Sanitary tapware - Measurement of functional performance of taps and showers

This document acknowledges the field of application for taps, shower outlets, shower sets and shower systems used in water supply systems with a pressure range of (0,05 to 1,0) MPa [(0,5 to 10) bar].
The tests described in this document are type tests (laboratory tests) and not quality control tests carried out during manufacture.
This document covers:
—   PN10 taps;
—   PN5 shower outlets;
—   PN5 shower sets;
—   PN10 shower systems.
The following products are excluded from this document:
—   shower taps on its own;
—   taps for filling bathtubs;
—   the tub filling function of combined taps;
—   the function of a tap that delivers e.g. boiling water or sparkling water, etc.;
—   body or side jet showers.
The conditions of use for taps and shower systems are given in Table 1. The conditions of use for showers sets and shower outlets are given in Table 2.
Table 1 — Conditions of use for taps and shower systems
Water supply system   Operating range of taps and shower systems
   Limits   Recommended
see Figure 1   dynamic pressure
≥ 0,05 MPa
(0,5 bar)
static pressure
≤ 1,0 MPa
(10,0 bar)   dynamic pressure b
(0,1 to 0,5) MPa
[(1,0 to 5,0) bar]
temperature   ≤ 70 °C a   ≤ 65 °C
a   This maximum temperature limit can only be reached for short durations not greater than 1 h.
b   Measured at the point of discharge.
NOTE   Taps and shower systems for use at pressures lower than those in Table 1 are not covered by this standard.
Table 2 — Conditions of use for shower outlets and shower sets
Water supply system   Operating range of showers
   Limits   Recommended
see Figure 1   dynamic pressure
≥ 0,05 MPa
(0,5 bar)
static pressure
≤ 0,5 MPa
(5,0 bar)   dynamic pressure
(0,1 to 0,3) MPa
[(1,0 to 3,0) bar]
temperature   ≤ 70 °C a   ≤ 42 °C
a   This maximum temperature limit can only be reached for short durations not greater than 1 h.
Key
1   cold water
2   hot water
3   mains supply pipe (supply pressures up to 10 bar)
4   water heater
Figure 1 — Supply system with a pressure range of (0,05 to 1,0) MPa [(0,5 to 10) bar]
Health and quality requirements in accordance to European and national legislation for final materials in contact with water intended for human consumption are not covered by this document.

Sanitärarmaturen - Messung der Funktionsfähigkeit von Armaturen und Brausen

Dieses Dokument bezieht sich auf den Anwendungsbereich von Armaturen, Brausen, Brausegarnituren und Brausesystemen in Wasserversorgungssystemen mit einem Druckbereich von (0,05 bis 1,0) MPa [0,5 bis 10] bar.
Die in diesem Dokument beschriebenen Prüfungen sind Typprüfungen (Laborprüfungen) und keine Qualitätsprüfungen, die während der Herstellung durchgeführt werden.
Dieses Dokument behandelt Folgendes:
-   Armaturen der Größe PN 10;
-   Brausen der Größe PN 5;
-   Brausegarnituren der Größe PN 5;
-   Brausesysteme der Größe PN 10.
Die folgenden Produkte werden in diesem Dokument nicht behandelt:
-   Brausearmaturen selbst;
-   Armaturen zum Füllen von Badewannen;
-   die Funktion zum Füllen von Badewannen bei Mischbatterien;
-   die Funktion einer Armatur, die z. B. kochendes Wasser oder Sprudelwasser usw. liefert;
-   Körper- oder Seitenbrausen.
Die Anwendungsbedingungen für Armaturen und Brausesysteme sind in Tabelle 1 angegeben. Die Anwendungsbedingungen für Brausegarnituren und Brausen sind in Tabelle 2 angegeben.
Tabelle 1 - Anwendungsbedingungen für Armaturen und Brausesysteme
ANMERKUNG   Armaturen und Brausesysteme für die Anwendung bei Drücken, die geringer sind als in Tabelle 1 angegeben, werden in dieser Norm nicht behandelt.
Tabelle 2 - Anwendungsbedingungen für Brausen und Brausegarnituren
Bild 1 - Versorgungssystem mit einem Druckbereich von (0,05 bis 1,0) MPa [(0,5 bis 10) bar]
Gesundheits- und Qualitätsanforderungen nach der europäischen und nationalen Gesetzgebung für Endmaterialien, die Kontakt mit Wasser für den menschlichen Gebrauch haben, werden in diesem Dokument nicht behandelt.

Robinetterie sanitaire - Mesure des performances fonctionnelles des robinets et des douches

Le présent document inclut dans son champ d’application les robinets, douches, sets de douche et colonnes de douche utilisés dans les systèmes d’alimentation en eau fonctionnant dans une plage de pression de (0,05 à 1,0) MPa [(0,5 à 10) bar].
Les essais décrits dans le présent document sont des essais de type (essais en laboratoire) et non des essais de contrôle qualité effectués en cours de fabrication.
Le présent document couvre les produits suivants :
—   robinets PN10 ;
—   douches PN5 ;
—   sets de douche PN5 ;
—   colonnes de douche PN10.
Il ne s’applique pas aux produits suivants :
—   robinets de douche seuls ;
—   robinets de remplissage de baignoire ;
—   fonction de remplissage de baignoire des robinets mélangeurs ;
—   fonction d’un robinet qui fournit par exemple de l’eau bouillante, de l’eau gazeuse, etc. ;
—   corps de douche latérale ou douches à jets latéraux.
Les conditions d’utilisation des robinets et des colonnes de douche sont données dans le Tableau 1. Les conditions d’utilisation des sets de douche et des douches sont données dans le Tableau 2.
Tableau 1 — Conditions d’utilisation des robinets et des colonnes de douche
Système d’alimentation en eau   Plage de fonctionnement des robinets et des colonnes de douche
   Limites   Recommandation
voir Figure 1   pression dynamique
≥ 0,05 MPa
(0,5 bar)
pression statique
≤ 1,0 MPa
(10,0 bar)   pression dynamique b
(0,1 à 0,5) MPa
[(1,0 à 5,0) bar]
température   ≤ 70 °C a   ≤ 65 °C
a   Cette limite de température maximale ne peut être atteinte que pendant de courtes durées qui ne dépassent pas 1 h.
b   Mesurée au point de déversement.
NOTE   Les robinets et les colonnes de douche destinés à être utilisés à des pressions inférieures à celles du Tableau 1 ne sont pas couverts par la présente norme.
Tableau 2 — Conditions d’utilisation des douches et des sets de douche
Système d’alimentation en eau   Plage de fonctionnement des douches
   Limites   Recommandation
voir Figure 1   pression dynamique
≥ 0,05 MPa
(0,5 bar)
pression statique
≤ 0,5 MPa
(5,0 bar)   pression dynamique
(0,1 à 0,3) MPa
[(1,0 à 3,0) bar]
température   ≤ 70 °C a   ≤ 42 °C
a   Cette limite de température maximale ne peut être atteinte que pendant de courtes durées qui ne dépassent pas 1 h.
Légende
1   eau froide
2   eau chaude
3   alimentation réseau (pressions d’alimentation allant jusqu’à 10 bar)
4   chauffe-eau
Figure 1 — Système d’alimentation dans une plage de pression de (0,05 à 1,0) MPa [(0,5 à 10) bar]
Le présent document ne traite pas des exigences de santé et de qualité fixées par la législation européenne et les réglementations nationales relatives aux matériaux finaux en contact avec l’eau destinée à la consommation humaine.

Sanitarne armature - Merjenje funkcionalne učinkovitosti pip in tušev

Ta dokument opredeljuje področje uporabe pip ter izpustov, kompletov in sistemov za tuš, ki se uporabljajo v sistemih oskrbe z vodo z območjem tlaka od (0,05 do 1,0) MPa [(0,5 do 10) barov]. Preskusi, opisani v tem dokumentu, so tipski preskusi (laboratorijski preskusi) in ne kontrolni preskusi kakovosti, opravljeni med proizvodnjo. Ta dokument obravnava: – pipe PN10; – izpuste za tuš PN5; – komplete za tuš PN5; – sisteme za tuš PN10. Naslednji izdelki so izključeni iz dokumenta: – samostojne pipe za tuš; – armature za polnjenje kadi;​– funkcija polnjenja kadi pri kombiniranih pipah; – funkcija pipe za dovajanje npr. vrele ali gazirane vode itd.; – pršne šobe ali stranske prhe. Pogoji uporabe pip in sistemov za tuš so navedeni v preglednici 1. Pogoji uporabe kompletov in izpustov za tuš so navedeni v preglednici 2. Preglednica 1 – Pogoji uporabe za pipe in sisteme za tuš Sistem oskrbe z vodo Območje delovanja pip in sistemov za tuš Omejitve Priporočeno glej sliko 1 dinamični tlak ≥ 0,05 MPa (0,5 bara) statični tlak ≤ 1,0 MPa (10,0 bara) dinamični tlak b (0,1 do 0,5) MPa [(1,0 do 5,0) bara] temperatura ≤ 70 °C a ≤ 65 °C a To največjo omejitev temperature je mogoče doseči za kratek čas (največ 1 h). b Merjeno na mestu izpusta. OPOMBA: Pipe in sistemi za tuš za uporabo pri vrednostih tlaka, nižjih od vrednosti v preglednici 1, niso zajeti v tem standardu. Preglednica 2 – Pogoji uporabe za izpuste in komplete za tuš Sistem oskrbe z vodo Območje delovanja tušev Omejitve Priporočeno glej sliko 1 dinamični tlak ≥ 0,05 MPa (0,5 bara) statični tlak ≤ 0,5 MPa (5,0 bara) dinamični tlak (0,1 do 0,3) MPa [(1,0 do 3,0) bara] temperatura ≤ 70 °C a ≤ 42 °C a To največjo omejitev temperature je mogoče doseči za kratek čas (največ 1 h). Legenda 1 hladna voda 2 vroča voda 3 oskrbovalna cev (dovodni tlak do 10 barov) 4 grelnik vode Slika 1 – Sistem oskrbe z vodo z območjem tlaka (0,05 do 1,0) MPa [(0,5 do 10) barov] Zahteve v zvezi z zdravjem in kakovostno ustreznostjo materialov, ki pridejo v stik z vodo, namenjeno pitju, v skladu z evropsko in nacionalno zakonodajo, niso zajete v tem dokumentu.

General Information

Status
Published
Publication Date
01-Jul-2025
Current Stage
6060 - Definitive text made available (DAV) - Publishing
Start Date
02-Jul-2025
Due Date
18-Apr-2024
Completion Date
02-Jul-2025
Standard
EN 18021:2025
English language
41 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-september-2025
Sanitarne armature - Merjenje funkcionalne učinkovitosti pip in tušev
Sanitary tapware - Measurement of functional performance of taps and showers
Sanitärarmaturen - Messung der Funktionsfähigkeit von Armaturen und Brausen
Robinetterie sanitaire - Mesure des performances fonctionnelles des robinets et des
douches
Ta slovenski standard je istoveten z: EN 18021:2025
ICS:
91.140.70 Sanitarne naprave Sanitary installations
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EN 18021
EUROPEAN STANDARD
NORME EUROPÉENNE
July 2025
EUROPÄISCHE NORM
ICS 91.140.70
English Version
Sanitary tapware - Measurement of functional
performance of taps and showers
Robinetterie sanitaire - Mesure des performances Sanitärarmaturen - Messung der Funktionsfähigkeit
fonctionnelles des robinets et des douches von Armaturen und Brausen
This European Standard was approved by CEN on 4 May 2025.

CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this
European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references
concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN
member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by
translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management
Centre has the same status as the official versions.

CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway,
Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Türkiye and
United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION

EUROPÄISCHES KOMITEE FÜR NORMUNG

CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2025 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 18021:2025 E
worldwide for CEN national Members.

Contents Page
European foreword . 4
Introduction . 5
1 Scope . 6
2 Normative references . 8
3 Terms and definitions . 8
4 Standard use cases . 11
5 Instructions . 13
5.1 General. 13
5.2 Replacement of components . 13
6 Technical criteria . 13
6.1 General. 13
6.2 Apparatus . 15
6.3 Energy calculation . 15
6.4 Use of flow regulators. 17
7 Taps . 17
7.1 General. 17
7.2 Flow rate testing . 17
7.2.1 Principle . 17
7.2.2 Apparatus . 17
7.2.3 Procedure . 17
7.3 Functional test . 18
7.3.1 Nominal flow rate . 18
7.3.2 Water break . 18
7.3.3 Boost function . 19
7.3.4 Cold start . 20
7.3.5 Temperature break . 20
7.3.6 Pressure independency . 21
7.3.7 Sensor function . 21
7.3.8 Time flow . 22
7.3.9 Sensitivity single lever taps. 23
7.3.10 Sensitivity thermostatic mixing valves . 23
7.3.11 Fidelity . 23
7.4 Rinsing performance . 23
7.4.1 General. 23
7.4.2 Requirement . 24
8 Shower outlets . 24
8.1 General. 24
8.2 Flow rate . 24
8.2.1 Principle . 24
8.2.2 Apparatus . 25
8.2.3 Procedure . 25
8.3 Functional test . 25
8.3.1 Nominal flow rate . 25
8.3.2 Boost function . 25
8.3.3 Pressure independency . 26
8.3.4 Spray coverage. 26
8.3.5 Spray force . 29
8.3.6 Spray dripping . 31
8.3.7 Spray pattern. 31
8.4 Rinsing performance . 32
8.4.1 General . 32
8.4.2 Requirement . 32
9 Shower sets . 32
9.1 General . 32
9.2 Rinsing performance . 32
9.2.1 General . 32
9.2.2 Requirement . 32
10 Shower systems . 33
10.1 General . 33
10.2 Flow rate . 33
10.2.1 General . 33
10.2.2 Principle . 33
10.2.3 Apparatus . 33
10.2.4 Procedure . 33
10.3 Functional test . 33
10.3.1 Nominal flow rate . 33
10.3.2 Pressure independency . 33
10.3.3 Spray coverage. 34
10.3.4 Spray force . 34
10.3.5 Spray dripping . 34
10.3.6 Spray pattern. 34
10.3.7 Water break .
...