EN 627:1995
(Main)Specification for data logging and monitoring of lifts, escalators and passenger conveyors
- BACK
- 22-Aug-1995
- 27-Feb-1996
- 91.140.90
- 2014/33/EU
- 89/392/EEC
- 95/16/EC
- 98/37/EC
- M/079
- M/BC/CEN/92/3
- CEN/TC 10
Specification for data logging and monitoring of lifts, escalators and passenger conveyors
This European Standard specifies the fundamental characteristics of data logging and monitoring systems for lift, escalator and passenger conveyor installations.
Regeln für Datenerfassung und Fernüberwachung von Aufzügen, Fahrtreppen und Fahrsteigen
Diese Europäische Norm behandelt die grundlegenden Eigenschaften von Systemen zur Datenerfassung und Fernüberwachung von Aufzügen, Fahrtreppen und Fahrsteigen.
Règles pour l'enregistrement de données et la surveillance des ascenceurs, escaliers mécaniques et trottoirs roulants
La présente norme européenne spécifie les caractéristiques de base des dispositifs d'enregistrement de données et de surveillance des ascenceurs, escaliers mécaniques et trottoirs roulants.
Pravila za zajemanje podatkov in daljinski nadzor dvigal, tekočih stopnic in trakov za osebe
General Information
Standards Content (Sample)
SLOVENSKI STANDARD
01-avgust-1997
3UDYLOD]D]DMHPDQMHSRGDWNRYLQGDOMLQVNLQDG]RUGYLJDOWHNRþLKVWRSQLFLQWUDNRY
]DRVHEH
Specification for data logging and monitoring of lifts, escalators and passenger
conveyors
Regeln für Datenerfassung und Fernüberwachung von Aufzügen, Fahrtreppen und
Fahrsteigen
Regles pour l'enregistrement de données et la surveillance des ascenceurs, escaliers
mécaniques et trottoirs roulants
Ta slovenski standard je istoveten z: EN 627:1995
ICS:
91.140.90 'YLJDOD7HNRþHVWRSQLFH Lifts. Escalators
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
...
This May Also Interest You
1.1 This draft European Standard deals with safety requirements for construction, manufacturing, installation, maintenance and dismantling of electrically powered vertical lifting platforms affixed to a building structure intended for use by persons with impaired mobility:
- travelling vertically between predefined levels along a guided path whose inclination to the vertical does not exceed 15°;
- intended for use by persons with or without a wheelchair;
- supported or sustained by rack and pinion, rope traction drive, noncircular elastomeric-coated steel suspension members (hereafter called flat belt) traction drive, rope positive drive, chains, toothed belts, screw and nut, guided chain, scissors mechanism or hydraulic jack (direct or indirect);
- with enclosed liftways;
- with a speed not greater than 0,15 m/s;
- with platforms where the carrier is not completely enclosed.
1.2 This draft European Standard deals with all significant hazards relevant to lifting platforms, when they are used as intended and under the conditions foreseen by the manufacturer (see Clause 4).
1.3 This draft European Standard does not specify the additional requirements for:
- operation in severe conditions (e.g. extreme climates, strong magnetic fields);
- lightning protection;
- operation subject to special rules (e.g. potentially explosive atmospheres);
- handling of materials, the nature of which could lead to dangerous situations;
- vertical lifting platforms whose primary function is the transportation of goods;
- vertical lifting platforms whose carriers are completely enclosed;
- vertical lifting platforms prone to vandalism;
- hazards occurring during manufacture;
- earthquakes, flooding;
- firefighting, evacuation and behaviour during a fire;
- noise and vibrations;
- the design of concrete, hard core, timber or other foundation or building arrangement;
- the design of anchorage bolts to the supporting structure;
- type C wheelchairs as defined in EN 12183 and/or EN 12184.
NOTE For the actual type of machinery, noise is not considered a significant nor relevant hazard.
1.4 This draft European Standard is not applicable to Vertical Lifting Platforms intended for use by persons with impaired mobility which are manufactured before the date of its publication as an EN.
- Draft109 pagesEnglish languagesale 10% offe-Library read for×1 day
- 26-Nov-2024
- 24-Apr-2022
- 11.180.10
- 91.140.90
- 2006/42/EC
- M/396
- CEN/TC 10
1.1 This document specifies the safety rules for new accessible goods only lifts with traction, positive or hydraulic drive, permanently installed and only used by users (see 3.57), serving fixed and permanent landing levels, having a carrier made of a single load carrying area, designed for the transportation of goods only, moving along a fixed path by rigid guide rails and inclined not more than 15° to the vertical, with rated speed not exceeding 1 m/s.
This document covers accessible goods only lifts with rated load exceeding 300 kg and not intended to transport persons.
1.2 For the purpose of this document, a goods only lift carrier is regarded as accessible where one of the following conditions is satisfied:
a) floor area of the carrier is greater than 1,0 m2;
b) depth of the carrier is greater than 1,0 m;
c) clear height of the carrier is greater than 1,20 m.
In case the carrier is without a roof, it is considered accessible when the clear height of the landing doors is greater than 1,20 m.
1.3 Two types of accessible goods only lifts are addressed:
a) Type A, where the intended use is bound to the maximum rated speed of 0,30 m/s;
b) Type B, where the intended use is bound to the maximum rated speed of 1,0 m/s.
1.4 In addition to the requirements of this document, supplementary requirements are to be considered in special cases (operation subject to ATEX rules, operational in ambiental condition not addressed by this standard, seismic conditions, transporting dangerous goods, etc.).
1.5 This document does not cover:
a) accessible goods only lifts:
1) with more than one lift machine;
i) where loading and unloading is automated, or the carrier floor is fitted with mobile devices (e.g. rollers) for loading and unloading purposes;
ii) intended to carry bulk loads (such as loose sand, gravel, etc.);
iii) with drive systems other than those stated in 4.8;
b) lifting tables according to EN 1570-1 and EN 1570-2;
c) lifting appliances, such as appliances with more than one carrier, skips, goods only lifts for construction sites, for underground applications, mine winding gear, goods only lifts on seagoing vessels and mobile offshore units, construction and maintenance appliances in wind turbines, goods only lifts specially designed and constructed for research purposes for temporary use in laboratories, goods only lifts specially designed and constructed for military or police purposes;
d) safety during operation of transport, erection, repairs and dismantling of accessible goods only lifts;
e) the use of translucent material for the walls of the well and machinery spaces, for the carrier with the exception of the landing doors vision panels;
f) the use of programmable electronic systems in safety related applications for lifts (PESSRAL);
g) hydraulic lifts where the setting of the pressure relief valve exceeds 50 MPa;
h) any form of radiation except EMC;
i) fire propagation;
j) energy dissipation type buffers;
k) the possibility of two simultaneous acts of imprudence and/or the abuse of instructions for use.
l) ambient temperature in the well and machinery spaces lower than +5 °C and higher than +40 °C;
m) health and safety of animals.
However, this document can usefully be taken as a basis.
Noise and vibrations are not dealt with in this document as they are not considered a significant nor relevant hazard for the actual type of the accessible goods only lifts.
1.6 The requirements of this document are such that the possibility of a failure of an electric safety device or a safety component complying with all the requirements of this document needs not to be taken into consideration.
1.7 This document is not applicable to accessible goods only lifts which were manufactured before the date of its publication as EN.
- Draft189 pagesEnglish languagesale 10% offe-Library read for×1 day
- 12-Nov-2024
- 91.140.90
- 2006/42/EC
- M/008
- M/396
- CEN/TC 10
1.1 This document specifies the safety requirements for the construction and installation of power operated lifting appliances installed permanently for indoor or outdoor service in wind turbines and intended for access to workplaces on wind turbines, including rescue and evacuation procedures. A lifting appliance serves defined landing levels and can move persons to working positions where they are carrying out work (which could be from the carrier) and has a carrier which is:
a) designed for the transportation of persons and goods;
b) guided;
c) travelling vertically or along a path within 15° maximum from the vertical;
d) supported or sustained by rack and pinion or rope traction drive;
e) travelling with a speed not more than 0,7 m/s;
f) able to operate in a temperature range between - 25 °C to + 55 °C.
1.2 This document does not cover hazards related to:
a) noise;
b) the use of the lifting appliance for erection or dismantling of the wind turbine;
c) lightning protection;
d) use in potentially explosive atmospheres;
e) electromagnetic compatibility (emission, immunity);
f) transporting of goods outside the carrier;
g) the use of combustion engines;
h) hydraulic and pneumatic drive units;
i) the use of lifting appliances in floating wind turbines;
j) use during earthquakes.
1.3 This document is not applicable to lifting appliances manufactured before the date of its publication.
- Draft118 pagesEnglish languagesale 10% offe-Library read for×1 day
- 30-Jul-2024
- 27.180
- 91.140.90
- 2006/42/EC
- M/396
- CEN/TC 10
1.1 This document specifies power operated temporarily installed builders’ hoists (referred to as “hoists” in this document) intended for use by persons who are permitted to enter sites of engineering and construction, serving landing levels, having a cage:
- designed for the transportation of persons or of persons and materials;
- guided;
- travelling vertically or along a path within 15° max. of the vertical;
- supported or sustained by rack and pinion;
- designed with and / or without support from separate structure.
1.2 This document specifies the significant hazards, hazardous situations or hazardous events relevant to the machine as listed in Annex C which arise during the various phases in the life of the machine and describes methods for the elimination or reduction of these hazards when it is used as intended and under conditions of misuse which are reasonably foreseeable by the manufacturer.
1.3 This document does not specify the additional requirements for:
- operation in severe conditions (e.g. extreme climates, strong magnetic fields);
- lightning protection;
- operation subject to special rules (e.g. potentially explosive atmospheres);
- electromagnetic compatibility (emission, immunity);
- handling of loads the nature of which could lead to dangerous situations (e.g. molten metal, acids/bases, radiating materials, fragile loads);
- the use of combustion engines;
- the use of remote controls;
- hazards occurring during manufacture;
- hazards occurring as a result of mobility;
- hazards occurring as a result of being erected over a public road;
- earthquakes;
- emission of airborne noise;
- dual (twin) cage hoists;
- twin masts hoists;
- combination hoists, e.g. an EN 12159 hoist with an EN 12158-1 hoist;
- counterweighted hoists, neither by separate counterweight nor counterweighted by another cage.
1.4 This document does not apply to:
- builders’ hoists for the transport of goods only EN 12158-1:2021 and EN 12158-2:2000+A1:2010;
- lifts according to EN 81-20:2020, EN 81-3:2000+A1:2008 and EN 81-43:2009;
- work cages suspended from lifting appliances;
- work platforms carried on the forks of fork trucks;
- work platforms according to EN 1495:1997+A2:2009 ;
- transport platforms according to EN 16719:2018;
- funiculars;
- lifts specially designed for military purposes;
- mine lifts;
- theatre elevators;
- hoists with hydraulic drive/braking systems and hydraulic safety devices.
1.5 This document specifies the hoist installation. It includes the base frame and base enclosure but excludes the design of any concrete, hard core, timber or other foundation arrangement. It includes the design of mast ties but excludes the design of anchor bolts to the supporting structure. It includes the landing gates and their frames but excludes the design of any anchorage fixing bolts to the supporting structure.
1.6 This document does not apply to builders’ hoists for persons and material with vertically guided cages which are manufactured before the date of publication of this document by CEN.
- Standard68 pagesEnglish languagesale 10% offe-Library read for×1 day
- 09-Jul-2024
- 91.140.90
- 2006/42/EC
- M/396
- CEN/TC 10
- Amendment8 pagesEnglish languagesale 10% offe-Library read for×1 day
This document specifies:
a) methods of measuring actual energy consumption of lifts, escalators and moving walks on a single unit basis;
b) methods of carrying out periodic energy verification checks on lifts, escalators and moving walks in operation.
This document only considers the energy performance during the operational portion of the life cycle of the lifts, escalators or moving walks.
For lifts, this document does not cover energy aspects, such as:
a) hoistway lighting;
b) heating and cooling equipment, including fans in the lift car;
c) machine room lighting;
d) machine room heating, ventilation and air conditioning;
e) non-lift, display systems, closed circuit television security cameras, etc.;
f) non-lift, monitoring systems (building management systems, etc.);
g) the effect of lift group dispatching on energy consumption;
h) non-lift equipment consumption through the power sockets;
i) energy storage systems if used as an alternative energy source for operation.
For escalators and moving walks, this document does not cover energy aspects of the ancillary equipment, such as:
a) lighting with the exception of comb plate lighting and step gap lighting and traffic light;
b) cooling and heating;
c) alarm devices and emergency battery supplies equipment, etc.
- Standard25 pagesEnglish languagesale 10% offe-Library read for×1 day
This document specifies the minimum requirements for the safe and independent access and use of lifts by persons, including persons with disabilities. It covers the needs of persons with disabilities according to Annex A.
NOTE For guidance on solutions for increased accessibility and usability, see Annex D
- Standard33 pagesEnglish languagesale 10% offe-Library read for×1 day
- 05-Jul-2022
- 91.140.90
- 2014/33/EU
- 2016/797/EU
- M/549
- CEN/TC 10
This document specifies the technical requirements for the alarm systems for passenger and goods passenger lifts, as described in the EN 81 series.
This includes:
- activation of the alarm,
- transmission of the alarm,
- information for use and maintenance,
- site testing to verify the requirements of this document have been met before the lift is used.
Excluded are:
- the failure of the communication network (see Annex A), including mobile network signal strength or similar;
- the failure of the network power supply such that all the lifts in a geographical area create entrapment simultaneously.
This document deals with the following significant hazards, hazardous situations or hazardous events relevant to lift, when it is used as intended and under conditions of misuse which are reasonably foreseeable by the manufacturer:
- risk of entrapment of users in the car and in the well.
This document is not applicable to alarm systems for lifts installed before the date of its publication.
- Standard20 pagesEnglish languagesale 10% offe-Library read for×1 day
- 07-Jun-2022
- 13.320
- 91.140.90
- 2014/33/EU
- M/549
- CEN/TC 10
This document specifies the safety rules related to passenger and goods/passenger lifts installed in existing buildings where limitations enforced by certain building constraints mean that some requirements of EN 81-20:2020 cannot be met.
It addresses the following constraints and gives requirements for alternative solutions:
- existing perforate walls of the lift well;
- reduction in available well are leading to reduced distance between car, counterweight or balancing weight;
- counterweight or balancing weight in a separate existing well;
- reduced building dimensions and clearances leading to:
- reductions in available space for headroom and pit;
- reduced car roof balustrade dimensions;
- reduced height of sill apron;
- reduced height of machine and/or pulley room;
- reduced available area for access door/trap door;
- reduction in available height of landing doors.
This document is not applicable to lifts installed before the date of its publication.
- Standard34 pagesEnglish languagesale 10% offe-Library read for×1 day
- 24-May-2022
- 91.140.90
- 2014/33/EU
- M/549
- CEN/TC 10
This document specifies the fire resistance requirements for lift landing doors which are intended to provide a barrier to the spread of fire from the landing side and via the lift well in buildings during a defined period of time. The fire resistance requirements are expressed in terms of integrity (E), insulation (EI) and radiation (EW).
It is applicable to lift landing doors installed in the lift well openings at landings and used as means of access to lift car.
It also specifies the method of testing and classification of fire resistance of lift landing doors. The test method is only valid for furnaces where the door is mounted in a vertical position. The test method specifies the measurement of integrity and if required the measurement of radiation and thermal insulation.
This document does not cover other technical requirements in addition to fire resistance requirements.
This document refers to CO2 as means of tracing the propagation of fire. The document does not cover hazards due to emission of gases.
This document is not applicable to lifts which are installed before the date of its publication.
- Standard34 pagesEnglish languagesale 10% offe-Library read for×1 day
- 24-May-2022
- 13.220.20
- 91.140.90
- 2014/33/EU
- M/549
- CEN/TC 10
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.