Vitrified clay pipe systems for drains and sewers - Part 5: Requirements for perforated pipes and fittings

This European Standard specifies requirements for perforated pipes and compatible fittings made from vitrified clay with or without sockets for use in land drains and drainage of waste tips. They are also used for percolation into the ground.
This standard specifies different strength classes and areas of perforations.
NOTE 1   The specifiers/purchasers can select perforated pipes and compatible fittings according to their requirements.
NOTE 2   Corresponding provisions for the evaluation of conformity (ITT and FPC) and sampling and those for the test methods are further specified in EN 295-2 and EN 295-3, respectively.

Steinzeugrohrsysteme für Abwasserleitungen und -kanäle - Teil 5: Anforderungen an gelochte Rohre und Formstücke

Diese Europäische Norm legt Anforderungen an gelochte Rohre und zugehörige Formstücke aus Stein¬zeug mit oder ohne Muffen zur Verwendung in Bodendränungen und Dränungen von Mülldeponien fest. Sie können auch für die Versickerung in den Untergrund verwendet werden.
Diese Norm enthält auch Anforderungen zu verschiedenen Festigkeitsklassen und Lochflächen.
ANMERKUNG 1   Die Auftraggeber/Käufer können diese entsprechend ihren Anforderungen wählen.
ANMERKUNG 2   Festlegungen zur Bewertung der Konformität und Probenahme (ITT und WPK) sowie Prüfverfahren sind in EN 295 2 bzw. in EN 295 3 festgelegt.

Systèmes de tuyaux en grès vitrifié pour les collecteurs d'assainissement et les branchements - Partie 5: Exigences applicables aux tuyaux perforés et raccords

La présente Norme européenne spécifie les exigences pour les tuyaux perforés et les raccords compatibles en grès vitrifié, avec ou sans collets, devant être utilisés dans des systèmes de drainage de terrains et de décharges. Ils sont également utilisés pour l’épandage dans le sol.
La présente Norme spécifie différentes classes de résistances et différentes surfaces perforées
NOTE 1   Les prescripteurs/acheteurs peuvent les sélectionner en fonction de leurs exigences.
NOTE 2   Des dispositions correspondantes pour l’évaluation de la conformité (essais de type initiaux [ETI] et contrôles de la production en usine [CPU]) et l’échantillonnage et les dispositions pour les méthodes d’essai sont spécifiées respectivement dans l’EN 295-2 et l’EN 295-3.

Keramični cevni sistemi za odvod odpadne vode in kanalizacijo - 5. del: Zahteve za drenažne cevi in fazonske kose

Ta evropski standard podaja zahteve za drenažne cevi in kompatibilne fazonske kose, ki so narejeni iz keramike, imajo ali nimajo obojk in se uporabljajo za izdelavo zemeljskih odvodov in drenaže odlagališč odpadkov. Uporabljajo se tudi za precejanje v zemljo. Ta standard določa različne razrede moči in območja precejanja.

General Information

Status
Published
Publication Date
05-Feb-2013
Current Stage
9093 - Decision to confirm - Review Enquiry
Completion Date
13-Jun-2024

Relations

Buy Standard

Standard
EN 295-5:2013
English language
17 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Steinzeugrohrsysteme für Abwasserleitungen und -kanäle - Teil 5: Anforderungen an gelochte Rohre und FormstückeSystèmes de tuyaux et accessoires en grès pour les réseaux de branchement et d’assainissement - Partie 5: Exigences pour tuyaux perforés et accessoiresVitrified clay pipe systems for drains and sewers - Part 5: Requirements for perforated pipes and fittings93.030Zunanji sistemi za odpadno vodoExternal sewage systems91.140.80Drenažni sistemiDrainage systems23.040.50Cevi in fitingi iz drugih materialovPipes and fittings of other materialsICS:Ta slovenski standard je istoveten z:EN 295-5:2013SIST EN 295-5:2013en,fr,de01-julij-2013SIST EN 295-5:2013SLOVENSKI
STANDARDSIST EN 295-5:1996/A1:2000SIST EN 295-5:1996SIST EN 295-10:20051DGRPHãþD

EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 295-5
February 2013 ICS 93.030 Supersedes EN 295-10:2005, EN 295-5:1994English Version
Vitrified clay pipe systems for drains and sewers - Part 5: Requirements for perforated pipes and fittings
Systèmes de tuyaux en grès vitrifié pour les collecteurs d'assainissement et les branchements - Partie 5: Exigences applicables aux tuyaux perforés et raccords
Steinzeugrohrsysteme für Abwasserleitungen und -kanäle -Teil 5: Anforderungen an gelochte Rohre und FormstückeThis European Standard was approved by CEN on 1 December 2012.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre:
Avenue Marnix 17,
B-1000 Brussels © 2013 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 295-5:2013: ESIST EN 295-5:2013

Relationship between this European Standard and the Essential Requirements of the EU Construction Products Directive . 11 ZA.1 Scope and relevant characteristics . 11 ZA.2 Procedures for the attestation of conformity of perforated vitrified clay pipes and fittings . 12 ZA.2.1 Systems of attestation of conformity . 12 ZA.2.2 EC declaration of conformity . 13 ZA.3 CE marking . 14 ZA.3.1 General . 14 ZA.3.2 CE marking on the product . 14 ZA.3.3 CE marking in the accompanying documents . 15 Bibliography. 17
Requirements for components of manholes and inspection chambers  Part 7: Requirements for pipes and joints for pipe jacking According to the CEN/CENELEC Internal Regulations, the national standards organisations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. SIST EN 295-5:2013

This standard specifies different strength classes and areas of perforations.
NOTE 1 The specifiers/purchasers can select them according to their requirements. NOTE 2 Corresponding provisions for the evaluation of conformity (ITT and FPC) and sampling and those for the test methods are further specified in EN 295-2 and EN 295-3, respectively. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 295-1:2013, Vitrified clay pipe systems for drains and sewers — Part 1: Requirements for pipes, fittings and joints EN 295-2:2013, Vitrified clay pipe systems for drains and sewers — Part 2: Evaluation of conformity and sampling EN 295-3:2012, Vitrified clay pipe systems for drains and sewers — Part 3: Test methods 3 Terms and definitions For the purposes of this document, the terms and definitions given in EN 295-1:2013 and the following apply. 3.1 area of perforations total area of holes or slots per metre length measured on the inside of the pipe 4 Requirements for pipes and fittings 4.1 Material, manufacture, water absorption and appearance For material, manufacture, water absorption and appearance, perforated pipes and fittings shall comply with EN 295-1:2013, 5.1.
4.2 Internal diameter The internal diameter shall not be less than the values according to Table 1. SIST EN 295-5:2013

Other nominal sizes can be manufactured to comply with this standard, providing that the minimum internal diameter shall be not less than 97,5 % of the nominal size, rounded to the nearest whole mm. 4.3 Length Preferred lengths of pipes and straight fittings are not specified in this standard.
The length shall be measured to the nearest whole millimetre. The tolerance on the declared nominal length of pipes and straight fittings shall be from – 2 % to + 5 %, or ± 10 mm, whichever is the larger. 4.4 Deviation from straightness When tested in accordance with EN 295-3:2012, Clause 6, the deviation from straightness of the barrel of a pipe shall not be greater than the values given in Table 2, measured to the nearest whole millimetre. Table 2 — Deviation from straightness
Nominal size DN Maximum deviation from straightness mm/m of nominal length < 150 6 ≥ 150 to ≤ 250 5 > 250 4
4.5 Angle of curvature and radius of bends The preferred nominal angles of curvature of bends are 15°; 22,5°; 30° and 45°. The tolerance on angle shall be ± 5° of the nominal value. The centreline radius shall not be less than the nominal size in millimetres. SIST EN 295-5:2013
...

Questions, Comments and Discussion