EN 835:1994
(Main)Heat cost allocators for the determination of the consumption of room heating radiators - Appliances without an electrical energy supply, based on the evaporation principle
- BACK
- 18-Oct-1994
- 91.140.10
- CEN/TC 171
Heat cost allocators for the determination of the consumption of room heating radiators - Appliances without an electrical energy supply, based on the evaporation principle
Heat cost allocators in accordance with this standard are instruments for the registration of the heat output of radiators in consumer units. Consumer units are dwellings, office buildings, business premises, industrial plants in which the heat is supplied by a common central heating systems or by a common district heating connection. A complete grouping of consumer units is called an account unit.
Heizkostenverteiler für die Verbrauchswerterfassung von Raumheizflächen - Geräte ohne elektrische Energieversorgung nach dem Verdunstungsprinzip
Heizkostenverteiler nach dieser Norm sind Instrumente zur Erfassung der Wärmeabgabe von Heizkörpern in Nutzeinheiten. Unter Nutzeinheiten sind Wohnungs-, Büro-, Geschäfts-, Gewerbe- oder Industrieräumlichkeiten zu verstehen, deren Wärmeversorgung durch eine gemeinsame Zentralheizunsanlage oder über einen gemeinsamen Fernwärmeanschluß erfolgt. Die Gesamtheit der Nutzeinheiten bildet eine Abrechnungseinheit.
Répartiteurs de frais de chauffage pour enregistrer les valeurs de consommation de surfaces de corps de chauffe - Appareils sans alimentation en énergie électrique en vertu du principe d'évaporation
Les répartiteurs de frais de chauffage conformes à cette norme sont des instruments destinés à mesurer la chaleur émise par des radiateurs dans les unités d'utilisation. On entend par unités d'utilisation des locaux d'habitation, des locaux commerciaux, professionnels ou industriels et des bureaux, dont l'approvisionnement en chaleur se fait au moyen d'une installationde chauffage central ou par le truchement d'un raccordement commun à un système de chauffage urbain. L'ensemble des unités d'utilisation constitue une unité de calcul des frais.
Delilniki stroškov porabe toplote ogreval – Naprave brez električnega napajanja na osnovi izhlapevanja
General Information
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Heizkostenverteiler für die Verbrauchswerterfassung von Raumheizflächen - Geräte ohne elektrische Energieversorgung nach dem VerdunstungsprinzipRépartiteurs de frais de chauffage pour enregistrer les valeurs de consommation de surfaces de corps de chauffe - Appareils sans alimentation en énergie électrique en vertu du principe d'évaporationHeat cost allocators for the determination of the consumption of room heating radiators - Appliances without an electrical energy supply, based on the evaporation principle91.140.10Sistemi c
...
This May Also Interest You
CEN/TC 171 origin - New Figure 1 so as to correct inconsistency in three language versions. No xml version as the mother standard EN 834:2013 is not available as an xml file.
- Corrigendum2 pagesEnglish languagesale 10% offe-Library read for×1 day
- 21-Apr-2015
- 91.140.10
- CEN/TC 171
NOTE See Clause 3 for a definition of the terms used below.
This European standard applies to heat cost allocators which are used to capture the proportionate thermal output of radiators in consumer units.
If an account unit comprises consumer units of different types (e.g. technically different types of heating systems or differences due to the consumer behaviour, e.g. industrial plants as opposed to private apartments), it could be necessary to divide this account unit into groups of users.
Heat cost allocators enable the determination of the heat consumption only of each radiator in a consumer unit as a share of the total heat consumption of the account unit or user group (see Clause 4); it is therefore necessary to determine this total heat consumption either by measuring the consumed fuel quantity or the amount of heat delivered (the latter by means of a heat meter, for example).
For the appropriate use of the heat cost allocators in accordance with this standard, the heating system needs to:
- correspond to the state of the art at the time of installation of the heat cost allocators;
- be operated in accordance with the state of the art (see A.2).
This standard specifies that heat cost allocators shall not be used for heating systems where the temperature of the heating system falls below or exceeds the temperature limits of the heat cost allocators, where the rating factor for the thermal output, KQ, cannot be clearly specified or where the heating surface is inaccessible. This applies usually to the following heating systems:
- floor heating;
- radiant ceiling heating;
- flap controlled radiators;
- radiators with ventilators;
- fan assisted air heaters;
- heating systems with steam operated radiators.
- Standard32 pagesEnglish languagesale 10% offe-Library read for×1 day
- 06-Aug-2013
- 27-Feb-2014
- 91.140.10
- CEN/TC 171
This document specifies, the requirements and test methods concerning the classification and marking of gas-fired central heating boilers that are fitted with atmospheric burners, fan assisted atmospheric burners and are hereafter referred to as “boilers”.
Where the word boiler is used, this is intended to be read as the boiler including its connecting ducts, ducts and terminals, if any.
This document covers gas-fired central heating boilers type B11, B11BS, B12, B12BS, B13, B13BS:
NOTE 1 For further background information on appliance types see EN 1749:2020.
a) that have a nominal heat input (on the basis of net calorific value) not exceeding 70 kW;
b) that use one or more combustible gases of the three gas families at the pressures stated in EN 437:2021;
c) where the temperature of the heat transfer fluid does not exceed 105 °C during normal operation;
d) where the maximum operating pressure in the water circuit does not exceed 6 bar;
e) which are declared in the technical instructions to be either a “low temperature boiler” or a “standard boiler”. If no declaration is given the boiler is to be considered a “standard boiler”;
f) which are intended to be installed inside a building or in a partially protected place;
g) which are intended to produce also hot water either by the instantaneous or storage principle, as a single unit;
h) which are designed for either sealed water systems or for open water systems.
NOTE 2 This document provides requirements for boilers with known constructions. For boilers with any alternative constructions, which might not fully be covered by this document, the risk associated with this alternative construction needs to be assessed.
An example of an assessment methodology, based upon risk assessment, is given in Clause 11.
This document does not cover all the requirements for:
aa) appliances that are intended to be connected to gas grids where the quality of the distributed gas is likely to vary to a large extent over the lifetime of the appliance (see Annex AB);
ab) appliances using flue dampers;
ac) appliances that have a nominal heat input (on the basis of net calorific value) exceeding 70 kW;
ad) appliances of the types A, B14, B¬2, B3, B4, B5 and C;
ae) appliances intended to be connected to a (common) flue having mechanical extraction;
af) appliances with gas/air ratio control;
ag) modular boilers;
ah) boilers which can give rise to condensation under certain circumstances;
ai) boilers intended to be installed in a room with a foreseeable negative pressure relative to the pressure in the flue system;
aj) surface temperatures of external parts particular to children and elderly people;
ak) appliances that are intended to burn natural gases of the second family where hydrogen is added to the natural gas;
al) boilers intended to be installed in areas accessible to elderly people and children;
am) boilers equipped with an adaptive combustion control function (ACCF).
NOTE Negative pressure relative to the pressure in the flue system can for example be caused by mechanical or thermal ventilation in airtight buildings.
- Draft64 pagesEnglish languagesale 10% offe-Library read for×1 day
This document is applicable to technical insulation systems of operational installations in industry and the building services, such as pipes, ducts, vessels, equipment and built-in components.
The document specifies methods for the energy efficiency classification of insulation systems for the abovementioned components with an operational temperature range of −30 °C up to 650 °C.
The document addresses plant operators, engineers of operational installations, as well as the involved contractors such as insulation contractors and pipefitting contractors.
The design of safe surface temperatures for personal protection, as well as the prevention of condensation, is outside the scope of this document.
This document also does not apply to water-based heating and cooling systems in buildings and does not apply to directly buried district heating and district cooling pipes.
- Standard29 pagesEnglish languagesale 10% offe-Library read for×1 day
- 04-Jun-2024
- 91.120.10
- 91.140.10
- 91.140.30
- CEN/TC 228
Scope of CEN/TS 15502-3-1
EN 15502-2-1:2022, Clause 1 applies with the following modifications:
Add after k):
l) which are fully premixed appliances equipped with an Adaptive Combustion Control Function (ACCF) that are intended to be connected to gas grids where the quality of the distributed gas is likely to vary to a large extent over the lifetime of the appliance including gas grids for natural gases of the second family where up to 20% hydrogen volume is added to the natural gas (H2NG-Y20).
m) which are fully premixed appliances equipped with a Pneumatic Gas Air Ratio controller (PGAR) that are intended to be connected to gas grids for natural gases of the second family where up to 20% hydrogen volume is added to the natural gas (H2NG-Y20), where the quality of the distributed gas without adding the hydrogen is not likely to vary to a large extent over the lifetime of the appliance.
Replace ab) and ak) and al) by the following:
ab) appliances that are intended to be connected to gas grids where the quality of the distributed gas is likely to vary to a large extent over the lifetime of the appliance (see Annex AB of EN 15502-1:2021), except for fully premixed appliances with a ACCF, as ACCF appliances are designed to adapt to variations in gas quality.
ak) appliances that are intended to burn natural gases of the second family where hydrogen is added to the natural gas, except for fully premixed appliances with a ACCF or PGAR (which are covered by this document);
al) Partially premixed appliances equipped with an adaptive combustion control function (ACCF).
- Draft58 pagesEnglish languagesale 10% offe-Library read for×1 day
- 14-May-2024
- 27.060.30
- 27.075
- 91.140.10
- CEN/TC 109
This document specifies the requirements and test methods, as well as the classification and marking of gas-fired central heating boilers that are fitted with atmospheric burners, fan assisted atmospheric burners or fully premixed burners, and are hereafter referred to as "boilers".
This document is intended to be used in conjunction with EN 15502-1:2021.
This document covers gas-fired central heating boilers from the types C1 up to C(11) and the types B2, B3 and B5:
NOTE 1 For further background information on appliance types see EN 1749:2020.
a) that have a nominal heat input (on the basis of net calorific value) not exceeding 1 000 kW;
b) that use one or more combustible gases of the three gas families at the pressures stated in EN 437:2021;
c) where the temperature of the heat transfer fluid does not exceed 105 °C during normal operation;
d) where the maximum operating pressure in the water circuit does not exceed 6 bar;
e) which can give rise to condensation under certain circumstances;
f) which are declared in the instructions for installation to be either a "condensing" boiler or a "low temperature boiler" or a "standard boiler"; if no declaration is given the boiler is to be considered a "standard boiler";
g) which are intended to be installed inside a building or in a partially protected place;
h) which are intended to produce also hot water either by the instantaneous or storage principle as a single unit;
i) which are designed for either sealed water systems or for open water systems;
j) which are either modular boilers, or non-modular boilers.
k) which are from the types C(10) that are equipped with a gas-air ratio control and that have a ∆pmax, saf(min) of 25 Pa, and C(11) that have condensing boiler modules that are equipped with a gas-air ratio control and that have a ∆pmax, saf(min) of 25 Pa.
NOTE 2 This document provides requirements for boilers with known constructions. For boilers with any alternative constructions, which might not fully be covered by this standard, the risk associated with this alternative construction needs to be assessed.
An example of an assessment methodology, based upon risk assessment, is given in Clause 11.
This document does not cover all the requirements for:
aa) appliances above 1 000 kW;
ab) appliances that are intended to be connected to gas grids where the quality of the distributed gas is likely to vary to a large extent over the lifetime of the appliance (see Annex AB of EN 15502-1:2021);
ac) appliances using flue dampers;
ad) appliances of the types B21, B31, B51, C21, C41, C51, C61, C71, C81, C(12) and C(13);
ae) C7 appliances that have a nominal heat input (on the basis of net calorific value) exceeding 70 kW;
af) appliances incorporating flexible plastic flue liners;
ag) C(10) boilers:
1) without a gas-air ratio control, or
2) which are non-condensing appliances, or
3) which have a maximum safety pressure difference at minimum heat input not equal to 25 Pa (∆pmax, saf(min));
ah) C(11) boilers that have boiler modules:
1) without a gas-air ratio control, or
2) which are non-condensing appliances, or
3) which have a maximum safety pressure difference at minimum heat input not equal to 25 Pa (∆pmax, saf(min));
ai) appliances intended to be connected to a flue having mechanical extraction;
aj) surface temperatures of external parts particular to children and elderly people;
ak) appliances that are intended to burn natural gases of the second family where hydrogen is added to the natural gas;
al) appliances equipped with an adaptive combustion control function (ACCF);
am) boilers intended to be installed in areas accessible to elderly people and children.
- Standard105 pagesEnglish languagesale 10% offe-Library read for×1 day
This European Standard specifies the common requirements and test methods, as well as the classification, marking and energy labelling of gas-fired central heating boilers that are fitted with atmospheric burners, fan assisted atmospheric burners or fully premixed burners, and are hereafter referred to as “boilers”.
This European Standard is to be used in conjunction with the specific Parts 2 (Part 2-1 and following ones).
This European Standard applies to boilers of types B and C.
NOTE For further background information on appliance types see CEN/TR 1749:2014 [1].
a) that use one or more combustible gases of the three gas families at the pressures stated in EN 437;
b) where the temperature of the water is below or above 105 °C during normal operation;
c) where the maximum operating pressure in the water circuit does not exceed 6 bar;
d) which can give rise to condensation under certain circumstances;
e) which are declared in the instructions for installation to be either a "condensing" boiler or a "low temperature boiler" or a "standard boiler" or an "other boiler". If no declaration is given the boiler is to be considered both a "standard boiler" and an "other boiler";
NOTE The Ecodesign Directive defines "other boilers", "low temperature boilers" and "condensing boilers". The Boiler Efficiency Directive defines "standard boilers", "low temperature boilers" and "condensing boilers". Depending on the legislation applied, a boiler can be both "a standard boiler" and an "other boiler"."
f) which are intended to be installed inside a building or in a partially protected place;
g) which are intended to produce also hot water either by the instantaneous or storage principle as a single unit.
This European Standard applies to boilers designed for sealed water systems or for open water systems.
NOTE This general standard and the specific standards (see Part 2) provide requirements for boilers with known constructions. For boilers with any alternative constructions, which might not fully be covered by this standard or a specific standard, the risk associated with this alternative construction will need to be assessed.
An example of an assessment methodology, based upon risk assessment, is given in Clause 11.
This European Standard is not intended to cover appliances intended for connection to gas grids where the quality of the distributed gas is likely to vary to a large extent over the lifetime of the appliance (see Annex EE).
This European Standard is not intended to cover appliances designed and constructed to burn gas containing toxic components.
- Standard213 pagesEnglish languagesale 10% offe-Library read for×1 day
This document specifies requirements and test methods for room temperature sensors used to control the room temperature.
This document is applicable to wall mounted and flush mounted room temperature sensors.
The following aspects are not covered by this document:
- pendulum temperature sensors;
- ceiling mounted temperature sensor;
- extract air temperature sensors.
NOTE The measured value available at the output of the sensor is influenced by the place where the sensor device is located and factors such as air velocity, wall temperature, self/waste heating of the device and the air temperature. The perceived temperature, which is important for the well-being of a person, depends among other factors on air temperature, temperature of the surrounding walls and air flow rate as indicated in EN ISO 7730.
The temperature sensor element can be combined with other sensors in one device. This document only deals with the room temperature sensing of this devices. Other sensors are not covered except of their influence on the room temperature sensing (e.g. self-heating).
This document specifies sensor characteristics contributing to the determination of the control accuracy of individual zone controller according to EN 15500 1.
- Standard41 pagesEnglish languagesale 10% offe-Library read for×1 day
- 07-Nov-2023
- 17.200.20
- 91.140.10
- CEN/TC 247
This document specifies the requirements and tests methods concerning the construction, safety, fitness for purpose, and rational use of energy, as well as the classification and marking of hybrid units.
A hybrid unit is composed of:
- a gas boiler as a heat generator which is able to supply the heat demand in all operating conditions;
- an electrical air-to-water heat pump, as a heat generator, which does not have to meet the heat demand in all operating conditions;
- a control unit (see definition 3.1.10).
A hybrid unit can include the facility to produce hot water, either by the instantaneous or storage principle, the whole being marketed as a single unit.
A gas boiler as part of a hybrid unit covered by this document is a gas-fired central heating boiler from the types C1 up to C9 and the types B2, B3 and B5, according to the classification in EN 1749:2020:
a) that have a nominal heat input (on the basis of gross calorific value) not exceeding 400 kW;
b) that use one or more combustible gases of the three gas families at the pressures stated in EN 437:2021;
c) where the temperature of the heat transfer fluid does not exceed 105 °C during normal operation;
d) where the maximum operating pressure in the water circuit does not exceed 6 bar;
e) which are classified as a gas-fired central heating boiler;
f) which are intended to be installed either indoors or outdoors in a partially protected place;
g) which are designed for either sealed water systems or for open water systems.
This document provides requirements for boilers with known constructions.
NOTE 1 For boilers with any alternative constructions, which might not fully be covered by this document, the risk associated with this alternative construction needs to be assessed.
NOTE 2 An example of an assessment methodology, based upon risk assessment and which covers the essential requirements of the Gas Appliance Regulation UE/426/2016, is given in Clause 11.
This document does not cover all the requirements for:
aa) appliances that are intended to be connected to gas grids where the quality of the distributed gas is likely to vary to a large extent over the lifetime of the appliance (see EN 15502-1:2021, Annex AB);
ab) appliances using flue dampers;
ac) appliances of the types B21, B31, B51, C21, C41, C51, C61, C71 and C81;
ad) appliances incorporating flexible plastic flue liners;
ae) appliances designed to become connected to a combined flue duct system.
af) appliances of the types C(10),C(11), C(12) and C(13);
ag) C7 appliances that have a nominal heat input (on the basis of net calorific value) exceeding 70 kW;
ah) appliances intended to be connected to a flue having mechanical extraction;
ai) surface temperatures of external parts particular to children and elderly people;
aj) appliances that are intended to burn natural gases of the second family where hydrogen is added to the natural gas;
ak) appliances equipped with an adaptive combustion control function (ACCF);
al) boilers intended to be installed in areas accessible to elderly people and children.
This document specifies minimum operating requirements which ensure that the products are fit for the use designated by the technical instructions when used for space heating and/or DHW production.
This document is intended to be used in conjunction with:
ba) the gas-fired boiler, the generic part EN 15502-1:2021 and specific parts FprEN 15502-2-1:2022 and FprEN 15502-2-2:2022;
bb) the electrical heat pump, EN 14511-4:2018, EN 378-1:2016+A1:2020, EN 378-2:2016 and EN 14825:2022;
bc) electrical safety, EN 60335-1:2012 , EN 60335-2-102:2016 and IEC 60335-2-40:2018;
bd) for domestic hot water production, EN 13203-5:2022.
- Standard42 pagesEnglish languagesale 10% offe-Library read for×1 day
This document covers standardization in the field of geological and environmental aspects, design, construction, operation, monitoring, maintenance and decommissioning of grouted borehole heat exchangers for uses in geothermal energy systems.
This document is only applicable for backfilled and grouted boreholes, it is not applicable for groundwater-filled boreholes.
Direct expansion and thermal syphon techniques are excluded from this document.
- Standard61 pagesEnglish languagesale 10% offe-Library read for×1 day
- 04-Apr-2023
- 07.060
- 27.190
- 91.140.10
- CEN/TC 451