EN 694:2001+A1:2007
(Main + Amendment)Fire-fighting hoses - Semi-rigid hoses for fixed systems
Fire-fighting hoses - Semi-rigid hoses for fixed systems
This European standard specifies the requirements and the tests methods for semi-rigid reel hoses for fire fighting purposes for use with fixed systems. The hoses are intended for use at a maximum working pressure of 1,2 MPa for hoses of 19 mm and 25 mm inside diameter and 0,7 MPa for hoses of 33 mm inside diameter. Hoses conforming to this standard are intended for applications where long intervals can occur between the occasions of use, for example on fixed fire hose reels in buildings and other construction works.
Feuerlöschschläuche - Formstabile Schläuche für Wandhydranten
In dieser Europäischen Norm werden die Anforderungen und Prüfverfahren für formstabile Haspel¬schläuche, die an Wandhydranten angeschlossen sind und zu Feuerlöschzwecken eingesetzt werden, festgelegt. Schläuche mit einem Innendurchmesser von 19 mm und 25 mm sind für einen maximalen Arbeitsdruck von 1,2 MPa, Schläuche mit einem Innendurchmesser von 33 mm für einen maximalen Arbeitsdruck von 0,7 MPa vorgesehen.
Schläuche, die die Anforderungen dieser Norm erfüllen, sind für Verwendungen vorgesehen, bei denen lange Zeiträume zwischen den einzelnen Gebrauchsfällen liegen können, z. B. auf fest installierten Schlauchhaspeln in Gebäuden oder anderen baulichen Anlagen.
Die Norm gilt ausschließlich für Feuerlöschschläuche zur Brandbekämpfung, die für einen Einsatz bei Umgebungsbedingungen in nicht-aggressiven und nicht-korrosiven Atmosphären innerhalb des Temperaturbereichs von -20 °C bis +60 °C vorgesehen sind.
ANMERKUNG 1 Schläuche für die Verwendung bei Temperaturen unter -20 °C dürfen auf Kundenanfrage geliefert werden.
ANMERKUNG 2 Sämtliche Drücke werden in Megapascal angegeben. 1 MPa = 10 bar.
Tuyaux de lutte contre l'incendie - Tuyaux semi-rigides pour systèmes fixes
La présente Norme européenne spécifie les exigences et méthodes d'essai s'appliquant aux tuyaux semi rigides de lutte contre l'incendie prévus pour des systèmes fixes. Les tuyaux sont prévus pour être utilisés sous une pression maximale de service de 1,2 MPa pour les diamètres intérieurs 19 mm et 25 mm et de 0,7 MPa pour le diamètre intérieur 33 mm.
Les tuyaux conformes à la présente norme sont destinés à des applications où il peut s'écouler de longues périodes entre deux utilisations, par exemple sur robinets d’incendie armés dans les bâtiments et autres constructions.
La présente Norme concerne uniquement les tuyaux de lutte contre l'incendie prévus pour être utilisés dans les conditions ambiantes atmosphères agressives ou corrosives exclues dans une plage de température comprise entre - 20 °C et + 60 °C.
NOTE 1 Des tuyaux pour utilisation à des températures inférieures à - 20 °C peuvent être fournis sur demande de l'acheteur.
NOTE 2 Toutes les pressions sont exprimées en mégapascals : 1 MPa = 10 bar.
Gasilske cevi - Poltoge cevi za vgrajene sisteme
General Information
Relations
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Fire-fighting hoses - Semi-rigid hoses for fixed systemsGasilske cevi - Poltoge cevi za vgrajene sistemeTuyaux de lutte contre l'incendie - Tuyaux semi-rigides pour systemes fixesFeuerlöschschläuche - Formstabile Schläuche für WandhydrantenTa slovenski standard je istoveten z:EN 694:2001+A1:2007SIST EN 694:2002+A1:2007en;fr;de23.040.70Gumene cevi in armatureHoses and hose assemblies13.220.10Gašenje požaraFire-fightingICS:SLOVENSKI
STANDARDSIST EN 694:2002+A1:200701-julij-2007
EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 694:2001+A1
April 2007 ICS 13.220.10; 23.040.70 Supersedes EN 694:2001English Version
Fire-fighting hoses - Semi-rigid hoses for fixed systems
Tuyaux de lutte contre l'incendie - Tuyaux semi-rigides pour systèmes fixes
Feuerlöschschläuche - Formstabile Schläuche für Wandhydranten This European Standard was approved by CEN on 31 August 2000 and includes Amendment 1 approved by CEN on 12 March 2007 and Corrigendum 2 issued in 2003.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre: rue de Stassart, 36
B-1050 Brussels © 2007 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 694:2001+A1:2007: E
Kink pressure test.11 Annex B (normative)
Accelerated ageing test.12 Annex C (normative)
Hot surface resistance test.13 Annex D (normative)
Bending and crush resistance test.17 Annex E (normative) !!!!Frequencies of testing (type test and production test).19 Annex F (informative) !!!!Frequencies of testing (batch test).20 Bibliography.21
which may be coupled with assessment of a supplier’s quality system against EN ISO 9001. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.
1 Scope This European Standard specifies the requirements and test methods for semi-rigid reel hoses for fire-fighting purposes for use with fixed systems. The hoses are intended for use at a maximum working pressure of 1,2 MPa for hoses of 19 mm and 25 mm inside diameter and 0,7 MPa for hoses of 33 mm inside diameter. Hoses conforming to this standard are intended for applications where long intervals can occur between the occasions of use, for example on fixed fire hose reels in buildings and other construction works. The standard applies exclusively to hoses for fire-fighting purposes intended for use at ambient conditions in non-aggressive or non-corrosive atmospheres within the temperature range -20 °C to +60 °C. NOTE 1 Hoses for use at temperatures lower than -20 °C may be supplied at the request of the purchaser. NOTE 2 All pressures are expressed in megapascals. 1 MPa = 10 bar. 2 Normative references This European Standard incorporates by dated or undated reference, provisions from other publications. These normative references are cited at the appropriate places in the text and the publications are listed hereafter. For dated references, subsequent amendments to or revisions of any of these publications apply to this European Standard only when incorporated in it by amendment or revision. For undated references, the latest edition of the publication referred to applies (including amendments). EN 24672:1993, Rubber and plastics hoses - Sub-ambiant temperature flexibility tests (ISO 4672:1988) EN 27326:1993, Rubber and plastics hoses - Assessment of ozone resistance under static conditions (ISO 7326:1991) EN 28033, Rubber and plastics hose - Determination of adhesion between components (ISO 8033:1991) EN ISO 1307, Rubber and plastics hoses for general-purpose industrial applications - Bore diameters and tolerances, and tolerances on length (ISO 1307:1992) EN ISO 1402, Rubber and plastics hoses and hose assemblies - Hydrostatic testing (ISO 1402:1994) ISO 176:1976, Plastics - Determination of loss of plasticizers - Activated carbon method ISO 188, Rubber, vulcanized or thermoplastic - Accelerated ageing and heat-resistance tests ISO 4671:1984, Rubber and plastics hose and hose assemblies - Methods of measurement of dimensions ISO 8330:1998, Rubber and plastics hoses and hose assemblies - Vocabulary
3 Definitions For the purposes of this standard the following definition applies, together with those for working pressure, proof pressure and burst pressure given in ISO 8330:1998. 3.1 semi-rigid hose hose which maintains its round cross-section even when unpressurized 4 Classification 4.1 General All types and classes of hoses shall be so flexible that they can be rolled and kept on a drum of minimum diameter 200 mm for 19 mm and 25 mm inside diameter hose and of minimum diameter 280 mm for 33 mm inside diameter hose. Hoses shall be one of two types distinguished by their construction. Each hose type shall be further divided into classes distinguished by the materials used for lining and cover. 4.2 Classification by types (hose construction) Type A hoses shall consist of: a) a seamless rubber or plastics lining;
b) a textile reinforcement with or without a rigid spiral helix; c) a rubber or plastics cover. Type B hoses shall consist of: a) a seamless rubber or plastics lining; b) a circular woven textile reinforcement with a rigid spiral helix; c) an uncovered or rubber or plastics cover. 4.3 Classification by class (materials for lining and cover) The hose types shall be further subdivided into six classes dependent on the materials used in the construction in accordance with Table 1.
Table 1 — Classes and materials Class Lining materialCover material 1 rubber rubber 2 plastics plastics 3 rubber plastics 4 plastics rubber 5 rubber no cover 6 plastics no cover
5 Dimensions, tolerances and maximum mass 5.1 Inside diameter and maximum mass The inside diameter of the hose, when measured in accordance with ISO 4671, shall conform to the requirements given in Table 2. The mass per metre length of the hose shall be in accordance with Table 2. Table 2 — Inside diameter, tolerances on inside diameter and maximum mass per unit lengthInside diameter
Tolerances for inside diameter Mass per unit length mm mm kg/m
Type AType B
max. max. 19 -0,5 to +1,0 0,75 0,25 25 ±1,0
0,90 0,35 33 -1,0 to +1,5 1,00 0,50
5.2 Length and tolerances on length The total length of hose supplied shall be in accordance with the purchaser’s requirements and shall be stated in metres. Tolerance on length shall be in accordance with EN ISO 1307. 6 Performance requirements of finished hose 6.1 Hydrostatic requirements 6.1.1 Deformation under maximum working pressure The dimensional stability of the hose, when tested in accordance with EN ISO 1402, shall conform to the requirements given in Table 3. The length of the test piece shall be 1 m.
For 19 mm and 25 mm inside diameter hoses the initial test pressure shall be 0,07 MPa and the final test pressure shall be 1,2 MPa. For 33 mm inside diameter hose the initial test pressure shall be 0,07 MPa and the fin
...