EN 60728-101:2017/AC:2017-07
(Corrigendum)Cable networks for television signals, sound signals and interactive services - Part 101: System performance of forward paths loaded with digital channels only
- BACK
- 06-Jul-2017
- 33.040.20
- 33.160.01
- CLC/TC 209
Cable networks for television signals, sound signals and interactive services - Part 101: System performance of forward paths loaded with digital channels only
Kabelnetze für Fernsehsignale, Tonsignale und interaktive Dienste - Teil 101: Systemanforderungen in Verteilrichtung bei kompletter digitaler Kanallast
Réseaux de distribution par câbles pour signaux de télévision, signaux de radiodiffusion sonore et services interactifs - Partie 101: Performances des systèmes de voie directe soumis à une charge de porteuses exclusivement numériques
Kabelska omrežja za televizijske in zvokovne signale ter interaktivne storitve - 101. del: Lastnosti sistema za naprejšnje poti z obremenitvami popolnoma digitaliziranih kanalov (TA/5)
General Information
Relations
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Kabelska omrežja za televizijske in zvokovne signale ter interaktivne storitve - 101. del: Lastnosti sistema za naprejšnje poti z obremenitvami popolnoma digitaliziranih kanalov (TA/5)Kabelnetze für Fernsehsignale, Tonsignale und interaktive Dienste - Teil 101: Systemanforderungen in Verteilrichtung bei kompletter digitaler KanallastRéseaux de distribution par câbles pour signaux de télévision, signaux de radiodiffusion sonore et services interactifs - Partie 101: Performances des systèmes de voie directe soumis à une charge de porteuses exclusivement numériquesCable networks for television signals, sound signals and interactive services - Part 101: System performance of forward paths loaded with digital channels only33.060.40Kabelski razdelilni sistemiCabled distribution systemsICS:Ta slovenski standard je istoveten z:EN 60728-101:2017/AC:2017-07SIS
...
This May Also Interest You
IEC 60728-101-1:2023 provides the requirements and describes the implementation guidelines of RF cabling for two-way home networks; it is applicable to any home network that distributes signals provided by CATV/MATV/SMATV cable networks (including individual receiving systems) having a coaxial cable output. It is also applicable to home networks where some part of the distribution network uses wireless links, for example in place of the receiver cord. This part of IEC 60728 is therefore applicable to RF cabling for two-way home networks with wired cords or wireless links inside a room and primarily intended for television and sound signals operating between about 5 MHz and 3 300 MHz. The frequency range is extended to 6 000 MHz for distribution techniques that replace wired cords with a wireless two-way communication inside a room (or a small number of adjacent rooms) that uses the 5 GHz to 6 GHz band. In a building divided into apartment blocks, the distribution of the signals inside the home starts from the home network interface (HNI) up to the system outlet or terminal input. The requirements at the system outlet are given in IEC 60728-101:2016, Clause 5 and the requirements at the HNI are given in IEC 60728-101:2016, Clause 7. In Clause 5 of this document, additional requirements are given. This document deals with various possibilities to distribute signals in a home network, using coaxial cables, balanced pair cables, fibre optic cables (glass or plastic) and also wireless links inside a room (or a small number of adjacent rooms) to replace wired cords. This document gives references to basic methods of measurement of the operational characteristics of the home cable network in order to assess its performance. All requirements refer to the performance limits, which are obtained between the input(s) at the home network interface (HNI) and the output at any system outlet when terminated in a resistance equal to the nominal load impedance of the system, unless otherwise specified. Where system outlets are not used, the above applies to the terminal input. The present document also provides limits for the accumulation of degradations if the home network is subdivided into a number of parts, using different transmission media (e.g. coaxial cabling, balanced cabling, optical cabling, wireless links). Clause 5 defines the performance limits measured at system outlet or terminal input for an unimpaired (ideal) test signal applied at the HNI. Under normal operating conditions for any digital channel and meeting these limits, the cumulative effect of the impairment of any single parameter at the HNI and that due to the home network produces signals not worse than the requirements given in IEC 60728-101-2. For digitally modulated signals, the quality requirement is a QEF (quasi error-free) reception. This document describes the physical layer connection for home networks. Description of protocols required for layer 2 and higher layers is out of the scope of this document. Logical connections between devices within the home network are therefore not always guaranteed. This International Standard is to be used in conjunction with IEC 60728-101:2016.
- Standard72 pagesEnglish languagesale 10% offe-Library read for×1 day
- 27-Jul-2023
- 33.040.20
- 33.160.01
- CLC/TC 209
IEC 60728-101-2:2023 provides the minimum performance requirements to be fulfilled in operation at the system outlet or terminal input and describes the summation criteria for the impairments present in the received signals and those produced by the CATV/MATV/SMATV cable network, including individual receiving systems. In a building divided into apartment blocks, the signals received by the antennas are distributed by the MATV/SMATV cable network up to the home network interface (HNI); the television signals are then distributed (inside the home) by home networks (HN) of various types up to the system outlet or terminal input. The cable network can support two-way operation, from the system outlet (or terminal input) towards the headend. The home network can use coaxial cables, balanced pair cables, fibre optic cables (glass or plastic) and also wireless links inside a room (or a small number of adjacent rooms) to replace wired cords. This part of IEC 60728 is limited to downstream TV broadcast signals received from antennas and is applicable to cable networks intended for television signals, sound signals and interactive services operating between about 5 MHz and 3 300 MHz. The frequency range is extended to 6 000 MHz for home distribution techniques that replace wired cords with a wireless two-way communication inside a room (or a small number of adjacent rooms) that uses the 5 GHz to 6 GHz frequency band. The main sections of a general CATV/MATV/SMATV system, indicating the parts of the IEC 60728-101 series documents where the relevant performance requirements are indicated. - The requirements for the signals received at the headend are given in IEC 60728-101:2016, Clause 6. - The requirements for the CATV/MATV/SMATV cable network, assuming an unimpaired input signal at the input of the headend, up to the system outlet are given in IEC 60728‑101:2016, Clause 5. - The requirements for the CATV/MATV/SMATV cable network up to the home network interface (HNI) are given in IEC 60728-101:2016, Clause 7, assuming an unimpaired input signal at the input of the headend. - The specific requirements from HNI to the system outlet or terminal input are given in IEC 60728-101-1:2023, Clause 5, assuming an unimpaired input signal at the HNI. - The requirements at the system outlet in operation are given in Clause 6 of this document. The expression "in operation" means that the received signals, with their impairments, are applied to the headend input of the CATV/MATV/SMATV cable network. The requirements at the system outlet "in operation" are derived, therefore, by summing the impairments of the various cascaded parts of the system and of the input signal. When a change of signal format from digital to digital (e.g. from QPSK to QAM) (e.g. as in ETSI EN 300 473) or from digital to analogue (e.g. from DVB-S/S2 to AM-VSB or DVB-T/T2 to AM-VSB) is made at the headend, the summation of the impairments that produce a relaxation of requirements at system outlet does not apply. Such a case will be the equivalence of unimpaired signals applied at the headend input. Therefore, the requirements at system outlet given in IEC 60728‑1 apply. This document also provides references for the basic methods of measurement of the operational characteristics of the downstream cable network in order to assess its performance. All requirements refer to the performance limits to be achieved in operation at any system outlet when terminated in a resistance equal to the nominal load impedance of the system, unless otherwise specified. Where system outlets are not
- Standard31 pagesEnglish languagesale 10% offe-Library read for×1 day
- 27-Jul-2023
- 33.040.20
- 33.160.01
- CLC/TC 209
IEC 60728-101:2016 is applicable to any cable network (including individual receiving systems) distributing only digital channels having in the forward path a coaxial cable output and primarily intended for television and sound signals operating between about 30 MHz and 3 000 MHz. This standard specifies the basic methods of measurement of the operational characteristics of a cable network having coaxial cable outputs in order to assess the performance of these systems and their performance limits.
- Standard113 pagesEnglish languagesale 10% offe-Library read for×1 day
- 18-May-2017
- 33.040.20
- 33.160.01
- CLC/TC 209
IEC 60728-101-1:2023 provides the requirements and describes the implementation guidelines of RF cabling for two-way home networks; it is applicable to any home network that distributes signals provided by CATV/MATV/SMATV cable networks (including individual receiving systems) having a coaxial cable output. It is also applicable to home networks where some part of the distribution network uses wireless links, for example in place of the receiver cord. This part of IEC 60728 is therefore applicable to RF cabling for two-way home networks with wired cords or wireless links inside a room and primarily intended for television and sound signals operating between about 5 MHz and 3 300 MHz. The frequency range is extended to 6 000 MHz for distribution techniques that replace wired cords with a wireless two-way communication inside a room (or a small number of adjacent rooms) that uses the 5 GHz to 6 GHz band. In a building divided into apartment blocks, the distribution of the signals inside the home starts from the home network interface (HNI) up to the system outlet or terminal input. The requirements at the system outlet are given in IEC 60728-101:2016, Clause 5 and the requirements at the HNI are given in IEC 60728-101:2016, Clause 7. In Clause 5 of this document, additional requirements are given. This document deals with various possibilities to distribute signals in a home network, using coaxial cables, balanced pair cables, fibre optic cables (glass or plastic) and also wireless links inside a room (or a small number of adjacent rooms) to replace wired cords. This document gives references to basic methods of measurement of the operational characteristics of the home cable network in order to assess its performance. All requirements refer to the performance limits, which are obtained between the input(s) at the home network interface (HNI) and the output at any system outlet when terminated in a resistance equal to the nominal load impedance of the system, unless otherwise specified. Where system outlets are not used, the above applies to the terminal input. The present document also provides limits for the accumulation of degradations if the home network is subdivided into a number of parts, using different transmission media (e.g. coaxial cabling, balanced cabling, optical cabling, wireless links). Clause 5 defines the performance limits measured at system outlet or terminal input for an unimpaired (ideal) test signal applied at the HNI. Under normal operating conditions for any digital channel and meeting these limits, the cumulative effect of the impairment of any single parameter at the HNI and that due to the home network produces signals not worse than the requirements given in IEC 60728-101-2. For digitally modulated signals, the quality requirement is a QEF (quasi error-free) reception. This document describes the physical layer connection for home networks. Description of protocols required for layer 2 and higher layers is out of the scope of this document. Logical connections between devices within the home network are therefore not always guaranteed. This International Standard is to be used in conjunction with IEC 60728-101:2016.
- Standard72 pagesEnglish languagesale 10% offe-Library read for×1 day
- 27-Jul-2023
- 33.040.20
- 33.160.01
- CLC/TC 209
IEC 60728-101-2:2023 provides the minimum performance requirements to be fulfilled in operation at the system outlet or terminal input and describes the summation criteria for the impairments present in the received signals and those produced by the CATV/MATV/SMATV cable network, including individual receiving systems. In a building divided into apartment blocks, the signals received by the antennas are distributed by the MATV/SMATV cable network up to the home network interface (HNI); the television signals are then distributed (inside the home) by home networks (HN) of various types up to the system outlet or terminal input. The cable network can support two-way operation, from the system outlet (or terminal input) towards the headend. The home network can use coaxial cables, balanced pair cables, fibre optic cables (glass or plastic) and also wireless links inside a room (or a small number of adjacent rooms) to replace wired cords. This part of IEC 60728 is limited to downstream TV broadcast signals received from antennas and is applicable to cable networks intended for television signals, sound signals and interactive services operating between about 5 MHz and 3 300 MHz. The frequency range is extended to 6 000 MHz for home distribution techniques that replace wired cords with a wireless two-way communication inside a room (or a small number of adjacent rooms) that uses the 5 GHz to 6 GHz frequency band. The main sections of a general CATV/MATV/SMATV system, indicating the parts of the IEC 60728-101 series documents where the relevant performance requirements are indicated. - The requirements for the signals received at the headend are given in IEC 60728-101:2016, Clause 6. - The requirements for the CATV/MATV/SMATV cable network, assuming an unimpaired input signal at the input of the headend, up to the system outlet are given in IEC 60728‑101:2016, Clause 5. - The requirements for the CATV/MATV/SMATV cable network up to the home network interface (HNI) are given in IEC 60728-101:2016, Clause 7, assuming an unimpaired input signal at the input of the headend. - The specific requirements from HNI to the system outlet or terminal input are given in IEC 60728-101-1:2023, Clause 5, assuming an unimpaired input signal at the HNI. - The requirements at the system outlet in operation are given in Clause 6 of this document. The expression "in operation" means that the received signals, with their impairments, are applied to the headend input of the CATV/MATV/SMATV cable network. The requirements at the system outlet "in operation" are derived, therefore, by summing the impairments of the various cascaded parts of the system and of the input signal. When a change of signal format from digital to digital (e.g. from QPSK to QAM) (e.g. as in ETSI EN 300 473) or from digital to analogue (e.g. from DVB-S/S2 to AM-VSB or DVB-T/T2 to AM-VSB) is made at the headend, the summation of the impairments that produce a relaxation of requirements at system outlet does not apply. Such a case will be the equivalence of unimpaired signals applied at the headend input. Therefore, the requirements at system outlet given in IEC 60728‑1 apply. This document also provides references for the basic methods of measurement of the operational characteristics of the downstream cable network in order to assess its performance. All requirements refer to the performance limits to be achieved in operation at any system outlet when terminated in a resistance equal to the nominal load impedance of the system, unless otherwise specified. Where system outlets are not
- Standard31 pagesEnglish languagesale 10% offe-Library read for×1 day
- 27-Jul-2023
- 33.040.20
- 33.160.01
- CLC/TC 209
IEC 60728-101:2016 is applicable to any cable network (including individual receiving systems) distributing only digital channels having in the forward path a coaxial cable output and primarily intended for television and sound signals operating between about 30 MHz and 3 000 MHz. This standard specifies the basic methods of measurement of the operational characteristics of a cable network having coaxial cable outputs in order to assess the performance of these systems and their performance limits.
- Standard113 pagesEnglish languagesale 10% offe-Library read for×1 day
- 18-May-2017
- 33.040.20
- 33.160.01
- CLC/TC 209
IEC 60947-5-7:2024 states the requirements for proximity devices that correspond to the scope of IEC 60947-5-2:2019 with analog output (PDAO) and/or a digital output to transmit a corresponding digital value representing the detected sensing input. These devices can provide additional parameters. This second edition cancels and replaces the first edition published in 2003. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) New structure; b) Update and expansion of definitions on analog output properties; c) Expanded performance requirements on analog output; d) Update and new normative references; e) Update of EMC requirements; f) Harmonization with IEC 62828 series; g) Harmonization with IEC 62683 and IEC 61987 definitions; h) Harmonization with IEC 61131-2 requirements; i) Update of the Annex A (former Annex G), Example of the determination of the conformity; j) New Annex B, Overview tests and influence quantities; k) New Annex C, Additional requirements for proximity switches with analog output incorporating a built-in communication interface complying with IEC 61131-9; l) New Annex D, Main characteristics for proximity devices with analog output.
- Draft45 pagesEnglish languagesale 10% offe-Library read for×1 day
IEC 60947-4-1:2023 is applicable to the following equipment: - electromechanical contactors and starters including motor protective switching devices (MPSD and IMPSD); - actuators of contactor relays; - contacts dedicated exclusively to the coil circuit of the contactor or the contactor relay; - dedicated accessories (e.g. dedicated wiring, dedicated latch accessory); intended to be connected to distribution circuits, motors circuits and other load circuits, the rated voltage of which does not exceed 1 000 V AC or 1 500 V DC. This fifth edition cancels and replaces the fourth edition published in 2018. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) objective in the scope; b) instantaneous only motor protective switching device IMPSD (3.5.33); c) kinds of equipment (5.2.1); d) methods of overload protection of motors (5.2.6); e) adoption of the AC-7d from IEC 61095:2023 (in 5.4.2); f) separately mounted overload relay of a starter (in 5.7.3 b)); g) starter and contactor suitable for use downstream to basic drive module (6.1.2 w)); h) reference to IEC TS 63058 for environmental aspects (in 6.4); i) wiring subject to movement (in 8.1.3); j) use of voltage transient limiting device (8.1.18); k) accessible parts subject to temperature limits (in 8.2.2.3); l) reference to Annex X of IEC 60947-1:2020 for the co-ordination of MPSD with SCPD (8.2.5.4); m) reference to IEC TR 63216 with different EMC environments (8.3.1); n) reference to IEC TR 63201 for the embedded software design (8.4); o) reference to IEC TS 63208 for cybersecurity aspects (8.5); p) update and completion of the measurement method of the power consumption of the electromagnet (9.3.3.2.1.2); q) update of Annex C including rational about AC-3e; r) determination of the critical load current for photovoltaic applications (M.8.7).
- Draft179 pagesEnglish languagesale 10% offe-Library read for×1 day
IEC 62626-1:2023 is available as IEC 62626-1:2023 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 62626-1:2023 applies to enclosed switches-disconnectors with rated voltages up to 1 000 V AC for repair and maintenance work or cleaning work in load circuits. Devices within the scope of this document are switch-disconnectors in accordance with IEC 60947-3 with specific additional requirements. Enclosed switch-disconnectors in this document are suitable for isolation in accordance with the IEC 60947 series and are not equipped with means for remote control or automatic switching to avoid unexpected or accidental start. These devices are not used for operational switching, for example quick start and stop, jogging. This second edition cancels and replaces the first edition published in 2014. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) update of this document based on IEC 60947-1:2020.
- Draft11 pagesEnglish languagesale 10% offe-Library read for×1 day
- 04-Sep-2025
- 29.120.40
- 29.130.20
- 2014/35/EU
- M/511
- CLC/TC 121A
IEC 61095:2023 is available as IEC 61095:2023 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 61095:2023 applies to electromechanical air break contactors for household and similar purposes provided with main contacts intended to be connected to circuits the rated voltage of which does not exceed 440 V AC (between phases) with rated operational currents less than or equal to 63 A for utilization category AC-7a, and 32 A for utilization categories AC‑7b, AC‑7c and AC-7d (expressed in rated power), and rated conditional short-circuit current less than or equal to 6 kA. This third edition cancels and replaces the second edition published in 2009. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) addition of requirements for screwless terminals; b) addition of requirements for the switching of LED lamps. Contactors for domestic and similar applications can be used for controlling lighting loads which is increasingly using LED lamp technology. A specific category for contactors is created: AC-7d. Requirements and tests are added to cover this market development, mainly for making and breaking and conventional operational performance; c) addition of requirements for contactors with electronically controlled electromagnet. Household contactors with electronically controlled electromagnet are available for years on the market. To fully cover such device, requirements and tests are added, dealing mainly with operating limits, behaviour in abnormal conditions, breakdown of components, EMC tests, etc. d) embedded software. More and more contactors are incorporating electronic circuits with embedded software. A reference is provided to guide the design of the software.
- Draft141 pagesEnglish languagesale 10% offe-Library read for×1 day
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.