Laboratory measurement of walking noise on floors

This European Standard specifies a laboratory measurement method to determine noise radiated from a floor covering on a standard concrete floor when excited by a standard tapping machine.

Messung von Gehschall auf Fußböden im Prüfstand

Mesurage en laboratoire du bruit des pas sur les planchers

Laboratorijsko merjenje hrupa pri hoji po podu

Ta evropski standard določa metodo z laboratorijskim merjenjem za določevanje hrupa, ki prihaja iz talne obloge na standardnih betonskih tleh ob uporabi standardnega stopalnega stroja.

General Information

Status
Withdrawn
Publication Date
20-Mar-2018
Withdrawal Date
24-Nov-2020
Current Stage
9960 - Withdrawal effective - Withdrawal
Completion Date
25-Nov-2020

Relations

Buy Standard

Standard
EN 16205:2013+A1:2018
English language
18 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Laboratorijsko merjenje hrupa pri hoji po poduMessung von Gehschall auf Fußböden im PrüfstandMesurage en laboratoire du bruit des pas sur les planchersLaboratory measurement of walking noise on floors91.120.20L]RODFLMDAcoustics in building. Sound insulation91.060.30Stropi. Tla. StopniceCeilings. Floors. Stairs17.140.01Acoustic measurements and noise abatement in generalICS:Ta slovenski standard je istoveten z:EN 16205:2013+A1:2018SIST EN 16205:2013+A1:2018en,fr,de01-junij-2018SIST EN 16205:2013+A1:2018SLOVENSKI
STANDARDSIST EN 16205:20131DGRPHãþD

EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 16205:2013+A1
March
t r s z ICS
{ sä s t rä t r English Version
Laboratory measurement of walking noise on floors Mesurage en laboratoire du bruit des pas sur les planchers
Messung von Gehschall auf Fußböden im Prüfstand This European Standard was approved by CEN on
s May
t r s u and includes Amendment
s approved by CEN on
s t February
t r s zä
egulations which stipulate the conditions for giving this European Standard the status of a national standard without any alterationä Upætoædate lists and bibliographical references concerning such national standards may be obtained on application to the CENæCENELEC Management Centre or to any CEN memberä
translation under the responsibility of a CEN member into its own language and notified to the CENæCENELEC Management Centre has the same status as the official versionsä
CEN members are the national standards bodies of Austriaá Belgiumá Bulgariaá Croatiaá Cyprusá Czech Republicá Denmarká Estoniaá Finlandá Former Yugoslav Republic of Macedoniaá Franceá Germanyá Greeceá Hungaryá Icelandá Irelandá Italyá Latviaá Lithuaniaá Luxembourgá Maltaá Netherlandsá Norwayá Polandá Portugalá Romaniaá Serbiaá Slovakiaá Sloveniaá Spainá Swedená Switzerlandá Turkey and United Kingdomä
EUROPEAN COMMITTEE FOR STANDARDIZATION COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre:
Rue de la Science 23,
B-1040 Brussels
t r s z CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Membersä Refä Noä EN
s x t r wã t r s u ªA sã t r s z ESIST EN 16205:2013+A1:2018

Presentation of the walking noise spectrum with uncertainty bars (example) . 11 Annex B (normative)
Reference spectrum for laboratory bare floors . 12 Annex C (informative)
Fixing the pads below the tapping machine . 13 Annex D (informative)
Background of the measuring method . 14 !Annex E (informative)"
Calculation of perceived walking loudness on floor coverings installed floating . 16 E.1 General . 16 E.2 Data measured . 16 E.3 Calculations . 16 E.3.1 Sound spectrum Li,loud . 16 E.3.2 Loudness RWS . 16 E.4 Test report . 17 Bibliography . 18
Critical bandwidth differs within the frequency range. Note 2 to entry:
The critical band produces the critical band scale. Its unit is Bark." 4 Principle A floor test facility according to EN ISO 10140 for impact and airborne sound measurements is used. It consists of two medium sized and medium damped rooms above each other, separated by a standard homogeneous concrete floor. As a walking noise source, a standard tapping machine according to EN ISO 10140 is applied. Several average sound pressure level measurements in third-octave bands are made in the upper and lower rooms with the bare floor either uncovered or covered with pads or sufficiently large "full-size" specimens of the tested flooring. In the upper room the reverberation times with large specimens and with merely pads present shall be determin
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.