CEN/TS 54-32:2015
(Main)Fire detection and fire alarm systems - Part 32: Planning, design, installation, commissioning, use and maintenance of voice alarm systems
Fire detection and fire alarm systems - Part 32: Planning, design, installation, commissioning, use and maintenance of voice alarm systems
This Technical Specification provides guidelines for the planning, design, installation, commissioning, use, maintenance and modification of voice alarm systems in and around buildings that broadcast information for the protection of lives in a fire emergency. See EN 54 1:2011, Figure 1, item C and item M.
These guidelines cover voice alarm systems that are triggered automatically by a fire detection and fire alarm system or that are manually triggered, or both.
This Technical Specification does not apply to fire detection and fire alarm systems that only use voice sounders, bells or sounders or a combination of these.
NOTE 1 CEN/TS 54-14 provides guidelines for these systems.
This Technical Specification does not exclude the use of voice alarm systems for emergency purposes other than fire emergency.
NOTE 2 When used for emergencies other than those due to fire, it might be appropriate to modify the guidance in this Technical Specification.
This Technical Specification does not exclude the use of voice alarm systems for non-emergency purposes.
Brandmeldeanlagen - Teil 32: Projektierung, Montage, Inbetriebsetzung, Betrieb und Instandhaltung von Sprachalarmsystemen
Diese Technische Spezifikation stellt Richtlinien für die Planung, Projektierung, Montage, Inbetriebsetzung, Betrieb, Instandhaltung und Änderung von Sprachalarmanlagen (SAA)N1) innerhalb und außerhalb von Gebäuden zur Verfügung, welche Informationen zum Schutz von Leben im Brandfall übertragen. Siehe EN 54-1:2001, Bild 1, Funktionselement C und Funktionselement M.
Diese Richtlinien umfassen SAA, welche automatisch durch eine Brandmeldeanlage oder manuell oder durch beides ausgelöst werden.
Diese Technische Spezifikation gilt nicht für Brandmeldeanlagen, welche nur Sprachalarmgeber, Glocken oder Signalgeber oder eine Kombination dieser verwenden.
ANMERKUNG 1 Richtlinien für diese Anlagen werden in CEN/TS 54-14 zur Verfügung gestellt.
Diese Technische Spezifikation schließt den Betrieb von SAA für andere Alarmfälle als den Brandfall nicht aus.
ANMERKUNG 2 Sofern die Anlage für andere Alarmfälle als den Brandfall benutzt wird, kann eine Modifikation der Richtlinien dieser Technischen Spezifikation angemessen sein.
Diese Technische Spezifikation schließt den Betrieb von SAA für Zwecke, die nicht auf eine Alarmmeldung bezogen sind, nicht aus.
Systèmes de détection et d'alarme incendie - Partie 32 : Planification, conception, installation, mise en service, utilisation et maintenance des systèmes d'alarme vocale
Sistemi za odkrivanje in javljanje požara ter alarmiranje - 32. del: Načrtovanje, projektiranje, vgradnja, preverjanje, uporaba in vzdrževanje zvočnih sistemov za javljanje požara
Ta evropska tehnična specifikacija določa smernice za načrtovanje, projektiranje, vgradnjo, preverjanje, uporabo in vzdrževanje zvočnih sistemov za javljanje požara v zgradbah in okoli njih, ki oddajajo informacije za zaščito življenj v primeru požara. Glej EN 54 1:2011, slika 1, element C in element M.
Te smernice zajemajo zvočne sisteme za javljanje požara, ki jih samodejno sproži sistem za odkrivanje in javljanje požara ter alarmiranje, ki so sproženi ročno ali oboje.
Ta evropska tehnična specifikacija ne velja za sisteme za odkrivanje in javljanje požara ter alarmiranje, ki uporabljajo samo glasovne naprave, zvonce ali zvočne naprave ali njihovo kombinacijo.
OPOMBA 1 Smernice za te sisteme so navedene v standardu CEN/TS 54-14.
Ta evropska tehnična specifikacija ne zajema uporabe zvočnih sistemov za javljanje požara za druge nujne primere, razen v primeru požara.
OPOMBA 2 Če so uporabljene za druge nujne primere in ne za požar, je treba prilagoditi smernice v tej tehnični specifikaciji.
Ta evropska tehnična specifikacija ne zajema uporabe zvočnih sistemov za javljanje požara v primerih, ki niso nujni.
General Information
Standards Content (Sample)
SLOVENSKI STANDARD
01-september-2015
6LVWHPL]DRGNULYDQMHLQMDYOMDQMHSRåDUDWHUDODUPLUDQMHGHO1DþUWRYDQMH
SURMHNWLUDQMHYJUDGQMDSUHYHUMDQMHXSRUDEDLQY]GUåHYDQMH]YRþQLKVLVWHPRY]D
MDYOMDQMHSRåDUD
Fire detection and fire alarm systems - Part 32: Planning, design, installation,
commissioning, use and maintenance of voice alarm systems
Brandemeldanlagen - Teil 32: Projektierung, Montage, Inbetriebnahme, Betrieb und
Instandhaltung von Sprachalarmsystemen
Systèmes de détection et d'alarme incendie - Partie 32 : Planification, conception,
installation, mise en service, utilisation et maintenance des systèmes d'alarme vocale
Ta slovenski standard je istoveten z: CEN/TS 54-32:2015
ICS:
13.220.20 3RåDUQD]DãþLWD Fire protection
13.320 Alarmni in opozorilni sistemi Alarm and warning systems
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
TECHNICAL SPECIFICATION
CEN/TS 54-32
SPÉCIFICATION TECHNIQUE
TECHNISCHE SPEZIFIKATION
July 2015
ICS 13.220.20; 13.320
English Version
Fire detection and fire alarm systems - Part 32: Planning, design,
installation, commissioning, use and maintenance of voice alarm
systems
Systèmes de détection et d'alarme incendie - Partie 32 : Brandemeldanlagen - Teil 32: Projektierung, Montage,
Planification, conception, installation, mise en service, Inbetriebnahme, Betrieb und Instandhaltung von
utilisation et maintenance des systèmes d'alarme vocale Sprachalarmsystemen
This Technical Specification (CEN/TS) was approved by CEN on 14 March 2015 for provisional application.
The period of validity of this CEN/TS is limited initially to three years. After two years the members of CEN will be requested to submit their
comments, particularly on the question whether the CEN/TS can be converted into a European Standard.
CEN members are required to announce the existence of this CEN/TS in the same way as for an EN and to make the CEN/TS available
promptly at national level in an appropriate form. It is permissible to keep conflicting national standards in force (in parallel to the CEN/TS)
until the final decision about the possible conversion of the CEN/TS into an EN is reached.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania,
Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United
Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2015 CEN All rights of exploitation in any form and by any means reserved Ref. No. CEN/TS 54-32:2015 E
worldwide for CEN national Members.
Contents Page
Foreword . 5
Introduction . 6
1 Scope . 7
2 Normative references . 7
3 Terms and definitions, symbols and abbreviations . 7
3.1 Terms and definitions. 7
3.2 Symbols and abbreviations . 14
4 General . 14
4.1 Use of this Technical Specification . 14
4.2 Guideline format . 14
4.3 Project phases . 15
4.4 Safety requirements . 16
4.5 Warranties and guarantees . 16
4.6 Documentation . 16
4.7 Responsibility . 16
4.8 Qualifications . 16
5 Concept (Assessment of needs) . 17
5.1 Responsibility . 17
5.2 Intention and purpose . 17
5.3 Risk-assessment . 17
5.4 Consultation . 18
5.5 Local, regional or national requirements . 19
5.6 Documentation . 19
5.7 Parts of the building needing cover . 21
5.8 Extent of manual control . 22
6 Planning and design . 22
6.1 Responsibility of the designer . 22
6.2 Devices connected to the VAS . 22
6.3 Faults. 22
6.4 Modes and conditions of operation . 23
6.5 Intelligibility . 25
6.6 Special risks . 29
6.7 VAS control and indicating equipment (VACIE) . 30
6.8 Interface between the fire detection and alarm system and the VAS . 30
6.9 Initiation of the voice alarm condition . 31
6.10 Power supply . 31
6.11 Standby power supply. 32
6.12 Power amplifiers . 33
6.13 Loudspeakers . 33
6.14 Hierarchical VAS . 35
6.15 Distributed VAS . 36
7 Installation . 37
7.1 General . 37
7.2 Responsibility of the installer . 37
7.3 Location of equipment . 37
7.4 Installation of the VACIE . 37
7.5 Cable installation . 38
7.6 Inspection and testing of wiring . 40
7.7 Loudspeaker installation . 41
7.8 Inspection and testing of loudspeaker circuits . 41
7.9 Documentation. 41
8 Commissioning . 41
8.1 General . 41
8.2 Responsibility . 42
8.3 Prerequisite documentation . 42
8.4 Commissioning . 42
8.5 Documentation. 45
8.6 Operator instructions . 45
9 Verification . 46
9.1 General . 46
9.2 Responsibility . 46
9.3 Documentation. 47
10 Third-party approval . 47
10.1 General . 47
10.2 Approval by authorities having jurisdiction and others . 47
10.3 Approval procedures . 47
10.4 Periodic inspection by an approval body . 48
11 Acceptance . 48
12 Use . 49
12.1 Responsibility . 49
12.2 Periodic tests . 50
12.3 Repair . 51
12.4 Logbook . 51
13 Maintenance . 51
13.1 General . 51
13.2 Responsibility .
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.