EN 13162:2012
(Main)Thermal insulation products for buildings - Factory made mineral wool (MW) products - Specification
Thermal insulation products for buildings - Factory made mineral wool (MW) products - Specification
This European Standard specifies the requirements for factory made mineral wool products, with or without facings or coatings, which are used for the thermal insulation of buildings. The products are manufactured in the mat blankets, boards or slabs.
Products covered by this standard are also used in prefabricated thermal insulation systems and composite panels; the performance of systems incorporating these products is not covered.
This standard describes product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling.
This standard does not specify the required level of a given property to be achieved by a product to demonstrate fitness for purpose in a particular application. The levels required for a given application are to be found in regulations or non-conflicting standards.
Products with a declared thermal resistance lower than 0,25 m2K/W or a declared thermal conductivity greater than 0,060 W/(mK) at 10 °C are not covered by this standard.
This standard does not cover in situ insulation products (covered by EN 14064 parts 1 and 2) and products intended to be used for the insulation of building equipment and industrial installations (covered by EN 14303).
Wärmedämmstoffe für Gebäude - Werkmäßig hergestellte Produkte aus Mineralwolle (MW) - Spezifikation
Diese Europäische Norm legt die Anforderungen an werkmäßig hergestellte Produkte aus Mineralwolle mit
oder ohne Kaschierung oder Beschichtung fest, die für die Wärmedämmung von Gebäuden benutzt werden.
Die Produkte werden in Form von Matten oder Platten hergestellt.
Die in dieser Norm beschriebenen Produkte werden auch in vorgefertigten Wärmedämmsystemen und
Mehrschicht-Platten angewendet. Die Eigenschaften von Systemen, in die diese Produkte integriert sind,
werden nicht behandelt.
Die vorliegende Norm beschreibt die Produkteigenschaften und enthält die Prüfverfahren und Festlegungen
für die Konformitätsbewertung, die Kennzeichnung und die Etikettierung.
Diese Norm legt keine Leistungsstufen für eine vorgegebene Eigenschaft fest, die ein Produkt erreichen
muss, um für einen bestimmten Anwendungsfall tauglich zu sein. Die für bestimmte Anwendungen benötigten
Stufen können Regelwerken oder nicht entgegenstehenden Normen entnommen werden.
Diese Norm gilt nicht für Produkte, deren Nennwert des Wärmedurchlasswiderstandes niedriger als
0,25 m2⋅K/W oder deren Nennwert der Wärmeleitfähigkeit größer als 0,060 W/(m⋅K) bei 10 °C ist.
Die vorliegende Norm gilt weder für in situ-Dämmprodukte (durch EN 14064-1 und EN 14064-2 abgedeckt)
noch für Produkte, die zur Dämmung von haustechnischen und betriebstechnischen Anlagen (durch
EN 14303 abgedeckt) vorgesehen sind.
Produits isolants thermiques pour le bâtiment - Produits manufacturés en laine minérale (MW) - Spécification
La présente Norme européenne spécifie les exigences auxquelles doivent satisfaire les produits manufacturés en laine minérale, avec ou sans parements ou enduits de finition, utilisés pour l'isolation thermique des bâtiments. Les produits sont fabriqués sous forme de feutres, panneaux ou plaques.
Les produits couverts par la présente norme sont également utilisés dans des systèmes d'isolation thermique et dans des panneaux composites préfabriqués ; les performances des systèmes incorporant ces produits ne sont pas définies.
La présente norme décrit les caractéristiques des produits et contient des modes opératoires d'essai, d'évaluation de la conformité, de marquage et d'étiquetage.
La présente norme ne spécifie pas, pour une propriété donnée, le niveau exigé que doit atteindre un produit pour démontrer son aptitude à l'emploi dans une application particulière. Les niveaux requis pour une application donnée figurent dans les réglementations ou les normes non conflictuelles.
Les produits dont la résistance thermique déclarée à une température de 10 °C est inférieure à 0,25 m2×K/W ou dont la conductivité thermique déclarée à une température de 10 °C est supérieure à 0,060 W/(m×K) ne relèvent pas du domaine d'application de la présente norme.
Les produits isolants mis en oeuvre in situ (couverts par les parties 1 et 2 de l’EN 14604) et les produits destinés à être utilisés pour l'isolation des équipements du bâtiment et des installations industrielles (couverts par l’EN 14303) ne relèvent pas du domaine d'application de la présente norme.
Toplotnoizolacijski proizvodi za stavbe - Proizvodi iz mineralne volne (MW) - Specifikacija
Ta evropski standard določa zahteve za površinsko obdelane ali lakirane ali površinsko neobdelane ali nelakirane proizvode iz mineralne volne, ki se uporabljajo za toplotno izolacijo stavb. Proizvodi so izdelani v obliki kolutov, plošč ali blokov. Proizvodi iz tega standarda se uporabljajo tudi v predizdelanih sistemih toplotne izolacije in vezanih ploščah; lastnosti sistemov iz teh proizvodov niso opisane. Ta standard opisuje lastnosti proizvodov ter zajema postopke za preskušanje, vrednotenje skladnosti, označevanje in etiketiranje. Ta standard ne določa zahtevane ravni določene lastnosti, ki jo mora proizvod doseči, da se dokaže njegova primernost namenu za posamezno vrsto uporabe. Zahtevane ravni za posamezno uporabo so določene v uredbah ali standardih, ki niso v nasprotju s tem standardom. Proizvodi z deklarirano toplotno upornostjo, nižjo od 0,25 m2 K/W, ali deklarirano toplotno prevodnostjo, višjo od 0,060 W/mK pri 10 °C, v tem standardu niso zajeti. Ta standard ne zajema toplotnoizolacijskih proizvodov, izdelanih na kraju samem (zajema jih standard EN 14064, dela 1 in 2), ter proizvodov, namenjenih za izolacijo gradbene opreme in industrijskih napeljav (zajema jih standard EN 14303).
General Information
Relations
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Toplotnoizolacijski proizvodi za stavbe - Proizvodi iz mineralne volne (MW) - SpecifikacijaWärmedämmstoffe für Gebäude - Werkmäßig hergestellte Produkte aus Mineralwolle (MW) - SpezifikationProduits isolants thermiques pour le bâtiment - Produits manufacturés en laine minérale (MW) - SpécificationThermal insulation products for buildings - Factory made mineral wool (MW) products - Specification91.100.60Thermal and sound insulating materialsICS:Ta slovenski standard je istoveten z:EN 13162:2012SIST EN 13162:2013en,fr,de01-marec-2013SIST EN 13162:2013SLOVENSKI
STANDARDSIST EN 13162:20091DGRPHãþD
EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 13162
November 2012 ICS 91.100.60 Supersedes EN 13162:2008English Version
Thermal insulation products for buildings - Factory made mineral wool (MW) products - Specification
Produits isolants thermiques pour le bâtiment - Produits manufacturés en laine minérale (MW) - Spécification
Wärmedämmstoffe für Gebäude - Werkmäßig hergestellte Produkte aus Mineralwolle (MW) - Spezifikation This European Standard was approved by CEN on 6 October 2012.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre:
Avenue Marnix 17,
B-1000 Brussels © 2012 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 13162:2012: ESIST EN 13162:2013
Determination of the declared values of thermal resistance and
thermal conductivity . 23Annex B (normative)
Initial type testing (ITT) and factory production control (FPC) . 25Annex C (normative)
MW multi-layered insulation products . 29Annex D (informative)
Examples for the determination of the declared values of thermal resistance and thermal conductivity for a product or a product group . 31Annex ZA (informative)
Clauses of this European Standard addressing the provisions of the EU Construction Products Directive. 34Bibliography . 42 Tables Table 1 — Level and classes for thickness tolerances . 11Table 2 — Dimensional stability under specified temperature and humidity conditions . 13Table 3 — Classes for thickness tolerances . 15Table 4 — Levels for compressibility . 15Table 5 — Test methods, test specimens and conditions . 18Table A.1 — Values for k for one sided 90 % tolerance interval with a confidence level of 90 % . 24Table B.1 — Minimum number of tests for ITT and minimum product testing frequencies . 25Table B.2 — Minimum product testing frequencies for the reaction to fire characteristics . 27Table D.1 — λ test results . 31Table D.2 — R test results . 32Table ZA.1 — Relevant clauses for Mineral wool and intended use . 35Table ZA.2 — Systems of attestation of conformity . 36Table ZA.3.1 — Assignment of evaluation of conformity tasks for products under system 1 . 37Table ZA.3.2 — Assignment of evaluation of conformity tasks for products under system 3 or system 3 combined with system 4 for reaction to fire . 38 Figures Figure ZA.1 — Example CE marking information . 41 SIST EN 13162:2013
Compared with EN 13162:2008, the main changes are: a) better harmonisation between the individual standards of the package (EN 13162 to EN 13171) on definitions, requirements, classes and levels; b) new normative annex on multi-layered products; c) changes of some editorial and technical content and addition of information on some specific items such as for MW: lamella, compressibility…; d) addition to links to EN 15715, Thermal insulation products — Instructions for mounting and fixing for reaction to fire testing — Factory made products; e) changes to Annex ZA. This standard is one of a series of standards for thermal insulation products used in buildings but this standard may be used in other areas where appropriate. In pursuance of Resolution BT 20/1993 revised, CEN/TC 88 have proposed defining the standards listed below as a package of documents. The package of standards comprises the following group of interrelated standards for the specifications of factory made thermal insulation products, all of which come within the scope of CEN/TC 88: EN 13162, Thermal insulation products for buildings — Factory made mineral wool (MW) products —Specification EN 13163, Thermal insulation products for buildings — Factory made expanded polystyrene (EPS) products — Specification EN 13164, Thermal insulation products for buildings — Factory made extruded polystyrene foam (XPS) products — Specification EN 13165, Thermal insulation products for buildings — Factory made rigid polyurethane foam (PU) products — Specification SIST EN 13162:2013
1 Scope This European Standard specifies the requirements for factory made mineral wool products, with or without facings or coatings, which are used for the thermal insulation of buildings. The products are manufactured in the mat blankets, boards or slabs. Products covered by this standard are also used in prefabricated thermal insulation systems and composite panels; the performance of systems incorporating these products is not covered. This standard describes product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling. This standard does not specify the required level of a given property to be achieved by a product to demonstrate fitness for purpose in a particular application. The levels required for a given application are to be found in regulations or non-conflicting standards. Products with a declared thermal resistance lower than 0,25 m2⋅K/W or a declared thermal conductivity greater than 0,060 W/(m⋅K) at 10 °C are not covered by this standard.
This standard does not cover in situ insulation products (covered by EN 14064 parts 1 and 2) and products intended to be used for the insulation of building equipment and industrial installations (covered by EN 14303). 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 822, Thermal insulating products for building applications — Determination of length and width EN 823, Thermal insulating products for building applications — Determination of thickness EN 824, Thermal insulating products for building applications — Determination of squareness EN 825, Thermal insulating products for building applications — Determination of flatness EN 826, Thermal insulating products for building applications — Determination of compression behaviour EN 1604, Thermal insulating products for building applications — Determination of dimensional stability under specified temperature and humidity conditions EN 1606, Thermal insulating products for building applications — Determination of compressive creep EN 1607, Thermal insulating products for building applications — Determination of tensile strength perpendicular to faces EN 1609, Thermal insulating products for building applications — Determination of short term water absorption by partial immersion EN 12086:1997, Thermal insulating products for building applications — Determination of water vapour transmission properties EN 12087, Thermal insulating products for building applications — Determination of long-term water absorption by immersion SIST EN 13162:2013
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.