Evaporated milk and sweetened condensed milk - Determination of fat content - Gravimetric method (Reference method) (ISO 1737:1999)

Kondensmilch und gezuckerte Kondensmilch - Bestimmung des Fettgehaltes - Gravimetrisches Verfahren (Referenzverfahren) (ISO 1737:1999)

Diese Internationale Norm legt das Referenzverfahren für die Bestimmung des Fettgehaltes aller Arten von Kondensmilch und gezuckerter Kondensmilch (flüssige gezuckerte und ungezuckerte Kondensmilch) fest.

Lait concentré sucré et non sucré - Détermination de la teneur en matière grasse - Méthode gravimétrique (Méthode de référence) (ISO 1737:1999)

Zgoščeno mleko in sladkano kondenzirano mleko - Določevanje maščobe - Gravimetrijska metoda (Referenčna metoda) (ISO 1737:1999)

General Information

Status
Withdrawn
Publication Date
30-Nov-1999
Withdrawal Date
14-Oct-2008
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
15-Oct-2008
Completion Date
15-Oct-2008

Relations

Buy Standard

Standard
EN ISO 1737:2000
English language
16 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN ISO 1737:2000
01-maj-2000
=JRãþHQRPOHNRLQVODGNDQRNRQGHQ]LUDQRPOHNR'RORþHYDQMHPDãþREH
*UDYLPHWULMVNDPHWRGD 5HIHUHQþQDPHWRGD  ,62
Evaporated milk and sweetened condensed milk - Determination of fat content -
Gravimetric method (Reference method) (ISO 1737:1999)
Kondensmilch und gezuckerte Kondensmilch - Bestimmung des Fettgehaltes -
Gravimetrisches Verfahren (Referenzverfahren) (ISO 1737:1999)
Lait concentré sucré et non sucré - Détermination de la teneur en matiere grasse -
Méthode gravimétrique (Méthode de référence) (ISO 1737:1999)
Ta slovenski standard je istoveten z: EN ISO 1737:1999
ICS:
67.100.10 0OHNRLQSUHGHODQLPOHþQL Milk and processed milk
SURL]YRGL products
SIST EN ISO 1737:2000 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN ISO 1737:2000

---------------------- Page: 2 ----------------------

SIST EN ISO 1737:2000

---------------------- Page: 3 ----------------------

SIST EN ISO 1737:2000

---------------------- Page: 4 ----------------------

SIST EN ISO 1737:2000
INTERNATIONAL ISO
STANDARD 1737
Third edition
1999-12-01
Evaporated milk and sweetened condensed
milk — Determination of fat content —
Gravimetric method (Reference method)
Lait concentré sucré et non sucré — Détermination de la teneur en matière
grasse — Méthode gravimétrique (Méthode de référence)
A
Reference number
ISO 1737:1999(E)

---------------------- Page: 5 ----------------------

SIST EN ISO 1737:2000
ISO 1737:1999(E)
Contents
1 Scope .1
2 Normative reference .1
3 Term and definition .1
4 Principle.1
5 Reagents.2
6 Apparatus .2
7 Sampling.3
8 Preparation of test sample.3
8.1 Evaporated milk .3
8.2 Sweetened condensed milk.4
9 Procedure .4
9.1 Test portion .4
9.2 Blank tests.4
9.3 Preparation of fat-collecting vessel .5
9.4 Determination.5
10 Calculation and expression of results.7
10.1 Calculation.7
10.2 Expression of results .7
11 Precision.8
11.1 Interlaboratory test .8
11.2 Repeatability.8
11.3 Reproducibility.8
12 Test report .8
©  ISO 1999
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic
or mechanical, including photocopying and microfilm, without permission in writing from the publisher.
International Organization for Standardization
Case postale 56 • CH-1211 Genève 20 • Switzerland
Internet iso@iso.ch
Printed in Switzerland
ii

---------------------- Page: 6 ----------------------

SIST EN ISO 1737:2000
©
ISO ISO 1737:1999(E)
Annex A (informative) Notes on procedures . 9
Annex B (informative) Alternative procedure using fat-extraction tubes with siphon or wash-bottle fittings . 11
Bibliography. 14
iii

---------------------- Page: 7 ----------------------

SIST EN ISO 1737:2000
©
ISO 1737:1999(E) ISO
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO
member bodies). The work of preparing International Standards is normally carried out through ISO technical
committees. Each member body interested in a subject for which a technical committee has been established has
the right to be represented on that committee. International organizations, governmental and non-governmental, in
liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical
Commission (IEC) on all matters of electrotechnical standardization.
International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 3.
Draft International Standards adopted by the technical committees are circulated to the member bodies for voting.
Publication as an International Standard requires approval by at least 75 % of the member bodies casting a vote.
International Standard ISO 1737 was prepared by Technical Committee ISO/TC 34, Agricultural food products,
Subcommittee SC 5, Milk and milk products, in collaboration with the International Dairy Federation (IDF) and
AOAC International, and will also be published by these organizations.
This third edition cancels and replaces the second edition (ISO 1737:1985), which has been technically revised.
Annexes A and B of this International Standard are for information only.
iv

---------------------- Page: 8 ----------------------

SIST EN ISO 1737:2000
©
INTERNATIONAL STANDARD  ISO ISO 1737:1999(E)
Evaporated milk and sweetened condensed milk —
Determination of fat content — Gravimetric method
(Reference method)
WARNING — The use of this International Standard may involve hazardous materials, operations and
equipment. This standard does not purport to address all the safety problems associated with its use. It is
the responsibility of the user of this standard to establish safety and health practices and determine the
applicability of regulatory limitations prior to use.
1 Scope
This International Standard specifies the reference method for the determination of the fat content of all types of
evaporated milk and sweetened condensed milk (liquid sweetened and unsweetened concentrated milk).
2 Normative reference
The following normative document contain provisions which, through reference in this text, constitute provisions of
this International Standard. For dated references, subsequent amendments to, or revisions of, this publication do
not apply. However, parties to agreement based on this International Standard are encouraged to investigate the
possibility of applying the most recent edition of the standard indicated below. For undated references, the latest
edition of the normative document referred to applies. Members of ISO and IEC maintain registers of currently valid
International Standards.
ISO 3889, Milk and milk products — Determination of fat content — Mojonnier-type fat extraction flasks.
3 Term and definition
For the purposes of this International Standard the following term and definition apply.
3.1
fat content of evaporated milk and sweetened condensed milk
mass fraction of substances determined by the procedure specified in this International Standard
NOTE The fat content is expressed as a mass fraction, in percent [formerly given as % (m/m)].
4 Principle
An ammoniacal ethanolic solution of a test portion is extracted with diethyl ether and light petroleum. The solvents
are removed by distillation or evaporation. The mass of the substances extracted is determined.
NOTE This is usually known as the Röse-Gottlieb principle.
1

---------------------- Page: 9 ----------------------

SIST EN ISO 1737:2000
©
ISO 1737:1999(E) ISO
5 Reagents
Use only reagents of recognized analytical grade, unless otherwise specified, and distilled or demineralized water or
water of equivalent purity.
The reagents shall leave no appreciable residue when the determination is carried out by the method specified (see
9.2.2).
5.1  Ammonia solution, containing a mass fraction of NH of approximately 25 % (r = 910 g/l).
3 20

NOTE If ammonia solution of this concentration is not available, a more concentrated solution of known concentration may
be used (see 9.4.2).
5.2  Ethanol (C H OH), or ethanol denatured by methanol, containing a volume fraction of ethanol of at least 94 %.
2 5
(See A.5.)
5.3  Congo red solution
Dissolve 1 g of Congo red in water in a 100 ml one-mark volumetric flask (6.14). Dilute to the mark with water.
NOTE The use of this solution, which allows the interface between the solvent and aqueous layers to be seen more
clearly, is optional (see 9.4.3). Other aqueous colour solutions may be used provided that they do not affect the result of the
determination.
5.4  Diethyl ether (C H OC H ), free from peroxides (see A.3), containing no more than 2 mg/kg of antioxidants,
2 5 2 5
and complying with the requirements for the blank test (see 9.2.2, A.1 and A.4).
NOTE The use of diethyl ether could lead to hazardous situations. Due to expected changes in safety regulations studies
are ongoing to replace diethyl ether by another reagent provided that it does not affect the end result of the determination.
5.5  Light petroleum, with any boiling range between 30 °C and 60 °C or, as equivalent, pentane (CH [CH ] CH )
3 2 3 3
with a boiling point of 36 °C and complying with the requirements for the blank test (see 9.2.2, A.1 and A.4).
NOTE The use of pentane is recommended because of its higher purity and constant quality.
5.6  Mixed solvent
Shortly before use, mix equal volumes of diethyl ether (5.4) and light petroleum (5.5).
6 Apparatus
WARNING — Since the determination involves the use of volatile flammable solvents, all electrical
apparatus employed shall comply with legislation relating to the hazards in using such solvents.
Usual laboratory equipment and, in particular, the following.
6.1  Analytical balance, capable of weighing to the nearest 1 mg, with a readability of 0,1 mg.
6.2  Centrifuge, capable of holding the fat-extraction flasks or tubes (6.6) and capable of spinning at a rotational
–1 –1
frequency of 500 min to 600 min to produce a radial acceleration of 80 g to 90 g at the outer end of the flasks or
tubes.
NOTE The use of the centrifuge is optional but recommended (see 9.4.6).
, for distilling the solvents and ethanol from the boiling or conical flasks,
6.3 Distillation or evaporation apparatus
or evaporating from beakers and dishes (see 9.4.13) at a temperature not exceeding 100 °C.
6.4  Drying oven, electrically heated, with ventilation port(s) fully open, capable of being maintained at a
temperature of 102 °C ± 2 °C throughout its working space.
The oven shall be fitted with a suitable thermometer.
2

---------------------- Page: 10 ----------------------

SIST EN ISO 1737:2000
©
ISO ISO 1737:1999(E)
6.5  Water baths, capable of being maintained at a temperature of between 30 °C and 40 °C, and 40 °C and 60 °C.
6.6  Mojonnier-type fat-extraction flasks, as specified in ISO 3889.
NOTE It is also possible to use fat-extraction tubes, with siphon or wash-bottle fittings, but then the procedure is different.
The alternative procedure is given in annex B.
The fat-extraction flasks shall be provided with good quality bark corks or stoppers of other material [e.g. silicone
rubber or polytetrafluoroethylene (PTFE)] unaffected by the reagents used. Bark corks shall be extracted with the
diethyl ether (5.4), kept in water at a temperature of 60 °C or more for at least 15 min, and shall then be allowed to
cool in the water so that they are saturated when used.
6.7  Rack, for holding the fat-extraction flasks (or tubes) (6.6).
6.8  Wash bottle, suitable for use with the mixed solvent (5.6).
A plastics wash bottle shall not be used.
6.9  Fat-collecting vessels, such as boiling flasks (flat-bottomed), of capacities 125 ml to 250 ml, conical flasks, of
capacity 250 ml, or metal dishes.
If metal dishes are used, they shall be of stainless steel, flat-bottomed with a diameter of 80 mm to 100 mm and a
height of approximately 50 mm.
6.10  Boiling aids, fat-free, of non-porous porcelain or silicon carbide (optional when metal dishes are used).
6.11  Measuring cylinders, of capacities 5 ml and 25 ml.
6.12  Pipettes, graduated, of capacity 10 ml.
6.13  Tongs, made of metal, for holding flasks, beakers or dishes.
6.14  Volumetric flask, one-mark, of capacity 100 ml.
7 Sampling
Sampling is not part of the method specified in this International Standard. A recommended sampling method is
given in ISO 707.
It is important that the laboratory receive a sample which is truly representative and has not been damaged or
changed during transport or storage.
Store the samples at a temperature of between 2 °C and 6 °C from the time of sampling to the time of commencing
the procedure. In the case of samples in sealed cans, store the closed cans at a temperature below 20 °C.
8 Preparation of test sample
8.1 Evaporated milk
Shake and invert the sample container. Open the sample container and pour the sample slowly into a second
sample container (provided with an airtight lid). Mix by repeated transfer, taking care to incorporate in the sample
any fat or other constituent adhering to the wall and ends of the first container. Finally, transfer the product as
completely as possible to the second container.
3

---------------------- Page: 11 ----------------------

SIST EN ISO 1737:2000
©
ISO 1737:1999(E) ISO
If necessary in the case of samples in sealed cans, condition the unopened container in the water bath (6.5) set at a
temperature of between 40 °C and 60 °C. Remove and shake the can vigorously every 15 min. After 2 h, remove
the can and allow it to cool to room temperature.
Remove the lid entirely and thoroughly mix the sample by stirring with a spoon or spatula. (If fat separates, do not
test the sample.)
8.2 Sweetened condensed milk
Open the sample container and mix thoroughly with a spoon or spatula. Use an up-and-down rotary movement in
such a way that the top layers and the content of the lower corners of the container are moved and mixed. Take
care to incorporate in the sample any milk adhering to the wall and ends of the container. Transfer the sample as
completely as possible to a second sample container (provided with an airtight lid). Close the second container.
If necessary, in the case of samples in sealed cans, condition the unopened can in the water bath (6.5) at a
temperature of between 30 °C and 40 °C. Open the can, scrape out all milk adhering to the interior of the can,
transfer to a dish large enough to permit stirring thoroughly and mix until the whole mass is homogeneous.
In the case of a sample in a collapsible tube, open the tube and transfer the contents to a jar. Then cut open the
tube and scrape out all material adhering to the interior and add to the contents of the jar.
9 Procedure
NOTE An alternative procedure using fat-extraction tubes with siphon or wash-bottle fittings (see note in 6.6) is given in
annex B.
9.1 Test portion
Mix the test sample (clause 8), by stirring in the case of sweetened condensed milk, or by gently inverting the bottle
three or four times in the case of evaporated milk. Immediately weigh to the nearest 1 mg, directly or by difference,
4 g or 5 g of the test sample of evaporated milk, or 2,0 g to 2,5 g of the test sample of sweetened condensed milk in
a fat-extraction flask (6.6).
Transfer the test portion as completely as possible into the lower (small) bulb of the fat-extraction flask.
9.2 Blank tests
9.2.1 Blank test for method
Carry out a blank test simultaneously with the determination using the same procedure and same reagents, but
replacing the test portion by 10 ml of water (see A.2).
If the value obtained in the blank test regularly exceeds 1,0 mg, check the reagents if this has not been recently
done (9.2.2). Corrections of more than 2,5 mg should be mentioned in the test report.
9.2.2 Blank test for reagents
To test the quality of the reagents, carry out a blank test as specified in 9.2.1. Additionally use an empty fat-
collecting vessel, prepared as specified in 9.3, for mass control purposes. The reagents shall leave no residue
greater than 1,0 mg (see A.1).
If the residue of the complete reagent blank test is greater than 1,0 mg, determine the residue of the solvents
separately by distilling 100 ml of the diethyl ether (5.4) and light petroleum (5.5), respectively. Use an empty fat-
collecting vessel, prepared for control purposes as described above, to obtain the real mass of residue which shall
not exceed 1,0 mg.
Very occasionally, the solvents may contain volatile matter which is strongly retained in fat. If there are indications of
the presence of such substances, carry out blank tests on all the reagents and for each solvent using a fat-
4

---------------------- Page: 12 ----------------------

SIST EN ISO 1737:2000
©
ISO ISO 1737:1999(E)
collecting vessel with about 1 g of anhydrous butterfat. If necessary, redistil solvents in the presence of 1 g of
anhydrous butterfat per 100 ml of solvent. Use the solvents only shortly after the redistillation.
Replace unsatisfactory reagents, solvents, or redistil solvents.
9.3 Preparation of fat-collecting vessel
Dry a fat-collecting vessel (6.9) with a few boiling aids (6.10) in the oven (6.4) set at 102 °C for 1 h.
NOTE 1 Boiling aids are desirable to promote gentle boiling during the subsequent removal of solvents, especially when
using glass fat-collecting vessels; their use is optional with metal dishes.
Protect the fat-collecting vessel from dust and allow it to cool to the temperature of the weighing room (glass fat-
collecting vessel for at least 1 h, metal dish for at least 30 min).
NOTE 2 To avoid insufficient cooling or unduly long cooling times, the fat-collecting vessel should not be placed in a
desiccator.
Use tongs to place the fat-collecting vessel on the balance. Weigh the fat-collecting vessel to the nearest 1,0 mg.
NOTE 3 Tongs should preferably be used to avoid, in particular, temperature variations.
9.4 Determination
9.4.1  Carry out the determination without delay.
Add water at a temperature of about 50 °C to the test portion in the fat-extraction flask (9.1) to obtain a total volume
of 10 ml to 11 ml. Use the water to wash the test portion on to the bottom of the flask. Shake gently with slight
warming at about 50 °C in the waterbath (6.5) until the test portion is completely dispersed. Cool in running water to
room temperature.
9.4.2  Add 2 ml of ammonia solution (5.1) to the dispersed test portion in the fat-extraction flask (9.4.1), or a
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.