Medical electrical equipment - Part 2-10: Particular requirements for the safety of nerve and muscle stimulators

EN following parallel vote

Medizinische elektrische Geräte - Teil 2-10: Besondere Festlegungen für die Sicherheit von Geräten zur Stimulation von Nerven und Muskeln

Appareils électromédicaux - Partie 2-10: Règles particulières de sécurité pour stimulateurs de nerfs et de muscles

Medicinska električna oprema - 2-10. del: Posebne varnostne zahteve za živčne in mišične stimulatorje - Dopolnilo A1 (IEC 60601-2-10:1987/A1:2001)

General Information

Status
Withdrawn
Publication Date
08-Nov-2001
Withdrawal Date
31-Oct-2004
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
22-May-2018
Completion Date
22-May-2018

Relations

Buy Standard

Amendment
EN 60601-2-10:2002/A1:2002
English language
12 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 60601-2-10:2002/A1:2002
01-junij-2002
0HGLFLQVNDHOHNWULþQDRSUHPDGHO3RVHEQHYDUQRVWQH]DKWHYH]DåLYþQHLQ
PLãLþQHVWLPXODWRUMH'RSROQLOR$ ,(&$
Medical electrical equipment - Part 2-10: Particular requirements for the safety of nerve
and muscle stimulators (IEC 60601-2-10:1987/A1:2001)
Medizinische elektrische Geräte - Teil 2-10: Besondere Festlegungen für die Sicherheit
von Geräten zur Stimulation von Nerven und Muskeln (IEC 60601-2-10:1987/A1:2001)
Appareils électromédicaux - Partie 2-10: Règles particulières de sécurité pour
stimulateurs de nerfs et de muscles (CEI 60601-2-10:1987/A1:2001)
Ta slovenski standard je istoveten z: EN 60601-2-10:2000/A1:2001
ICS:
11.040.60 Terapevtska oprema Therapy equipment
SIST EN 60601-2-10:2002/A1:2002 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 60601-2-10:2002/A1:2002

---------------------- Page: 2 ----------------------

SIST EN 60601-2-10:2002/A1:2002
EUROPEAN STANDARD EN 60601-2-10/A1
NORME EUROPÉENNE
EUROPÄISCHE NORM November 2001
ICS 11.040.60
English version
Medical electrical equipment
Part 2-10: Particular requirements for the safety
of nerve and muscle stimulators
(IEC 60601-2-10:1987/A1:2001)
Appareils électromédicaux Medizinische elektrische Geräte
Partie 2-10: Règles particulières Teil 2-10: Besondere Festlegungen
de sécurité pour stimulateurs für die Sicherheit von Geräten
de nerfs et de muscles zur Stimulation von Nerven und Muskeln
(CEI 60601-2-10:1987/A1:2001) (IEC 60601-2-10:1987/A1:2001)
This amendment A1 modifies the European Standard EN 60601-2-10:2000; it was approved by
CENELEC on 2001-11-01. CENELEC members are bound to comply with the CEN/CENELEC Internal
Regulations which stipulate the conditions for giving this amendment the status of a national standard without
any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.
This amendment exists in three official versions (English, French, German). A version in any other language
made by translation under the responsibility of a CENELEC member into its own language and notified to the
Central Secretariat has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Czech Republic,
Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands,
Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom.
CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
Central Secretariat: rue de Stassart 35, B - 1050 Brussels
© 2001 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 60601-2-10:2000/A1:2001 E

---------------------- Page: 3 ----------------------

SIST EN 60601-2-10:2002/A1:2002
EN 60601-2-10:2000/A1:2001 - 2 -
Foreword
The text of document 62D/413/FDIS, future amendment 1 to IEC 60601-2-10:1987, prepared by
1)
SC 62D , Electromedical equipment, of IEC TC 62, Electrical equipment in medical practice, was
submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as amendment A1 to
EN 60601-2-10:2000 on 2001-11-01.
The following dates were fixed:
– latest date by which the amendment has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2002-08-01
– latest date by which the national standards conflicting
with the amendment have to be withdrawn (dow) 2004-11-01
__________
Endorsement notice
The text of amendment 1:2001 to the International Standard IEC 60601-2-10:1987 was approved by
CENELEC as an amendment to the European Standard without any modification.
__________

1
)
The foreword of EN 60601-2-10:2000 mistakenly indicated SC 62C as the technical body that drafted the text of
 the International Standard.

---------------------- Page: 4 ----------------------

SIST EN 60601-2-10:2002/A1:2002
INTERNATIONAL IEC
STANDARD
60601-2-10
1987
AMENDMENT 1
2001-09
Amendment 1
Medical electrical equipment –
Part 2-10:
Particular requirements for the safety
of nerve and muscle stimulators
Amendement 1
Appareils électromédicaux –
Partie 2-10:
Règles particulières de sécurité
pour stimulateurs de nerfs et de muscles
 IEC 2001  Copyright - all rights reserved
International Electrotechnical Commission 3, rue de Varembé Geneva, Switzerland
Telefax: +41 22 919 0300 e-mail: inmail@iec.ch IEC web site http://www.iec.ch
Commission Electrotechnique Internationale
PRICE CODE
J
International Electrotechnical Commission
For price, see current catalogue

------------------
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.