EN ISO 10893-10:2011
(Main)Non-destructive testing of steel tubes - Part 10: Automated full peripheral ultrasonic testing of seamless and welded (except submerged arc-welded) steel tubes for the detection of longitudinal and/or transverse imperfections (ISO 10893-10:2011)
Non-destructive testing of steel tubes - Part 10: Automated full peripheral ultrasonic testing of seamless and welded (except submerged arc-welded) steel tubes for the detection of longitudinal and/or transverse imperfections (ISO 10893-10:2011)
ISO 10893-10:2011 specifies requirements for automated full peripheral ultrasonic shear wave (generated by conventional or phased array technique) testing of seamless and welded [except submerged arc-welded (SAW)] steel tubes, for the detection of longitudinal and/or transverse imperfections.
In the case of testing on longitudinal imperfections, Lamb wave testing can be applied at the discretion of the manufacturer.
For seamless tubes, by agreement between the purchaser and manufacturer, testing principles of ISO 10893-10:2011 can be applied to detect imperfections having other orientations.
ISO 10893-10:2011 is applicable to the inspection of tubes with an outside diameter greater than or equal to 10 mm, normally with an outside diameter-to-thickness ratio greater than or equal to 5.
It can also be applicable to the testing of circular hollow sections.
Zerstörungsfreie Prüfung von Stahlrohren - Teil 10: Automatisierte Ultraschallprüfung nahtloser und geschweißter (ausgenommen unterpulvergeschweißter) Stahlrohre über den gesamten Rohrumfang zum Nachweis von Unvollkommenheiten in Längs- und/oder Querrichtung (ISO 10893-10:2011)
Dieser Teil der ISO 10893 legt die Anforderungen an die automatisierte Ultraschallprüfung unter Anwendung von
Tranversalwellen (erzeugt mittels konventioneller oder mittels Phased-Array-Technik) über den gesamten Umfang
nahtloser und geschweißter Stahlrohre, mit Ausnahme unterpulvergeschweißter (SAW)-Rohre, zum Nachweis von
Unvollkommenheiten in Längs- und/oder Querrichtung fest.
Wenn bei der Bestellung nichts anderes festgelegt wurde, gilt das Prüfverfahren für den Nachweis vorwiegend in
Längsrichtung orientierter Unvollkommenheiten.
Bei Prüfung auf Unvollkommenheiten in Längsrichtung darf nach Wahl des Herstellers mit Plattenwellen geprüft
werden.
Bei nahtlosen Rohren dürfen die Prüfprinzipien dieses Teils der ISO 10893 auch zum Nachweis von
Unvollkommenheiten mit anderer Orientierung angewendet werden.
Dieser Teil der ISO 10893 ist anwendbar für die Prüfung von Rohren mit einem Außendurchmesser ab 10 mm,
üblicherweise mit einem Außendurchmesser-Wanddicken-Verhältnis ab 5.
ANMERKUNG 1 Optionen für die Prüfung von Rohren mit einem Außendurchmesser-Wanddicken-Verhältnis unter 5 auf
Unvollkommenheiten in Längsrichtung sind im Anhang A festgelegt.
Dieses Dokument kann auch für die Prüfung von kreisförmigen Hohlprofilen angewendet werden.
Essais non destructifs des tubes en acier - Partie 10: Contrôle automatisé par ultrasons sur toute la circonférence des tubes en acier sans soudure et soudés (sauf à l'arc immergé sous flux en poudre) pour la détection des imperfections longitudinales et/ou transversales (ISO 10893-10:2011)
L'ISO 10893-10:2011 spécifie les exigences relatives au contrôle automatisé par ultrasons, avec ondes de cisaillement (générées par une technique conventionnelle ou la technique des réseaux à commande de phase), sur toute la circonférence des tubes en acier sans soudure et soudés [sauf à l'arc immergé sous flux en poudre (SAW)], pour la détection des imperfections longitudinales et/ou transversales.
Dans le cas du contrôle d'imperfections longitudinales, un contrôle par ondes de Lamb peut être appliqué au choix du producteur.
Pour les tubes sans soudure, par accord entre l'acheteur et le producteur, les principes de contrôle de l'ISO 10893-10:2011 peuvent être appliqués pour détecter des imperfections ayant d'autres orientations.
L'ISO 10893-10:2011 s'applique au contrôle des tubes ayant un diamètre extérieur supérieur ou égal à 10 mm et, normalement, un rapport diamètre extérieur/épaisseur supérieur ou égal à 5.
Elle est également applicable au contrôle des profils creux circulaires.
Neporušitveno preskušanje jeklenih cevi - 10. del: Avtomatizirano ultrazvočno preskušanje in odkrivanje vzdolžnih in/ali prečnih nepravilnosti po celotnem obodu nevarjenih in varjenih jeklenih cevi (razen obločno varjenih pod praškom) (ISO 10893-10:2011)
Ta del ISO 10893 določa zahteve za avtomatsko odkrivanje vzdolžnih/prečnih napak po celotnem obodu nevarjenih in varjenih jeklenih cevi [razen jeklenih cevi, obločno varjenih pod praškom (SAW)] z ultrazvočnim strižnim valovanjem (ki nastaja s konvencionalno tehniko ali tehniko faznih nizov). Razen če je v dobavnici določeno drugače, preskusna metoda velja predvsem za odkrivanje vzdolžnih napak. Pri preskušanju vzdolžnih napak se po presoji proizvajalca lahko uporabi preskušanje z Lambovim valovanjem. Po dogovoru med kupcem in proizvajalcem se lahko za odkrivanje napak z drugačno orientacijo pri nevarjenih ceveh uporabijo načela preskušanja tega dela ISO 10893. Ta del ISO 10893 velja za pregled cevi z zunanjim premerom, večjim ali enakim 10 mm, običajno z razmerjem med zunanjim premerom in debelino, večjim ali enakim 5. Ta del ISO 10893 lahko velja tudi za preskušanje krožnih votlih delov.
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
01-november-2011
Nadomešča:
SIST EN 10246-6:2000
SIST EN 10246-7:2005
Neporušitveno preskušanje jeklenih cevi - 10. del: Avtomatizirano ultrazvočno
preskušanje in odkrivanje vzdolžnih in/ali prečnih nepravilnosti po celotnem
obodu nevarjenih in varjenih jeklenih cevi (razen obločno varjenih pod praškom)
(ISO 10893-10:2011)
Non-destructive testing of steel tubes - Part 10: Automated full peripheral ultrasonic
testing of seamless and welded (except submerged arc-welded) steel tubes for the
detection of longitudinal and/or transverse imperfections (ISO 10893-10:2011)
Zerstörungsfreie Prüfung von Stahlrohren - Teil 10: Automatisierte Ultraschallprüfung
nahtloser und geschweißter (ausgenommen unterpulvergeschweißter) Stahlrohre über
den gesamten Rohrumfang zum Nachweis von Unvollkommenheiten in Längs- und/oder
Querrichtung (ISO 10893-10:2011)
Essais non destructifs des tubes en acier - Partie 10: Contrôle automatisé par ultrasons
sur toute la circonférence des tubes en acier sans soudure et soudés (sauf à l'arc
immergé sous flux en poudre) pour la détection des imperfections longitudinales et/ou
transversales (ISO 10893-10:2011)
Ta slovenski standard je istoveten z: EN ISO 10893-10:2011
ICS:
23.040.10 Železne in jeklene cevi Iron and steel pipes
77.040.20 Neporušitveno preskušanje Non-destructive testing of
kovin metals
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EUROPEAN STANDARD
EN ISO 10893-10
NORME EUROPÉENNE
EUROPÄISCHE NORM
April 2011
ICS 23.040.10; 77.040.20; 77.140.75 Supersedes EN 10246-6:1999, EN 10246-7:2005
English Version
Non-destructive testing of steel tubes - Part 10: Automated full
peripheral ultrasonic testing of seamless and welded (except
submerged arc-welded) steel tubes for the detection of
longitudinal and/or transverse imperfections (ISO 10893-
10:2011)
Essais non destructifs des tubes en acier - Partie 10: Zerstörungsfreie Prüfung von Stahlrohren - Teil 10:
Contrôle automatisé par ultrasons sur toute la
Automatisierte Ultraschallprüfung nahtloser und
circonférence des tubes en acier sans soudure et soudés geschweißter (ausgenommen unterpulvergeschweißter)
(sauf à l'arc immergé sous flux en poudre) pour la détection Stahlrohre über den gesamten Rohrumfang zum Nachweis
des imperfections longitudinales et/ou transversales (ISO von Unvollkommenheiten in Längs- und/oder Querrichtung
10893-10:2011) (ISO 10893-10:2011)
This European Standard was approved by CEN on 10 December 2010.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national
standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same
status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland,
Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2011 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN ISO 10893-10:2011: E
worldwide for CEN national Members.
Contents Page
Foreword .3
Foreword
This document (EN ISO 10893-10:2011) has been prepared by Technical Committee ISO/TC 17 "Steel" in
collaboration with Technical Committee ECISS/TC 110 “Steel tubes, and iron and steel fittings” the secretariat
of which is held by UNI.
This European Standard shall be given the status of a national standard, either by publication of an identical
text or by endorsement, at the latest by October 2011, and conflicting national standards shall be withdrawn at
the latest by October 2011.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights.
This document supersedes EN 10246-6:1999, EN 10246-7:2005.
According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following
countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech
Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain,
Sweden, Switzerland and the United Kingdom.
Endorsement notice
The text of ISO 10893-10:2011 has been approved by CEN as a EN ISO 10893-10:2011 without any
modification.
INTERNATIONAL ISO
STANDARD 10893-10
First edition
2011-04-01
Non-destructive testing of steel tubes —
Part 10:
Automated full peripheral ultrasonic
testing of seamless and welded (except
submerged arc-welded) steel tubes for
the detection of longitudinal and/or
transverse imperfections
Essais non destructifs des tubes en acier —
Partie 10: Contrôle automatisé par ultrasons sur toute la circonférence
des tubes en acier sans soudure et soudés (sauf à l'arc immergé sous
flux en poudre) pour la détection des imperfections longitudinales et/ou
transversales
Reference number
ISO 10893-10:2011(E)
©
ISO 2011
ISO 10893-10:2011(E)
PDF disclaimer
This PDF file may contain embedded typefaces. In accordance with Adobe's licensing policy, this file may be printed or viewed but
shall not be edited unless the typefaces which are embedded are licensed to and installed on the computer performing the editing. In
downloading this file, parties accept therein the responsibility of not infringing Adobe's licensing policy. The ISO Central Secretariat
accepts no liability in this area.
Adobe is a trademark of Adobe Systems Incorporated.
Details of the software products used to create this PDF file can be found in the General Info relative to the file; the PDF-creation
parameters were optimized for printing. Every care has been taken to ensure that the file is suitable for use by ISO member bodies. In
the unlikely event that a problem relating to it is found, please inform the Central Secretariat at the address given below.
© ISO 2011
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means,
electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or
ISO's member body in the country of the requester.
ISO copyright office
Case postale 56 • CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Published in Switzerland
ii © ISO 2011 – All rights reserved
ISO 10893-10:2011(E)
Contents Page
Foreword .iv
1 Scope.1
2 Normative references.1
3 Terms and definitions .2
4 General requirements .3
5 Test method .3
6 Reference tube.4
6.1 General .4
6.2 Types of reference notches.4
6.3 Dimensions of reference notches.5
7 Equipment calibration and checking.6
7.1 General .6
7.2 Adjustment of trigger/alarm level .6
7.3 Calibration check and recalibration .7
8 Acceptance .7
9 Test report.8
Annex A (normative) Testing on longitudinal imperfections of tubes with a ratio of the specified
outside diameter to the average of the specified thickness range less than 5 .9
Annex B (normative) Manual/semi-automated testing of untested ends and suspect areas .11
ISO 10893-10:2011(E)
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies
(ISO member bodies). The work of preparing International Standards is normally carried out through ISO
technical committees. Each member body interested in a subject for which a technical committee has been
established has the right to be represented on that committee. International organizations, governmental and
non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the
International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.
International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2.
The main task of technical committees is to prepare International Standards. Draft International Standards
adopted by the technical committees are circulated to the member bodies for voting. Publication as an
International Standard requires approval by at least 75 % of the member bodies casting a vote.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. ISO shall not be held responsible for identifying any or all such patent rights.
ISO 10893-10 was prepared by Technical Committee ISO/TC 17, Steel, Subcommittee SC 19, Technical
delivery conditions for steel tubes for pressure purposes.
This first edition cancels and replaces ISO 9303:1989 and ISO 9305:1989, which have been technically
revised.
ISO 10893 consists of the following parts, under the general title Non-destructive testing of steel tubes:
⎯ Part 1: Automated electromagnetic testing of seamless and welded (except submerged arc-welded) steel
tubes for the verification of hydraulic leaktightness
⎯ Part 2: Automated eddy current testing of seamless and welded (except submerged arc-welded) steel
tubes for the detection of imperfections
⎯ Part 3: Automated full peripheral flux leakage testing of seamless and welded (except submerged
arc-welded) ferromagnetic steel tubes for the detection of longitudinal and/or transverse imperfections
⎯ Part 4: Liquid penetrant inspection of seamless and welded steel tubes for the detection of surface
imperfections
⎯ Part 5: Magnetic particle inspection of seamless and welded ferromagnetic steel tubes for the detection of
surface imperfections
⎯ Part 6: Radiographic testing of the weld seam of welded steel tubes for the detection of imperfections
⎯ Part 7: Digital radiographic testing of the weld seam of welded steel tubes for the detection of
imperfections
⎯ Part 8: Automated ultrasonic testing of seamless and welded steel tubes for the detection of laminar
imperfections
⎯ Part 9: Automated ultrasonic testing for the detection of laminar imperfections in strip/plate used for the
manufacture of welded steel tubes
⎯ Part 10: Automated full peripheral ultrasonic testing of seamless and welded (except submerged
arc-welded) steel tubes for the detection of longitudinal and/or transverse imperfections
iv © ISO 2011 – All rights reserved
ISO 10893-10:2011(E)
⎯ Part 11: Automated ultrasonic testing of the weld seam of welded steel tubes for the detection of
longitudinal and/or transverse imperfections
⎯ Part 12: Automated full peripheral ultrasonic thickness testing of seamless and welded (except
submerged arc-welded) steel tubes
---
...
SLOVENSKI STANDARD
01-november-2011
1DGRPHãþD
SIST EN 10246-6:2000
SIST EN 10246-7:2005
1HSRUXãLWYHQRSUHVNXãDQMHMHNOHQLKFHYLGHO$YWRPDWVNRRGNULYDQMH
Y]GROåQLKSUHþQLKQDSDNSRFHORWQHPRERGXQHYDUMHQLKLQYDUMHQLKMHNOHQLKFHYL
UD]HQREORþQRYDUMHQLKSRGSUDãNRP]XOWUD]YRNRP,62
Non-destructive testing of steel tubes - Part 10: Automated full peripheral ultrasonic
testing of seamless and welded (except submerged arc-welded) steel tubes for the
detection of longitudinal and/or transverse imperfections (ISO 10893-10:2011)
Zerstörungsfreie Prüfung von Stahlrohren - Teil 10: Automatisierte Ultraschallprüfung
nahtloser und geschweißter (ausgenommen unterpulvergeschweißter) Stahlrohre über
den gesamten Rohrumfang zum Nachweis von Unvollkommenheiten in Längs- und/oder
Querrichtung (ISO 10893-10:2011)
Essais non destructifs des tubes en acier - Partie 10: Contrôle automatisé par ultrasons
sur toute la circonférence des tubes en acier sans soudure et soudés (sauf à l'arc
immergé sous flux en poudre) pour la détection des imperfections longitudinales et/ou
transversales (ISO 10893-10:2011)
Ta slovenski standard je istoveten z: EN ISO 10893-10:2011
ICS:
23.040.10 Železne in jeklene cevi Iron and steel pipes
77.040.20 Neporušitveno preskušanje Non-destructive testing of
kovin metals
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EUROPEAN STANDARD
EN ISO 10893-10
NORME EUROPÉENNE
EUROPÄISCHE NORM
April 2011
ICS 23.040.10; 77.040.20; 77.140.75 Supersedes EN 10246-6:1999, EN 10246-7:2005
English Version
Non-destructive testing of steel tubes - Part 10: Automated full
peripheral ultrasonic testing of seamless and welded (except
submerged arc-welded) steel tubes for the detection of
longitudinal and/or transverse imperfections (ISO 10893-
10:2011)
Essais non destructifs des tubes en acier - Partie 10: Zerstörungsfreie Prüfung von Stahlrohren - Teil 10:
Contrôle automatisé par ultrasons sur toute la
Automatisierte Ultraschallprüfung nahtloser und
circonférence des tubes en acier sans soudure et soudés geschweißter (ausgenommen unterpulvergeschweißter)
(sauf à l'arc immergé sous flux en poudre) pour la détection Stahlrohre über den gesamten Rohrumfang zum Nachweis
des imperfections longitudinales et/ou transversales (ISO von Unvollkommenheiten in Längs- und/oder Querrichtung
10893-10:2011) (ISO 10893-10:2011)
This European Standard was approved by CEN on 10 December 2010.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national
standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same
status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland,
Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2011 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN ISO 10893-10:2011: E
worldwide for CEN national Members.
Contents Page
Foreword .3
Foreword
This document (EN ISO 10893-10:2011) has been prepared by Technical Committee ISO/TC 17 "Steel" in
collaboration with Technical Committee ECISS/TC 110 “Steel tubes, and iron and steel fittings” the secretariat
of which is held by UNI.
This European Standard shall be given the status of a national standard, either by publication of an identical
text or by endorsement, at the latest by October 2011, and conflicting national standards shall be withdrawn at
the latest by October 2011.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights.
This document supersedes EN 10246-6:1999, EN 10246-7:2005.
According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following
countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech
Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain,
Sweden, Switzerland and the United Kingdom.
Endorsement notice
The text of ISO 10893-10:2011 has been approved by CEN as a EN ISO 10893-10:2011 without any
modification.
INTERNATIONAL ISO
STANDARD 10893-10
First edition
2011-04-01
Non-destructive testing of steel tubes —
Part 10:
Automated full peripheral ultrasonic
testing of seamless and welded (except
submerged arc-welded) steel tubes for
the detection of longitudinal and/or
transverse imperfections
Essais non destructifs des tubes en acier —
Partie 10: Contrôle automatisé par ultrasons sur toute la circonférence
des tubes en acier sans soudure et soudés (sauf à l'arc immergé sous
flux en poudre) pour la détection des imperfections longitudinales et/ou
transversales
Reference number
ISO 10893-10:2011(E)
©
ISO 2011
ISO 10893-10:2011(E)
PDF disclaimer
This PDF file may contain embedded typefaces. In accordance with Adobe's licensing policy, this file may be printed or viewed but
shall not be edited unless the typefaces which are embedded are licensed to and installed on the computer performing the editing. In
downloading this file, parties accept therein the responsibility of not infringing Adobe's licensing policy. The ISO Central Secretariat
accepts no liability in this area.
Adobe is a trademark of Adobe Systems Incorporated.
Details of the software products used to create this PDF file can be found in the General Info relative to the file; the PDF-creation
parameters were optimized for printing. Every care has been taken to ensure that the file is suitable for use by ISO member bodies. In
the unlikely event that a problem relating to it is found, please inform the Central Secretariat at the address given below.
© ISO 2011
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means,
electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or
ISO's member body in the country of the requester.
ISO copyright office
Case postale 56 • CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Published in Switzerland
ii © ISO 2011 – All rights reserved
ISO 10893-10:2011(E)
Contents Page
Foreword .iv
1 Scope.1
2 Normative references.1
3 Terms and definitions .2
4 General requirements .3
5 Test method .3
6 Reference tube.4
6.1 General .4
6.2 Types of reference notches.4
6.3 Dimensions of reference notches.5
7 Equipment calibration and checking.6
7.1 General .6
7.2 Adjustment of trigger/alarm level .6
7.3 Calibration check and recalibration .7
8 Acceptance .7
9 Test report.8
Annex A (normative) Testing on longitudinal imperfections of tubes with a ratio of the specified
outside diameter to the average of the specified thickness range less than 5 .9
Annex B (normative) Manual/semi-automated testing of untested ends and suspect areas .11
ISO 10893-10:2011(E)
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies
(ISO member bodies). The work of preparing International Standards is normally carried out through ISO
technical committees. Each member body interested in a subject for which a technical committee has been
established has the right to be represented on that committee. International organizations, governmental and
non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the
International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.
International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2.
The main task of technical committees is to prepare International Standards. Draft International Standards
adopted by the technical committees are circulated to the member bodies for voting. Publication as an
International Standard requires approval by at least 75 % of the member bodies casting a vote.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. ISO shall not be held responsible for identifying any or all such patent rights.
ISO 10893-10 was prepared by Technical Committee ISO/TC 17, Steel, Subcommittee SC 19, Technical
delivery conditions for steel tubes for pressure purposes.
This first edition cancels and replaces ISO 9303:1989 and ISO 9305:1989, which have been technically
revised.
ISO 10893 consists of the following parts, under the general title Non-destructive testing of steel tubes:
⎯ Part 1: Automated electromagnetic testing of seamless and welded (except submerged arc-welded) steel
tubes for the verification of hydraulic leaktightness
⎯ Part 2: Automated eddy current testing of seamless and welded (except submerged arc-welded) steel
tubes for the detection of imperfections
⎯ Part 3: Automated full peripheral flux leakage testing of seamless and welded (except submerged
arc-welded) ferromagnetic steel tubes for the detection of longitudinal and/or transverse imperfections
⎯ Part 4: Liquid penetrant inspection of seamless and welded steel tubes for the detection of surface
imperfections
⎯ Part 5: Magnetic particle inspection of seamless and welded ferromagnetic steel tubes for the detection of
surface imperfections
⎯ Part 6: Radiographic testing of the weld seam of welded steel tubes for the detection of imperfections
⎯ Part 7: Digital radiographic testing of the weld seam of welded steel tubes for the detection of
imperfections
⎯ Part 8: Automated ultrasonic testing of seamless and welded steel tubes for the detection of laminar
imperfections
⎯ Part 9: Automated ultrasonic testing for the detection of laminar imperfections in strip/plate used for the
manufacture of welded steel tubes
⎯ Part 10: Automated full peripheral ultrasonic testing of seamless and welded (except submerged
arc-welded) steel tubes for the detection of longitudinal and/or transverse imperfections
iv © ISO 2011 – All rights reserved
ISO 10893-10:2011(E)
⎯ Part 11: Automated ultrasonic testing of the weld seam of welded steel tubes for the detection of
longitudinal and/or transverse imperfections
⎯ Part 12: Automated full peripheral ultrasonic thickness testing of seamless and welded (except
submerged arc-welded) steel tubes
-----------------
...
Questions, Comments and Discussion