Thermal insulation products for buildings - Factory made mineral wool (MW) products - Specification

This European Standard specifies the requirements for factory made mineral wool products, with or without facings or coatings, which are used for the thermal insulation of buildings. The products are manufactured in the mat blankets, boards or slabs.
Products covered by this standard are also used in prefabricated thermal insulation systems and composite panels; the performance of systems incorporating these products is not covered.
This standard describes product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling.
This standard does not specify the required level of a given property to be achieved by a product to demonstrate fitness for purpose in a particular application. The levels required for a given application are to be found in regulations or non-conflicting standards.
Products with a declared thermal resistance lower than 0,25 m2K/W or a declared thermal conductivity greater than 0,060 W/(mK) at 10 °C are not covered by this standard.
This standard does not cover in situ insulation products (covered by EN 14064 parts 1 and 2) and products intended to be used for the insulation of building equipment and industrial installations (covered by EN 14303).

Wärmedämmstoffe für Gebäude - Werkmäßig hergestellte Produkte aus Mineralwolle (MW) - Spezifikation

Diese Europäische Norm legt die Anforderungen an werkmäßig hergestellte Produkte aus Mineralwolle mit oder ohne Kaschierung oder Beschichtung fest, die für die Wärmedämmung von Gebäuden benutzt werden. Die Produkte werden in Form von Matten oder Platten hergestellt.
Die in dieser Norm beschriebenen Produkte werden auch in vorgefertigten Wärmedämmsystemen und Mehrschicht Platten angewendet. Die Eigenschaften von Systemen, in die diese Produkte integriert sind, werden nicht behandelt.
Die vorliegende Norm beschreibt die Produkteigenschaften und enthält die Prüfverfahren und Festlegungen für die Konformitätsbewertung, die Kennzeichnung und die Etikettierung.
Diese Norm legt keine Leistungsstufen für eine vorgegebene Eigenschaft fest, die ein Produkt erreichen muss, um für einen bestimmten Anwendungsfall tauglich zu sein. Die für bestimmte Anwendungen benötigten Stufen können Regelwerken oder nicht entgegenstehenden Normen entnommen werden.
Diese Norm gilt nicht für Produkte, deren Nennwert des Wärmedurchlasswiderstandes niedriger als 0,25 m2K/W oder deren Nennwert der Wärmeleitfähigkeit größer als 0,060 W/(mK) bei 10 °C ist.
Die vorliegende Norm gilt weder für in situ Dämmprodukte (durch EN 14064-1 und EN 14064-2 abgedeckt) noch für Produkte, die zur Dämmung von haus¬technischen und betriebstechnischen Anlagen (durch EN 14303 abgedeckt) vorgesehen sind.

Produits isolants thermiques pour le bâtiment - Produits manufacturés en laine minérale (MW) - Spécification

La présente Norme européenne spécifie les exigences auxquelles doivent satisfaire les produits manufacturés en laine minérale, avec ou sans parements ou enduits de finition, utilisés pour l'isolation thermique des bâtiments. Les produits sont fabriqués sous forme de feutres, panneaux ou plaques.
Les produits couverts par la présente norme sont également utilisés dans des systèmes d'isolation thermique et dans des panneaux composites préfabriqués ; les performances des systèmes incorporant ces produits ne sont pas définies.
La présente norme décrit les caractéristiques des produits et contient des modes opératoires d'essai, d'évaluation de la conformité, de marquage et d'étiquetage.
La présente norme ne spécifie pas, pour une propriété donnée, le niveau exigé que doit atteindre un produit pour démontrer son aptitude à l'emploi dans une application particulière. Les niveaux requis pour une application donnée figurent dans les réglementations ou les normes non conflictuelles.
Les produits dont la résistance thermique déclarée à une température de 10 °C est inférieure à 0,25 m2×K/W ou dont la conductivité thermique déclarée à une température de 10 °C est supérieure à 0,060 W/(m×K) ne relèvent pas du domaine d'application de la présente norme.
Les produits isolants mis en oeuvre in situ (couverts par les parties 1 et 2 de l’EN 14604) et les produits destinés à être utilisés pour l'isolation des équipements du bâtiment et des installations industrielles (couverts par l’EN 14303) ne relèvent pas du domaine d'application de la présente norme.

Toplotnoizolacijski proizvodi za stavbe - Proizvodi iz mineralne volne (MW) - Specifikacija

Ta evropski standard določa zahteve za površinsko obdelane ali lakirane ali površinsko neobdelane ali nelakirane proizvode iz mineralne volne, ki se uporabljajo za toplotno izolacijo stavb. Proizvodi so izdelani v obliki kolutov, plošč ali blokov.
Proizvodi iz tega standarda se uporabljajo tudi v predizdelanih sistemih toplotne izolacije in vezanih ploščah; lastnosti sistemov iz teh proizvodov niso opisane.
Ta standard opisuje lastnosti proizvodov ter zajema postopke za preskušanje, vrednotenje skladnosti, označevanje in etiketiranje.
Ta standard ne določa zahtevane ravni določene lastnosti, ki jo mora proizvod doseči, da se dokaže njegova primernost namenu za posamezno vrsto uporabe. Zahtevane ravni za posamezno uporabo so določene v uredbah ali standardih, ki niso v nasprotju s tem standardom.
Proizvodi z deklarirano toplotno upornostjo, nižjo od 0,25 m2K/W, ali deklarirano toplotno prevodnostjo, višjo od 0,060 W/(mK) pri 10 °C, v tem standardu niso zajeti.
Ta standard ne zajema toplotnoizolacijskih proizvodov, izdelanih na kraju samem (zajema jih standard EN 14064, dela 1 in 2), ter proizvodov, namenjenih za izolacijo gradbene opreme in industrijskih napeljav (zajema jih standard EN 14303).

General Information

Status
Published
Publication Date
17-Feb-2015
Current Stage
9093 - Decision to confirm - Review Enquiry
Start Date
04-May-2022
Completion Date
14-Apr-2025

Relations

Effective Date
19-Jan-2023
Effective Date
19-Jan-2023
Effective Date
06-Sep-2017

Overview - EN 13162:2012+A1:2015 (Factory made mineral wool products)

EN 13162:2012+A1:2015 is the CEN specification for factory made mineral wool (MW) products used for thermal insulation in buildings. It applies to mineral wool supplied as mat/blankets, boards or slabs, with or without facings or coatings. The standard defines product characteristics and procedures for testing, conformity assessment (AVCP), marking and labelling, but it does not prescribe application-specific performance levels - those are set by regulations or other non-conflicting standards.

Important scope notes:

  • Covers factory made mineral wool products used in building insulation and in prefabricated systems or composite panels (but not the performance of the whole system).
  • Excludes in situ insulation (see EN 14064 parts 1 & 2) and insulation for building equipment/industrial installations (EN 14303).
  • Products with declared thermal resistance < 0.25 m²·K/W or declared thermal conductivity > 0.060 W/(m·K) at 10 °C are outside the scope.

Key topics and technical requirements

EN 13162 addresses the following technical topics and referenced test methods:

  • Thermal performance: determination of thermal resistance and thermal conductivity (linked to EN 12667, EN 12939 and Annex A).
  • Dimensional and mechanical properties: thickness, length/width, flatness, squareness, compressibility, compressive creep (EN 822–EN 826, EN 1604–EN 1606).
  • Water and moisture behaviour: short/long term water absorption, water vapour transmission (EN 1609, EN 12086, EN 12087).
  • Fire reaction and classification: links to reaction-to-fire tests and EN 13501-1; includes provisions for CE marking under the Construction Products Regulation (Annex ZA).
  • Durability and organic content: organic content determination (EN 13820) and other quality checks.
  • Acoustic properties: referenced methods for airflow resistance and sound absorption (EN ISO 354, EN 29053, EN 29052-1).
  • Conformity & factory production control (FPC): assessment methods, designation code, marking and labelling (Clauses 7–8, Annex B).

Applications and who uses EN 13162

EN 13162 is essential for:

  • Manufacturers of mineral wool products to specify product characteristics, testing and FPC.
  • Testing laboratories performing thermal, mechanical, fire and moisture tests referenced in the standard.
  • Specifiers, architects and consultants selecting factory made MW products for building walls, roofs and floors.
  • Regulators and certification bodies assessing conformity with the EU Construction Products Regulation (CPR) and CE marking.
  • Product certifiers and supply chain stakeholders ensuring declared values and labelling meet EU requirements.

Related standards

  • EN 13163 – EPS products; EN 13164 – XPS; EN 13165 – PU; EN 13171 – wood fibre, etc. (insulation standards package)
  • EN 14064 (in situ insulation), EN 14303 (industrial insulation)
  • EN 13501-1 (fire classification), EN 15715 (mounting for reaction-to-fire testing)

Keywords: EN 13162, mineral wool, factory made mineral wool, thermal insulation standard, CEN, MW products, building insulation, AVCP, CE marking.

Standard

EN 13162:2013+A1:2015

English language
47 pages
Preview
Preview
e-Library read for
1 day

Frequently Asked Questions

EN 13162:2012+A1:2015 is a standard published by the European Committee for Standardization (CEN). Its full title is "Thermal insulation products for buildings - Factory made mineral wool (MW) products - Specification". This standard covers: This European Standard specifies the requirements for factory made mineral wool products, with or without facings or coatings, which are used for the thermal insulation of buildings. The products are manufactured in the mat blankets, boards or slabs. Products covered by this standard are also used in prefabricated thermal insulation systems and composite panels; the performance of systems incorporating these products is not covered. This standard describes product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling. This standard does not specify the required level of a given property to be achieved by a product to demonstrate fitness for purpose in a particular application. The levels required for a given application are to be found in regulations or non-conflicting standards. Products with a declared thermal resistance lower than 0,25 m2K/W or a declared thermal conductivity greater than 0,060 W/(mK) at 10 °C are not covered by this standard. This standard does not cover in situ insulation products (covered by EN 14064 parts 1 and 2) and products intended to be used for the insulation of building equipment and industrial installations (covered by EN 14303).

This European Standard specifies the requirements for factory made mineral wool products, with or without facings or coatings, which are used for the thermal insulation of buildings. The products are manufactured in the mat blankets, boards or slabs. Products covered by this standard are also used in prefabricated thermal insulation systems and composite panels; the performance of systems incorporating these products is not covered. This standard describes product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling. This standard does not specify the required level of a given property to be achieved by a product to demonstrate fitness for purpose in a particular application. The levels required for a given application are to be found in regulations or non-conflicting standards. Products with a declared thermal resistance lower than 0,25 m2K/W or a declared thermal conductivity greater than 0,060 W/(mK) at 10 °C are not covered by this standard. This standard does not cover in situ insulation products (covered by EN 14064 parts 1 and 2) and products intended to be used for the insulation of building equipment and industrial installations (covered by EN 14303).

EN 13162:2012+A1:2015 is classified under the following ICS (International Classification for Standards) categories: 91.100.60 - Thermal and sound insulating materials. The ICS classification helps identify the subject area and facilitates finding related standards.

EN 13162:2012+A1:2015 has the following relationships with other standards: It is inter standard links to EN 13162:2012, EN 13162:2012/FprA1, EN 13162:2012+A1:2015/FprA2. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

EN 13162:2012+A1:2015 is associated with the following European legislation: EU Directives/Regulations: 305/2011; Standardization Mandates: M/103. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.

You can purchase EN 13162:2012+A1:2015 directly from iTeh Standards. The document is available in PDF format and is delivered instantly after payment. Add the standard to your cart and complete the secure checkout process. iTeh Standards is an authorized distributor of CEN standards.

Standards Content (Sample)


2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Toplotnoizolacijski proizvodi za stavbe - Proizvodi iz mineralne volne (MW) - SpecifikacijaWärmedämmstoffe für Gebäude - Werkmäßig hergestellte Produkte aus Mineralwolle (MW) - SpezifikationProduits isolants thermiques pour le bâtiment - Produits manufacturés en laine minérale (MW) - SpécificationThermal insulation products for buildings - Factory made mineral wool (MW) products - Specification91.100.60Thermal and sound insulating materialsICS:Ta slovenski standard je istoveten z:EN 13162:2012+A1:2015SIST EN 13162:2013+A1:2015en,fr,de01-april-2015SIST EN 13162:2013+A1:2015SLOVENSKI
STANDARDSIST EN 13162:20131DGRPHãþD

EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 13162:2012+A1
February 2015 ICS 91.100.60 Supersedes EN 13162:2012English Version
Thermal insulation products for buildings - Factory made mineral wool (MW) products - Specification
Produits isolants thermiques pour le bâtiment - Produits manufacturés en laine minérale (MW) - Spécification
Wärmedämmstoffe für Gebäude - Werkmäßig hergestellte Produkte aus Mineralwolle (MW) - Spezifikation This European Standard was approved by CEN on 6 October 2012 and includes Amendment 1 approved by CEN on 15 December 2014.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre:
Avenue Marnix 17,
B-1000 Brussels © 2015 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 13162:2012+A1:2015 ESIST EN 13162:2013+A1:2015

Determination of the declared values of thermal resistance and
thermal conductivity . 23 Annex B (normative)
!Product type determination" (!PTD") and factory production control (FPC) . 26 Annex C (normative)
MW multi-layered insulation products . 31 Annex D (informative)
Examples for the determination of the declared values of thermal resistance and thermal conductivity for a product or a product group . 33 Annex ZA (informative)
!Clauses of this European Standard addressing the provisions of the EU Construction Products Regulation . 36 Bibliography . 47
Tables Table 1 — Level and classes for thickness tolerances. 12 Table 2 — Dimensional stability under specified temperature and humidity conditions . 14 Table 3 — Classes for thickness tolerances . 16 Table 4 — Levels for compressibility . 16 Table 5 — Test methods, test specimens and conditions. 19 Table A.1 — Values for k for one sided 90 % tolerance interval with a confidence level of 90 % . 25 Table B.1 — Minimum number of tests for !PTD" and minimum product testing frequencies . 26 Table B.2 — Minimum product testing frequencies for the reaction to fire characteristics . 28 Table D.1 —
test results . 33 Table D.2 — R test results . 34 Table ZA.1 — Relevant clauses for factory made mineral wool and intended use . 36 Table ZA.2 — Systems of AVCP . 38 Table ZA.3.1 — Assignment of AVCP tasks for factory made mineral wool products under system 1 for reaction to fire and system 3 (see Table ZA.2) . 38 Table ZA.3.2 — Assignment of AVCP tasks for factory made mineral wool products under system 3 (see Table ZA.2) . 40 SIST EN 13162:2013+A1:2015

Figures Figure ZA.1 — Example CE marking information of products under AVCP system 1 and system 3" . 46
load of 48 kPa mm dL is the thickness under a load of 250 Pa mm dN is the nominal thickness of the product mm û0b is the relative change in width % û0d is the relative change in thickness % û0l is the relative change in length % û0s is the relative change in flatness mm/m Fp is the point load at a given deformation N k is a factor related to the number of test results – l is the length mm
is the thermal conductivity W/(m„K) 90/90 is a 90 % fractile with a confidence level of 90 % for the thermal conductivity W/(m„K) D is the declared thermal conductivity W/(m„K) i is one test result of thermal conductivity W/(m„K) mean is the mean thermal conductivity W/(m„K) U is the design thermal conductivity W/(m„K)
is the water vapour diffusion resistance factor – N is the number of test results – R90/90 is a 90 % fractile with a confidence level of 90 % for the thermal resistance m2„K/W RD is the declared thermal resistance m2„K/W Ri is one test result of thermal resistance m2„K/W Rmean is the mean thermal resistance m2„K/W RU is the design thermal resistance m2„K/W Sb is the deviation from squareness of the edge on length and width mm/m Smax is the deviation from flatness mm sR is the estimate of the standard deviation of the thermal resistance m2„K/W S is the estimate of the standard deviation of the thermal conductivity W/(m„K) s is the dynamic stiffness MN/m3 110 is the compressive stress at 10 % deformation kPa 1c is the compressive stress kPa SIST EN 13162:2013+A1:2015

AFr is the symbol of the level airflow resistivity AP is the symbol of the declared level of practical sound absorption coefficient AW is the symbol of the declared level of weighted sound absorption coefficient BS is the symbol of the declared bending strength CC(i1/i2/y) 1c is the symbol of the declared level for compressive creep CP is the symbol of the declared level for compressibility CS(10\Y) is the symbol of the declared level for compressive stress or compressive strength DS(70,-) is the symbol of the declared value for dimensional stability at specified temperature DS(23,90)
or
DS (70,90) is the symbol of the declared value for dimensional stability under specified temperature and relative humidity conditions MU is the symbol of the declared value for water vapour diffusion resistance factor PL(5) is the symbol of the declared level of point load for 5 mm deformation SD is the symbol of the declared level of dynamic stiffness SS is the symbol of the declared value of shear strength T is the symbol of the declared class or level for thickness tolerances TR is the symbol of the declared level for tensile strength perpendicular to faces WL(P) is the symbol of the declared level for long term water absorption by partial immersion WS is the symbol of the declared level for short term water absorption Z is the symbol of the declared value for water vapour resistance Abbreviated terms used in this standard: MW is Mineral Wool !PTD is Product Type Determination (previously named ITT for Initial Type Test)" FPC is Factory Production Control RtF is Reaction to Fire !AVCP is Assessment and Verification of Constancy of Performance (previously named attestation of SIST EN 13162:2013+A1:2015

4.2.3 Thickness Thickness, d, shall be determined in accordance with EN 823. The load shall be 50 Pa except for products with a level of compressive stress or compressive strength of 10 kPa or greater (see 4.3.3), where the load shall be 250 Pa. No test result shall deviate from the nominal thickness, dN, by more than the tolerances given in Table 1 for the declared level or class. Table 1 — Level and classes for thickness tolerances Level or class Tolerances T1 –5 % or –5 mma Excess permitted T2 –5 % or –5 mma +15 % or +15 mmb T3 –3 % or –3 mma +10 % or +10 mmb T4 –3 % or –3 mma +5 % or +5 mmb T5 –1 % or –1 mma +3 mm a Whichever gives the greatest numerical tolerance. b Whichever gives the smallest numerical tolerance. This test shall not be performed when the tests described in 4.3.10 are used. 4.2.4 Squareness Squareness shall be determined in accordance with EN 824. The deviation from squareness on length and width, Sb, of boards and slabs shall not exceed 5 mm/m. SIST EN 13162:2013+A1:2015

shall be greater than the declared value and no test result of Z shall be less than the declared value. In the absence of measurements, the water vapour diffusion resistance factor, , of mineral wool products, either unfaced or faced with a fabric with an open structure, may be assumed to be equal to 1. Alternatively for the declaration of the water vapour diffusion resistance factor, , of MW products, the values quoted in EN ISO 10456 may be used; e.g. MW products either unfaced or faced with a fabric with an open structure, may be assumed to be equal to 1. 4.3.9 Dynamic stiffness Dynamic stiffness, s, shall be determined in accordance with EN 29052-1, without preloading. The value of dynamic stiffness shall be declared in levels with steps of 1 MN/m3. No test result shall exceed the declared level. 4.3.10 Compressibility 4.3.10.1 General The main application of products using compressibility is floating floors. 4.3.10.2 Thickness dL Thickness dL shall be determined in accordance with EN 12431 under a load of 250 Pa. No test result shall deviate from the thickness, dL , by more than the tolerances given in Table 3 for the labelled class. SIST EN 13162:2013+A1:2015

EN 15715:2009 4.3.2 Dimensional stability under specified conditions EN 1604 200 × 200 3 – 4.3.3 Compressive stress or strength EN 826 200 × 200 5 Surface grindingb 300 × 300 3 4.3.4 Tensile strength perpendicular to faces EN 1607 200 × 200 5 – – 300 × 300 3 4.3.5 Point load EN 12430 300 × 300 3 – 4.3.6 Compressive creep EN 1606 200 × 200 300 × 300 5 3 Surface grindingb 4.3.7 Short term water absorption EN 1609 200 × 200 4 Method A Long term water absorption EN 12087 200 × 200 4 Method 1A 4.3.8 Water vapour transmiss
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.

Loading comments...

Die Norm EN 13162:2012+A1:2015 für Wärmeisolierungsprodukte im Bauwesen stellt eine umfassende Grundlage für die Anforderungen an werkseitig hergestellte Mineralwollprodukte dar. Diese Norm ist maßgeblich für die thermische Isolierung von Gebäuden und bietet klare Spezifikationen für Produkte, die sowohl mit als auch ohne Beschichtungen oder Verkleidungen gefertigt werden. Ein zentraler Punkt der Norm ist ihr breiter Anwendungsbereich, der sich nicht nur auf Matten und Platten, sondern auch auf die Verwendung in vorgefertigten Wärmeisolierungssystemen und Verbundplatten erstreckt. Dies verdeutlicht die Relevanz der Norm für verschiedene Bauanwendungen und ihre Eignung in unterschiedlichen Situationen. Die Stärken dieser Norm liegen in der detaillierten Beschreibung der Produkteigenschaften sowie den klaren Verfahren zur Prüfung, Bewertung der Konformität, Kennzeichnung und Etikettierung. Diese Vorgaben sind entscheidend für die Gewährleistung der Qualität und Sicherheit von Mineralwollprodukten, wodurch sie zur Schaffung einer einheitlichen Basis für Hersteller und Verbraucher beitragen. Darüber hinaus ist hervorzuheben, dass die Norm nicht die spezifischen Anforderungen an die Leistungsmerkmale definiert, die für eine bestimmte Anwendung erforderlich sind. Dies bedeutet, dass die Norm flexibel genug ist, um in Übereinstimmung mit nationalen Vorschriften oder anderen relevanten Normen angewendet zu werden. Diese Flexibilität ist besonders vorteilhaft, da sie eine Anpassung an unterschiedliche Marktbedürfnisse und Regulierungen ermöglicht. Es ist wichtig zu beachten, dass Produkte mit einer angegebenen Wärmeleitfähigkeit von mehr als 0,060 W/(m·K) bei 10 °C oder einer erklärten Wärmebeständigkeit von weniger als 0,25 m²·K/W nicht abgedeckt sind. Dies führt zu einer Fokussierung auf Produkte, die höchsten Standards entsprechen, und trägt zur Verbesserung der energieeffizienten Bauweise bei. Insgesamt stellt die EN 13162:2012+A1:2015 eine essenzielle Norm für die Bauindustrie dar, die nicht nur die Qualität und Sicherheit von Mineralwollprodukten gewährleistet, sondern auch deren breite Anwendbarkeit in der modernen Architektur fördert.

The standard EN 13162:2012+A1:2015 provides a comprehensive framework for the specification of factory-made mineral wool (MW) products used for thermal insulation in buildings. Its primary scope includes a broad range of products, such as mats, blankets, boards, and slabs, which are essential for maintaining energy efficiency and thermal comfort in building structures. One of the strengths of this standard is its detailed specification of product characteristics, which is crucial for manufacturers and consumers looking for consistent quality in thermal insulation solutions. The inclusion of testing procedures ensures that products comply with necessary performance benchmarks, thereby enhancing the reliability of mineral wool products in various applications. The standard also presents clear guidelines for evaluating conformity, marking, and labeling, which facilitates transparency and trust in the marketplace. This aspect is particularly significant for regulatory compliance and for stakeholders who require documentation to confirm that products meet established criteria. Another notable strength is its alignment with European regulations, although it explicitly states that specific levels of properties required for fitness for purpose are covered by additional regulations or non-conflicting standards. This clarity allows for a more focused application of the EN 13162 standard without conflicting with other relevant standards, streamlining the process for end-users and producers. However, the standard does have limitations; it does not cover products with a declared thermal resistance lower than 0.25 m²·K/W or thermal conductivity greater than 0.060 W/(m·K), which indicates a boundary for its applicability. Moreover, it excludes in-situ insulation products and those intended for insulating building equipment and industrial installations, directing users to EN 14064 and EN 14303 for those specifications. In summary, EN 13162:2012+A1:2015 stands out for its comprehensive and structured approach to thermal insulation products, ensuring they meet rigorous standards for performance while providing clear guidelines for conformity and labeling. Its relevance in the construction industry, coupled with the demand for energy-efficient materials, reinforces the importance of this standard in fostering sustainable building practices.

この標準に関する詳細なレビューでは、EN 13162:2012+A1:2015の範囲、強み、関連性に焦点を当てることが重要です。 EN 13162:2012+A1:2015は、建物のための製造された鉱物ウール(MW)製品に関する欧州標準です。この標準は、工場製造された鉱物ウール製品の要求事項を明確に定義しており、これにより建物の熱絶縁材として使用される製品の品質が保証されます。具体的には、マット、ブランケット、ボード、スラブなどの形態で製造される製品について規定されています。 この標準の強みは、製品特性の明確な説明と、試験手順、適合性評価、マーク付けおよびラベリングの手続きが組み込まれている点です。これにより、製造者は製品が標準に適合しているかどうかを確認するための基準を持ち、消費者に対して信頼性を提供できます。 さらに、EN 13162は、プレハブ熱絶縁システムや複合パネルで使用される製品についても言及しています。しかし、この標準は、特定の用途に対する製品の適合性を示すために必要な特性のレベルを規定していないため、具体的なアプリケーションに関しては関連法規や矛盾しない他の標準を参照する必要があります。 規定された熱抵抗が0.25 m²·K/W未満または熱伝導率が10 °Cで0.060 W/(m·K)を超える製品は、この標準の対象外とされています。これにより、特定の性能基準を満たさない製品が含まれず、品質の維持が図られています。 最後に、この標準は、現場での絶縁製品や建築機器、工業施設用の絶縁のために設計された製品はカバーしていません。このような明確な定義により、EN 13162は建物の熱絶縁に関する標準として非常に関連性が高く、業界における信頼されるガイドラインを提供しています。

SIST EN 13162:2013+A1:2015 표준은 건물의 열 절연에 사용되는 공장 제조 광물성 면화(MW) 제품의 요구 사항을 명시하고 있습니다. 이 표준의 범위는 매트 담요, 보드 또는 슬랩 형태의 제품에 적용되며, 이들 제품은 열 절연 시스템 및 복합 패널에도 사용됩니다. 이 표준의 가장 큰 장점 중 하나는 제품의 특성을 상세히 설명하고, 테스트 및 적합성 평가, 마킹, 라벨링 절차 등을 포함한다는 점입니다. 이러한 절차들은 제조업체가 제품의 품질을 보장하고, 소비자가 신뢰할 수 있는 제품을 선택하는 데 도움을 줍니다. 또한 이 표준은 시장에서의 응용에 따라 요구되는 특정 성능 수준이 규정이나 비충돌 표준에서 찾을 수 있음을 명확히 하고 있습니다. 이는 소비자가 필요한 성능을 가진 제품을 선택할 수 있도록 하여, 보다 효율적인 건축과 에너지 절약을 지원합니다. 그러나 이 표준은 열 저항이 0.25 m2·K/W 미만이거나 열 전도율이 0.060 W/(m·K) 이상인 제품은 적용되지 않으며, 현장 절연 제품이나 산업 장비 및 설치를 위한 절연 제품은 다루지 않기 때문에, 사용자의 필요에 따라 다른 표준을 참고해야 할 필요성이 있습니다. 결론적으로, EN 13162:2012+A1:2015는 공장 제조 광물성 면화 제품의 규격을 명확히 하여 건축의 열 절연 성능을 향상시키고, 사용자와 제조업체 간의 신뢰를 구축하는 데 중요한 역할을 합니다.

La norme EN 13162:2012+A1:2015, intitulée "Produits d'isolation thermique pour les bâtiments - Produits en laine minérale fabriqués en usine - Spécifications", offre un cadre exhaustif pour les produits en laine minérale destinés à l'isolation thermique des bâtiments. Cette norme européenne définit clairement les exigences et les caractéristiques des produits fabriqués en matelas, en panneaux ou en plaques, assurant ainsi une compréhension et une application cohérentes dans le secteur de la construction. L'un des points forts de cette norme est son approche systématique qui inclut des procédures de test rigoureuses, d'évaluation de conformité, et de marquage et étiquetage. Cela garantit que les produits respectent des critères de performance fiables, promouvant ainsi la qualité et la sécurité des matériaux utilisés dans la construction. De plus, la norme offre une flexibilité en ne spécifiant pas de niveaux de performance standardisés pour chaque propriété, laissant ainsi place aux réglementations spécifiques ou aux normes non conflictuelles dans des applications particulières. Il est également essentiel de noter que la norme couvre les produits sans ou avec revêtements, élargissant ainsi sa portée d'application pour différents types de systèmes de construction, y compris les systèmes d'isolation thermique préfabriqués. Cependant, elle informe clairement que les produits avec une résistance thermique déclarée inférieure à 0,25 m²·K/W ou une conductivité thermique déclarée supérieure à 0,060 W/(m·K) à 10 °C ne sont pas inclus, ce qui préserve la qualité et l'efficacité des matériaux décrits. Enfin, il est important de souligner que la norme ne s'applique pas aux produits d'isolation en place ni à ceux destinés à l'isolation des équipements de construction et installations industrielles, ce qui clarifie son champ d'application et renforce sa pertinence pour les acteurs du marché de l'isolation thermique des bâtiments. En résumé, la norme EN 13162:2012+A1:2015 représente une ressource précieuse pour les professionnels du bâtiment cherchant à garantir une isolation thermique adéquate à travers des produits de laine minérale, en assurant conformité, qualité et clarté dans les processus de fabrication et d'application des matériaux isolants.