EN 15502-2-1:2012/FprA1
(Amendment)Gas-fired central heating boilers - Part 2-1: Specific standard for type C appliances and type B2, B3 and B5 appliances of a nominal heat input not exceeding 1 000 kW
Gas-fired central heating boilers - Part 2-1: Specific standard for type C appliances and type B2, B3 and B5 appliances of a nominal heat input not exceeding 1 000 kW
When final draft in CCMC - Double check that a decision (to submit to FV) is taken both by CEN/TC 166 and CEN/TC 109 - See CEN/BT Decision 72/2014
Heizkessel für gasförmige Brennstoffe - Teil 2-1: Heizkessel der Bauart C und Heizkessel der Bauarten B2, B3 und B5 mit einer Nennwärmebelastung nicht größer als 1 000 kW
Chaudières de chauffage central utilisant les combustibles gazeux - Partie 2-1 : Norme spécifique pour les appareils de type C et les appareils de types B2, B3 et B5 dont le débit calorifique nominal est inférieur ou égal à 1 000 kW
Plinski kotli za centralno gretje - 2-1. del: Poseben standard za tip kotlov C in tipe kotlov B2, B3 in B5 z imensko močjo do vključno 1000 kW - Dopolnilo A1
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
SIST EN 15502-2-1:2013/oprA1:2014
01-marec-2014
3OLQVNLNRWOL]DFHQWUDOQRJUHWMHGHO3RVHEHQVWDQGDUG]DWLSNRWORY&LQWLSH
NRWORY%%LQ%]LPHQVNRPRþMRGRYNOMXþQRN:'RSROQLOR$
Gas-fired central heating boilers - Part 2-1: Specific standard for type C appliances and
type B2, B3 and B5 appliances of a nominal heat input not exceeding 1 000 kW
Heizkessel für gasförmige Brennstoffe - Teil 2-1: Heizkessel der Bauart C und
Heizkessel der Bauarten B2,B3 und B5 mit einer Nennwärmebelastung nicht größer als
1 000 kW
Chaudières de chauffage utilisant les combustibles gazeux - Partie 2-1: Norme
spécifique pour les appareils de type C et les appareils de types B2, B3 et B5 dont le
débit calorifique nominal est inférieur ou égal à 1 000 kW
Ta slovenski standard je istoveten z: EN 15502-2-1:2012/prA1
ICS:
91.140.10 Sistemi centralnega Central heating systems
ogrevanja
97.100.20 Plinski grelniki Gas heaters
SIST EN 15502-2-1:2013/oprA1:2014 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
SIST EN 15502-2-1:2013/oprA1:2014
SIST EN 15502-2-1:2013/oprA1:2014
EUROPEAN STANDARD
DRAFT
EN 15502-2-1:2012
NORME EUROPÉENNE
EUROPÄISCHE NORM
prA1
February 2014
ICS 91.140.10; 27.060.30
English Version
Gas-fired central heating boilers - Part 2-1: Specific standard for
type C appliances and type B2, B3 and B5 appliances of a
nominal heat input not exceeding 1 000 kW
Combustibles de chauffage utilisant les combustibles Heizkessel für gasförmige Brennstoffe - Teil 2-1: Heizkessel
gazeux - Partie 2-1 : Norme spécifique pour les appareils der Bauart C und Heizkessel der Bauarten B2, B3 und B5
de type C et les appareils de types B2, B3 et B5 dont le mit einer Nennwärmebelastung nicht größer als 1 000 kW
débit calorifique nominal est inférieur ou égal à 1 000 kW
This draft amendment is submitted to CEN members for enquiry. It has been drawn up by the Technical Committee CEN/TC 109.
This draft amendment A1, if approved, will modify the European Standard EN 15502-2-1:2012. If this draft becomes an amendment, CEN
members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for inclusion of this amendment
into the relevant national standard without any alteration.
This draft amendment was established by CEN in three official versions (English, French, German). A version in any other language made
by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has
the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania,
Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United
Kingdom.
Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are aware and to
provide supporting documentation.
Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without notice and
shall not be referred to as a European Standard.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2014 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 15502-2-1:2012/prA1:2014 E
worldwide for CEN national Members.
SIST EN 15502-2-1:2013/oprA1:2014
EN 15502-2-1:2012/prA1:2014 (E)
Contents
Page
Foreword .4
1 Modifications to the Foreword .4
2 Modifications to the Introduction .5
3 Modifications to '1 Scope' .5
4 Modifications to '3 Terms, definitions and symbols' .6
5 Modifications to '5 Construction' .8
6 Modifications to '8 Operational requirements'.9
6.1 Modifications to '8.1 General' .9
6.1.1 Modifications to '8.1.2.1 Installation of the boilers' .9
6.1.2 Modifications to Additions to '8.1.2 General test conditions' After clause 8.1.2.8 of EN
15502-2-1:2012, .9
6.2 Modifications to '8.2 Soundness' . 11
6.3 Modifications to '8.4 Heat inputs and heat output' . 11
6.4 Modifications to '8.6 Ignition, cross lighting, flame stability'. 12
6.4.1 Modifications to '8.6.2 Limit conditions" . 12
6.4.2 Modifications to '8.6.3 Special conditions " . 12
6.5 Modifications to '8.9 Pre-purge . 14
6.5.1 Modifications to '8.9.101 General' . 14
6.6 Modifications to 8.11.101 Air proving device . 15
6.6.1 Modifications to 8.11.101.3.3 Adjustment of the gas/air ratio . 15
6.7 Modifications to '8.12 Carbon monoxide' . 15
6.7.1 Modifications to '8.12.2.102 Boilers using Gas/air Ratio Controls" . 15
6.7.2 Modifications to '8.12.3 Special conditions'. 16
6.8 Addition of a new clause '8.104 Additional requirements for non-return valve for type C
(10)
and C boilers' . 17
(11)
"8.104 Additional requirements for non –return valve for type C and C boilers . 17
(10) (11)
8.104.1 General . 17
8.104.2 Nominal working temperature at the position of the non-return valve . 17
8.104.3 Leak tightness of the non-return valve. 17
8.104.4 Functional durability of the non-return valve . 18
8.104.5 Short term safety of boiler in case of a failing non-return valve . 18
8.104.6 Long term safety of the boiler in case of a failing non-return valve . 20
6.9 Addition of a new clause '8.105 Additional requirements for the evaluation of the
transport capacity of the commonshared duct system for type C(11) boilers ' . 20
"8.105 Additional requirements for the evaluation of the transport capacity of the common duct
system for type C boilers . 20
(11)
8.105.1 Requirements of common duct system without wind conditions . 20
8.105.2 Additional requirements of common duct system due to wind influence . 20
6.10 Modifications to '12.2.1.4 For installation of the combustion circuit' . 21
6.10.1 Addition of a new clause '12.2.1.4.111 For room sealed appliances of the type C boiler' . 21
(10)
6.10.2 Addition of a new clause '12.2.1.4.112 For room sealed appliances of the type C boiler' . 23
(11)
7 Modifications to '103 . Annexes' 24
8 Addition of a new 'Annex EE (informative) Example on calculation of common duct
system for type C appliances . 24
(11)
"Annex EE (informative) Example on calculation of common duct system for type C appliances . 25
(11)
9 Note to Annexes Z . 27
SIST EN 15502-2-1:2013/oprA1:2014
EN 15502-2-1:2012/prA1:2014 (E)
10 Modifications to Bibliography . 27
SIST EN 15502-2-1:2013/oprA1:2014
EN 15502-2-1:2012/prA1:2014 (E)
Foreword
This document (EN 15502-2-1:2012/prA1:2014) has been prepared by Technical Committee CEN/TC 109
“Central heating boilers using gaseous fuels”, the secretariat of which is held by NEN.
This document is currently submitted to the CEN Enquiry.
This document has been prepared under a mandate given to CEN by the European Commission and the
European Free Trade Association, and supports essential requirements of EU Directive.
1 Modifications to the Foreword
The flowing text is added in the foreword of EN 15502-2-1:2012 after the changes mentioned in EN 15502-2-
1:
1)
The requirements for type C and C boilers are now added to this draft standard.
(10) (11)
Explanatory Text:
Normally type C4 and type C8 boilers connected to common duct systems are functioning designed to
function with natural draught in the common flue duct system. If a common duct system, is applied at positive
pressure , new examination aspects are requested. For example: Boilers which are suitable for application in
such a duct system shall contain devices (valves) which prevents back flow of the combustion products of the
other boilers.
The boiler shall maintain its functionality and general safety level at positive and negative pressure.
If a system is a complete combined system including boilers, valves and the applied common duct system,
this system is examined according to the Gas Appliance Directive.
In the case C the appliances are evaluated on its own. The applied common duct system is designed by
(10)
another party, for example an installer, who takes the responsibility of the functioning of the complete system.
Starting points during the development of these requirements are:
— The approved technical content of the AHG-CO was drafted in a version of prEN 155502-2-1 dating from
October 2009. In this draft this technical content is added in the publication of EN 15502-2-1:2012.
— The definitions used for, C and type C boilers are the definition as drawn up by
(10) (11)
SFG-U/WG 1 for the use in the next version of CEN/TR 1749 (part of the these definitions are still draft
definitions).
— A non-return valve must prevent the back flow of combustion gas through boilers which are not running.
The non-return valve must be tested (Clause 5.102 and 8.104).
— When a tested open/close valve is used the boiler must be tested for resistance to condensate (safe
operation on short and long term). (Clause 8.104).
SIST EN 15502-2-1:2013/oprA1:2014
EN 15502-2-1:2012/prA1:2014 (E)
— One of the most critical situations is the influence of the positive pressure on the good working of the gas-
air-ratio control/gasvalve at minimum heat input. In this case the gas-air-ratio control/gasvalve can be out
of its working range. As a result of this a significant amount of CO can be produced. This item is dealt with
in Clause 8.12.2.102 and 8.12.3.101.8 and 8.12.101.9."
2 Modifications to the Introduction
The last 2 paragraphs of the introduction of EN 15502-2-1:2012:
"After the DOW (3 years after publication of both EN 15502-1 and EN 15502-2-1 in the OJEU) the standards
specified in Annex AA, for the appliance types covered in EN 15502-2-1, are withdrawn.
Annex AA lists those existing appliance types for which CEN/TC109 standards are intended to be replaced by
EN 15502-2-2. The standards listed in Annex AA are to be used until EN 15502-2-2 specifies that the
standards are withdrawn for the appliance types indicated. "
Are replaced by the following text:
After the DOW (3 years after the DAV of both EN 15502-1 and EN 15502-2-1) the standards specified in
Annex AA, for the appliance types covered in EN 15502-2-1, are withdrawn.
Annex AA also lists those existing appliance types for which CEN/TC109 standards are intended to be
replaced by EN 15502-2-2. The standards (that are intended to be replaced by EN 15502-2-2) listed in Annex
AA are to be used until EN 15502-2-2 specifies that the standards are withdrawn for the appliance types
indicated.
3 Modifications to '1 Scope'
rd
The following text is added after the 3 paragraph of the scope of EN 15502-2-1:2012:
"In this draft new text is added for the new types C and C , is included. In all 2 cases the definitions for
(10) (11)
these types are still draft definitions in the draft TR 1749 (date: Feburary 2013)."
The text under p) of the scope of EN 15502-
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.