A review of the doorset/openable window construction parameters can indicate that one or more
characteristics can be improved by a particular parameter variation. All evaluations shall be made on the
basis of retaining the classifications obtainable from testing to EN 1191, including those with a lower
number of opening and closing cycles. However, this shall never lead to an increased classification for
any specific parameter beyond that achieved by testing, unless specifically identified in the relevant
Construction Parameter Variation tables.
4.1.3 If, when following the extended application procedure, any part of the classified product cannot
be covered by the extended application rules, that part shall be omitted from the subsequent extended
application report and classification report.
4.2 Procedure for evaluation
4.2.1 Identify the variations from the original test specimen(s) which are required to be covered by an
extended application report.
4.2.2 Locate the variations in the appropriate parameter variation by reference to columns (1) and (2)
of Annex A, Table A.1.
4.2.3 Establish from the contents of column (3) of Annex A, Table A.1 whether any extended application
is available without the need for further testing.
4.2.4 Where this is deemed to be possible, this can be recorded in the extended application report,
together with any appropriate restrictions and the stated rules from column (3) in Annex A, Table A.1.
4.2.5 Where the variations required can only be achieved from additional testing according to column
(4), the additional test can be made on a similar specimen type to the original test against which the
extended application is sought. Alternatively, column (4) in Annex A, Table A.1 identifies an option for
alternative testing and relevant test parameters.
4.3 Procedure for maximum field of extended application
4.3.1 It is possible to provide a limited field of extended application from the results of a single test.
However, where a manufacturer intends to produce a range of doorsets and openable windows
incorporating single leaf door assemblies and also double leaf door assemblies with or without glazing,
with alternative items of building hardware, etc., it is recommended that careful consideration is given to
the complete range of doorset designs and openable window designs and options in order to minimize
the testing required before testing commences.
4.3.2 Establish all the parameter variations which are required to be part of the product range.
4.3.3 Determine which are the most important specification requirements and incorporate as many as
possible into the specimen(s) for the first tests in the series.
4.3.4 Conduct the first durability test or a series of tests and then establish which of the original desired
parameter variations have not been covered by this test(s).
4.3.5 Identify these parameter variations in Annex A, Table A.1 and establish if any extended
application is possible without further testing.
4.3.6 Record this for the extended application report together with any restrictions and rules given in
column (3) in Annex A, Table A.1.
4.3.7 Evaluate which, if any, of the desired parameter variations have not been covered by the initial
field of extended application derived from 4.3.6 above.
4.3.8 Determine if the product range is to include only single leaf doorsets or if the range is also to
include double leaf configurations. Where only single leaf doorsets are to be part of the product range,
the outstanding construction parameter variations shall only be incorporated into specimens for the
single leaf doorsets. Where single leaf and double leaf doorsets are to be included in the product range,
the outstanding construction parameter variations for the extended application of single leaf doorsets
may be incorporated into either repeated single leaf doorset tests or, in the weakest option, as defined in
column (4) of the table in Annex A, Table A.1, double leaf doorset configurations.
4.3.9 Select the required outstanding parameter variations from column (1) and column (2) of Annex A,
Table A.1 and observe from column (4) in Annex A, Table A.1 which are the most appropriate weakest
specimen options for further testing.
4.3.10 If the complete selection of required parameter variations has not been covered by the tests
completed in accordance with 4.3.8 and 4.3.9 above, then an appropriate test or tests may be carried out
with the additional product variations incorporated.
4.4 Interpretation of test results
4.4.1 In order to maximize the extended field of application, it is important that the test reports shall
record details of any failures occurred throughout the test duration.
4.4.2 Where a series of tests have been conducted, the field of extended application shall be based on
the lowest performance achieved from the complete series of tests, unless premature failure has been
attributed to one or more specific construction parameter variations.
4.4.3 Where it has been possible to identify specific parameter failures, the extended application for all
other construction parameter variations can be based on the performance achieved after isolating the
premature failure(s).
5 Extended application report
Prepare an extended application report in accordance with the requirements of EN 15269-1, based on
the results of evaluations in accordance with the above.
6 Classification report
The classification report shall be determined from the results of the extended application report and shall
be presented in accordance with EN 13501-2:2016, Annex A.
Annex A
(normative)
Construction parameter variations
Table A.1 below is designed to be used by experts competent in the field of fire and smoke resistance and
durability of self-closing testing of hinged and pivoted metal framed glazed doorsets and openable
windows.
This table shall only be used to assess a field of extended application when at least one positive durability
of self-closing test according to EN 1191 has generated a classification according to EN 13501-2 and
EN 16034.
The first two columns identify possible variations to the construction details of the specimen tested. It is
presupposed that the variations do not restrain the door/window closing.
Column (3) leads to the judgement of the possibility of extending the field of application.
Where additional tests are deemed to be necessary, the type of specimen approved for incorporation of
the changed parameter is defined in column (4). Where it is possible to use information from tests
performed on one configuration for evidence on a different configuration, this allowance has been made
in order to reduce the overall number of tests required for extended application evaluation e.g. single
action doorsets to double action doorsets.
Where an additional test is required in column (4), the test is a full scale test, unless otherwise specified.
In order to maximize the possible field of application from a minimum number of tests, the parameter
changes have been spread over a series of test specimens. Where more than a single parameter variation
is required, the influence on other variations shall also be taken into account.
All the rules in Table A.1, with exception are applicable to doorsets and openable windows. However, in
the text only the word “doorset” is used. The word “doorset” can be replaced by “openable windows” in
every rule.
NOTE Column (1) contains titles that are identical to the ones of EN 15269-5:2014+A1:2016, Table A.1,
without reference to possible figures. For clarification the figures that are included in EN 15269-5:2014+A1:2016,
Annex A can be used.
Table A.1 — Construction parameter variations
Construction parameter Variation Possibility of extension Additional evidence required
(1) (2) (3) (4)
A Door leaf
For double leaf doorsets, both leaves shall be of the same basic construction.
A.1 General
Single leaf
Possible
A.1.1 Number of leaves from double –

leaf test
Double leaf
A.1.2 Number of leaves from single Not possible without additional test Additional test double leaf doorset
leaf test
Location
A.1.3 Intumescent seals between frame and
towards the Possible –
door leaf/leaves
frame rebate
Location away
A.1.4 Intumescent seals between frame and
from the Possible –
door leaf/leaves
frame rebate
A.1.5 Intumescent seals between meeting
Location Possible –
edges of the door leaves
A.1.6 Non-intumescent seals between frame
and door leaf/leaves
(draught/smoke/acoustic, etc.) – (Reaction
Location Possible –
to fire class A1 according to EN 13501-1)
e.g. ceramic products (fitted in leaf or
frame).
Construction parameter Variation Possibility of extension Additional evidence required
Possible providing the deformation of the seal will
A.1.7 Non-intumescent seals between
Additional test double for single and
not increase during movement of the door
meeting edges of the door leaves (draught
Location double leaf doorsets or single for single
leaf/leaves otherwise
smoke/acoustic, etc.) – (Reaction to fire
leaf doorsets
class A1 according to EN 13501-1)
not possible without an additional test
A.1.8 Non-intumescent seals between door
Possible providing the deformation of the seal will
leaves and/or frames Additional test double for single and
not increase during movement of the door
(draught/smoke/acoustic, etc.) – < Reaction Location double leaf doorsets or single for single
leaf/leaves otherwise
to fire class A1 according to EN 13501-1 leaf doorsets
not possible without an additional test
(fitted in leaf or frame)
A.1.9 Non-intumescent seals between door
leaves and/or frames Additional test double for single and
(draught/smoke/acoustic, etc.) – (Reaction Add Not possible without an additional test double leaf doorsets or single for single
to fire class A1 according to EN 13501-1), leaf doorsets
e.g. ceramic products (fitted in leaf or frame)
A.1.10 Non-intumescent seals between door
leaves and/or frames
(draught/smoke/acoustic, etc.) – (Reaction Remove Possible –
to fire class A1 according to EN 13501-1),
e.g. ceramic products (fitted in leaf or frame)
A.1.11 Non-intumescent seals between door
leaves and/or frames Additional test double for single and
(draught/smoke/acoustic, etc.) – < Reaction Add Not possible without an additional test double leaf doorsets or single for single
to fire class A1 according to EN 13501-1 leaf doorsets
(fitted in leaf or frame)
A.1.12 Non-intumescent seals between door
leaves and/or frames
(draught/smoke/acoustic, etc. – < Reaction Remove Possible –
to fire class A1 according to EN 13501-1
(fitted in leaf or frame)
Construction parameter Variation Possibility of extension Additional evidence required
Possible providing the requirements of Annex B are
Additional test single or double leaf
fulfilled
A.1.13 Ventilation grilles (louvres) in door
doorset
Add
leaf tested without ventilation grille otherwise

not possible without an additional test
A.1.14 Ventilation grilles (louvres) in door
Remove Possible –
leaf
A.1.15 Ventilation grilles (louvres) in the Location in
infill of the door leaf tested with ventilation vertical Possible –
grille direction
A.1.16 Ventilation grilles (louvres) in the Location in
infill of the door leaf tested with ventilation horizontal Possible –
grille direction
Location in
horizontal
A.1.17 Ventilation grilles (louvres) in door
and/or Possible –
leaf tested with ventilation grille
vertical
direction
A.1.18 Ventilation grilles (louvres) in door
leaf or in the infill of the door leaf tested Smaller size Possible –
with ventilation grille
Possible providing the requirements of Annex B are
A.1.19 Ventilation grilles (louvres) in door
fulfilled
Additional test single or double leaf
leaf or in the infill of the door leaf tested Larger size
otherwise doorset
with ventilation grille
not possible without an additional test
A.1.20 Rebate (door leaves to frames) Add Possible –
Add
A.1.21 Rebate (meeting edges) Possible –
(one rebate or
two rebates)
Construction parameter Variation Possibility of extension Additional evidence required
A.1.22 Rebate (door leaves to frames and
Remove Possible –
meeting edges)
Possible in line with the following relationship:
tested tested with tested with
without a a latch/lock a
latch/ but latch/lock
lock unlatched latched
extension to:
without a — Possible possible
lock/latch
Additional test double for single and
Change in
double leaf doorsets or single for single
A.1.23 Latched condition for single and extension to:
latching
leaf doorsets.
double leaf doorsets
with
condition
lock/latch
but Possible — possible
unlocked/
unlatched
(disengaged)
extension to:
with a Not Not

lock/latch, possible possible
latched
Remove from
door leaf
A.1.24 Latching/locking tested with Possible –
latching/
locking
Construction parameter Variation Possibility of extension Additional evidence required
A.2 Size variations
A.2.1 Size (area, width, height) Decrease Possible –
Possible by a maximum of 80 % providing the
Additional test double for single and
requirements of Annex B are fulfilled
A.2.2 Height Increase double leaf doorsets or single for single
otherwise
leaf doorsets
not possible without an additional test
Possible by a maximum of 25 % providing that the Additional test double for single and
A.2.3 Width Increase requirements of Annex B are fulfilled otherwise not double leaf doorsets or single for single
possible without an additional test leaf doorsets
Possible in line with A.2.2 and A.2.3, which can be
Additional test double for single and
combined
A.2.4 Area Increase double leaf doorsets or single for single
otherwise
leaf doorsets
not possible without an additional test
A.3 Materials and constructions
Possible providing the requirements of Annex B are
A.3.1 Density of infill of profile or core- Additional test double for single and
fulfilled
material in the panel (organic or Reaction to Increase double leaf doorsets or single for single
otherwise
fire class A1 according to EN 13501-1) leaf doorsets
not possible without an additional test
A.3.2 Density of infill of profile of core
material (organic or Reaction to fire class A1 Decrease Possible –
according to EN 13501-1)
Construction parameter Variation Possibility of extension Additional evidence required
Change of
supplier/
manufacturer
A.3.3 Type of infill of profile of core material
of identical
(single thickness or in combination of Possible –
material with
different layers)
identical
composition
and properties
Possible providing the requirements of Annex B are
Additional test double for single and
fulfilled
A.3.4 Type of core material (single thickness Alternative
double leaf doorsets or single for single
or in combination of different layers) composition otherwise
leaf doorsets
not possible without an additional test
A.3.5 Amount of adhesive/m – organic
based ( to EN 13501-1)
Possible by a maximum of 50 %
A.3.6 Amount of adhesive/m — organic
Additional test single or double leaf
based ( doorset
to EN 13501-1)
not possible without an additional test
A.3.7 Amount of adhesive/m — inorganic
based (Reaction to fire class A1 according to Increase Possible –
EN 13501-1)
2 Possible by a maximum of 50 %
A.3.8 Amount of adhesive/m — inorganic
Additional test single or double leaf
based (Reaction to fire class A1 according to Decrease otherwise
doorset
EN 13501-1)
not possible without an additional test
Change of
manufacturer
A.3.9 Type of adhesive Possible –
for identical
composition
Construction parameter Variation Possibility of extension Additional evidence required
Alternative
A.3.10 Type of adhesive Possible –
composition
A.3.11 Additional overlapping edge at the
Add Possible –
bottom of the door leaf
A.3.12 Overlapping edge at the bottom of the
Remove Possible –
door leaf
A.3.14 Dimension of intumescent seals
Increase Possible –
(fitted in leaf or frame)
A.3.15 Dimension of intumescent seals
Decrease Possible –
(fitted in leaf or frame)
Change of
A.3.16 Type of intumescent seals (fitted in
supplier/ Possible –
leaf or frame)
manufacturer
A.3.17 Type of intumescent seals (fitted in Alternative
Possible -
leaf or frame) material
Possible by a maximum of 15 % in any cross-
A.3.18 Dimension of draught/smoke seals
sectional dimension and by a maximum of 10 %
Additional test double for single and
(Reaction to fire class A1 according to
mass
Increase double leaf doorsets or single for single
EN 13501-1); e.g. ceramic products (fitted in
otherwise leaf doorsets doorset
leaf or frame)
not possible without an additional test
A.3.19 Dimension of draught/smoke seals
(Reaction to fire class A1 according to
Decrease Possible –
EN 13501-1); e.g. ceramic products (fitted in
leaf or frame)
Construction parameter Variation Possibility of extension Additional evidence required
Possible by a maximum of 15 % in any cross-
sectional dimension and by a maximum of 10 %
A.3.20 Dimension of draught/smoke seals Additional test double for single and
mass
( EN 13501-1) (fitted in leaf or frame) otherwise leaf doorsets
not possible without an additional test
A.3.21 Dimension of draught/smoke seals
( EN 13501-1) (fitted in leaf or frame)
Change of
A.3.22 Type of draught/smoke seals (fitted
supplier/ Possible –
in leaf or frame)
manufacturer
Alternative
material
(changing to
Additional test double for single and
A.3.23 Type of draught/smoke seals (fitted higher Possible by a maximum of ±15 % in density
double leaf doorsets or single for single
in leaf or frame) reaction to fire otherwise not possible without an additional test
leaf doorsets
class
according to
EN 13501-1)
Alternative
material
(changing to
Additional test double for single and
A.3.24 Type of draught/smoke seals (fitted an equal or a Possible by a maximum of ±15 % in density
double leaf doorsets or single for single
in leaf or frame) lower reaction otherwise not possible without an additional test
leaf doorsets
to fire class
according to
EN 13501-1)
Construction parameter Variation Possibility of extension Additional evidence required
A.4 Decorative and/or protective finishes
A.4.1 Paints without contribution to fire
Addition Possible –
resistance (on leaf or frame)
A.4.2 Paints without contribution to fire
Interchange Possible –
resistance (on leaf or frame)
A.4.3 Thickness of paints with positive
contribution to fire resistance (on leaf or Increase Possible –
frame)
A.4.4 Thickness of paints with positive
contribution to fire resistance (on leaf or Decrease Possible –
frame)
A.4.5 Type of paints with positive Change of
contribution to fire resistance (on leaf or supplier/ Possible –
frame) manufacturer
A.4.6 Type of paints with positive
Alternative
contribution to fire resistance (on leaf or Possible –
material
frame)
Possible in line with direct application according to
Additional test double for single and
EN 1634-1
A.4.7 Decorative laminates and timber
Add double leaf doorsets or single for single
veneers on the face (on leaf or frame) otherwise
leaf doorsets
not possible without additional test
A.4.8 Decorative laminates and timber
Remove Possible –
veneers on the face (on leaf or frame)
Possible providing primary gaps remain within the
tolerances given in EN 1634-1
A.4.9 Decorative laminates and timber Additional test single or double leaf
Add
veneers on the edges (on leaf or frame) otherwise doorset
not possible without additional test
Construction parameter Variation Possibility of extension Additional evidence required
Possible providing primary gaps remain within the
tolerances given in EN 1634-1
A.4.10 Decorative laminates and timber
Add Additional test double leaf doorset
veneers on meeting edges otherwise
not possible without additional test
A.4.11 Decorative laminates and timber
Remove Possible –
veneers on the edges (on leaf or frame)
Change
A.4.12 Types and thickness of decorative material
laminates and timber veneers on the face content, Possible –
(on leaf or frame) increase,
decrease
Change of material possible
Change
Decrease possible
A.4.13 Types and thickness of decorative material
increase possible providing primary gaps remain Additional test single or double leaf
laminates and timber veneers on the edges content,
within the tolerances given in EN 1634-1 doorset
(leaf to frame) increase,
otherwise
decrease
not possible without additional test
Change of material possible
Change
Decrease possible
A.4.14 Types and thickness of decorative material
increase possible providing primary gaps remain
laminates and timber veneers on the content, Additional test double leaf doorset
within the tolerances given in EN 1634-1
meeting edges increase,
otherwise
decrease
not possible without additional test
A.4.15 Types of decorative laminates and
Colour,
timber veneers on the face/edges (on leaf or Possible –
pattern
frame)
Construction parameter Variation Possibility of extension Additional evidence required
Possible providing the requirements of Annex B are
fulfilled
A.4.16 Protective elements – face fixed (kick Additional test single or double leaf
Add
plates/push plates/armour plates) otherwise doorset
not possible without an additional test
A.4.17 Protective elements – face fixed (kick
Remove Possible –
plates/push plates/armour plates)
Selection
A.4.18 Attachment technique for elements
(adhesive/ Possible –
added to doors
rivet/screw)
Possible providing the requirements of Annex B are
fulfilled
Additional test single or double leaf
A.4.19 Mouldings/profiles Add
otherwise doorset
not possible without an additional test
A.4.20 Mouldings/profiles Remove Possible –
A.5 Profiles in door leaf
Possible providing the requirements of Annex B are
fulfilled
A.5.1 Cross-section of profile of the door leaf Additional test single or double leaf
Increase depth
(including transoms and mullions) otherwise doorset
not possible without an additional test
A.5.2 No rule to remain consistent in
- - -
structure with EN 15269-5
A.5.3 Cross-section of profile of the door leaf Decrease Additional test single or double leaf
Not possible without an additional test
(including transoms and mullions) depth doorset
Construction parameter Variation Possibility of extension Additional evidence required
Change of
supplier/
manufacturer
A.5.3.a Type of infill material of material Possible –
with identical
composition
and properties
Possible providing the requirements of Annex B are
fulfilled
Alternative Additional test single or double leaf
A.5.3.b Type of infill material
material otherwise doorset
not possible without an additional test
Possible providing the requirements of Annex B are
fulfilled
Additional test single or double leaf
A.5.3.c Thickness of infill material Increase
otherwise doorset
not possible without an additional test
A.5.3.d Thickness of infill material Decrease Possible –
A.5.4 Cross-section of profile of the door leaf
Increase width Possible –
(including transoms and mullions)
A.5.5 No rule to remain consistent in
- - -
structure with EN 15269-5
A.5.6 Cross-section of profile of the door leaf Decrease Additional test single or double leaf
Not possible without an additional test
(including transoms and mullions) width doorset
A.5.7 Thickness of the metal wall of the
Increase Possible –
profile (including transoms and mullions)
A.5.8 Thickness of the metal wall of the Additional test single or double leaf
Decrease Not possible without an additional test
profile (including transoms and mullions) doorset
A.5.9 Horizontal rails Add Possible –
Construction parameter Variation Possibility of extension Additional evidence required
A.5.10 Horizontal rails Remove Possible –
A.5.11a Vertical stiles Add Possible –
A.5.11b Vertical stile Remove Possible –
Moving
A.5.12 Position of horizontal rail Possible –
upwards
Moving
A.5.13 Position of horizontal rail Possible –
downwards
Moving away
A.5.14 Position of vertical stile from the Possible –
hinges
Moving to the
A.5.15 Position of vertical stile Possible –
hinge side
Changing the angle of rails in any direction is
possible if tested as in EN 15269-5:2014+A1:2016,
Changing the Additional test single or double leaf
Figure A.28
A.5.16 Horizontal rails
angle doorset
otherwise
not possible without an additional test
Changing the angle of rails in any direction is
possible if tested as in EN 15269-5:2014+A1:2016,
Changing the Additional test single or double leaf
Figure A.28
A.5.17 Vertical stiles
angle doorset
otherwise
not possible without an additional test
Bended, Additional test can be single or double
A.5.18 Other changes of rails and stiles Not possible without additional test
shaped, etc. leaf doorset
Other than Additional test can be single or double
A.5.19 Shapes of door leaf Not possible without additional test
rectangular leaf doorset
Construction parameter Variation Possibility of extension Additional evidence required
Mild to
A.5.20 Type of steel Possible -
stainless steel
Stainless to
A.5.21 Type of steel Possible -
mild steel
B Door Frame
B.1 General
For intumescent/draught/smoke seals refer to section A.1
B.1.1 Threshold/sill/frame member at
Add Possible –
bottom of door frame
B.1.2 Threshold/sill/frame member at
Remove Possible –
bottom of door frame
B.1.3 Height of hatch door frame above floor Variation Possible –
B.1.4 Height of doorset above floor Variation Possible –
B.2 Materials and constructions rules related to open profiles in perimeter frame
Possible providing the cross-section detail at the
overlap/rebate position (shown in bold in
EN 15269-5:2014+A1:2016, Figure A.32) is
retained and/or possible to increase the
Additional test double for single and
overlap/rebate detail in line with the increase of
B.2.1 Overall dimensions and shape Increase double leaf doorsets or single for single
the depth of the cross-section of the profile
leaf doorsets
of the door leaf
otherwise
not possible without an additional test
Construction parameter Variation Possibility of extension Additional evidence required
Possible providing the cross-section detail at the
overlap/rebate position (shown in bold in
EN 15269-5:2014+A1:2016, Figure A.32) is
retained and/or possible to decrease the
Additional test double for single and
overlap/rebate detail in line with the decrease of
B.2.2 Overall dimensions and shape Decrease double leaf doorsets or single for single
the depth of the cross-section of the profile of the
leaf doorsets
door leaf
otherwise
not possible without an additional test
Possible if carried out according to
Open profile Additional test double for single and
EN 15269-5:2014+A1:2016, Figure A.34
B 2.2.a Cross-section dimensions and shape to closed double leaf doorsets or single for single
otherwise
profile leaf doorsets
not possible without an additional test
Change of
supplier/
manufacturer
B.2.3 Type of infill material of material Possible –
with identical
composition
and properties
Possible providing tested without any infill
Additional test double for single and
material
Alternative
B.2.4 Type of infill material double leaf doorsets or single for single
material otherwise
leaf doorsets
not possible without an additional test
B.2.5 Thickness of metal Increase Possible –
Additional test double for single and
B.2.6 Thickness of metal Decrease Not possible without an additional test double leaf doorsets or single for single
leaf doorsets
Construction parameter Variation Possibility of extension Additional evidence required
Change of
basic material
Additional t
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.

Loading comments...