Thermal solar systems and components - Solar collectors - Part 1: General Requirements

This European Standard specifies requirements on durability (including mechanical strength), reliability and safety for liquid heating solar collectors. It also includes provisions for evaluation of conformity to these requirements.
It is not applicable to those collectors in which the thermal storage unit is an integral part of the collector to such an extent, that the collection process cannot be separated from the storage process for the purpose of making measurements of these two processes. It is not applicable to tracking concentrating solar collectors.
Collectors that are custom-built (built in, roof integrated collectors that do not comprise factory made modules and are assembled directly on the place of installation) cannot be tested in their actual form for durability, reliability and thermal performance according to this standard. Instead, a module with the same structure as the ready collector is tested. The module gross area in the case of custom built collectors should be at least 2 m2. The test is valid only for larger collectors, than the tested module.
For collectors the national and European Guidelines for Structural Planning and overhead glazing are not valid. Therefore this standard should be applied for the design of the static of the collector.

Thermische Solaranlagen und ihre Bauteile - Kollektoren - Teil 1: Allgemeine Anforderungen

Diese Europäische Norm legt für Flüssigkeitskollektoren Anforderungen hinsichtlich der Dauerhaftigkeit (einschließlich der mechanischen Festigkeit), der Zuverlässigkeit und Sicherheit fest. Sie enthält auch Vorgaben, um die Konformität mit diesen Anforderungen zu bewerten.
Die Norm ist nicht auf Kollektoren anwendbar, bei denen der Wärmespeicher in einem solchen Maße in den Kollektor integriert ist, dass bei der Durchführung von Messungen der Prozess im Kollektor vom Prozess der Wärmespeicherung nicht getrennt werden kann. Die Norm gilt nicht für nachgeführte konzentrierende Kollektoren.
Kundenspezifische Kollektoren (in der Dacheindeckung integrierte Kollektoren, die keine industriell hergestellten Module enthalten und direkt am Einsatzort zusammengestellt werden), können in ihrer ursprünglichen Form in Bezug auf Dauerhaftigkeit, Zuverlässigkeit und Wärmeleistung nicht nach dieser Norm geprüft werden. An ihrer Stelle wird ein Modul geprüft werden, das die gleiche Bauweise wie der fertig montierte Kollektor aufweist. Die Bruttofläche des Moduls muss mindestens 2 m2 betragen. Die Prüfung ist nur für Kollektoren gültig, die größer sind als das geprüfte Modul.

Installations solaires thermiques et leurs composants - Capteurs solaires - Partie 1 : Exigences générales

La présente Norme européenne spécifie les exigences de durabilité (y compris la résistance mécanique), de fiabilité et de sécurité pour des capteurs solaires à circulation de liquide. Elle contient également des dispositions pour l'évaluation de la conformité à ces exigences.
Elle ne s'applique pas aux capteurs dont le dispositif de stockage thermique fait partie intégrante dans la mesure où les opérations de captage et de stockage de l'énergie ne peuvent pas être séparées en vue d'effectuer des mesures nécessaires. Elle ne s'applique pas aux capteurs solaires suiveurs à concentration.
La durabilité, la fiabilité et les performances thermiques des capteurs fabriqués à façon (capteurs intégrés ou incorporés en toiture qui ne sont pas composés de modules fabriqués en usine et qui sont assemblés directement sur le lieu d'installation) ne peuvent pas, dans la forme actuelle de ces capteurs, être contrôlées conformément à la présente norme. A leur place, on soumet aux essais un module ayant la même structure que le capteur monté. Il est recommandé que la superficie hors-tout des modules de capteurs fabriqués à façon soit d'au moins 2 m2. L’essai n’est valable que pour les capteurs plus grands que le module soumis à l’essai.
Les Directives nationales et européennes relatives à l’étude de structures de bâtiments et à l’utilisation des vitrages horizontaux ou inclinés ne s’appliquent pas aux capteurs solaires. Il convient donc d’appliquer la présente norme pour la conception mécanique du capteur

Toplotni sončni sistemi in sestavni deli - Sprejemniki sončne energije - 1. del: Splošne zahteve

General Information

Status
Withdrawn
Publication Date
28-Mar-2006
Withdrawal Date
12-Oct-2010
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
13-Oct-2010
Completion Date
13-Oct-2010

Relations

Buy Standard

Standard
EN 12975-1:2006
English language
15 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 12975-1:2006
01-maj-2006
1DGRPHãþD
SIST EN 12975-1:2002
7RSORWQLVRQþQLVLVWHPLLQVHVWDYQLGHOL6SUHMHPQLNLVRQþQHHQHUJLMHGHO
6SORãQH]DKWHYH
Thermal solar systems and components - Solar collectors - Part 1: General
Requirements
Thermische Solaranlagen und ihre Bauteile - Kollektoren - Teil 1: Allgemeine
Anforderungen
Installations solaires thermiques et leurs composants - Capteurs solaires - Partie 1 :
Exigences générales
Ta slovenski standard je istoveten z: EN 12975-1:2006
ICS:
27.160 6RQþQDHQHUJLMD Solar energy engineering
SIST EN 12975-1:2006 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 12975-1:2006

---------------------- Page: 2 ----------------------

SIST EN 12975-1:2006
EUROPEAN STANDARD
EN 12975-1
NORME EUROPÉENNE
EUROPÄISCHE NORM
March 2006
ICS 27.160 Supersedes EN 12975-1:2000
English Version
Thermal solar systems and components - Solar collectors - Part
1: General Requirements
Installations solaires thermiques et leurs composants - Thermische Solaranlagen und ihre Bauteile - Kollektoren -
Capteurs solaires - Partie 1 : Exigences générales Teil 1: Allgemeine Anforderungen
This European Standard was approved by CEN on 6 February 2006.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national
standards may be obtained on application to the Central Secretariat or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CEN member into its own language and notified to the Central Secretariat has the same status as the official
versions.
CEN members are the national standards bodies of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France,
Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania,
Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre: rue de Stassart, 36  B-1050 Brussels
© 2006 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 12975-1:2006: E
worldwide for CEN national Members.

---------------------- Page: 3 ----------------------

SIST EN 12975-1:2006
EN 12975-1:2006 (E)
Contents Page
Foreword .3
Introduction.4
1 Scope.5
2 Normative references.5
3 Terms and definitions.5
4 Symbols and units .5
5 Durability and reliability.5
5.1 Materials and design.5
5.2 Required tests.5
5.3 Pass criteria.6
5.3.1 General.6
5.3.2 Internal pressure for absorber .7
5.3.3 High temperature resistance.7
5.3.4 Exposure.7
5.3.5 External thermal shock.
...