EN 16265:2026
(Main)Pyrotechnic articles - Other pyrotechnic articles - Ignition devices
- Abstract
This document defines the terms and specifies the requirements, means of categorization, test methods, minimum labelling requirements and instructions for use of the article, for ignition devices (except ignition devices for pyrotechnic articles for vehicles) of the following generic types:
- igniters;
- components for pyrotechnic trains;
- pyrotechnic cords and fuses;
- delay fuses;
- fuzes.
NOTE Safety fuses are subject to Directive 2014/28/EU [9] and therefore not considered in this document.
- Status
- Published
- Publication Date
- 27-Oct-2026
- Technical Committee
- CEN/TC 212 - Fireworks
- Drafting Committee
- CEN/TC 212/WG 5 - Other pyrotechnic articles, category P1 and P2
- Current Stage
- 6060 - Definitive text made available (DAV) - Publishing
- Start Date
- 28-Oct-2026
- Due Date
- 13-Aug-2026
- Completion Date
- 28-Oct-2026
EN 16265:2026 is a CEN European Standard for ignition devices used in pyrotechnic articles, except ignition devices for pyrotechnic articles for vehicles. It specifies the terms, categorization, requirements, test methods, minimum labelling and instructions for use for igniters, components for pyrotechnic trains, pyrotechnic cords and fuses, delay fuses and fuzes. In practice, it is the document a manufacturer, test laboratory, quality manager or buyer uses to check whether an ignition device is designed, tested and marked in the way this family of products requires.
What does EN 16265:2026 specify?
EN 16265:2026 covers the safety and performance framework for ignition devices in the listed generic types, and it also sets the rules for how they are categorized and identified. It excludes ignition devices for pyrotechnic articles for vehicles, safety fuses subject to Directive 2014/28/EU, and articles containing certain listed substances such as arsenic compounds, mercury compounds and white phosphorus.
The document is organized into seven main clauses and several annexes. Clause 4 groups the products into generic types, subtypes and P1/P2 conditions. Clauses 5 and 6 set the requirements and the test methods, and Clause 7 covers labelling and instructions for use.
| Annex | What it covers |
|---|---|
| Annex A | Bruceton method for determining the 50 % stimulus level |
| Annex B | Dichotomic (Langlie) method as an alternative sequential method |
| Annex C | Mechanical conditioning with a shock apparatus |
| Annex D | Mechanical impact test (drop test) |
| Annex E | Grinding steel specification for the wire abrasion test |
| Annex F | Accelerated ageing to support the “use by” date |
| Annex G | Apparatus for testing sensitiveness of pyrotechnic composition to electrostatic discharge |
| Annex ZA | Relationship to Directive 2013/29/EU |
What are the key requirements of EN 16265:2026?
EN 16265:2026 ties product acceptance to design control, functional testing, safety features, and clear product information. The most important point for users is that the device is not judged only by appearance - it must also function as specified after the relevant conditioning and abuse tests.
Product category and design control
Clause 4 sets out generic types, subtypes and conditions for deciding whether an article is P1 or P2. That classification matters because it drives how the article is tested, labelled and handled.
Clause 5.1 requires verification of construction and design, including checks for incompatible substances and for the use of detonative explosives where relevant. For a manufacturer, this means the technical file and actual construction must match before testing and release.
Functioning and safety performance
Clause 5.3 requires verification of the specified functioning characteristics for the different product families. The document links those checks to the test methods in Clause 6, so the declared ignition, transmission, burning or delay performance must be demonstrated, not just stated.
Clause 5.4 requires thermal stability. After thermal conditioning, the article must not ignite or degrade in the test, and it must still function properly at the intended temperature limits. For electric igniters, the insulation of the leading wires must remain intact.
Clause 5.5 requires safety features such as protective packing or covers, safe/arm components where appropriate, electromagnetic field protection for electric igniters, and protection against electrostatic discharge (ESD). This matters in production, transport and handling because the article has to remain safe before it is intentionally initiated.
Handling, moisture and mechanical resistance
Clause 5.6 addresses normal, foreseeable handling and transportation. Ignition devices tested in their primary pack, if any, and with safety features fitted must not ignite during mechanical conditioning, and they must still function afterwards. For P2 articles, loose pyrotechnic composition outside the article is limited, and certain articles also undergo a drop test.
Clause 5.7 adds moisture resistance where the article is intended for humid, wet or underwater use. In practical terms, the device must still function after the relevant moisture conditioning or immersion test.
Clause 5.8 covers mechanical damage resistance for specific parts such as leading wires, leading optical fibre, crush resistance, and pyrotechnic cords and fuses. This is important for cable routing, packaging design and field handling.
Ignition levels, electrical safety and batch control
Clause 5.9 requires all-fire and no-fire levels for igniters to be determined by the Bruceton method or the Dichotomic (Langlie) method in Annexes A and B. The test uses at least 25 igniters and a 95 % confidence level, so the declared firing window has to be statistically supported.
Clause 5.10 requires series-firing verification for electric igniters intended to be used in series, with no misfire in the test. Clause 5.11 checks electrical resistance and insulation resistance, and Clause 5.12 checks ESD resistance. For electric igniters, the measured electrical behaviour has to stay within the declared range and the device must not function when exposed to the ESD test.
Clause 5.13 covers the “use by” date. If a use-by date is claimed, the article has to keep the specified performance until that date, and longer storage claims can be supported by accelerated ageing in Annex F.
Clauses 5.14 and 5.15 set type-test and batch-test rules, including sampling plans, small-batch sample sizes, nonconformity classes, and acceptance or rejection of a batch. This is the part buyers and quality teams usually use to decide whether a lot can be released.
What terms does EN 16265:2026 define?
- Generic type - a set of articles with common, very general design features and/or common characteristic effects.
- Subtype - a set of articles within a generic type that share specific design features.
- Individual item - a single article whose features and characteristics are fully fixed.
- Acceptance quality limit (AQL) - the worst tolerable process average when lots are inspected by sampling.
- All-fire level - the lowest stimulus level that ensures an igniter fires within a given time frame.
- No-fire level - the highest stimulus level that can be applied without causing the igniter to function within a given time frame.
- Net explosive content (NEC) - the total mass of explosive substance in a pyrotechnic article.
- Misfire - incomplete functioning or no functioning after the initiation stimulus has been applied.
Who uses EN 16265:2026?
EN 16265:2026 is used by manufacturers and importers of ignition devices, especially makers of igniters, pyrotechnic cords and fuses, delay fuses, fuzes and components for pyrotechnic trains. It is also used by test laboratories that perform type tests, batch tests, thermal conditioning, mechanical conditioning, electrical checks and ESD testing.
Quality managers use it to define acceptance criteria, sampling plans, labelling checks and release rules. Buyers and conformity assessors use it to compare products and verify that the declared performance, category and instructions for use match the standard’s requirements.
What changed in EN 16265:2026 from the previous edition?
EN 16265:2026 supersedes EN 16265:2015. The foreword lists these main changes: references to Directive 2007/23/EC were removed; definitions were revised, including the improvement of “explosive substance” and the addition of “output effect” and “secondary explosive”; three subtypes were added, including reactive tape, ignition rod and ignition stick; hand-held igniters and pyrotechnic trains were added and developed in the categorization and requirements clauses; the treatment of “use by” date was added and revised; batch-test nonconformity handling was updated; the number of items used in the detonative/non-detonative test was changed; the ESD generator adjustment text was removed and a new Annex G was added; and the slow release test was deleted.
Which standards are used with EN 16265:2026?
- EN ISO 13385-1:2019 - gives the metrological characteristics of callipers used for dimensional measurements.
- EN 61672-1:2013 - provides the specification for sound level meters used in the test methods.
- FprEN 13763-1:2025 - supplies the reference detonators used in the water-tank method for determining detonative or non-detonative characteristics.
- EN 10088-2:2024 - specifies the stainless steel used for the grinding steel in the wire abrasion test.
- ISO 2859-1:1999, as impacted by ISO 2859-1:1999/A1:2011 - provides the acceptance-sampling framework used for batch inspection.
- EN ISO 868, ISO 845 and EN ISO 2439 - are used in Annex C for the shock apparatus materials and hardness/density checks.
- ISO 565:1990 - is used in Annex G for sieve preparation of the test sample.
What does the EN 16265:2026 document contain?
EN 16265:2026 contains a structured set of apparatus descriptions, procedures and evaluation rules for the main performance and safety tests on ignition devices. Clause 6 covers measurements such as initiation time, closed vessel behaviour, flame or reacting flow, fire transmission, burning rate, thermal conditioning, mechanical conditioning, abrasion, traction, crush, series firing, electrical resistance, insulation resistance, ESD, water immersion, detonative/non-detonative character, visual examination and pyrotechnic composition sensitivity.
The annexes add the more detailed technical parts that a lab would need to run the tests. Annexes A and B give the statistical methods and calculation approaches for all-fire/no-fire levels, Annexes C, D and G show test apparatus, Annex E specifies the abrasive steel, and Annex F gives the accelerated-ageing basis for “use by” claims.
Clause 7 then turns the technical results into product information. It requires labelling for name and type, CE marking, category and registration number, age limits, NEC, manufacturer or importer details, ignition input and very small items, plus instructions for use that explain firing inputs, hazards, safety features, electrical or optical characteristics, serial use limits, storage, transport, disposal and end-of-life handling.
Relations
- Effective Date
- 22-Mar-2023
- Effective Date
- 11-Nov-2026
- Effective Date
- 11-Nov-2026
- Effective Date
- 11-Nov-2026
- Effective Date
- 11-Nov-2026
- Effective Date
- 11-Nov-2026
- Effective Date
- 11-Nov-2026
- Effective Date
- 11-Nov-2026
- Effective Date
- 11-Nov-2026
Get Certified
Connect with accredited certification bodies for this standard

ECOCERT
Organic and sustainability certification.

Eurofins Food Testing Global
Global leader in food, environment, and pharmaceutical product testing.

Intertek Bangladesh
Intertek certification and testing services in Bangladesh.
Sponsored listings
Frequently Asked Questions
EN 16265:2026 is a standard published by the European Committee for Standardization (CEN). Its full title is "Pyrotechnic articles - Other pyrotechnic articles - Ignition devices". This standard covers: This document defines the terms and specifies the requirements, means of categorization, test methods, minimum labelling requirements and instructions for use of the article, for ignition devices (except ignition devices for pyrotechnic articles for vehicles) of the following generic types: - igniters; - components for pyrotechnic trains; - pyrotechnic cords and fuses; - delay fuses; - fuzes. NOTE Safety fuses are subject to Directive 2014/28/EU [9] and therefore not considered in this document.
This document defines the terms and specifies the requirements, means of categorization, test methods, minimum labelling requirements and instructions for use of the article, for ignition devices (except ignition devices for pyrotechnic articles for vehicles) of the following generic types: - igniters; - components for pyrotechnic trains; - pyrotechnic cords and fuses; - delay fuses; - fuzes. NOTE Safety fuses are subject to Directive 2014/28/EU [9] and therefore not considered in this document.
EN 16265:2026 is classified under the following ICS (International Classification for Standards) categories: 71.100.30 - Explosives. Pyrotechnics and fireworks. The ICS classification helps identify the subject area and facilitates finding related standards.
EN 16265:2026 has the following relationships with other standards: It is inter standard links to EN 16265:2015, EN 61672-1:2013, EN 13631-4:2025, EN 13631-3:2025, EN 13763-1:2025, ISO 2859-1:2026, ISO 565:1990, EN 10088-2:2024, EN ISO 13385-1:2019. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
EN 16265:2026 is associated with the following European legislation: EU Directives/Regulations: 2013/29/EU; Standardization Mandates: M/583. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
EN 16265:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI STANDARD
01-januar-2027
Pirotehnični izdelki - Drugi pirotehnični izdelki - Vžigalne naprave
Pyrotechnic articles - Other pyrotechnic articles - Ignition devices
Pyrotechnische Gegenstände - Sonstige pyrotechnische Gegenstände - Anzündmittel
Articles pyrotechniques - Autres articles pyrotechniques - Dispositifs d'allumage
Ta slovenski standard je istoveten z: EN 16265:2026
ICS:
71.100.30 Eksplozivi. Pirotehnika in Explosives. Pyrotechnics and
ognjemeti fireworks
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EN 16265
EUROPEAN STANDARD
NORME EUROPÉENNE
October 2026
EUROPÄISCHE NORM
ICS 71.100.30 Supersedes EN 16265:2015
English Version
Pyrotechnic articles - Other pyrotechnic articles - Ignition
devices
Articles pyrotechniques - Autres articles Pyrotechnische Gegenstände - Sonstige pyrotechnische
pyrotechniques - Dispositifs d'allumage Gegenstände - Anzündmittel
This European Standard was approved by CEN on 28 September 2026.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this
European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references
concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN
member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by
translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management
Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway,
Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Türkiye and
United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2026 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 16265:2026 E
worldwide for CEN national Members.
Contents Page
European foreword . 6
1 Scope . 8
2 Normative references . 8
3 Terms and definitions . 9
3.1 General terms . 9
3.2 Technical terms . 9
4 Categories and types of ignition devices . 15
4.1 Generic types . 15
4.2 Subtypes . 15
4.3 Conditions determining whether an article is P1 or P2 . 17
4.3.1 Igniters . 17
4.3.2 Components for pyrotechnic trains . 17
4.3.3 Pyrotechnic cords and fuses . 17
4.3.4 Delay fuses . 18
4.3.5 Fuzes . 18
4.3.6 Hand-held igniter . 18
4.3.7 Pyrotechnic trains . 19
5 Requirements . 19
5.1 Verification of construction and design. 19
5.1.1 General. 19
5.1.2 Incompatible and forbidden substances . 19
5.1.3 Igniters . 20
5.1.4 Delay fuses . 20
5.1.5 Fuzes and components for pyrotechnic trains . 20
5.1.6 Pyrotechnic trains . 20
5.1.7 Detonative explosives . 20
5.2 Verification of labelling and instructions for use . 21
5.3 Verification of specified functioning characteristics . 21
5.3.1 General. 21
5.3.2 Igniters . 21
5.3.3 Components of pyrotechnic trains . 21
5.3.4 Delay fuses, pyrotechnic cords and fuses . 22
5.3.5 Fuzes . 22
5.3.6 Pyrotechnic trains . 22
5.4 Thermal stability . 23
5.5 Safety features. 23
5.6 Sensitivity to normal, foreseeable handling and transportation . 23
5.7 Resistance to moisture. 24
5.8 Resistance to mechanical damage . 24
5.8.1 Leading wires of electric igniters and electrically triggered fuzes . 24
5.8.2 Leading optical fibre of optical igniters and optically triggered fuzes . 24
5.8.3 Crush test . 25
5.8.4 Pyrotechnic cords and fuses . 25
5.9 All-fire / no-fire levels of igniters . 25
5.10 Series firings of electric igniters . 26
5.11 Electrical characteristics . 26
5.12 Electrostatic discharge . 26
5.13 “Use by” date . 26
5.14 Type tests . 27
5.14.1 General . 27
5.14.2 Number of items to be tested . 27
5.14.3 Test report . 28
5.15 Batch tests . 29
5.15.1 General . 29
5.15.2 Sampling plans. 29
5.15.3 Sample size for small batches (destructive tests) . 30
5.15.4 Nonconformities . 30
5.15.5 Labelling and instructions for use . 32
5.15.6 Test report . 32
5.15.7 Acceptance or rejection of a batch . 32
6 Test methods . 33
6.1 General . 33
6.2 Apparatus . 33
6.2.1 Calliper . 33
6.2.2 Ruler . 33
6.2.3 Balance . 33
6.2.4 Climatic chamber . 33
6.2.5 Sound level meter . 33
6.2.6 Electric firing sources . 33
6.2.7 Time-measuring equipment . 34
6.2.8 Optical sensors . 34
6.2.9 Pressure sensors . 34
6.2.10 Video camera . 34
6.2.11 Stills photographic camera . 34
6.2.12 Microphone . 34
6.2.13 Shock apparatus . 34
6.2.14 Drop-test apparatus. 34
6.2.15 Ohmmeters . 34
6.2.16 Magnifying equipment . 34
6.2.17 Transparent type size sheet . 35
6.3 Procedures . 35
6.3.1 Construction . 35
6.3.2 Verification of design . 35
6.3.3 Verification of labelling and instructions for use . 35
6.3.4 Initiation (or reaction) time . 36
6.3.5 Closed vessel test . 37
6.3.6 Aspect of flame or flow of reacting species . 39
6.3.7 Fire transmission . 41
6.3.8 Linear burning rate, delay time or functioning time . 42
6.3.9 Thermal conditioning . 45
6.3.10 Mechanical conditioning . 46
6.3.11 Mechanical impact (drop test) . 46
6.3.12 Resistance of leading wires to abrasion . 47
6.3.13 Resistance of leading wires or fibres to traction . 51
6.3.14 Crush test . 53
6.3.15 Resistance of cords and fuses to tension . 55
6.3.16 Series firing of electric igniters . 56
6.3.17 Electrical resistance of electric igniters . 57
6.3.18 Insulation resistance of electric igniters . 57
6.3.19 Electrostatic discharge. 59
6.3.20 Water immersion test . 60
6.3.21 Determination of the detonative / non-detonative characteristics . 61
6.3.22 Visual examination . 65
6.3.23 Sensitiveness of pyrotechnic composition . 65
7 Minimum labelling requirements and instructions for use . 69
7.1 General. 69
7.2 Labelling requirements . 69
7.2.1 Name and type . 69
7.2.2 CE marking and identification number . 69
7.2.3 Category and registration number . 69
7.2.4 Age limit and specialist knowledge labelling . 70
7.2.5 Net explosive content . 70
7.2.6 “Use by” date . 70
7.2.7 Printing . 70
7.2.8 Marking of very small items . 70
7.2.9 Ignition input . 70
7.3 Instructions for use . 70
Annex A (normative) Bruceton method. 72
A.1 General. 72
A.2 Procedure . 72
A.3 Calculation of results . 72
A.4 Values at 95 % confidence level . 73
A.5 Example . 74
A.6 Curves of G and H functions . 77
A.7 Table of Student-t distribution . 77
Annex B (normative) Dichotomic (or Langlie) method . 79
B.1 General. 79
B.2 Procedure . 79
B.3 Calculation of results . 80
B.4 Values at 95 % confidence level . 83
B.5 Example . 84
Annex C (informative) Mechanical conditioning (shock apparatus) . 87
Annex D (informative) Mechanical impact test (drop test) . 90
Annex E (normative) Specification of grinding steel for wire abrasion test . 91
E.1 Type . 91
E.2 Material . 91
E.3 Dimensions. 91
E.4 Availability of abrasive strips (informative) . 93
Annex F (informative) Determination of the duration of accelerated ageing test to
demonstrate the correct functioning at the “use by” date . 94
Annex G (normative) Apparatus for the testing of sensitiveness of the pyrotechnic
composition to electrostatic discharge . 98
G.1 Electrostatic energy supply. 98
G.2 Test cell assembly . 99
G.3 Preparation of the test sample . 99
G.4 Conditioning of the test sample and test conditions . 99
G.5 Evaluation of spark gap energy . 100
G.6 Reporting of results . 100
G.7 Test report . 100
Annex ZA (informative) Relationship between this European Standard and the essential
safety requirements of Directive 2013/29/EU aimed to be covered . 102
Bibliography . 104
European foreword
This document (EN 16265:2026) has been prepared by Technical Committee CEN/TC 212 “Pyrotechnic
articles”, the secretariat of which is held by NEN.
This European Standard shall be given the status of a national standard, either by publication of an
identical text or by endorsement, at the latest by April 2027, and conflicting national standards shall be
withdrawn at the latest by October 2027.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CEN shall not be held responsible for identifying any or all such patent rights.
This document supersedes EN 16265:2015.
— references to EU Directive 2007/23/EC have been deleted;
— forbidden substances have been moved from Clause 1 to 5.1.2;
— definition of technical documentation provided with the article has been added (3.1.5);
— definition of explosive substance has been improved (3.2.18);
— definitions of delay fuse duration, firework and pyrotechnic delay have been deleted from Clause 3;
— definitions of output effect (3.2.39) and secondary explosive (3.2.52) have been added;
— four subtypes have been added: magnetically coupled igniter (4.2.8), reactive tape (4.2.14), ignition
rod (4.2.16) and ignition stick (4.2.17);
— subtype primer has been deleted from 4.2.11;
— subclause on igniters has been revised (4.3.1);
— subclause on the NEC of the components for pyrotechnic trains has been revised (4.3.2);
— subclause on pyrotechnic cords and fuses has been revised (4.3.3);
— subclause on categorization criteria has been added for hand-held igniters (4.3.6);
— subclauses on pyrotechnic trains have been added to 4.3.7, 5.1.6 and 5.3.6;
— subclause on the use of detonative explosive substances has been added (5.1.7);
— subclause on sensitivity of pyrotechnic composition has been deleted from 5.13 and Table 1 has been
revised accordingly;
— subclause on the “use by” date has been added (5.13) and Table 1 has been revised accordingly;
— subclauses on test report have been completed (5.14.3 and 5.15.6);
— determination of all-fire / no-fire levels have been deleted from 5.15.2;
— acceptable numbers of critical and major nonconformities have been added in Table 2 (5.15.3);
— nonconformities regarding tolerances provided in the definition file of the article have been added
(5.15.4);
— subclause on the resistance of leading wires to abrasion has been revised (6.3.12);
— subclause on the slow release test has been deleted from 6.3.13.3.3;
— subclause on the electrostatic discharge has been revised (6.3.19). Table 5 on the minimum ESD
impulse has been deleted;
— subclause on the determination of the detonative / non-detonative characteristic has been revised,
depending on the test method used and if the articles contain detonative explosives (6.3.21);
— subclause on the electrostatic discharge generator has been revised (6.3.23.2);
— subclause on the details on manufacturer or importer has been deleted from 7.2.6;
— subclause on the “use by” date has been revised (7.2.6);
— text height on the transparent sheet has been changed. Figure 1 has been revised accordingly; the
subclause on printing has been revised accordingly (7.2.7);
— subclause on the marking of very small items (7.2.8) has been revised;
— Annex G has been added;
— Annex ZB has been deleted.
NOTE Words in italics (apart from document titles) are defined in Clause 3 (Terms and definitions).
This document has been prepared under a standardization request addressed to CEN by the European
Commission. The Standing Committee of the EFTA States subsequently approves these requests for its
Member States.
For the relationship with EU Legislation, see informative Annex ZA, which is an integral part of this
document.
Any feedback and questions on this document should be directed to the users’ national standards body.
A complete listing of these bodies can be found on the CEN website.
According to the CEN-CENELEC Internal Regulations, the national standards organisations of the
following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia,
Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland,
Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Republic of North
Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Türkiye and the United
Kingdom.
1 Scope
This document defines the terms and specifies the requirements, means of categorization, test methods,
minimum labelling requirements and instructions for use of the article, for ignition devices (except
ignition devices for pyrotechnic articles for vehicles) of the following generic types:
— igniters;
— components for pyrotechnic trains;
— pyrotechnic cords and fuses;
— delay fuses;
— fuzes.
NOTE Safety fuses are subject to Directive 2014/28/EU [9] and therefore not considered in this document.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments) applies.
EN 13631-3:2025, Explosives for civil uses — Explosives for blasting, boosters and explosive substances —
Part 3: Verification of the insensitiveness to friction of explosives for blasting and explosive substances
EN 13631-4:2025, Explosives for civil uses — Explosives for blasting, boosters and explosive substances —
Part 4: Verification of the insensitiveness to impact of explosives for blasting and explosive substances
EN ISO 13385-1:2019, Geometrical product specifications (GPS) — Dimensional measuring equipment —
Part 1: Design and metrological characteristics of callipers (ISO 13385-1:2019)
EN 61672-1:2013, Electroacoustics — Sound level meters — Part 1: Specifications
EN 13763-1:2025, Explosives for civil uses — Detonators and detonating cord relays — Part 1:
Requirements
EN 10088-2:2024, Stainless steels — Part 2: Technical delivery conditions for sheet/plate and strip of
corrosion resistant steels for general purposes
ISO 565:1990, Test sieves — Metal wire cloth, perforated metal plate and electroformed sheet — Nominal
sizes of openings
ISO 2859-1:2026, Sampling procedures for inspection by attributes — Part 1: Sampling schemes indexed by
acceptance quality limit (AQL) for lot-by-lot inspection
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
3.1 General terms
3.1.1
type
sample representative of the production envisaged
3.1.2
generic type
set of articles with common, very general, design features and/or with common characteristic effects
3.1.3
subtype
set of articles within a generic type with specific design features
3.1.4
individual item
article within a generic type and/or subtype for which every possible feature and characteristic has been
fixed
Note 1 to entry: Each feature and characteristic will be specified in the technical name or a technical data sheet, as
appropriate.
3.1.5
technical documentation provided with the article
all technical information about the article to be provided for EU-type examination
3.1.6
technical name
general description of an individual item
3.2 Technical terms
3.2.1
acceptance quality limit
AQL
quality level that is the worst tolerable process average when a continuing series of lots is submitted for
acceptance sampling
3.2.2
acceptor charge
acceptor component
charge of pyrotechnic composition or component receiving a stimulus from a donor charge
3.2.3
all-fire current
minimum current needed to ensure that an electric igniter is fired within a given time frame
Note 1 to entry: The minimum current is generally expressed in Amperes DC.
3.2.4
all-fire level
minimum level of the initiation input needed to ensure that an igniter or an ignition device is fired within
a given time frame
Note 1 to entry: All-fire level is a characteristic given in the instructions for use of every igniter. It is generally
associated with a probability level (e.g. 99,9 % at 95 % confidence level) within a specified time frame (e.g. 50 ms).
Note 2 to entry: Examples of initiation input are electric current in Amperes, mechanical force in Newtons, optical
power in Watts, etc.
3.2.5
ancillary equipment
any device which does not form part of a pyrotechnic article, but which is supplied with it and is required
in order that the article functions safely and correctly when used in accordance with the instructions for
use of the article
3.2.6
batch test
test performed on one or more sample(s) of products taken at random from a production batch to check
compliance with a given specification
Note 1 to entry: Batch testing needs all products in the production batch to comply with the characteristics this
document requires to ensure homogeneity of the whole batch. It aims at proving all products which are placed on
the market are in conformity with the type which is described in the EU-type examination certificate and have been
successfully submitted to type tests determined by this document.
3.2.7
black powder
intimate mixture of charcoal and sodium nitrate or potassium nitrate with or without sulphur
3.2.8
booster
pyrotechnic device used as a donor charge to amplify the energy supplied to the acceptor charge
3.2.9
bridgewire
resistive element connecting the leading wires inside an electric igniter
3.2.10
burning time
time in seconds for a defined mass or length of pyrotechnic composition to burn from its ignition to its
consumption
3.2.11
critical nonconformity
nonconformity that judgement and experience indicate is likely to result in hazardous or unsafe
conditions
Note 1 to entry: This type of nonconformity is referred to as a “class A nonconformity” in ISO 2859-1:2026.
3.2.12
critical nonconforming unit
nonconforming unit with one or more critical nonconformities, with or without major or minor
nonconformities
3.2.13
deflagration
reaction of fast combustion through a pyrotechnic composition at subsonic velocity in the reacting
explosive substance
3.2.14
detonation
reaction which propagates through an explosive substance at supersonic velocity in the reacting material
3.2.15
detonative explosive
explosive substance which can undergo a fast-internal decomposition reaction leading to a detonation in
normal use
3.2.16
donor charge
charge of pyrotechnic composition supplying a stimulus to an acceptor charge
3.2.17
electrostatic discharge
ESD
sudden and momentary electric current that flows between two objects at different electrical potentials
3.2.18
explosive substance
solid or liquid substance or a mixture of substances which is in itself capable by chemical reaction of
producing gas at such a temperature and pressure and at such a speed as to cause damage to the
surroundings
Note 1 to entry: Pyrotechnic substances are included even when they do not evolve gases.
3.2.19
firing current
constant electrical direct current required to reliably initiate functioning of an electric igniter
3.2.20
friction head
ignition head designed to be ignited by friction
3.2.21
fusehead
part of an electric igniter consisting of one or more pairs of metal conductors, bridged by fine resistance
wire(s), and coated with a pyrotechnic composition which initiates when the firing current is passed
through the bridgewire(s)
3.2.22
gross mass
total mass of a pyrotechnic article, not including any ancillary equipment
3.2.23
ignition head
initial fuse consisting of pyrotechnic composition only
3.2.24
ignition tube
tube usually containing a thin pyrotechnic charge on the inner wall capable on activation of transmitting
a deflagration effect from one end of the tube to the other at a subsonic velocity
3.2.25
incompatible substances
materials that undergo chemical reaction together resulting in unsafe conditions
3.2.26
linear burning rate
length of pyrotechnic composition in millimetres or metres divided by the burning time in seconds
3.2.27
main charge
pyrotechnic composition which produces the principal effect
3.2.28
major nonconformity
nonconformity, other than a critical nonconformity, which is likely to result in failure, to reduce materially
the usability of the pyrotechnic article, or to increase the potential hazard
Note 1 to entry: This type of nonconformity is referred to as a “class B nonconformity” in ISO 2859-1:2026.
3.2.29
major nonconforming unit
nonconforming unit with one or more major nonconformities, with or without minor nonconformities, but
with no critical nonconformities
3.2.30
minor nonconformity
nonconformity that is not likely to reduce materially the usability of the pyrotechnic article
Note 1 to entry: This type of nonconformity is referred to as a “class C nonconformity” in ISO 2859-1:2026.
3.2.31
minor nonconforming unit
nonconforming unit with one or more minor nonconformities, but with no critical or major nonconformities
3.2.32
misfire
incomplete functioning or non-functioning of a pyrotechnic article after application of initiation stimulus
3.2.33
net explosive content
NEC
total mass of explosive substance in a pyrotechnic article
3.2.34
no-fire current
maximum current that can be applied without causing an electric igniter to function within a specified
time period
Note 1 to entry: The maximum current is generally expressed in Amperes DC.
3.2.35
no-fire level
maximum level of the initiation input that can be applied without causing an igniter to function within a
specified time period
Note 1 to entry: No-fire level is a characteristic given in the instructions for use of every igniter. It is generally
associated with a probability level (e.g. 99,9 % at 95 % confidence level) within a specified time frame (e.g. 50 ms).
Note 2 to entry: Examples of initiation input are electric current in Amperes, mechanical force in Newtons, optical
power in Watts, etc.
3.2.36
nonconforming unit
pyrotechnic article with one or more nonconformities
3.2.37
nonconformity
non-fulfilment of a requirement
[SOURCE: EN ISO 9000:2026, 3.5.13 [1]]
3.2.38
other pyrotechnic article
pyrotechnic article other than fireworks, theatrical pyrotechnic articles and pyrotechnic articles for
vehicles
3.2.39
output effect
final effect used to initiate or transmit ignition to another pyrotechnic article
3.2.40
“pin-to-case” configuration
configuration in which the ESD occurs between the two short-circuited leading wire ends and the igniter
casing or between the pins and the casing of the connector of the igniter
3.2.41
“pin-to-pin” configuration
configuration in which the ESD occurs through the bridgewire of the igniter
3.2.42
primary pack
package of one or more pyrotechnic articles, offered for retail sale as a single unit
Note 1 to entry: A primary pack is neither necessarily the smallest piece of packaging nor a full enclosure: for
instance, pyrotechnic cords and fuses are often delivered coiled around a reel as the smallest piece of retail sale.
3.2.43
principal effect
main effect a pyrotechnic article is designed to produce
3.2.44
pyrotechnic component
any component of a pyrotechnic article which contains one or more pyrotechnic compositions
3.2.45
pyrotechnic composition
explosive substance or mixture of explosive substances which is designed, on ignition or initiation, to
produce heat, light, sound, gas or smoke or a combination of such effects through self-sustained
exothermic chemical reactions
3.2.46
pyrotechnic device
any device containing pyrotechnic composition(s) which determine its principal effect
3.2.47
pyrotechnic operation
any operation which leads to the direct application of a mechanical, thermal and/or chemical stress on a
pyrotechnic composition without intending to ignite or initiate the article at the time the stress is applied
3.2.48
relay
charge of pyrotechnic composition that is used to transmit ignition
3.2.49
safe test current
maximum electrical current that can be applied without causing an electric igniter to function regardless
of the duration
Note 1 to entry: The electrical current is generally expressed in Amperes DC.
3.2.50
safety friction tip
friction head that can only be ignited when rubbed against a striker component containing a chemical
substance with which it reacts, such as red phosphorus, or a combination of such a chemical substance
and an abrasive surface
3.2.51
safety fuse
article consisting of a core of fine-grained black powder surrounded by a flexible woven fabric with one
or more protective coverings
Note 1 to entry: Other names are safety cord, fuse cord, mine or mining fuse. This article is the subject of
Directive 2014/28/EU and the corresponding European Standards EN 13630 series [2].
3.2.52
secondary explosive
detonative explosive that is insensitive to heat or handling impact but will detonate under strong shock
impulse
[SOURCE: ISO 26871:2020, 3.1.54 [3], modified – “detonative” has been added and “material” has been
deleted]
3.2.53
slag
condensed reaction products resulting from the combustion of pyrotechnic composition(s)
3.2.54
type test
test performed on a sample of products, representative of the production envisaged
Note 1 to entry: The test is intended to demonstrate the compliance of the sample with the essential safety
requirements of Annex I and the relevant provisions of Directive 2013/29/EU [8].
Note 2 to entry: The successful submission to type tests leads to the attribution of an EU-type examination
certificate.
3.2.55
“use by” date
latest date by which an article shall be used if it is to safely exhibit the performance characteristics
described in the technical specifications of the article
4 Categories and types of ignition devices
4.1 Generic types
The generic types are defined as follows:
4.1.1 Igniter: Article containing pyrotechnic composition(s) used to initiate combustion or deflagration.
They may be actuated by chemical, electrical, optical or mechanical means.
NOTE Complex igniters (e.g. some integral rocket igniters) are not considere
...