Safety rules for the construction and installation of lifts - Examination and tests - Part 58: Landing doors fire resistance test

This European Standard specifies the method of test for determining the fire resistance of lift landing doors which may be exposed to a fire from the landing side. The procedure applies to all types of lift landing doors used as a means of access to lifts in buildings and which are intended to provide a fire barrier to the spread of fire via the lift well. The procedure allows for the measurement of integrity and if required the measurement of radiation and thermal insulation. No requirements are included for mechanical conditioning as these are included in the relevant product standard.

Sicherheitsregeln für die Konstruktion und den Einbau von Aufzügen - Überprüfung und Prüfverfahren - Teil 58: Prüfung der Feuerwiderstandsfähigkeit von Fahrschachttüren

Diese Europäische Norm legt ein Prüfverfahren für die Bestimmung der Feuerwiderstandsfähigkeit von Fahrschachttüren fest, die einem Brand auf der Flurseite ausgesetzt sein können. Das Verfahren gilt für sämtliche Arten von Fahrschachttüren, die für den Zugang zu Aufzügen in Gebäuden eingesetzt werden und die Aufgabe haben, die Ausbreitung von Feuer über den Fahrschacht zu verhindern.
Das Prüfverfahren ermöglicht die Messung des Raumabschlusses und, falls erforderlich, die Messung von Strahlung und Wärmedämmung.
Anforderungen hinsichtlich der mechanischen Vorbehandlung vor der Brandprüfung, außer der Überprüfung, dass der Probekörper funktionsfähig ist, sind nicht Gegenstand dieser Norm, da diese in den entsprechenden Produktnormen enthalten sind.

Règles de sécurité pour la construction et l'installation des élévateurs - Examen et essais - Partie 58: Essais de résistance au feu des portes palières

Cette norme européenne spécifie la méthode d'essai pour déterminer la résistance au feu des portes palières d'ascenseur qui peuvent être exposées à un feu du côté palier. Le mode opératoire s'applique à tous les types de portes palières d'ascenseur utilisées comme moyen d'accès aux ascenseurs dans des bâtiments et destinées à constituer une barrière contre l'extension d'un feu par la gaine d'ascenseur.
Le mode opératoire permet de mesurer l'étanchéité et si nécessaire, le rayonnement et l'isolation thermique.
Aucune prescription, autre que la vérification du fonctionnement du spécimen, ne concerne le conditionnement mécanique, car ce domaine relève de la norme appropriée concernant le produit.

Varnostna pravila za konstruiranje in vgradnjo dvigal (liftov) - Pregled in preskusi - 58. del: Preskus odpornosti vrat proti požaru

General Information

Status
Withdrawn
Publication Date
22-Jul-2003
Withdrawal Date
13-Mar-2018
Current Stage
9960 - Withdrawal effective - Withdrawal
Completion Date
14-Mar-2018

Relations

Buy Standard

Standard
EN 81-58:2004
English language
29 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-april-2004
Varnostna pravila za konstruiranje in vgradnjo dvigal (liftov) - Pregled in preskusi -
58. del: Preskus odpornosti vrat proti požaru
Safety rules for the construction and installation of lifts - Examination and tests - Part 58:
Landing doors fire resistance test
Sicherheitsregeln für die Konstruktion und den Einbau von Aufzügen - Überprüfung und
Prüfverfahren - Teil 58: Prüfung der Feuerwiderstandsfähigkeit von Fahrschachttüren
Regles de sécurité pour la construction et l'installation des élévateurs - Examen et essais
- Partie 58: Essais de résistance au feu des portes palieres
Ta slovenski standard je istoveten z: EN 81-58:2003
ICS:
13.220.50 Požarna odpornost Fire-resistance of building
gradbenih materialov in materials and elements
elementov
91.140.90 'YLJDOD7HNRþHVWRSQLFH Lifts. Escalators
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD
EN 81-58
NORME EUROPÉENNE
EUROPÄISCHE NORM
July 2003
ICS 91.140.90
English version
Safety rules for the construction and installation of lifts -
Examination and tests - Part 58: Landing doors fire resistance
test
Règles de sécurité pour la construction et l'installation des Sicherheitsregeln für die Konstruktion und den Einbau von
élévateurs - Examen et essais - Partie 58: Essais de Aufzügen - Überprüfung und Prüfverfahren - Teil 58:
résistance au feu des portes palières Prüfung der Feuerwiderstandsfähigkeit von
Fahrschachttüren
This European Standard was approved by CEN on 18 March 2003.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national
standards may be obtained on application to the Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CEN member into its own language and notified to the Management Centre has the same status as the official
versions.
CEN members are the national standards bodies of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece,
Hungary, Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands, Norway, Portugal, Slovakia, Spain, Sweden, Switzerland and United
Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre: rue de Stassart, 36  B-1050 Brussels
© 2003 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 81-58:2003 E
worldwide for CEN national Members.

Contents
Foreword.4
Introduction .5
1 Scope .6
2 Normative references .6
3 Terms and definitions.6
4 Test principle.7
5 Test equipment .7
6 Test conditions .7
7 Test specimen .8
7.1 Construction.8
7.2 Number of specimens .8
7.3 Size of specimen.8
7.4 Installation of specimen .8
8 Supporting construction .8
9 Conditioning.8
10 Pre-test examination.8
10.1 General.8
10.2 Constructional details .9
10.3 Clearance gap measurements and depth of penetration .9
10.4 Functionality test .13
11 Test instrumentation .14
11.1 Furnace thermocouples .14
11.2 Furnace CO concentration.14
11.3 Gas flow measuring system instrumentation.14
11.4 Furnace pressure.14
11.5 Unexposed face temperature.14
11.6 Radiation measurement .15
11.7 Deformation measurement .15
11.8 Flow measurement verification .16
12 Test procedure .16
13 Test termination .16
14 Assessment of performance.16
15 Criteria of performance .17
15.1 Integrity (E) .17
15.2 Thermal insulation (I).17
15.3 Radiation (W).17
16 Direct field of application.17
17 Classification procedure and declaration of performance.18
17.1 Performance criteria .18
17.2 Classification periods.18
17.3 Designatory letters .18
17.4 Declaration of performance .18
17.5 Classes.18
18 Test report .19
Annex A (normative) Description of the canopy and measuring system.20
Annex B (normative) Standard supporting construction.23
Annex C (normative) Verification procedure for leakage rate measurement .24
Annex D (normative) Calculation of leakage rate .25
D.1 Calculation of leakage rate when measuring according to EN ISO 5167-1 with an orifice plate.25
D.2 Pressure correction:.26
D.3 Interpreting the leakage rate curve.27
Annex ZA (informative) Relationship of this European Document with EC Directives .28
Bibliography .29
Foreword
This document EN 81-58:2003 has been prepared by Technical Committee CEN/TC 10 “Lifts, escalators and
moving walks”, the secretariat of which is held by AFNOR.
This European Standard shall be given the status of a national standard, either by publication of an identical text or
by endorsement, at the latest by January 2004, and conflicting national standards shall be withdrawn at the latest
by January 2004.
This document has been prepared under a mandate given to CEN by the European Commission and the European
Free Trade Association, and supports essential requirements of EU Directive(s).
For relationship with EU Directive(s), see informative Annex ZA, which is an integral part of this document.
Annexes A to D are normative.
According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following
countries are bound to implement this European Standard: Austria, Belgium, Czech Republic, Denmark, Finland,
France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands, Norway, Portugal,
Slovakia, Spain, Sweden, Switzerland and the United Kingdom.
Introduction
This document is a type C standard as stated in EN 1070.
When provisions of this type C standard are different from those which are stated in type A or B standards, the
provisions of this type C standard take precedence over the provisions of the other standards for lift landing doors
that have been designed and built according to the provisions of this type C standard.
EN 81 has identified the need for certain lift doors to act as fire barriers against the transfer of a fire via the lift well.
This European Standard specifies a procedure for this purpose. It follows the general principle of EN 1363-1, Fire
resistance tests – Part 1: General requirements, and where appropriate the procedure of EN 1634-1, Fire
resistance tests for door and shutter assemblies – Part 1: Fire doors and shutters. Additionally a tracer gas
technique for establishing the integrity of a lift landing door is used.
Lift landing doors are not included in the scope of EN 1634-1.
Lift landing doors, with additional applications, that may already have been tested for other than passenger lift
landing door use to EN 1634-1, are considered to satisfy the corresponding classification according to this
European standard.
1 Scope
This European Standard specifies the method of test for determining the fire resistance of lift landing doors which
may be exposed to a fire from the landing side. The procedure applies to all types of lift landing doors used as a
means of access to lifts in buildings and which are intended to provide a fire barrier to the spread of fire via the lift
well.
The procedure allows for the measurement of integrity and if required the measurement of radiation and thermal
insulation.
No requirements other than the verification that the specimen is operational, are included for mechanical
conditioning before the test as these are included in the relevant product standard.
2 Normative references
This European Standard incorporates by dated or undated reference, provisions from other publications. These
normative references are cited at the appropriate places in the text and the publications are listed hereafter. For
dated references, subsequent amendments to or revisions of any of these publications apply to this European
Standard only when incorporated in it by amendment or revision. For
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.