Eurocode 1: Actions on structures - Part 1-4: General actions - Wind actions

TC - Modifications in the E mother reference version in "National annex for EN 1991-1-4", in Sections 1, 2, 6, 7 and 8, in Annexes A, C, D, E and F, and in the Bibliography.

Eurocode 1: Einwirkungen auf Tragwerke - Teil 1-4: Allgemeine Einwirkungen - Windlasten

Eurocode 1 : Actions sur les structures - Partie 1-4 : Actions générales - Actions du vent

Evrokod 1: Vplivi na konstrukcije - 1-4. del: Splošni vplivi - Obtežbe vetra

General Information

Status
Withdrawn
Publication Date
28-Jul-2009
Withdrawal Date
26-Jan-2010
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
27-Jan-2010
Completion Date
27-Jan-2010

Relations

Buy Standard

Corrigendum
EN 1991-1-4:2005/AC:2009
English language
11 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Evrokod 1: Vplivi na konstrukcije - 1-4. del: Splošni vplivi - Obtežbe vetraEurocode 1: Einwirkungen auf Tragwerke - Teil 1-4: Allgemeine Einwirkungen - WindlastenEurocode 1 : Actions sur les structures - Partie 1-4 : Actions générales - Actions du ventEurocode 1: Actions on structures - Part 1-4: General actions - Wind actions91.010.30Technical aspectsICS:Ta slovenski standard je istoveten z:EN 1991-1-4:2005/AC:2009SIST EN 1991-1-4:2005/AC:2009en01-november-2009SIST EN 1991-1-4:2005/AC:2009SLOVENSKI
STANDARD
EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 1991-1-4:2005/AC
July 2009
Juillet 2009
Juli 2009 ICS 91.010.30 English version Version Française Deutsche Fassung
Eurocode 1: Actions on structures - Part 1-4: General actions - Wind actions
Eurocode 1 : Actions sur les structures - Partie 1-4 : Actions générales - Actions du vent
Eurocode 1: Einwirkungen auf Tragwerke -Teil 1-4: Allgemeine Einwirkungen - Windlasten This corrigendum becomes effective on 29 July 2009 for incorporation in the three official language versions of the EN.
Ce corrigendum prendra effet le 29 juillet 2009 pour incorporation dans les trois versions linguistiques officielles de la EN.
Die Berichtigung tritt am 29.Juli 2009 zur Einarbeitung in die drei offiziellen Sprachfassungen der EN in Kraft.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre:
Avenue Marnix 17,
B-1000 Brussels © 2009 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Tous droits d'exploitation sous quelque forme et de quelque manière que ce soit réservés dans le monde entier aux membres nationaux du CEN. Alle Rechte der Verwertung, gleich in welcher Form und in welchem Verfahren, sind weltweit den nationalen Mitgliedern von CEN vorbehalten. Ref. No.:EN 1991-1-4:2005/AC:2009 D/E/FSIST EN 1991-1-4:2005/AC:2009

“(11) This part does not give guidance on the following aspects: − wind actions on lattice towers with non-parallel chords − wind actions on guyed masts and guyed chimneys − torsional vibrations, e.g. tall buildings with a central core − bridge deck vibrations from transverse wind turbulence
− cable supported bridges − vibrations where more than the fundamental mode needs to be considered NOTE 1 The National Annex may provide guidance on these aspects as non contradictory complementary information. NOTE 2 For wind actions on guyed masts, guyed chimneys and lattice towers with non-parallel chords, see EN 1993-3-1, Annex A.
NOTE 3 For wind actions on lighting columns, see EN 40.” with: “(11) Guyed masts and lattice towers are treated in EN 1993-3-1 and lighting columns in EN 40. SIST EN 1991-1-4:2005/AC:2009

• wind actions on cable supported bridges • vibrations where more than the fundamental mode needs to be considered.”. 3) Modifications to 1.7 Pages 11 and 12, paragraph “(2)”, “Latin upper case letters”, between the lines dedicated to “K” and “Kiv”, add the following line: “Ka aerodynamic damping parameter”. Page 12, paragraph “(2)”, “Latin lower case letters”, between the lines dedicated to “cp” and “cprob”, add the following lines: “cpe external pressure coefficient
cpi
internal pressure coefficient cp,net net pressure coefficient”. Page 13, paragraph “(2)”, “Latin lower case letters”, between the lines dedicated to “k” and “kp”, add the following lines: “kl turbulence factor”. Page 14, paragraph “(2)”, “Greek lower case letters”, definition of “δa”, replace “aerodynamic logarithmic decrement of damping” with “logarithmic decrement of aerodynamic damping”. Page 14, paragraph “(2)”, “Greek lower case letters”, definition of “δs”, replace “structural logarithmic decrement of damping” with “logarithmic decrement of structural damping”. 4) Modification to “Section 2” Page 16, paragraph “(2)”, replace the “NOTE”: “NOTE See also EN 1991-1-3, EN 1991-2 and ISO FDIS12494” with the following: “NOTE
See also EN 1991-1-3, EN 1991-2 and ISO 12494”. 5) Modification to 6.3.2 Page 30, paragraph “(1)”, 3rd line, replace “5.2” with “5.3”. SIST EN 1991-1-4:2005/AC:2009

• for 0,2 ≤ f/d ≤ 0,3 and h/d ≥ 0,5, two values of cpe,10 have to be considered
• the diagram is not applicable for flat roofs”. 7) Modification to 7.3 Page 56, paragraph “(8)”, “Table 7.6”, 5th row “[Roof angle . = ]10°”, 4th column “Zone A”, 3rd line in the cell (corresponding to “Minimum 3 = 1”), replace “- 2,1” with “- 1,6”. 8) Modifications to 7.8 Page 68, paragraph “(1)”, “Table 7.11”, replace the table with the following one: SIST EN 1991-1-4:2005/AC:2009

Re ≤ 2,4⋅105 1,45 Re ≥ 3⋅105 1,30 surface smooth (b) r/b ≥ 0,075
Re ≤ 2⋅105 1,30 Re ≥ 7⋅105 1,10 10 Decagon all All 1,30 12 Dodecagon surface smooth (c)corners rounded 2 ⋅ 105 < Re < 1,2⋅106 0,90 all others Re < 4⋅105 1,30 Re >
4⋅105 1,10 16-18 Hexdecagon to Octadecagon
surface smooth (c)corners rounded Re < 2⋅105 treat as a circular cylinder, see (7.9) 2⋅105 ≤ Re < 1,2⋅106 0,70 (a) Reynolds number with v = vm and vm given in 4.3, Re, is defined in 7.9 (b) r = corner radius, b = diameter of circumscribed circumference, see Figure 7.26 (c)
From wind tunnel tests on sectional models with galvanised steel surface and a section with b = 0,3 m and corner radius of 0,06 ⋅b “. Page 68, paragraph “(2)”, replace the paragraph with the following text: “(2) For buildings where h/d > 5, cf may be determined from Expression (7.13). NOTE
See also Table 7.11 and Figure 7.26.”. 9) Modifications to 7.11 Page 76, paragraph “(1)”, “NOTE 1”, replace “Figure 7.33 to 7.35 are based” with “Figure 7.35 is based”. Page 76, paragraph “(1)”,replace “NOTE 2”: “NOTE 2 The National Annex may give a reduction factor for scaffolding without air tightness devices and affected by solid building obstruction. A recommended value is given in prEN 12811.” with: “NOTE 2 The National Annex may give a reduction factor for scaffolding without air tightness devices and affected by solid building obstruction. A recommended value is given in EN 12811.”. SIST EN 1991-1-4:2005/AC:2009

is the air density (see 7.1)” with: “
is the air density (see 4.5 (1) NOTE 2)”. 11) Modification to 8.1 Page 84, paragraph “(3)”, replace the ”NOTE”: “NOTE The notation used for bridges differs from that defined in 1.7. The following notations are used for bridges: L
length in y-direction b width in x-direction d
depth in z-direction In Figure 8.2 the values to be given to L ,b and d in various cases are, where relevant, more precisely defined in further clauses. When Sections 5 to 7 are referred to, the notations for b and d ne
...

Questions, Comments and Discussion