EN 15814:2011+A2:2014
(Main)Polymer modified bituminous thick coatings for waterproofing - Definitions and requirements
Polymer modified bituminous thick coatings for waterproofing - Definitions and requirements
This European Standard specifies the definitions and requirements of prefabricated polymer modified bituminous thick coatings used for the waterproofing of below ground structures. It applies to both one-component and two-component products. These products can be used with or without inlay.
This European Standard does not apply to products that are to be used for roof waterproofing.
Kunststoffmodifizierte Bitumendickbeschichtungen zur Bauwerksabdichtung - Begriffe und Anforderungen
Diese Europäische Norm legt die Begriffe und Anforderungen für vorgefertigte kunststoffmodifizierte Bitumendickbeschichtungen zur Abdichtung von erdberührten Bauteilen fest. Sie gilt sowohl für Einkomponenten- als auch für Zweikomponentenprodukte. Diese Produkte können mit oder ohne Einlage verwendet werden.
Diese Europäische Norm gilt nicht für Produkte, die zur Dachabdichtung verwendet werden.
Revêtements bitumineux épais modifiés aux polymères pour imperméabilisation - Définitions et exigences
La présente Norme européenne donne les définitions et les exigences relatives aux revêtements bitumineux épais modifiés aux polymères utilisés pour l'imperméabilisation des structures enterrées. Elle s'applique aux produits à un composant et à deux composants. Ces produits peuvent être utilisés avec ou sans renfort.
La présente Norme européenne ne s'applique pas aux produits utilisés pour l’étanchéité des toitures.
Bitumenske debeloslojne prevleke, modificirane s polimeri - Definicije in zahteve
Ta evropski standard določa definicije in zahteve za predizdelane bitumenske debeloslojne prevleke, modificirane s polimeri, za tesnjenje. Velja tako za enokomponentne kot za dvokomponentne izdelke. Ti izdelki se lahko uporabljajo z vložkom ali brez njega. Ta evropski standard ne velja za izdelke, ki so namenjeni tesnjenju streh.
General Information
Relations
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Bitumenske debeloslojne prevleke, modificirane s polimeri - Definicije in zahteveKunststoffmodifizierte Bitumendickbeschichtungen zur Bauwerksabdichtung - Begriffe und AnforderungenRevêtements bitumineux épais modifiés aux polymères pour imperméabilisation - Définitions et exigencesPolymer modified bituminous thick coatings for waterproofing - Definitions and requirements91.100.50Veziva. Tesnilni materialiBinders. Sealing materialsICS:Ta slovenski standard je istoveten z:EN 15814:2011+A2:2014SIST EN 15814:2011+A2:2015en,fr,de01-marec-2015SIST EN 15814:2011+A2:2015SLOVENSKI
STANDARDSIST EN 15814:2011+A1:20121DGRPHãþD
EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 15814:2011+A2
December 2014 ICS 91.100.50 Supersedes EN 15814:2011+A1:2012
English Version
Polymer modified bituminous thick coatings for waterproofing - Definitions and requirements
Revêtements bitumineux épais modifiés aux polymères pour imperméabilisation - Définitions et exigences
Kunststoffmodifizierte Bitumendickbeschichtungen zur Bauwerksabdichtung - Begriffe und Anforderungen This European Standard was approved by CEN on 14 July 2011 and includes Amendment 1 approved by CEN on 20 August 2012 and Amendment 2 approved by CEN on 6 October 2014.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre:
Avenue Marnix 17,
B-1000 Brussels © 2014 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 15814:2011+A2:2014 E SIST EN 15814:2011+A2:2015
Reaction to fire — Specifications for mounting specimens in the test rigs . 15 Annex ZA (informative)
#Clauses of this European Standard addressing provisions of the EU Construction Products Regulation (CPR) . 16 ZA.1 Scope and relevant characteristics . 16 ZA.2 Procedures for AVCP of the PMBC . 17 ZA.2.1 Systems of AVCP . 17 ZA.2.2 Declaration of performance (DoP) . 19 ZA.2.2.1 General . 19 ZA.2.2.2 Content . 20 ZA.2.2.3 Example of DoP . 21 ZA.3 CE marking and labelling$ . 24 #Bibliography$ . 26
Crack width ≥ 1 mm dry layer thickness
≥ 3 mm (MLV) Class CB 2 No damage
Crack width ≥ 2 mm dry layer thickness
≥ 3 mm (MLV) EN 15812 Method A or B NOTE The test method has to be declared with the classification.
2 Resistance to rain Class R0 No require-ment
Class R1 ≤ 24 h
wet layer thickness ≥ 3 mm (MLV) Class R2 ≤ 8 h
wet layer thickness ≥ 3 mm (MLV) Class R3 ≤ 4 h
wet layer
thickness ≥ 3 mm (MLV) EN 15816 3 Water resistance 1.No colouration of the water 2.No debonding from inlay, if used dry layer ≥ 4 mm #3. No changes to the material$ EN 15817 4 Flexibility at low temperature !deleted text" No cracks EN 15813 5 Dimensional stability at high temperature !deleted text" No sliding or draining down EN 15818 6 Reduction of layer thickness when fully dried ≤ 50 % (MLV) EN 15819 7 Reaction to fire Class to be declared according to EN 13501-1
Testing in accordance with the specifications in the classification standard EN 13501-1and Annex A.
thickness without inlay ≥ 3 mm (MLV) Class W2A ≥ 72 h at 0,075 N/mm2 dry layer thickness with inlay ≥ 4 mm with inlay (MLV) Class W2B ≥ 72 h at
0,075 N/mm2 dry layer thickness without inlay ≥ 4 mm without inlay (MLV) EN 15820 9 Resistance to compression a Class C0 No requirement Class C1 Stabilization a
...