Sanitary tapware - Mechanical mixing valves (PN 10) - General technical specifications

This document specifies:
a)   the field of application for mechanical mixing valves for use in a supply system of Type 1 (see Figure 1);
b)   the dimensional, leaktightness, pressure resistance, hydraulic performance, mechanical strength, endurance, corrosion resistance of the surface of the product, sequence of testing and acoustic characteristics with which sanitary tapware products including their components (flexible hose, pull out spray) need to comply where applicable;
c)   test methods to verify the characteristics.
The tests described in this document are type tests (laboratory tests) and not quality control or factory production control (FPC) tests carried out during manufacture.
This document applies to draw-off taps (mechanical mixing valves) for use with sanitary appliances installed in rooms used for personal hygiene (cloakrooms, bathrooms, etc.) and for food preparation (kitchens), i.e. for use with baths, wash basins, bidets, showers and sinks.
The conditions of use and classifications are given in Table 1.
[Table 1]
Figure 1 shows a supply system of Type 1 with a pressure range of (0,05 to 1,0) MPa [(0,5 to 10) bar].
[Figure 1]
Final materials included in the product are not covered by this document.

Sanitärarmaturen - Mechanisch einstellbare Mischer (PN 10) - Allgemeine technische Spezifikation

Dieses Dokument legt Folgendes fest:
a)   den Anwendungsbereich für mechanische Mischventile für die Anwendung in Wasserversorgungsanlagen des Typs 1 (siehe Bild 1);
b)   die Abmessungen, die Dichtheit, die Festigkeit unter Innendruck, die hydraulischen Eigenschaften, die mechanische Festigkeit, die Dauerhaftigkeit, die Korrosionsbeständigkeit der Oberfläche des Produkts, die Reihenfolge der Prüfungen und das Geräuschverhalten, denen Sanitärarmaturen einschließlich ihrer Bestandteile (flexibler Schlauch, ausziehbarer Brause), sofern zutreffend, entsprechen müssen;
c)   die Prüfverfahren, um diese Anforderungen nachzuweisen.
Die in diesem Dokument beschriebenen Prüfungen sind Typ-Anerkennungsprüfungen (Laborprüfungen) und keine Qualitätskontroll- oder werksseitigen Fertigungsprüfungen (en: factory production control, FPC), die während der Herstellung durchgeführt werden.
Dieses Dokument gilt für Entnahmearmaturen (mechanisch einstellbare Mischer) zur Verwendung mit Sanitärausstattungsgegenständen, die in den der Hygiene dienenden Räumen (Toiletten, Bäder usw.) und zur Lebensmittelzubereitung (in Küchen) installiert werden, d. h. für Wannen, Waschbecken, Sitzwaschbecken, Duschen und Spülbecken.
Die Anwendungsbedingungen und Klassifizierungen sind in Tabelle 1 dargestellt.
Tabelle 1 - Anwendungsbedingungen
Bild 1 zeigt ein Wasserversorgungssystem vom Typ 1 mit einem Druckbereich von (0,05 bis 1,0) MPa [(0,5 bis 10) bar].
Bild 1 - Versorgungsanlage des Typs 1 mit einem Druckbereich von (0,05 bis 1,0) MPa [(0,5 bar bis 10) bar]
Endstoffe, die Teil des Produkts sind, werden nicht von diesem Dokument abgedeckt.

Robinetterie sanitaire - Mitigeurs mécaniques (PN 10) - Spécifications techniques générales

Le présent document spécifie :
a)   le champ d’application des mitigeurs mécaniques destinés à être utilisés dans un système d’alimentation de type 1 (voir Figure 1) ;
b)   les caractéristiques dimensionnelles, d’étanchéité, de résistance à la pression, de performance hydraulique, de résistance mécanique, d’endurance, de résistance à la corrosion de la surface du produit, de séquence d’essais et d’acoustique auxquelles les produits de robinetterie sanitaire, y compris leurs composants (tuyau flexible, douchette extractible), doivent répondre, le cas échéant ;
c)   les méthodes d’essai permettant de vérifier ces caractéristiques.
Les essais décrits dans le présent document sont des essais de type (essais en laboratoire) et non des essais de contrôle qualité ou de contrôle de la production en usine (FPC, factory production control) réalisés en cours de fabrication.
Le présent document s’applique aux robinets de puisage (mitigeurs mécaniques) destinés à équiper les appareils sanitaires installés dans les locaux d’hygiène personnelle (toilettes, salles de bain, etc.) et dans les cuisines, c’est-à-dire les baignoires, lavabos, bidets, douches et éviers.
Les conditions d’utilisation et la classification sont données dans le Tableau 1.
[Tableau 1]
La Figure 1 représente un système d’alimentation de type 1 dans une plage de pression de (0,05 à 1,0) MPa [de (0,5 à 10) bar].
[Figure 1]
Les matériaux finaux inclus dans le produit ne sont pas couverts par le présent document.

Sanitarne armature - Mehanski mešalni ventili (PN 10) - Splošne tehnične zahteve

General Information

Status
Published
Publication Date
24-Sep-2024
Current Stage
6060 - Definitive text made available (DAV) - Publishing
Start Date
25-Sep-2024
Due Date
22-Dec-2023
Completion Date
25-Sep-2024

Relations

Buy Standard

Standard
EN 817:2024
English language
53 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-december-2024
Sanitarne armature - Mehanski mešalni ventili (PN 10) - Splošne tehnične zahteve
Sanitary tapware - Mechanical mixing valves (PN 10) - General technical specifications
Sanitärarmaturen - Mechanisch einstellbare Mischer (PN 10) - Allgemeine technische
Spezifikation
Robinetterie sanitaire - Mitigeurs mécaniques (PN 10) - Spécifications techniques
générales
Ta slovenski standard je istoveten z: EN 817:2024
ICS:
91.140.70 Sanitarne naprave Sanitary installations
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EN 817
EUROPEAN STANDARD
NORME EUROPÉENNE
September 2024
EUROPÄISCHE NORM
ICS 91.140.70 Supersedes EN 817:2008
English Version
Sanitary tapware - Mechanical mixing valves (PN 10) -
General technical specifications
Robinetterie sanitaire - Mitigeurs mécaniques (PN 10) Sanitärarmaturen - Mechanisch einstellbare Mischer
- Spécifications techniques générales (PN 10) - Allgemeine technische Spezifikation
This European Standard was approved by CEN on 21 July 2024.

CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this
European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references
concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN
member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by
translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management
Centre has the same status as the official versions.

CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway,
Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Türkiye and
United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION

EUROPÄISCHES KOMITEE FÜR NORMUNG

CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2024 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 817:2024 E
worldwide for CEN national Members.

Contents Page
European foreword . 5
Introduction . 6
1 Scope . 7
2 Normative references . 8
3 Terms and definitions . 9
4 Designation . 11
5 Marking and identification . 12
5.1 Marking . 12
5.2 Identification . 12
6 Materials . 13
6.1 Chemical and hygiene requirements . 13
6.2 Exposed surface condition and quality of coating . 13
7 Backflow protection . 13
8 Sequence of testing . 13
9 Dimensional characteristics . 13
9.1 General remarks . 13
9.2 Inlet dimensions . 14
9.3 Outlet dimensions . 15
9.4 Mounting dimensions . 18
9.5 Special cases . 19
10 Leaktightness characteristics . 19
10.1 Principle . 19
10.2 Apparatus . 20
10.3 Leaktightness of the obturator and of the tap upstream of the obturator(s) with the
obturator in the closed position . 20
10.4 Leaktightness downstream of the obturator . 20
10.5 Leaktightness of manually operated diverters . 21
10.6 Leaktightness and operation of diverters with automatic return (and semi-
automatic type diverters) . 22
10.7 Cross flow between inlets . 23
11 Pressure resistance . 24
11.1 Principle . 24
11.2 Apparatus . 24
11.3 Mechanical behaviour upstream of the obturator – obturator in the closed position . 24
11.4 Mechanical behaviour downstream of the obturator – obturator in the open position . 25
12 Hydraulic Performance . 25
12.1 General. 25
12.2 Initial setting . 26
12.3 Determination of flow rate . 26
12.4 Determination of sensitivity . 27
13 Mechanical strength/torsional resistance . 29
13.1 Principle . 29
13.2 Apparatus . 29
13.3 Procedure . 29
13.4 Requirements . 30
14 Mechanical endurance . 30
14.1 General . 30
14.2 Endurance test of conventional control devices . 30
14.3 Endurance test of joystick control devices . 32
14.4 Endurance test of Single sequential control devices . 34
14.5 Endurance test of separate controls . 36
14.6 Endurance test of diverter mechanisms . 38
14.7 Endurance test for swivel spouts . 40
15 Acoustic characteristics . 41
15.1 General . 41
15.2 Procedure . 42
15.3 Expression of results . 42
Annex A (normative) Apparatus. 44
A.1 General . 44
A.2 Supply circuits . 44
A.3 Test circuit . 45
A.4 Pressure take off tees . 47
A.5 Mounting of the mixing valve . 47
Annex B (informative) Pressure take-off tee . 48
Annex C (informative) Recommended flow rates . 51
Annex D (informative) Product components (detailed by other standards) . 52
Bibliography . 53

Figures
Figure 1 — Supply system of Type 1 with a pressure range of (0,05 to 1,0) MPa [(0,5 to 10) bar] . 8
Figure 2 — single hole taps. 15
Figure 3 — Multi hole taps . 15
Figure 4 — Remote outlet . 16
Figure 5 — Single hole/remote outlet . 17
Figure 6 — Bath/shower /remote outlet. 17
Figure 7 — Single hole taps . 19
Figure 8 — Clamping Arrangement for use with ceramic sanitaryware . 19
Figure 9 — Sensitivity curve . 28
Figure 10 — Radius (r) for the determination of sensitivity .
...

Questions, Comments and Discussion