Sanitary tapware - Electronic opening and closing sanitary tapware

The purpose of this document is to define requirements for marking, identification, leaktightness, electrical and operational safety and mechanical resistance for sanitary tapware with opening and closing controlled electronically.
The conditions of use for the supply system type are specified in Table 2:
[Table 2]
Annex B lists possible consequences of using a product outside its recommended operating range.
[Figure 1]
[Figure 2]
A vented domestic hot water and cold water supply system incorporating gravity hot water, mains cold water and alternative gravity cold water supply to sanitary appliances.

Sanitärarmaturen - Sanitärarmaturen mit elektronischer Öffnungs- und Schließfunktion

Dieses Dokument legt die Anforderungen an die Kennzeichnung, Identifizierung, Dichtheit, elektrische Sicherheit, Betriebssicherheit und mechanische Festigkeit von Sanitärarmaturen mit elektronisch geregelter Öffnungs- und Schließfunktion fest.
Die Einsatzbedingungen für die Wasserversorgungssysteme sind in Tabelle 2 festgelegt:
[Tabelle 2]
Anhang B führt mögliche Auswirkungen für den Fall auf, dass ein Produkt außerhalb seines empfohlenen Betriebsbereiches verwendet wird.
[Bild 1]
[Bild 2]
Belüftetes Warm- und Kaltwasserversorgungssystem für den häuslichen Gebrauch, einschließlich Warmwasser durch Schwerkraftbetrieb, kaltes Leitungswasser und wahlweise Kaltwasseranschluss an sanitäre Anlagen im Schwerkraftbetrieb.

Robinetterie sanitaire - Robinet sanitaire à ouverture et fermeture électroniques

L’objectif du présent document est de définir les exigences de marquage, d’identification, d’étanchéité, de sécurité électrique et de fonctionnement et de résistance mécanique pour la robinetterie sanitaire à ouverture et fermeture électroniques.
Les conditions d’utilisation relatives au type de système d’alimentation sont spécifiées dans le Tableau 2.
[Tableau 2]
L’Annexe B indique les conséquences possibles en cas d’utilisation d’un produit en dehors du domaine de fonctionnement recommandé.
[Figure 1]
[Figure 2]
Système d’alimentation en eau chaude et froide domestique, relié à l’air libre, comportant de l’eau chaude gravitaire, de l’eau froide de distribution et de l’eau froide gravitaire pour les appareils sanitaires.

Sanitarne armature - Elektronsko odpiranje in zapiranje sanitarnih armatur

General Information

Status
Not Published
Publication Date
22-May-2024
Current Stage
4599 - Dispatch of FV draft to CMC - Finalization for Vote
Start Date
10-Aug-2023
Due Date
25-Aug-2022
Completion Date
10-Aug-2023

Relations

Buy Standard

Draft
prEN 15091:2022
English language
51 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
oSIST prEN 15091:2022
01-maj-2022
Sanitarne armature - Elektronsko odpiranje in zapiranje sanitarnih armatur
Sanitary tapware - Electronic opening and closing sanitary tapware
Sanitärarmaturen - Sanitärarmaturen mit elektronischer Öffnungs- und Schließfunktion
Robinetterie sanitaire - Robinet sanitaire à ouverture et fermeture électroniques
Ta slovenski standard je istoveten z: prEN 15091
ICS:
91.140.70 Sanitarne naprave Sanitary installations
oSIST prEN 15091:2022 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------
oSIST prEN 15091:2022

---------------------- Page: 2 ----------------------
oSIST prEN 15091:2022


DRAFT
EUROPEAN STANDARD
prEN 15091
NORME EUROPÉENNE

EUROPÄISCHE NORM

March 2022
ICS 91.140.70 Will supersede EN 15091:2013
English Version

Sanitary tapware - Electronic opening and closing sanitary
tapware
Robinetterie sanitaire - Robinet sanitaire à ouverture Sanitärarmaturen - Sanitärarmaturen mit
et fermeture électroniques elektronischer Öffnungs- und Schließfunktion
This draft European Standard is submitted to CEN members for enquiry. It has been drawn up by the Technical Committee
CEN/TC 164.

If this draft becomes a European Standard, CEN members are bound to comply with the CEN/CENELEC Internal Regulations
which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.

This draft European Standard was established by CEN in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC
Management Centre has the same status as the official versions.

CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway,
Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and
United Kingdom.

Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are
aware and to provide supporting documentation.

Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without
notice and shall not be referred to as a European Standard.


EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION

EUROPÄISCHES KOMITEE FÜR NORMUNG

CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2022 CEN All rights of exploitation in any form and by any means reserved Ref. No. prEN 15091:2022 E
worldwide for CEN national Members.

---------------------- Page: 3 ----------------------
oSIST prEN 15091:2022
prEN 15091:2022 (E)
Contents Page
European foreword . 5
Introduction . 6
1 Scope . 7
2 Normative references . 9
3 Terms and definitions . 10
4 General requirements and testing . 11
4.1 General. 11
4.2 Identification . 11
4.3 Materials . 11
4.3.1 Chemical and hygienic requirements . 11
4.3.2 Exposed surface conditions . 11
4.4 Functions . 11
4.5 Backflow protection . 12
4.6 Electric characteristics and requirements . 12
4.6.1 General. 12
4.6.2 Electrical safety . 12
4.6.3 Electrical operation of solenoid valves . 12
4.6.4 Electric strength and insulation resistance of the solenoid valve . 13
4.6.5 Operational safety . 13
4.7 Leaktightness characteristics . 14
4.7.1 General. 14
4.7.2 Principle . 14
4.7.3 Apparatus . 14
4.7.4 Leaktightness of tapware upstream of the obturator . 14
4.7.5 Leaktightness of tapware downstream of the obturator with the obturator open . 14
4.7.6 Leaktightness tests - Summary table . 15
4.8 Pressure resistance characteristics - mechanical performance under pressure . 15
4.8.1 General. 15
4.8.2 Principle . 15
4.8.3 Apparatus . 15
4.8.4 Procedure . 15
4.8.5 Requirements . 15
5 Requirements and testing for tapware . 15
5.1 Scope . 15
5.2 Dimensional characteristics . 16
5.2.1 General. 16
5.2.2 Tap with visible body for horizontal surfaces . 16
5.2.3 Taps with visible body for mounting on vertical surfaces . 17
5.2.4 In-line tapware with threaded inlet and outlet . 18
5.2.5 Concealed tapware for vertical surfaces . 19
5.2.6 Mixing valves for horizontal surface . 19
5.2.7 Mixing valves with visible body for mounting on vertical surfaces with captive nuts
and eccentric unions . 20
5.2.8 Mixing valves with opposed inlets . 20
5.2.9 Nozzle outlets for use with aerators with integrated flow regulators . 22
2

---------------------- Page: 4 ----------------------
oSIST prEN 15091:2022
prEN 15091:2022 (E)
5.2.10 Special cases . 22
5.3 Hydraulic characteristics . 22
5.3.1 General . 22
5.3.2 Test apparatus for tapware intended for Type 1 water supply systems . 22
5.3.3 Principle of the flow test . 26
5.3.4 Requirements . 27
5.3.5 Cross flow between hot and cold water . 27
5.4 Water hammer . 27
5.4.1 Principle of water hammer test . 27
5.4.2 Test apparatus . 28
5.4.3 Procedure . 28
5.4.4 Requirements . 29
5.5 Endurance . 29
5.5.1 General . 29
5.5.2 Principle . 29
5.5.3 Procedure for single taps . 29
5.5.4 Procedure for mixers . 29
5.5.5 Requirements . 30
5.6 Acoustic characteristics . 30
5.6.1 General . 30
5.6.2 Procedure . 30
5.6.3 Requirements . 31
6 Requirements and testing for flushing valves for urinals . 32
6.1 Scope . 32
6.2 Definitions . 32
6.2.1 Single flush urinal valves . 32
6.2.2 Siphon action flushing urinal valves . 32
6.2.3 Isolating valves for flushing urinal valves . 32
6.3 Classification of flushing urinal valves . 32
6.4 Designation . 32
6.5 Dimensional characteristics . 33
6.6 Hydraulic characteristics . 34
6.6.1 General . 34
6.6.2 Test method . 34
6.7 Measurement of water hammer for urinal flushing valves . 35
6.7.1 Principle of water hammer test . 35
6.7.2 Test apparatus . 35
6.7.3 Procedure . 35
6.7.4 Requirements . 36
6.8 Mechanical endurance . 36
6.8.1 General . 36
6.8.2 Apparatus . 36
6.8.3 Procedure . 36
6.8.4 Requirements . 37
7 Requirements and testing for flushing valves for WCs . 37
7.1 Scope . 37
7.2 Definitions . 37
7.3 Classification . 38
7.3.1 General . 38
7.3.2 4 litre valve . 38
7.3.3 6 litre valve . 38
7.3.4 9 litre valve . 38
3

---------------------- Page: 5 ----------------------
oSIST prEN 15091:2022
prEN 15091:2022 (E)
7.4 Dimensional characteristics . 38
7.5 Hydraulic characteristics . 39
7.5.1 General. 39
7.5.2 Test method . 39
7.5.3 Testing of the flow rate / Impact force at lower dynamic pressure . 43
7.5.4 Testing of the flow rate/Volume at lower dynamic pressure . 44
7.5.5 Testing of flush flow rate / impact force at upper dynamic pressure . 45
7.5.6 Measurement of water hammer . 46
7.6 Principle and verification of atmospheric pipe interrupters of WC flushing valves . 47
7.7 Mechanical endurance . 47
7.7.1 General. 47
7.7.2 Procedure . 47
7.7.3 Minimum requirements . 47
7.8 Acoustic characteristics . 47
Annex A (normative) Design of pressure take-off tees. 48
Annex B (informative) Potential consequences of use outside the recommended operating
limits . 50
Bibliography . 51

4

---------------------- Page: 6 ----------------------
oSIST prEN 15091:2022
prEN 15091:2022 (E)
European foreword
This document (prEN 15091:2022) has been prepared by Technical Committee CEN/TC 164 “Water
Supply”, the secretariat of which is held by AFNOR.
This document is currently submitted to the CEN Enquiry.
This document will supersede EN 15091:2013.
In comparison with the previous edition, the following technical modifications have been made:
— XXXX;
— XXXX;
— XXXX.
5

---------------------- Page: 7 ----------------------
oSIST prEN 15091:2022
prEN 15091:2022 (E)
Introduction
This document is relevant for electrically operated (opening and closing) sanitary tapware used with
sanitary appliances, with a maximum voltage of 42 V AC / 72 V DC, in the enclosure of the tap.
Such tapware can be operated by any electrical source e.g. mains with a transformer, battery, etc.
Flow and temperature regulation devices installed either upstream or downstream of the tapware are
not covered by this specification.
The purpose of this document is to define requirements for the:
a) marking, identification, leak-tightness, electrical and operational safety, mechanical performance
and limitation of water hammer for electrical opening and closing tapware;
b) dimensional, hydraulic, endurance and acoustic characteristics;
c) procedure of tests in order to verify these characteristics.
As for possible unfavourable effects of the product to which this document applies, on the quality of water
intended for human consumption:
d) no information is provided by this document on possible use restrictions of the product in any of the
member states of the EU or EFTA;
e) it should be noted that, while awaiting the adoption of verifiable European criteria, existing national
regulations concerning the use and/or characteristics of this product remain in force.
Requirements for different products are defined in different clauses of this document as illustrated in
Table 1.
Table 1 — Identification of the clauses of this document

Clause 4. General
requirements and X X X X X
testing
Clause 5. Requirements X X X
     X X
and testing for tapware
Clause 6. Requirements X X
and testing for flushing      X X
valves for urinals
Clause 7. Requirements X X X
and testing for flushing      X  X
valves for WCs
6
MARKING
DIMENSIONAL
CHARACTERISTICS
ENDURANCE
ACOUSTIC
ELECTRICAL
SAFETY
OPERATIONAL
SAFETY
LEAKTIGHTNESS
MECHANICAL
RESISTANCE
HYDRAULIC
CHARACTERISTICS
WATER HAMMER
WATER HAMMER
FOLLOWING
PRODUCT

---------------------- Page: 8 ----------------------
oSIST prEN 15091:2022
prEN 15091:2022 (E)
1 Scope
The purpose of this document is to define requirements for marking, identification, leaktightness,
electrical and operational safety and mechanical resistance for sanitary tapware with opening and closing
controlled electronically.
The conditions of use for the supply system type are specified in Table 2:
Table 2 — Conditions of use
Recommended limits of
Limits of use
operation
Tapware with Tapware Tapware with
Water supply
normally open with normally open Tapware with

system
or normally latching or normally latching
closed (bistable) closed (bistable)
(monostable) solenoid (monostable) solenoid valves
solenoid valves valves solenoid valves
Minimum
0,05 MPa 0,05 MPa (0,1 to 0,5) MPa (0,1 to 0,5) MPa
dynamic
(0,5 bar) (0,5 bar) [(1 to 5) bar] [(1 to 5) bar]
pressure
Type 1
(see Figure 1)
Maximum
1 MPa
static 1 MPa (10 bar) 1 MPa (10 bar) 0,8 MPa (8 bar)
(10 bar)
pressure
Minimum (0,01 to
0,01 MPa 0,01 MPa (0,01 to 0,2) MPa
dynamic 0,2) MPa [(0,1
(0,1 bar) (0,1 bar) [(0,1 to 2) bar]
pressure to 2) bar]
a
Type 2
(see Figure 2)
Maximum 1 MPa (10 bar) 1 MPa
static (10 bar) 1 MPa (1 bar) 0,8 MPa (0,8 bar)
pressure
Temperature of the water ≤ 75 °C ≤ 75 °C ≤ 65 °C ≤ 65 °C
a
For Type 2, the manufacturer is expected to declare the minimum operating pressure at which opening, closing
and the specified flow rate can be obtained.
There is usually no acoustic classification for tapware used in supply systems of Type 2 and no specifications
governing the level of noise emissions from these water installations. If supply pressures are such that excessive
noise is generated it is advised that pressure or flow regulators are fitted in the system. Or where practicable,
tapware conforming to the appropriate acoustic classification are used.
Annex B lists possible consequences of using a product outside its recommended operating range.
7

---------------------- Page: 9 ----------------------
oSIST prEN 15091:2022
prEN 15091:2022 (E)

Key
1 cold water 3 mains supply pipe (Supply pressures from (0,05 to 1,0) MPa [(0,5 to 10) bar]
2 hot water 4 water heater
Figure 1 — Type 1 — Supply system with a pressure range of (0,05 to 1,0) MPa [(0,5 to 10) bar]
8

---------------------- Page: 10 ----------------------
oSIST prEN 15091:2022
prEN 15091:2022 (E)

Key
1 cold water storage cistern (cover omitted for clarity)
2 warning pipe
3 vent pipe
4 hot water cylinder
5 alternative cistern fed cold supply to sanitary appliances
6 to boiler
7 mains supply pipe (Supply pressures up to 8 bar)
Figure 2 — Type 2 — Supply system with a pressure range of (0,01 to 0,8) MPa [(0,1 to 8) bar]
A vented domestic hot water and cold water supply system incorporating gravity hot water, mains cold
water and alternative gravity cold water supply to sanitary appliances.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments) applies.
EN 31, Wash basins — Connecting dimensions
EN 35, Pedestal and wall-hung bidets with over-rim supply - Connecting dimensions
9

---------------------- Page: 11 ----------------------
oSIST prEN 15091:2022
prEN 15091:2022 (E)
EN 246, Sanitary tapware - General specifications for aerators
EN 248, Sanitary tapware - General specification for electrodeposited coatings of Ni-Cr
EN 695, Kitchen sinks - Connecting dimensions
EN 1717, Protection against pollution of potable water in water installations and general requirements of
devices to prevent pollution by backflow
EN 997, WC pans and WC suites with integral trap
EN 12541:2002, Sanitary tapware — Pressure flushing valves and automatic closing urinal valves PN 10
EN 13407, Wall-hung urinals — Functional requirements and test methods
EN 13618, Flexible hose assemblies in drinking water installations - Functional requirements and test
methods
EN 13959, Anti-pollution check valves - DN 6 to DN 250 inclusive family E, type A, B, C and D
EN 60335-1, Household and similar electrical appliances — Safety — Part 1: General requirements
(IEC 60335-1)
EN 60529, Degrees of protection provided by enclosures (IP Code)
EN 60730-2-8, Automatic electrical controls for household and similar use - Part 2-8: Particular
requirements for electrically operated water valves, including mechanical requirements (IEC 60730-2-8)
EN 61000-6-1, Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity for
residential, commercial and light-industrial environments (IEC 61000-6-1)
EN 61000-6-3, Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for
residential, commercial and light-industrial environments (IEC 61000-6-3)
EN ISO 228-1, Pipe threads where pressure-tight joints are not made on the threads - Part 1: Dimensions,
tolerances and designation (ISO 228-1)
EN ISO 3822 (all parts), Acoustics — Laboratory tests on noise emission from appliances and equipment
used in water supply installations (ISO 3822 series)
EN ISO 5167-1, Measurement of fluid flow by means of pressure differential devices inserted in circular
cross-section conduits running full - Part 1: General principles and requirements (ISO 5167-1)
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
ISO and IEC maintain terminological databases for use in standardization at the following addresses:
— ISO Online browsing platform: available at https://www.iso.org/obp
— IEC Electropedia: available at https://www.electropedia.org/
10

---------------------- Page: 12 ----------------------
oSIST prEN 15091:2022
prEN 15091:2022 (E)
3.1
cold water
water with a temperature less than 25 °C
3.2
hot water
water with a temperature between 52 °C and 75 °C
3.3
valve
electrically operated obturator for controlling the flow of water
3.4
normally open or normally closed (monostable) valve
obturation system continuously fed electrically while operated
3.5
latching (bistable) valve
obturation system electrically fed only for operating opening and closing
4 General requirements and testing
4.1 General
Tapware complying with this document shall be permanently and indelibly marked on the body with the
manufacturer's name or identification mark, volume class for urinals (e.g. class 4 or class 6) and if
applicable, the acoustic group and flow rate class.
4.2 Identification
a) The temperature control device for mixing taps shall be identified either by means of a scale and/or
symbols and/or by colours (Cold water – blue and Hot water – red).
b) The direction of operation of the temperature control device of mixers shall be identified.
c) For taps with separate control devices, the cold water shall be on the r
...

Questions, Comments and Discussion