Leather - Determination of water resistance of flexible leather - Part 2: Repeated angular compression (Maeser) (ISO 5403-2:2011)

ISO 5403-2:2011 specifies a method for determining the dynamic water resistance of leather by means of repeated angular compression. It is applicable to all flexible leathers but is particularly suitable for leathers intended for footwear applications. It uses a Maeser-type machine and includes an option for electronic detection.

Leder - Bestimmung der Wasserbeständigkeit von flexiblem Leder - Teil 2: Winkelbiegeverfahren (Maeser) (ISO 5403-2:2011)

Dieses Dokument legt ein Verfahren zur Bestimmung der dynamischen Wasserbeständigkeit durch das
Winkelbiegeverfahren fest. Es gilt für alle flexiblen Leder, von besonderem Interesse ist es jedoch für
Oberleder von Schuhwerk. In dem Verfahren kommt ein Maeser-Apparat zum Einsatz und eine Möglichkeit
zum elektronischen Nachweis ist eingeschlossen.

Cuir - Détermination de l'imperméabilité à l'eau des cuirs souples - Partie 2: Compression angulaire répétée (Maeser) (ISO 5403-2:2011)

L'ISO 5403-2:2011 spécifie une méthode pour déterminer l'imperméabilité dynamique du cuir à l'eau par compression angulaire répétée. Elle s'applique à tous les cuirs souples, mais elle convient particulièrement aux cuirs destinés à l'industrie de la chaussure. Elle utilise un appareil de type Maeser et inclut une option pour la détection électronique.

Usnje - Ugotavljanje odpornosti upogljivega usnja proti vodi - 2. del: Ponavljajoča se kotna kompresija (Maeser) (ISO 5403-2:2011)

Ta del standarda ISO 5403 določa metodo za ugotavljanje dinamične odpornosti usnja proti vodi s ponavljajočo se kotno kompresijo. Uporablja se za vse vrste upogljivega usnja, vendar je še posebno primerna za vrste usnja, namenjene za obutev. Metoda vključuje uporabo stroja tipa Maeser in možnost elektronskega zaznavanja.

General Information

Status
Published
Publication Date
14-Dec-2011
Withdrawal Date
29-Jun-2012
Current Stage
6060 - Definitive text made available (DAV) - Publishing
Start Date
15-Dec-2011
Due Date
27-Dec-2011
Completion Date
15-Dec-2011

Buy Standard

Standard
EN ISO 5403-2:2012
English language
12 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-marec-2012
8VQMH8JRWDYOMDQMHRGSRUQRVWLXSRJOMLYHJDXVQMDSURWLYRGLGHO3RQDYOMDMRþD
VHNRWQDNRPSUHVLMD 0DHVHU  ,62
Leather - Determination of water resistance of flexible leather - Part 2: Repeated angular
compression (Maeser) (ISO 5403-2:2011)
Leder - Bestimmung der Wasserbeständigkeit von flexiblem Leder - Teil 2:
Winkelbiegeverfahren (ISO 5403-2:2011)
Cuir - Détermination de l'imperméabilité à l'eau des cuirs souples - Partie 2:
Compression angulaire répétée (Maeser) (ISO 5403-2:2011)
Ta slovenski standard je istoveten z: EN ISO 5403-2:2011
ICS:
59.140.30 Usnje in krzno Leather and furs
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD
EN ISO 5403-2
NORME EUROPÉENNE
EUROPÄISCHE NORM
December 2011
ICS 59.140.30; 61.060
English Version
Leather - Determination of water resistance of flexible leather -
Part 2: Repeated angular compression (Maeser) (ISO 5403-
2:2011)
Cuir - Détermination de l'imperméabilité à l'eau des cuirs Leder - Bestimmung der Wasserbeständigkeit von
souples - Partie 2: Compression angulaire répétée flexiblem Leder - Teil 2: Winkelbiegeverfahren (ISO 5403-
(Maeser) (ISO 5403-2:2011) 2:2011)
This European Standard was approved by CEN on 14 December 2011.

CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national
standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member.

This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same
status as the official versions.

CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland,
Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland  and United Kingdom.

EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION

EUROPÄISCHES KOMITEE FÜR NORMUNG

Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2011 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN ISO 5403-2:2011: E
worldwide for CEN national Members.

Contents Page
Foreword .3
Foreword
This document (EN ISO 5403-2:2011) has been prepared by Technical Committee CEN/TC 289 “Leather”, the
secretariat of which is held by UNI, in collaboration with the International Union of Leather Technologists and
Chemists Societies.
This European Standard shall be given the status of a national standard, either by publication of an identical
text or by endorsement, at the latest by June 2012, and conflicting national standards shall be withdrawn at
the latest by June 2012.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights.
According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following
countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech
Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain,
Sweden, Switzerland and the United Kingdom
INTERNATIONAL ISO
STANDARD 5403-2
IULTCS/IUP
10-2
First edition
2011-12-15
Leather — Determination of water
resistance of flexible leather —
Part 2:
Repeated angular compression (Maeser)
Cuir — Détermination de l'imperméabilité à l'eau des cuirs souples —
Partie 2: Compression angulaire répétée (Maeser)

Reference number
ISO 5403-2:2011(E)
IULTCS/IUP 10-2:2011(E)
©
ISO 2011
ISO 5403-2:2011(E)
IULTCS/IUP 10-2:2011(E)
©  ISO 2011
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means,
electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or
ISO's member body in the country of the requester.
ISO copyright office
Case postale 56  CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Published in Switzerland
ii © ISO 2011 – All rights reserved

ISO 5403-2:2011(E)
IULTCS/IUP 10-2:2011(E)
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies
(ISO member bodies). The work of preparing International Standards is normally carried out through ISO
technical committees. Each member body interested in a subject for which a technical committee has been
established has the right to be represented on that committee. International organizations, governmental and
non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the
International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.
International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2.
The main task of technical committees is to prepare International Standards. Draft International Standards
adopted by the technical committees are circulated to the member bodies for voting. Publication as an
International Standard requires approval by at least 75 % of the member bodies casting a vote.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. ISO shall not be held responsible for identifying any or all such patent rights.
ISO 5403-2 was prepared by the European Committee for Standardization (CEN) Technical Committee
CEN/TC 289, Leather, in collaboration with the Physical Test Commission of the International Union of
Leather Technologists and Chemists Societies (IUP Commission, IULTCS), in accordance with the Agreement
on technical cooperation between ISO and CEN (Vienna Agreement).
IULTCS, originally formed in 1897, is a world-wide organization of professional leather societies to further the
advancement of leather science and technology. IULTCS has three Commissions, which are responsible for
establishing international methods for the sampling and testing of leather. ISO recognizes IULTCS as an
international standardizing body for the preparation of test methods for leather.
ISO 5403 consists of the following parts, under the general title Leather — Determination of water resistance
of flexible leather:
 Part 1: Repeated linear compression (penetrometer)
 Part 2: Repeated angular compression (Maeser)

ISO 5403-2:2011(E)
INTERNATIONAL STANDARD
IULTCS/IUP 10-2:2011(E)
Leather — Determination of water resistance of flexible
leather —
Part 2:
Repeated angular compression (Maeser)
1 Scope
This part of ISO 5403 specifies a method for determining the dynamic water resistance of leather by means of
repeated angular compression. It is applicable to all flexible leathers but is particularly suitable for leathers
intended for footwear applications. It uses a Maeser-type machine and includes an option for electronic
detection.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.
ISO 2418, Leather — Chemical, physical and mechanical and fastness tests — Sampling location
ISO 2419, Leather — Physical and mechanical tests — Sample preparation and conditioning
ISO 3696:1987, Water for analytical laboratory use — Specification and test methods
3 Principle
A square test specimen is folded and secured in two V-shaped clamps which have closed ends so as to form
a trough. The trough is then immersed in water and the clamp at one end oscillates at a constant speed so
that the specimen is repeatedly flexed. The test is stopped at the first sign of water penetration through the
test specimen or by means of electronic detection.
NOTE This test method uses folding-type flexing, whereas the test method of ISO 5403-1 for water resistance
imparts compression-type flexing on the leather specimens. Given the two completely different flexing actions, it is not
possible to compare the results obtained from the two test methods.
4 Apparatus, reagents and materials
Usual laboratory apparatus is required and, in particular, the following.
4.1 Maeser-type machine, whith one or more pairs of V-shaped clamps, which are set 63 mm  3 mm
apart in the same horizontal plane, into which the test specimen can be clamped.
4.1.1 Each clamp shall have two parts as described in 4.1.1.1 and 4.1.1.2.
4.1.1.1 An outer part comprising a “V” form with an internal angle of 31°  1°, an internal tip radius of
7,5 mm  0,5 mm and a closed back to the “V” which is impermeable to water.
ISO 5403-2:2011(E)
IULTCS/IUP 10-2:2011(E)
4.1.1.2 An inner part having the shape and size that shall complement the outer part.
4.1.2 One clamp is stationary.
4.1.3 One clamp shall pivot about a point X which is midway (31,5 mm  1,5 mm) between the clamps such
that the lower end of the clamps move together (see Figure 1).
4.1.4 The pivot point X (see Figure 1) shall be 54,0 mm  0,5 mm above the internal face of the clamp at
the tip of the “V” and the flexing angle through which the clamp moves shall be 32°  2°.
Dimensions in millimetres
Key
1 stationary clamp
2 moveable clamp
3 test piece
X pivot point
Figure 1 — Side view of test specimen in V-shaped clamps
(tolerances on dimensions given in the text)
4.1.5 A method of applying a simple harmonic motion to the moveable clamp (4.1.3) so that it pivots toward
the stationary clamp (4.1.2) and back to its original position at a rate of (90  5) cycles/min.
4.1.6 A means of counting the number of cycles of the moveable clamp (4.1.3).
4.1.7 A method of containing a fixed quantity of water or electrolyte (4.3) around the two clamps (4.1.2 and
4.1.3) so that the water level can be adjusted to the recommended height.
4.2 Press knife, conforming to the requirements of ISO 2419, or other cutting device, capable of cutting
square test specimens at least 100 mm  100 mm so that they fit correctly into the V-clamps and can be fixed
so no water penetrates at the edge during the flexing.
4.3 Distilled or deionized water at (20  5) °C, of grade 3 in accordance with ISO 3696, or, if electronic
detection is used, an electrolyte comprising 1 g/l sodium chloride solution at (20  5) °C.
4.4 Thin strips of compressible impermeable material, such as soft rubber or plasticine, of width
approximately 10 mm and thickness approximately 1 mm, may be necessary to prevent water seeping
between the test specimen and the clamps (4.1.2 and 4.1.3).
2 © ISO 2011 – All rights reserved

ISO 5403-2:2011(E)
IULTCS/IUP 10-2:2011(E)
4.5 Rubber solution, or a similar type of compound, which may be necessary for sealing the edges of the
test specimens.
4.6 Electronic detection, if used.
4.6.1 Electrical system, using a high-potential electrode and a common electrode, and which shall stop the
test when water penetration is detected as a fall in resistance between the electrodes to below 50 000 . An
electrolyte (4.3) in contact with the leather specimen shall form the common electrode. The high-potential
electrode shall be in electrical contact with the steel balls (4.6.2).
4.6.2 Magnetic stainless steel balls, approximately 3 mm in diameter, to be maintained free of grease, oil,
silicone and rust. Keep the balls clean by treating them with a suitable chemical, followed, by rinsing them with
water and allowing them to air-dry.
NOTE Suitable cleaning chemicals are 5 % nitric acid or acetone.
4.7 Abrasive paper, grade P180, as defined in the P-series grit-size standard published by the Federation
of European Producers of Abrasive Products, cut into rectangles of 65 mm  5 mm  45 mm  5 mm, fixed to
a flat, rigid base of the same size and weighted to give a total mass of 1,0 kg  0,1 kg. A fresh piece of
abrasive paper shall be used for each test.
4.8 Magnet, used to remove steel balls from sample.
4.9 Balance, with an accuracy of 0,01 g if water absorption required.
5 Sampling and sample preparation
5.1 Sample in accordance with ISO 2418. Use the press knife (4.2) to cut two square test specimens of at
least 100 mm  100 mm so that one side of each specimen is parallel to the principal direction of the material.
5.2 Mark the principal direction of the material on each test specimen.
5.3 If it is considered that the test specimens are virtually impermeable through their thickness, but may be
prone to wicking along their length, seal all four edges of both test specimens with the rubber solution (4.5).
5.4 Store the test specimens in a standard controlled environment according to ISO 2419 for at least 48 h.
It is not necessary to
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.