Railway applications - Railway rolling stock cables having special fire performance - Standard wall - Part 2: Single core cables

Superseded by EN 50264-2-1:2008

Bahnanwendungen - Kabel und Leitungen für Schienenfahrzeuge mit verbessertem Verhalten im Brandfall - Standard Isolierwanddicken - Teil 2: Einadrige Leitungen

Applications ferroviaires - Câbles pour matériel roulant ferroviaire ayant des performances particulières de comportement au feu - Câbles à isolation d'épaisseur normale - Partie 2: Câbles à un conducteur

Railway applications - Railway rolling stock cables having special fire performance - Standard wall - Part 2: Single core cables

General Information

Status
Withdrawn
Publication Date
22-Aug-2002
Withdrawal Date
30-Jun-2008
Technical Committee
Drafting Committee
Parallel Committee
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
01-Mar-2011
Completion Date
01-Mar-2011

Relations

Buy Standard

Standard
EN 50264-2:2003
English language
26 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-februar-2003
Railway applications - Railway rolling stock cables having special fire performance
- Standard wall - Part 2: Single core cables
Railway applications - Railway rolling stock cables having special fire performance -
Standard wall -- Part 2: Single core cables
Bahnanwendungen - Kabel und Leitungen für Schienenfahrzeuge mit verbessertem
Verhalten im Brandfall - Standard Isolierwanddicken -- Teil 2: Einadrige Leitungen
Applications ferroviaires - Câbles pour matériel roulant ferroviaire ayant des
performances particulières de comportement au feu - Câbles à isolation d'épaisseur
normale -- Partie 2: Câbles à un conducteur
Ta slovenski standard je istoveten z: EN 50264-2:2002
ICS:
13.220.20 3RåDUQD]DãþLWD Fire protection
29.060.20 Kabli Cables
45.060.01 Železniška vozila na splošno Railway rolling stock in
general
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD EN 50264-2
NORME EUROPÉENNE
EUROPÄISCHE NORM August 2002
ICS 13.220.20; 29.060.20; 45.060.01
English version
Railway applications -
Railway rolling stock cables having special fire performance -
Standard wall
Part 2: Single core cables
Applications ferroviaires - Bahnanwendungen -
Câbles pour matériel roulant ferroviaire Kabel und Leitungen für Schienen-
ayant des performances particulières fahrzeuge mit verbessertem Verhalten
de comportement au feu - im Brandfall -
Câbles à isolation d'épaisseur normale Standard Isolierwanddicken
Partie 2: Câbles à un conducteur Teil 2: Einadrige Leitungen
This European Standard was approved by CENELEC on 2002-03-01. CENELEC members are bound to
comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this
European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any
other language made by translation under the responsibility of a CENELEC member into its own
language and notified to the Central Secretariat has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Czech Republic,
Denmark, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Luxembourg, Malta,
Netherlands, Norway, Portugal, Slovakia, Spain, Sweden, Switzerland and United Kingdom.
CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
Central Secretariat: rue de Stassart 35, B - 1050 Brussels
© 2002 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 50264-2:2002 E
Foreword
This European Standard was prepared for Technical Committee CENELEC TC 20 “Electric
cables” by Working Group 12 “Railway cables” as part of the overall programme of work in
CENELEC TC 9X “Electrical and electronic applications for railways”.
The text of the draft was submitted to the formal vote and was approved by CENELEC as
EN 50264-2 on 2002-03-01.
The following dates were fixed:
- latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2003-07-01
- latest date by which the national standards conflicting
with the EN have to be withdrawn (dow) 2008-07-01
Annexes designated ”normative” are part of the body of the standard.
Annexes designated “informative” are given for information only.
In this standard, annexes A and B are normative and annex C is informative.

- 3 - EN 50264-2:2002
Contents
Page
Introduction .4
1 Scope.5
2 Normative references.5
3 Definitions .6
4 Rated voltage.7
5 Designation, marking and coding.7
6 Construction of cables .8
7 Tests .13
Annex A (normative) Thickness and overall diameter .22
Annex B (normative) Preparation of test pieces for physical tests .24
Annex C (informative) Guidance on selection of cables for type approval.25
Bibliography .26
Table 1 - General data - Cable type (0,6/1 kV unsheathed).11
Table 2 - General data - Cable type (1,8/3 kV unsheathed).12
Table 3 - General data - Cable type (1,8/3 kV sheathed).12
Table 4 - General data - Cable type (3,6/6 Kv sheathed).13
Table 5 - Schedule of tests for cables.20

Introduction
EN 50264 covers a range of cables with standard wall thickness of insulation, both
sheathed and unsheathed, based upon halogen free materials, for use in railway rolling
stock. It is divided into 3 parts:
Part 1: General requirements;
Part 2: Single core cables;
Part 3: Multicore cables.
Special test methods referred to in EN 50264 are given in EN 50305. A guide to use is
given in (EN 50355 – under development).
The cables in part 2 may also be used in part 3 of this series of standards to build up
multicore sheathed cables.
Part 1, General requirements, contains a more extensive introduction to EN 50264, and
should be read in conjunction with this part 2.

- 5 - EN 50264-2:2002
1 Scope
Part 2 of EN 50264 specifies requirements for, and constructions and dimensions of, single
core cables of the following types and voltage ratings:
2 2
- 0,6/1 kV unscreened, unsheathed (1 mm to 400 mm );
2 2
- 1,8/3 kV unscreened, unsheathed (1,5 mm to 400 mm );
2 2
- 1,8/3 kV unscreened, sheathed (1,5 mm to 400 mm );
2 2
- 3,6/6 kV unscreened, sheathed (2,5 mm to 400 mm ).
All cables have class 5 tinned copper conductors to HD 383, halogen-free insulation and,
where applicable, halogen-free sheath. They are for use in railway rolling stock as fixed
wiring, or wiring where limited flexing in operation is encountered. The requirements provide
for a continuous conductor temperature not exceeding 90 °C and a maximum temperature
for short circuit conditions of 200 °C based on a duration of 5 seconds.
Under fire conditions the cables exhibit special performance characteristics in respect of
maximum permissible flame propagation (flame spread) and maximum permissible emission
of smoke and toxic gases. These requirements are specified to permit the cables to satisfy
hazard levels 2, 3 or 4 of EN 45545-1.
NOTE 1  Requirements for the emission of smoke, fumes and gases are not specified for Hazard Level 1 of
EN 45545-1.
NOTE 2  EN 45545-1 is still under development and should be consulted.
Part 2 of EN 50264 should be used in conjunction with part 1 “General requirements”.
2 Normative references
This European Standard incorporates by dated or undated reference, provisions from other
publications. These normative references are cited at the appropriate places in the text and
the publications are listed hereafter. For dated references, subsequent amendments to or
revisions of these references apply to this European Standard only when incorporated in it
by amendment or revision. For undated references the latest edition of the publication
referred to applies.
EN 10002-1 Tensile testing of metallic materials - method of test at ambient
temperature
1)
EN 45545-1 Railway applications - Fire protection on railway vehicles -
Part 1: General
EN 50264-1 Railway applications - Railway rolling stock cables having special fire
performance - Standard wall - Part 1: General Requirements
EN 50264-3 Railway applications - Railway rolling stock cables having special fire
performance - Standard wall - Part 3: Multicore cables

1)
at draft stage.
EN 50265-2-1 Common test methods for cables under fire conditions - Test for
resistance to vertical flame propagation for a single insulated conductor
or cable - Part 2-1: Procedures - 1kW pre-mixed flame
EN 50266-2-4 Common test methods for cables under fire conditions - Test for vertical
flame spread of vertically-mounted bunched wires or cables -
Part 2-4: Procedures - Category C
EN 50267-2-1 Common test methods for cables under fire conditions - Tests on gases
evolved during combustion of materials from cables -
Part 2-1: Procedures – Determination of the amount of halogen acid
gas
EN 50267-2-2 Common test methods for cables under fire conditions - Tests on gases
evolved during combustion of materials from cables -
Part 2-2: Procedures - Determination of degree of acidity of gases for
materials by measuring pH and conductivity
EN 50268-2 Common test methods for cables under fire conditions - Measurement
of smoke density of cables burning under defined conditions -
Part 2: Procedure
EN 50305 Railway applications - Railway rolling stock cables having special fire
performance - Test methods
EN 50334 Marking by inscription for the identification of cores of electric cables
EN 60684-2 Flexible insulating sleeving - Part 2 Methods of test
EN 60811-1-1 Insulating and sheathing materials of electric and optical cables -
Common test methods - Part 1-1: General application – Measurement
of thickness and overall dimensions - Tests for determining the
mechanical properties
EN 60811-1-2 Insulating and sheathing materials of electric cables - Common test
methods - Part 1-2: General application - Thermal ageing methods
EN 60811-1-3 Insulating and sheathing materials of electric cables – Common test
methods - Part 1-3: General application - Methods for determining the
density - Water absorption tests - Shrinkage test
EN 60811-1-4 Insulating and sheathing materials of electric cables – Common test
methods - Part 1-4: General application - Tests at low temperature
EN 60811-2-1 Insulating and sheathing materials of electric and optical cables –
Common test methods - Part 2-1: Methods specific to elastomeric
compounds - Ozone resistance, hot set and mineral oil immersion tests
HD 308 Identification of cores in cables and flexible cords
HD 383 Conductors of insulated cables - First supplement: Guide to the
dimensional limits of circular conductors
3 Definitions
For the purposes of this standard the definitions given in EN 50264-1 apply.

- 7 - EN 50264-2:2002
4 Rated voltage
The rated voltage for single-core insulated cables shall be as follows:
a) unsheathed: 0,6/1 kV; 1,8/3 kV;
b) sheathed: 1,8/3 kV; 3,6/6 kV.
5 Designation, marking and coding
5.1 Code Designation
For the purpose of supplying cables to this standard, the following code designation shall
be used:
EN reference, number of cores and conductor size, identifier for the particular hazard level
(see 5.2)
For example:
EN 50264    1 x 1,5 F
5.2 Code identities for cables suitable for use in particular hazard levels
The following letters shall be used as a code to identify the suitability of a particular cable
for use under one of the Hazard Levels of EN 45545-1, and to indicate performance levels
relating to low temperature and to oil and fuel resistance.
Hazard level EN 45545-1 HL1 HL2 or HL4
HL3
Low temperature/Oil resistance A B C
Extra low temperature/ Oil resistance D E F
Low temperature/ Extra oil and fuel resistance G H J
Extra low temperature/ Extra oil and fuel KL M
resistance
5.3 Marking of cable
Cables shall be marked with the following:
- manufacturer’s name;
- EN reference;
- voltage rating (U );
o
- conductor size;
- identifier for the particular hazard level (see 5.2).
For example:
XYZ EN 50264-2  3 600 V 400  F
The marking shall conform to the requirements of clause 5 of EN 50264-1.

5.4 Core identification
5.4.1 Single core cables
The core insulation of all cables shall be black unless otherwise specified. If a colour other
than black is specified it shall be a colour in accordance with HD 308.
The colour shall be clearly identifiable and durable. Durability shall be checked by the test
given in 10.1 of EN 50305.
Conformity with these requirements shall be verified by visual examination.
5.4.2 Multicore cables
Cores complying with EN 50264-2 may be used as components of multicore cables, e.g. in
EN 50264-3. In such cases, the identification of the individual core in a cable, except the
earthing conductor, shall be by printed number or colour.
The number shall be printed in a colour which contrasts with the core colour.
The marking by numbers shall conform to EN 50334, unless otherwise specified, and
conformity shall be by visual examination and measurement.
5.5 Sheath
The sheath shall be black unless otherwise specified.
6 Construction of cables
6.1 General
The cable shall conform to the applicable general requirements given in EN 50264-1, and to
the specific requirements of this part.
Conformity with the requirements shall be checked by inspection and by the tests given in
Table 5.
The cable dimension
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.