Factory-made double skin metal faced insulating sandwich panels - Part 4: Test methods for fixing of panels to substructure and for determining restraining effect on substructure

This European Standard specifies test methods needed for determination of characteristics for fixing of
factory-made double skin metal faced insulating sandwich panels (hereafter sandwich panels) to substructure and for stabilization of substructure. The sandwich panels are for use in elements for both self-supporting and structural applications in roofs, in external and internal walls (including partitions) and in ceilings in buildings as well as those in cold store applications.
NOTE The description of self-supporting sandwich panels is given in prEN 14509-1 and for structural
sandwich panels in FprEN 14509-2.

Werkmäßig hergestellte Sandwich-Elemente mit beidseitigen Metalldeckschichten - Teil 4: Prüfverfahren zur Befestigung von Paneelen an der Unterkonstruktion und zur Bestimmung der Rückhaltewirkung auf die Unterkonstruktion

Dieses Dokument legt Prüfverfahren für die Bestimmung von Merkmalen für die Befestigung von werkmäßig hergestellten Sandwich-Elementen mit beidseitigen Metalldeckschichten (im Folgenden: Sandwich-Elemente) an der Unterkonstruktion und für die Stabilisierung der Unterkonstruktion fest. Die Sandwich-Elemente sind für den Einsatz in Elementen sowohl für selbsttragende als auch für tragende Anwendungen in Dächern, in Außen- und Innenwänden (einschließlich Trennwänden) und in (Unter )Decken in Gebäuden sowie in solchen für Kühlhausanwendungen vorgesehen.
ANMERKUNG   Die Beschreibung für selbsttragende Sandwich-Elemente ist in prEN 14509 1 und für tragende Sandwich-Elemente in FprEN 14509 2 angegeben.

Panneaux sandwiches isolants à deux parements métalliques manufacturés - Partie 4: Méthodes d'essai pour les assemblages des panneaux à la sous-structure et pour la détermination de l'effet de retenue sur la sous-structure

Le présent document spécifie les méthodes d'essai pour la détermination des caractéristiques de fixation des panneaux sandwiches isolants à deux parements métalliques manufacturés (ci-après dénommés panneaux sandwiches) pour la sous-structure et pour la stabilisation de la sous-structure. Les panneaux sandwiches sont utilisés dans les éléments pour applications autoportantes et structurelles dans les toitures, les parois extérieures et intérieures (y compris les cloisons), et les plafonds dans les bâtiments, ainsi que pour les applications en chambres froides.
NOTE   La description des panneaux sandwiches autoportants est fournie dans le prEN 14509-1, et celle des panneaux sandwiches structurels dans le FprEN 14509-2.

Tovarniško izdelane izolacijske sendvič plošče z obojestranskim kovinskim oplaščenjem - 4. del: Preskusne metode za pritrjevanje plošč na podkonstrukcijo in za določanje učinka zadrževanja na podkonstrukciji

General Information

Status
Not Published
Publication Date
08-Feb-2023
Current Stage
4098 - Decision to abandon - Enquiry
Completion Date
30-Sep-2022

Buy Standard

Draft
prEN 14509-4:2021 - BARVE
English language
37 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-november-2021
Tovarniško izdelane izolacijske sendvič plošče z obojestranskim kovinskim
oplaščenjem - 4. del: Preskusne metode za pritrjevanje plošč na podkonstrukcijo
in za določanje učinka zadrževanja na podkonstrukciji
Factory-made double skin metal faced insulating sandwich panels - Part 4: Test methods
for fixing of panels to substructure and for determining restraining effect on substructure
Werkmäßig hergestellte Sandwich-Elemente mit beidseitigen Metalldeckschichten - Teil
4: Prüfverfahren zur Befestigung von Paneelen an der Unterkonstruktion und zur
Bestimmung der Rückhaltewirkung auf die Unterkonstruktion
Panneaux sandwiches isolants à deux parements métalliques manufacturés - Partie 4:
Méthodes d'essai pour les assemblages des panneaux à la sous-structure et pour la
détermination de l'effet de retenue sur la sous-structure
Ta slovenski standard je istoveten z: prEN 14509-4
ICS:
91.100.60 Materiali za toplotno in Thermal and sound insulating
zvočno izolacijo materials
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

DRAFT
EUROPEAN STANDARD
NORME EUROPÉENNE
EUROPÄISCHE NORM
August 2021
ICS 91.100.60
English Version
Factory-made double skin metal faced insulating sandwich
panels - Part 4: Test methods for fixing of panels to
substructure and for determining restraining effect on
substructure
Panneaux sandwiches isolants à deux parements Werkmäßig hergestellte Sandwich-Elemente mit
métalliques manufacturés - Partie 4: Méthodes d'essai beidseitigen Metalldeckschichten - Teil 4:
pour les assemblages des panneaux à la sous-structure Prüfverfahren zur Befestigung von Paneelen an der
et pour la détermination de l'effet de retenue sur la Unterkonstruktion und zur Bestimmung der
sous-structure Rückhaltewirkung auf die Unterkonstruktion
This draft European Standard is submitted to CEN members for enquiry. It has been drawn up by the Technical Committee
CEN/TC 128.
If this draft becomes a European Standard, CEN members are bound to comply with the CEN/CENELEC Internal Regulations
which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.

This draft European Standard was established by CEN in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC
Management Centre has the same status as the official versions.

CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway,
Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and
United Kingdom.
Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are
aware and to provide supporting documentation.

Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without
notice and shall not be referred to as a European Standard.

EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION

EUROPÄISCHES KOMITEE FÜR NORMUNG

CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2021 CEN All rights of exploitation in any form and by any means reserved Ref. No. prEN 14509-4:2021 E
worldwide for CEN national Members.

Contents Page
European foreword .3
Introduction .4
1 Scope .5
2 Normative references .5
3 Terms, definitions, symbols, subscripts and abbreviations .5
3.1 Terms and definitions .5
3.2 Symbols, subscripts and abbreviations .6
4 Testing of the resistance of fixings of sandwich panels to supporting structures .8
4.1 General .8
4.2 Tensile resistance . 11
4.3 Shear resistance . 18
4.4 Full scale tests, alternative test method for tensile resistance of hidden fixing . 20
4.5 Shortened test programme . 26
4.6 Determination of γ . 26
M
5 Parameters needed for determining restraining effect of sandwich panels when connected
to supporting structures. 26
5.1 Principle . 26
5.2 Rotational spring stiffness . 27
5.3 Shear stiffness S for lateral restraint of an individual member . 35
Bibliography . 37

European foreword
This document (prEN 14509-4:2021) has been prepared by Technical Committee CEN/TC 128 “Roof
covering products for discontinuous laying and products for wall cladding”, the secretariat of which is
held by NBN.
This document is currently submitted to the CEN Enquiry.
Introduction
The principles for determination of declared values of the characteristics to be expressed are given in
prEN 14509-1 for self-supporting applications and in FprEN 14509-2 for structural applications.
1 Scope
This document specifies test methods for determination of characteristics for fixing of factory-made
double skin metal faced insulating sandwich panels (hereafter referred to as sandwich panels) to
substructure and for stabilization of substructure. Sandwich panels are used in elements for both self-
supporting and structural applications in roofs, in external and internal walls (including partitions) and
in ceilings in buildings as well as those in cold store applications.
NOTE The description of self-supporting sandwich panels is given in prEN 14509-1 and for structural
sandwich panels in FprEN 14509-2.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments) applies.
EN 1990, Eurocode - Basis of structural design
EN 1993-1-3:2006, Eurocode 3 - Design of steel structures - Part 1-3: General rules - Supplementary rules
for cold-formed members and sheeting
EN 13165, Thermal insulation products for buildings - Factory made rigid polyurethane foam (PU)
products - Specification
FprEN 14509-2:2021, Factory made double skin metal faced insulating sandwich panels - Part 2:
Structural applications
prEN 14509-3:2021, Factory made double skin metal faced insulating sandwich panels - Part 3: Test
methods for determining mechanical strength, building physical behaviour and durability
prEN 14509-5:2021, Factory made double skin metal faced insulating sandwich panels - Part 5: Design
methods. Determination criteria for combing actions and spans
3 Terms, definitions, symbols, subscripts and abbreviations
3.1 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
3.1.1
bond, bonding
adhesion between the face(s) and the core normally provided by an adhesive
3.1.2
ceiling
covering over an internal area
3.1.3
core
layer of material, having thermal insulating properties, which is bonded between two metal faces,
thickness of metal face minus thickness of metal and organic coating

As impacted by EN 1993-1-3:2006/AC:2009.
Note 1 to entry: Panels with special edge details in the longitudinal joints may utilize different core materials from
the main insulating core (e.g. for improved fire performance) if these edge details do not influence on mechanical
performance of the panel.
3.1.4
edge, longitudinal edge
side of the panel where adjacent panels join together in the same plane
3.1.5
face, facing
flat, lightly profiled or profiled thin metal sheet firmly bonded to the core
3.1.6
joint
interface between two panels where the meeting edges have been designed to allow the panels to join
together in the same plane
Note 1 to entry: The joint may incorporate interlocking parts that enhance the mechanical properties of the
system as well as improving the thermal, acoustic and fire performance and restricting air movement.
Note 2 to entry: The term 'joint' does not refer to a junction between cut panels or a junction where the panels are
not installed in the same plane.
3.1.7
lamella
core material consisting of mineral wool that has been cut and orientated with the fibres perpendicular
to the facings prior to bonding
3.1.8
sandwich panel
building product consisting of two metal faces positioned on either side of a core that is a thermally
insulating material, which is firmly bonded to both faces so that the three components act compositely
when under load
3.2 Symbols, subscripts and abbreviations
For the purposes of this document, the following symbols, subscripts and abbreviations apply.
3.2.1 Symbols
B overall width of the panel/specimen,
C ratio
D overall thickness of the panel
E modulus of elasticity
F force, load, support reaction
G shear modulus
L span, distance, width of support (L )
s
M bending moment
Q load
R resistance
S shear rigidity
V shear force
b width of test specimen
d depth of face profile or stiffeners, depth of core (d )
c
e distance between centroids of faces, base of natural logarithms (e = 2,718 282)
f strength, yield stress
h height of profile
k parameter, correction factor
l length
m mass
n number of tests, number of screws, number of webs
t thickness of face sheet
w deflection, displacement
δ deviation
ϕ angle
γ shear strain
φ creep coefficient
3.2.2 Subscripts
A rotational stiffness (C )
D,A
C core
D expressed value, rotational stiffness (C )
D
F face
adj adjusted
-1
arcsin trigonometric function (inverse of sine function, sin )
-1
arctan trigonometric function (inverse of tangent function, tan )
c compression
d design
e external, additional thickness of main profiles (Δe)
eff effective
end end support
i internal
i, j index
int internal support
m material
nom nominal
o upper face
obs observed (e.g. result)
rep repeated (F )
Rtk,rep
Rtk characteristic (5%-fractile) value (F )
Rtk
s support (Ls = support width), stiffeners, surface (Rs1)
t tension, time
tol tolerance (normal or special)
tr traffic (Ctr)
u ultimate (Fu)
l lower face
v shear
0 basic value, unit width, time (e.g. t = 0)
1 upper face
supporting member
2 lower face
φ effect of creep on core module ( E φ )
ϑ,t ϑ,t
3.2.3 Abbreviations
EPS expanded polystyrene
MW mineral wool
PU rigid polyurethane foam (the abbreviation PUR includes polyisocyanurate foam (PIR))
PF phenolic foam
ULS ultimate limit state
XPS extruded polystyrene foam
4 Testing of the resistance of fixings of sandwich panels to supporting
structures
4.1 General
4.1.1 Type of fixings and panel families
This document covers the resistance of fixing of panels to supporting structures and the failure modes
in the sandwich panel. It does not cover the failure of the fastener itself or failure of the fixing in the
supporting structure. Thus, the failure mode for tension is generally a pull-through failure of the visible
fixing and the failure mode of the hidden fixing a failure of the joint or of the load spreading plate (if
applicable). A pull-through failure is used as a common name for these failure modes. In addition, the
shear failure mode of fixing is covered by this document.
The types of fixing of panels to supporting structure covered by this document are:
— visible fixings;
— hidden fixings.
NOTE 1 Combinations of these fixing types are also possible.
For the fixing of panels to supporting structure, failure modes in suppo
...

Questions, Comments and Discussion